You are on page 1of 129

Service Training

MALAGA

345C/365C/385C
HYDRAULIC
EXCAVATORS

4 : 03 10

OK

MONITOR
Francis
Sep 05
Monitoring System Operation Manual

- Contents -
1. Outline of the Monitor..................................................................................... 1
1.1. Parts Name .................................................................1
1.2. Startup Process ............................................................5
1.2.1. Pre-start Monitoring Function ..........................................5
1.3. Warning Indications ........................................................6
2. Outline of Service Functions .......................................................................... 9
2.1. Password Entry ............................................................11
3. Setting.......................................................................................................... 12
3.1. Display Setup .............................................................12
3.1.1. Clock Adjust ..........................................................12
3.1.2. Select Language .......................................................13
3.1.3. Select Indication Item.................................................14
3.1.4. Adjust Contrast .......................................................15
3.1.5. Adjust Brightness .....................................................16
3.2. Work Tool Select ..........................................................17
3.3. Controls Setup(365C/385C)..................................................18
4. Maintenance Information.............................................................................. 19
5. Performance ................................................................................................ 21
6. Service ......................................................................................................... 23
6.1. Maintenance ...............................................................24
6.1.1. Reverse Fan ...........................................................24
6.1.2. Filter/Fluid Information ...............................................26
6.1.3. Recommend Interval.....................................................27
6.1.4. Work Hour Info.........................................................28
6.2. Password Change............................................................29
6.3. Diagnostic ................................................................30
6.3.1. Active Error ..........................................................30
6.3.2. Logged Error...........................................................31
6.3.3. Logged Event...........................................................33
6.4. ECM Info ..................................................................35
6.4.1. Machine ECM ...........................................................35
6.4.2. Engine ECM.............................................................36
6.4.3. Monitor................................................................37
6.4.4. Attachment ECM (345C)..................................................38
6.5. Status ....................................................................39
6.5.1. Digital Input Status ..................................................39
6.5.2. Analog Input Status....................................................42
6.5.3. Output Status..........................................................44
6.5.4. Misc Status............................................................47
6.6. Calibrations ..............................................................49
Monitoring System Operation Manual

6.6.1. Control Valves ........................................................49


6.6.2. Relief Valves (345C/300D Phase 1)......................................61
6.6.3. Power Shift Pressure Valve.............................................63
6.6.4. Flow Limit Valve (345C/300D Phase 1)..................................64
6.6.5. Check Valve (365C/385C)................................................67
6.6.6. Lever/Pedal/Attachment Inputs..........................................69
6.6.7. Engine Speed...........................................................80
6.6.8. Fan Speed..............................................................81
6.7. Device Test (345C/300D Phase 1) ...........................................82
6.7.1. Desired Engine Speed ..................................................82
6.7.2. Power Shift Pressure...................................................83
6.7.3. Flow Limit Valve Pressure..............................................84
6.7.4. Attachment Valve #1 Extend.............................................85
6.7.5. Attachment Valve #1 Retract............................................86
6.7.6. Attachment Valve #3 Extend.............................................87
6.7.7. Attachment Valve #3 Retract............................................88
6.7.8. A1 Relief Valve........................................................89
6.7.9. A2 Relief Valve........................................................90
6.7.10. 2 Pump Flow Limit.....................................................91
6.7.11. 1 Pump Flow Limit.....................................................92
6.8. Override ..................................................................93
6.9. Configurations ............................................................95
6.9.1. Attachment Parts Installation .........................................95
6.9.2. Tool Installation......................................................96
6.9.3. Controls Installation..................................................97
6.9.4. Front Linkage Configuration (365C / 385C)..............................98
6.9.5. Product ID.............................................................99
6.9.6. Parameter Setting.....................................................100
6.10. Tool Program ............................................................115
Appendix A. MID List ..................................................................................... 119
Appendix B. CID List...................................................................................... 120
Appendix C. FMI List ..................................................................................... 123
Appendix D. EID List...................................................................................... 124
Appendix E. DSI List...................................................................................... 125
Appendix F. RROR ID List............................................................................. 126
Monitoring System Operation Manual

1. Outline of the Monitor


1.1. Parts Name

① … Alert indicator
This lamp blinks when the serious
warning occurs. About the warning
indication, See "1.3. Warning
Indicator".

② … Display
See the next page about each
indication item.

③ … Keypad

The Keys Functions


Name Functions
Home key Return to the default screen (normal gauge screen)
Menu key Access the main menu
OK key Select menu option/Set value
Back key Reject setting value/Return to the previous screen
Up key Move the cursor upward/Increase values
Down key Move the cursor downward/Decrease values
Right key Move the cursor to the right/Increase values
Left key Move the cursor to the left/Decrease values

1
Monitoring System Operation Manual

Default Screen (Normal Gauge Screen)

Clock

Engine Speed Dial Indicator


8:45 10
Fuel Level

Hydraulic Oil Temperature

Coolant Temperature

ENG OIL PRESS


Warning Indication Area
LOW
BUCKET/NO TOOL Setting Indication Area

Waning Indication Area

Indication Name Description


When the warning occur, a short message and a
ENG OIL PRES symbol are displayed in this area. About the
Warning Indication
LOW detail of each warning, see "1.3. Warning
Indicator".
Normally, nothing is displayed in this area.
Nothing

If the setting of the service hour meter indication


is enable, the total operation hour is displayed in
Service Hour Meter
00000 [h] this area. See "3.1.3. Select Indication Item"
about this setting.

Note: The total operation hour is counted by Machine ECM. So if you want to know accurate
operation time, see the mechanical service hour meter.

2
Monitoring System Operation Manual

Settin Indication Area

Indication Name Description


When the setting of gain/response mode is
CAT Logo / Normal normal or the setting of tool name indication is
disable, CAT logo is displayed in this area.

When the setting of gain/response mode is soft,


the soft mode symbol is displayed in this area.
SOFT Soft Mode
(365C/385C only)

When the setting of gain/response mode is


quick, the quick mode symbol is displayed in this
QUICK Quick Mode
area.
(365C/385C only)
When the setting of tool name indication is
enable, tool name is displayed in this area. About
BUCKET/NO TOOL Tool Name Indication
the setting of tool name indication, see “3.1.3.
Select Indication Item”. (345C only)

Note: Gain/Response Mode is changed by pushing the gain/response switch of the standard
switch panel module. (See the following picture.)

3
Monitoring System Operation Manual

Main Menu Screen (Service Mode Screen)


Title Bar
In this area, the screen title is displayed. Normally, the
8:45 10 background color is blue, but when the warning occurs, the
background color is changed to red or yellow or green. This
MAIN MENU color is same as background color of warning indicator
which is the most important at the time.
SETTING
Main Display
Indication item in this area are various for each screen.

PRESS TO SET
CLOCK, LANGUAGE,
TOOL AND CONTROLS Operation Guidance
In this area, the short message which explain the function of
key is displayed.
/ :MOVE CURSOR

4
Monitoring System Operation Manual

1.2. Startup Process

Turn the engine start switch to the ON position. After approximately one second, CAT logo
appears in the display and the alert indicator turns on. The coolant temperature, the hydraulic
oil temperature, the fuel level, and the position of the engine speed dial are now indicated.
And the pattern for the joystick controls is indicated in the bottom of display for 3 sec
(Electronic Joystick System Only).

Display Joystick controls

SAE/JIS SYSTEM SAE/JIS system (4way, 2way)

MHI SYSTEM MHI system (4way)

KOB SYSTEM KOB system (4way)

FORMER SCM SYSTEM Former SCM system (4way)

BHL SYSTEM BHL system (2way)

1.2.1. Pre-start Monitoring Function

The monitoring system checks the level of the engine coolant, the engine oil, and the
hydraulic oil before the engine starts. If the fluid level check detects a low fluid level, the
appropriate message will be displayed and a pictograph will be shown to indicate the fluid
level that is low.

Note: If more than one fluid level is low, the right key and the left key symbols are indicated
in the bottom right area of warning message indication. Press the right key or the left key, and
check other indicated warning message. The low fluid level indicators will disappear after five
seconds when the engine is started.

Note: The machine cannot perform an accurate fluid level check when the machine is on a
slope. Perform the fluid level check on level ground.

If the engine is started during the fluid level check, the monitor will cancel these checks.

The service hours for the filters are checked and the service hours for the fluids are checked
next. If a filter or a fluid is over the recommended change interval, “CHECK FLTR/FLUID
INFO” appears on the display. Refer to “Main Menu” for further information.

5
Monitoring System Operation Manual

1.3. Warning Indications

When some events or warning have occurred, the following message will be displayed in the
default screen.

Warning Indication List (1/3)


MESSAGE CAUSE ACTION
UNAUTHORIZED
Unauthorized MSS key is inserted. Insert authorized MSS key.
KEY
SERVICE Error has been discovered in self diagnostic Call out Service person.
REQUIRED process.
COOLANT LEVEL Fill in coolant water to the normal
Coolant level is lower than the normal level.
LOW level.
ENG OIL LEVEL Engine oil level is lower than the normal
Fill in engine oil to the normal level.
LOW level.
HYD OIL LEVEL The hydraulic oil level is lower than the Fill in hydraulic oil to the normal
LOW normal level. level.
INTAKE AIR Do not operate engine until the
Intake air heater is operating.
HEATER ON warning goes dark.
INLET AIR TEMP Inlet air temperature is higher than the Stop engine and check the cause of
HIGH normal temperature. warning.
INLET AIR TEMP Active inlet air temp power derating control Stop engine and check the cause of
POWER DERATE because the temp is too high. warning.
LIFT OVERLOAD
Lifting load is over load rating. Unload the lifting load.
WARNING
ENG OIL PRESS Engine oil pressure is lower than the normal Stop engine and check the cause of
LOW pressure. warning.
ENG OIL PRESS Active engine oil pressure power derating Stop engine and check the cause of
POWER DERATE control because the pressure is too low. warning.
COOLANT TEMP Coolant temperature is higher than the Stop operating and wait until falling
HIGH normal temperature. in temperature.
COOLANT TEMP Active coolant temp power derating control Stop operating and wait until falling
POWER DERATE because the coolant temp is too high. in temperature.
HYD OIL TEMP Hydraulic oil temperature is higher than Stop operating and wait until falling
HIGH normal temperature. in temperature.
HYD OIL TEMP Active hyd oil temp power derating control Stop operating and wait until falling
POWER DERATE because hyd oil temp is too high. in temperature.
HYD OIL TEMP Hydraulic oil temperature is higher than the Stop operating and wait until falling
HIGH (TOOL) temperature regulated by tool. in temperature.
LIMITED MOBILITY
Limited mobility mode is on.
MODE

6
Monitoring System Operation Manual

Warning Indication List (2/3)


MESSAGE CAUSE ACTION
BATTERY VOLTAGE Battery voltage irregular. (Low/High
Check the charging circuit.
IRREGULAR voltage, Defective alternator)
ECM
ECM error. (Defective connection etc.) Contact to the dealer.
ERROR
ENGINE ECM Engine controller (ADEM) error. (Defective
Contact to the dealer.
ERROR connection etc.)
MONITOR
Monitor error. (Defective connection etc.) Contact to the dealer.
ERROR
TOOL CONTROL Stop using tool and check the cause
Tool control malfunction.
MALFUNCTION of warning.
AUTO LUBE Stop using the auto lubrication and
Auto lubrication error.
ERROR check the cause of warning.
REVERSE FAN Reverse fan error. (Oil temp high /Defective
Contact to the dealer.
ERROR SOL/Hyd lock system off etc.)
QUICK COUPLER
Quick coupler is unlocked. Lock the quick coupler.
UNLOCK
FUEL PRESS
Fuel pressure is too high. Contact to the dealer.
HIGH
HYD RETURN FLTR
Hydraulic return filter is plugged. Maintain the hydraulic return filter.
PLUGGED
INTAKE AIR FLTR
Intake air filter is plugged. Maintain the intake air filter.
PLUGGED
FUEL FLTR
Fuel filter is plugged. Maintain the fuel filter.
PLUGGED
FUEL FLTR Active fuel filter power derating control
Maintain the fuel filter.
POWER DERATE because the fuel filter is plugged.
WATER SEPARATOR
Water separator is full. Maintain the water separator.
FULL
ATT FLTR
Attachment filter is plugged. Maintain the attachment filter.
PLUGGED
ENG OVERSPEED
Engine over speed error. Contact to the dealer.
WARNING
ENGINE SHUTDOWN
Active engine shutdown function. Contact to the dealer.
ACTIVATING
LEVER IS NOT Need to keep the lever to the neutral Locate the lever to the neutral
NEUTRAL position. position.
COUNTERWEIGHT
Counterweight removal warning.
REMOVAL
CHECK FILTER / Use time of filter or something is over Replace new filter and reset new
FLUID INFO expiration of suggested replacement. period for replacement

7
Monitoring System Operation Manual

Warning Indication List (3/3)


MESSAGE CAUSE ACTION
NOT CONFIGURED Configuration has been never done on
Execute configuration function.
some items.
NOT CALIBRATED Calibration has been never done on some
Execute calibration function.
items.
CYCLE THE LOCK
Need to cycle the lock lever. Cycle the lock lever.
LEVER
FUEL LEVEL
Fuel level is lower than normal level. Refill fuel.
LOW
LUBE LEVEL Lubrication level is lower than the normal
Refill lubrication.
LOW level.
LUBE
Lubrication starting.
STARTING
REVERSE FAN
Reverse fan starting. Do not operate till the end.
STARTING

8
Monitoring System Operation Manual

2. Outline of Service Functions

Menu Key:

MAIN MENU
SETTING SETTING
MAINTENANCE INFO Indicate DISPLAY SETUP Clock adjust/Language
PERFORMANCE filter/fluid WORK TOOL SELECT select/Indicated item
SERVICE information select/Contrast adjust/
Brightness adjust

Indicate sensors information

USER PASSWORD :0001(DEFAULT)


0001(DEFAULT) … Limited items are available
SERVICE PASSWORD :FFF2(FIXED)
FFF2(FIXED) … All items are available

SERVICE
MAINTENACE MAINTENANCE
PASSWORD CHANGE Change user REVERSE FAN Start/Stop the
DIAGNOSTIC password FLTR/FLUID INFO reverse fan
ECM INFO
RECOMMEND INTERVAL
STATUS
WORK HOUR INFO
CALIBRATIONS
OVERRIDE
DEVICE TEST
CONFIGURATIONS
TOOL PROGRAM

DIAGNOSTIC Indicate diagnostic information


ECM INFO Indicate each ECM information
STATUS Indicate input information of
switches/sensors and output information
CALIBRATIONS Calibrate devices
OVERRIDE Test output
DEVICE TESET Test output
CONFIGURATIONS Configure parameters for the machine
TOOL PROGRAM Configure parameters for work tool

9
Monitoring System Operation Manual

[Entry]

Press the menu key in order to enter the service mode (Main Menu). And go to the desired
menu by using the up/down/right/left/OK key. The menu key is available in every menu. If the
menu key is pressed while doing some functions, the monitor stops doing that function and
displays the main menu.

[Exit]
Press the home key in order to return to the default screen.
When the home key is pressed, the monitor stops doing service mode functions.
The home key is available in every menu.

Note: If the home key/the menu key is pressed while doing some functions, it takes 1-2
seconds to return to the default screen/the main menu for exit process

10
Monitoring System Operation Manual

2.1. Password Entry PASSWORD ↓


Press the right key or the ENTER PASSWORD
PASSWORD
left key in order to select the ENTER PASSWORD
_ _ _ _
desired character.
F F F _
BCDEF0123
Press the OK key when you
enter the highlighted PRESS TO ENTER
BCDEF0123
character. HIGHLIGHTED LETTER
PRESS TO ENTER
HIGHLIGHTED LETTER
The monitoring system
checks the password when :DELETE
you finish entering 4 / :MOVE CURSOR
:DELETE
characters. If the password ↓ / :MOVE CURSOR
is correct, you will have ↓
access to the menu.

PASSWORD ↓
If the password is incorrect,
ENTER PASSWORD
“INVALID PASSWORD” will PASSWORD
be displayed. Press the OK F _ _ _
ENTER PASSWORD
key in order to retry the
F F F _
password or press the BCDEF0123
cancel key in order to exit. EF0123456
PRESS TO ENTER
Note: Press the back key in HIGHLIGHTED LETTER
PRESS TO ENTER
order to delete the entered HIGHLIGHTED LETTER
character. The initial user
:DELETE
password is “0001”, and the
/ :MOVE CURSOR
service password is “FFF2”. :DELETE
↓ / :MOVE CURSOR
[Service password entry] ↓
PASSWORD
ENTER PASSWORD

PASSWORD ↓
ENTER PASSWORD
_ _ _ _ [Complete]
CDEF01234 F F _ _

PRESS TO ENTER BCDEF0123


HIGHLIGHTED LETTER
PRESS TO ENTER
HIGHLIGHTED LETTER
:DELETE
/ :MOVE CURSOR
:DELETE
↓ / :MOVE CURSOR


11
Monitoring System Operation Manual

3. Setting
3.1. Display Setup
3.1.1. Clock Adjust
( MAIN MENU → SETTING → DISPLAY SETUP → CLOCK ADJUST )

↓ DISPLAY SETUP [Adjust clock]


MAIN MENU CLOCK ADJUST ▲ Press the left key or the
LANGUAGE SELECT right key in order to select
SETTING INDICATED ITEM the hour or the minute.
CONTRAST Press the up key in order to
BRIGHTNESS
increase the number. Press
BRIGHTNESS( ) ▼
PRESS TO ADJUST
the down key in order to
CLOCK decrease the number.
PRESS TO SET
CLOCK, LANGUAGE,
TOOL AND CONTROLS
When the clock is set to the
desired time, press the OK
/ :MOVE CURSOR key.
/ :MOVE CURSOR ↓
↓ If you don't want to save the
↓ changed value, press the
↓ CLOCK ADJUST home key/the back key
SETTING
before the OK key is
DISPLAY SETUP ▲
pressed.
WORK TOOL SELECT
CONTROL SETUP HH:MM Function
Set the changed
number
▼ Cancel
PRESS TO SET
:SET Increase the number
CLOCK, LANGUAGE,
AND BRIGHTNESS :CANCEL Decrease the number
/ :+/- Move cursor
/ :MOVE CURSOR
Move cursor
/ :MOVE CURSOR ↓
↓ [Adjust clock]



Default Screen

12
Monitoring System Operation Manual

3.1.2. Select Language


( MAIN MENU → SETTING → DISPLAY SETUP → LANGUAGE SELECT )

Go to the
DISPLAY SETUP LANGUAGE SELECT [Select language]
○ENGLISH ▲ Press the up key or the
Refer to ○FRANCAIS down key in order to scroll
“3.1.1. Clock Adjust” ○DEUTSCH through the available
○ITALIANO
↓ languages. And move
○ESPAÑOL
DISPLAY SETUP ○日本語 ▼
cursor to the desired
CLOCK ADJUST ▲ PRESS TO SELECT language. Press the set key
LANGUAGE SELECT HIGHLIGHTED ITEM in order to select the desired
INDICATED ITEM language.
CONTRAST
BRIGHTNESS :SELECTED
BRIGHTNESS( ) ▼ / :MOVE CURSOR
PRESS TO ADJUST ↓
CLOCK
[Select language]

/ :MOVE CURSOR ↓
↓ Default Screen
Function
Select the highlighted
↓ item
DISPLAY SETUP
Move cursor
CLOCK ADJUST ▲
LANGUAGE SELECT Move cursor
INDICATED ITEM
CONTRAST
BRIGHTNESS
BRIGHTNESS( ) ▼
PRESS TO SELECT
DISPLAY LANGUAGE

/ :MOVE CURSOR

13
Monitoring System Operation Manual

3.1.3. Select Indication Item USER PASSWORD REQUIRED


( MAIN MENU → SETTING → DISPLAY SETUP → INDICATED ITEM )

Go to the [Select indicated item]


Enter Password
DISPLAY SETUP Use the up key or the down
Enter User Password or key in order to highlight
Refer to Service Password either “TOOL NAME” or
“3.1.1.Clock Adjust” (FFF2). Refer to “SERVICE HR METER”.
“2.1.Password Entry” Press the OK key in order to

DISPLAY SETUP ↓ enable the item. Also, press
CLOCK ADJUST ▲ INDICATED ITEM the OK key in order to
LANGUAGE SELECT □TOOL NAME ▲ disable the item. By
INDICATED ITEM □SERVICE HR METER choosing to enable the item,
CONTRAST □ECONO MODE FIX that item will be displayed
BRIGHTNESS on the default screen. By
BRIGHTNESS( ) ▼ choosing to disable the item,
PRESS TO ADJUST ▼
that item will be removed
CLOCK PRESS TO CHANGE from the default display.
ENABLE/DISENABLE
OF HIGHLIGHTED
Note: On 365C/385C, the
/ :MOVE CURSOR :ENABLE item of "TOOL NAME" is not
↓ / :MOVE CURSOR displayed because the
↓ information of "GAIN
[Select indicated item] RESPONSE" is displayed

↓ instead of the tool name in
DISPLAY SETUP
default display.
CLOCK ADJUST ▲
LANGUAGE SELECT
INDICATED ITEM

CONTRAST Default Screen
BRIGHTNESS
BRIGHTNESS( ) ▼
PRESS TO SET Function
INDICATED ITEM Select the highlighted
item
Move cursor
Move cursor
/ :MOVE CURSOR

14
Monitoring System Operation Manual

3.1.4. Adjust Contrast


( MAIN MENU → SETTING → DISPLAY SETUP → CONTRAST )

Go to the
DISPLAY SETUP CONTRAST [Adjust contrast]
The contrast can be set
Refer to between “0” and “10”. Press
“3.1.1.Clock Adjust” the right key in order to
↓ increase the contrast. Press
DISPLAY SETUP 5
the left key in order to
CLOCK ADJUST ▲ decrease the contrast.
LANGUAGE SELECT
INDICATED ITEM
CONTRAST
BRIGHTNESS
BRIGHTNESS( ) ▼ / :-/+
PRESS TO ADJUST ↓ Function
CLOCK Increase the number
[Contrast adjust]
Decrease the number

/ :MOVE CURSOR ↓
↓ Default Screen

DISPLAY SETUP
CLOCK ADJUST ▲
LANGUAGE SELECT
INDICATED ITEM
CONTRAST
BRIGHTNESS
BRIGHTNESS( ) ▼
PRESS TO SET
CONTRAST

/ :MOVE CURSOR

15
Monitoring System Operation Manual

3.1.5. Adjust Brightness


( MAIN MENU → SETTING → DISPLAY SETUP → BRIGHTNESS )

Go to the
DISPLAY SETUP BRIGHTNESS [Adjust brightness]
The brightness can be set
Refer to between “0” and “10”. Press
“3.1.1.Clock Adjust” the right key in order to
↓ increase the brightness.
DISPLAY SETUP 5
Press the left key in order to
CLOCK ADJUST ▲ decrease the brightness.
LANGUAGE SELECT
INDICATED ITEM
CONTRAST Function
BRIGHTNESS
BRIGHTNESS( )
Increase the number
▼ / :-/+
PRESS TO ADJUST Decrease the number

CLOCK
[Adjust brightness]

/ :MOVE CURSOR


Default Screen

DISPLAY SETUP
CLOCK ADJUST ▲
LANGUAGE SELECT
INDICATED ITEM
CONTRAST
BRIGHTNESS
BRIGHTNESS( ) ▼
PRESS TO SET
BRIGHTNESS

/ :MOVE CURSOR

16
Monitoring System Operation Manual

3.2. Work Tool Select


( MAIN MENU → SETTING → WORK TOOL SELECT )

Go to the NOTE: The work tool can


SETTING WORK TOOL SELECT be selected by pushing tool
○TOOL #01 ▲ select switch in the standard
Refer to ○TOOL #02 switch panel.
“3.1.1.Clock Adjust” ○TOOL #03
○TOOL #04
↓ ○TOOL #05
SETTING ○TOOL #06 ▼
DISPLAY SETUP ▲ PRESS TO SELECT
WORK TOOL SELECT HIGHLIGHTED ITEM

:SELECTED Push the tool select switch


▼ / :MOVE CURSOR in order to display the work
PRESS TO SET ↓ tool select screen.
CLOCK, LANGUAGE,
AND BRIGHTNESS
[Select work tool]
↓ Then push this switch in
order to highlight the
/ :MOVE CURSOR desired item.

↓ Default Screen And push this switch more
than 2 seconds in order to
↓ set the highlighted item.
SETTING
[Select work tool]
DISPLAY SETUP ▲
WORK TOOL SELECT
Press the up key or the
CONTROL SETUP down key in order to
highlight the desired work
tool.
▼ Press the OK key in order to
PRESS TO SELECT select the new work tool.
WOOK TOOL
Note: When you change the
work tool, make the
/ :MOVE CURSOR
hydraulic lock switch ON.

Function
Select the highlighted

item
Move cursor
Move cursor

17
Monitoring System Operation Manual

3.3. Controls Setup(365C/385C) USER PASSWORD REQUIRED


( MAIN MENU → SETTING → CONTROL SETUP )

Go to the [Select controls pattern]


Enter Password
SETTING Press the up key or the
Enter User Password or down key in order to select
Refer to Service Password a pattern. Press the OK key
“3.1.1.Clock Adjust” (FFF2). Refer to in order to select the new
“2.1.Password Entry” pattern.

SETTING ↓
DISPLAY SETUP ▲ CONTROL SETUP Note: When you change the
WORK TOOL SELECT ○SAE/JIS ▲ controls pattern make the
CONTROL SETUP ○MHI hydraulic lock switch ON
○KOB and make levers and pedals
○FORMAER SCM neutral.
▼ ○BHL
PRESS TO SET ▼ Function
CLOCK, LANGUAGE, PRESS TO SELECT
AND BRIGHTNESS
Select the highlighted
HIGHLIGHTED ITEM
item
Move cursor
/ :MOVE CURSOR :SELECTED Move cursor
↓ / :MOVE CURSOR

↓ [Select controls pattern]
SETTING
DISPLAY SETUP ▲

WORK TOOL SELECT
CONTROL SETUP ↓
Default Screen

PRESS TO SET
CONTROLS

/ :MOVE CURSOR

18
Monitoring System Operation Manual

4. Maintenance Information
( MAIN MENU → MAINTENANCE INFO )

MAINTENANCE INFO [Maintenance Information]


↓ ENGINE OIL FILTER ▲ A list of system components
XXXX/YYYY[HR] will be displayed. Press the
MAIN MENU
HYD OIL RET FILTER up key or the down key in
XXXX/YYYY[HR]
SETTING order to scroll through the
PILOT OIL FILTER
XXXX/YYYY[HR] ▼
list.

XXXX:
The accumulated hours
PRESS TO SET
CLOCK, LANGUAGE,
TOOL AND CONTROLS
YYYY:
/ :SCROLL The recommended
↓ intervals
/ :MOVE CURSOR [Maintenance
↓ Information]
↓ Function
↓ Scroll
MAIN MENU ↓ Scroll
Default Screen
MAINTENANCE INFO Note: The indication item
varies by the model. And
the item which is checked at
the next table may not be
PRESS TO CHECK
indicated by the machine
FLUID/FLTR/COMPO configuration.
MAINTENANCE HOUR

/ :MOVE CURSOR

19
Monitoring System Operation Manual

Maintenance Information List (1/1)

365C, 385C
345C
Display Detail
COOLANT x x Accumulated hour of coolant
HYD OIL x x Accumulated hour of hydraulic oil
ENGINE OIL x x Accumulated hour of engine oil
SWING DRIVE OIL x x Accumulated hour of swing drive oil
FINAL DRIVE OIL x x Accumulated hour of final drive oil
WATER SEPARATOR x x Accumulated hour of water separator
ENGINE OIL FILTER x x Accumulated hour of engine oil filter
FUEL FILTER x x Accumulated hour of fuel filter
PILOT OIL FILTER x x Accumulated hour of pilot oil filter
DRAIN OIL FILTER x x Accumulated hour of drain oil filter
HYD OIL RET FILTER x x Accumulated hour of hydraulic oil return filter
ATT FILTER x x Accumulated hour of attachment hydraulic oil filter
ENGINE x x Accumulated hour of engine
PUMP x x Accumulated hour of pump
TRAVEL MOTOR x x Accumulated hour of travel motor
SWING MOTOR x - Accumulated hour of swing motor
TOOL #01 x x Accumulated hour of tool#1
TOOL #02 x x Accumulated hour of tool#2
TOOL #03 x x Accumulated hour of tool#3
TOOL #04 x x Accumulated hour of tool#4
TOOL #05 - x Accumulated hour of tool#5

20
Monitoring System Operation Manual

5. Performance
( MAIN MENU → PERFORMANCE )

PERFORMANCE [Performance]

BATTERY VOLTAGE ▲ A list of system components
------[V] and measurements will be
MAIN MENU ENGINE SPEED displayed. Press the up key
------[RPM]
SETTING or the down key in order to
COOLANT TEMP
------[℃] ▼
scroll through the list.

PRESS TO SET
CLOCK, LANGUAGE,
TOOL AND CONTROLS / :SCROLL Function
↓ Scroll
[Performance] Scroll
/ :MOVE CURSOR
↓ ↓
Note: The indication item
varies by the model. And
↓ ↓
the item which is checked at
MAIN MENU Default Screen the next table may not be
indicated by the machine
PERFORMANCE
configuration.

PRESS TO SEE
PERFORMANCE

/ :MOVE CURSOR

21
Monitoring System Operation Manual

Machine Information List (1/1)

365C, 385C
345C
Display Detail
BATTERY VOLTAGE x x Battery Voltage
ENGINE SPEED x x Engine Speed
COOLANT TEMP x x Coolant Temperature
HYD OIL TEMP x x Hydraulic Oil Temperature
PUMP #1 PRES - x Pump #1 Pressure
PUMP #2 PRES - x Pump #2 Pressure
MAIN PUMP PRES x - Main Pump Pressure
SWING PUMP PRES x - Swing Pump Pressure
POWER SHIFT PRES x x Power Shift Pressure
FLOW LIMIT PRES - x Flow Limit Pressure
FLOW LIMIT - x Flow Limitation

22
Monitoring System Operation Manual

6. Service USER PASSWORD


PASSWORD REQUIRED
( MAIN MENU → SERVICE )

SERVICE PASSWORD CHANGE


↓ MAINTENANCE ▲ You can change user
PASSWORD CHANGE password.
MAIN MENU
DIAGNOSTIC
ECM INFO
SETTING DIAGNOSTIC
STATUS
CALIBRATIONS ▼
You can check diagnostic
PRESS TO CHANGE Information (real time error,
MAINTE INFO logged error, logged events).
PRESS TO SET
ECM INFO
CLOCK, LANGUAGE,
TOOL AND CONTROLS
You can see each ECM
/ :MOVE CURSOR information.

/ :MOVE CURSOR [Service Mode] STATUS
↓ ↓ You can see inputs of
sensors and switches,
↓ ↓ outputs of machine ECM.
MAIN MENU Default Screen
CALIBRATIONS
SERVICE You can calibrate each
device.

[Service Mode] DEVICE TEST


A monitor provides you the You can test each device.
PRESS TO ENTER following functions in
SERVICE MODE Service Mode. OVERRIDE
You can test each device.
*…When you enter user
password, a monitor provides you CONFIGURATIONS
/ :MOVE CURSOR only part of MAINTENANCE and
↓ PASSWORD CHANGE. You can configure machine
ECM.
↓ TOOL PROGRAM
MAINTENANCE
Enter Password You can reset accumulated You can program each tool
hour of filters and fluids and setting.
Enter User Password or work hour of components,
Service Password
(FFF2). Refer to
and change recommended
“2.1.Password Entry” intervals. You can also
operate Reversing Fan
↓ System.

23
Monitoring System Operation Manual

6.1. Maintenance USER PASSWORD REQUIRED


6.1.1. Reverse Fan
( MAIN MENU → SERVICE → MAINTENANCE → REVERSE FAN )

Go to the [Reverse Fan Operation] [Reverse Fan Operation]


SERVICE ↓ There are the following 4
screens.
Refer to ↓
“6.Service”
Default Screen STAND BY
↓ The fan is rotating to the
SERVICE
normal direction.
MAINTENANCE ▲
Press the OK key in order to
PASSWORD CHANGE change the direction of a fan
DIAGNOSTIC rotation.。
ECM INFO
STATUS ACTIVE
CALIBRATIONS ▼ The fan is rotating to the
PRESS TO CHANGE reverse direction.
MAINTE INFO
Press the left key in order to
return to the normal
direction of a fan rotation.
/ :MOVE CURSOR
↓ ABORT
The fan is changing the
direction of a fan rotation

from reverse direction to
MAINTENANCE
normal direction.
REVERSE FAN ▲
FLTR/FLUID INFO
RECOMMEND INTERVAL FAILED
WORK HOUR INFO Read the service manual.


PRESS TO START
REVERSE FAN

/ :MOVE CURSOR

24
Monitoring System Operation Manual

[STAND BY] [FAILED]


REVERSE FAN REVERSE FAN
FAILED
-NOT INSTALLED
STAND BY -HYD OIL TEMP HIGH
-COOLANT TEMP HIGH
-HYD LOCK OFF
-SOL MALFUNCTION
PRESS TO START
REVERSE FAN MODE

:BACK :BACK

[ACTIVE]
REVERSE FAN

ACTIVE

PRESS TO CANCEL
REVERSE FAN MODE

:BACK

[ABORT]
REVERSE FAN

ABORT

:BACK

25
Monitoring System Operation Manual

6.1.2. Filter/Fluid Information USER PASSWORD REQUIRED


( MAIN MENU → SERVICE → MAINTENANCE → FLTR/FLUID INFO )

Go to the
FLTR/FLUID INFO [Reset Accumulated Hour]
MAINTENACE
ENGINE OIL FILTER ▲ Press the up key or down
XXXX/YYYY[HR] key in order to highlite
HYD OIL RET FILTER desired item.
Refer to
XXXX/YYYY[HR]
“6.1.1.Reverse Fan”
PILOT OIL FILTER
↓ XXXX/YYYY[HR] ▼ Press the OK key in order to
MAINTENANCE PRESS TO CHANGE move cursor to accumulated
REVERSE FAN ▲ DATA hour position.
FLTR/FLUID INFO
RECOMMEND INTERVAL FLTR/FLUID INFO
WORK HOUR INFO ENGINE OIL FILTER ▲
/ :MOVE CURSOR XXXX/YYYY[HR]
▼ ↓ HYD OIL RET FILTER
PRESS TO START [Reset Accumulated Hour] XXXX/YYYY[HR]
REVERSE FAN PILOT OIL FILTER

XXXX/YYYY[HR] ▼
PRESS TO SET
↓ CHANGED DATA
/ :MOVE CURSOR Default Screen

:CANCEL
:RESET HOUR

MAINTENANCE
REVERSE FAN ▲
FLTR/FLUID INFO
Press the left key in order to
RECOMMEND INTERVAL reset the accumulated hour.
WORK HOUR INFO
Then, press the OK key in
▼ order to set the reseted hour.
PRESS TO RESET
FLTR/FLUID INFO If you press the back key
before the OK key, then the
reset hour is not stored.
/ :MOVE CURSOR

26
Monitoring System Operation Manual

6.1.3. Recommend Interval SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → MAINTENANCE → RECOMMEND INTERVAL )

Go to the
RECOMMEND INTERVAL [Change Recommended
MAINTENACE
ENGINE OIL FILTER ▲ Interval]
XXXX/YYYY[HR] Press the up key or down
HYD OIL RET FILTER key in order to highlite
Refer to
XXXX/YYYY[HR]
“6.1.1.Reverse Fan” desired item.
PILOT OIL FILTER
↓ XXXX/YYYY[HR] ▼
MAINTENANCE PRESS TO CHANGE Press the OK key in order to
REVERSE FAN ▲ DATA move cursor to the
FLTR/FLUID INFO recommended interval
RECOMMEND INTERVAL position.
WORK HOUR INFO
/ :MOVE CURSOR RECOMMEND INTERVAL
▼ ↓ ENGINE OIL FILTER ▲
PRESS TO START [Change Recommended XXXX/YYYY[HR]
REVERSE FAN Interval] HYD OIL RET FILTER
XXXX/YYYY[HR]

PILOT OIL FILTER
XXXX/YYYY[HR] ▼
/ :MOVE CURSOR ↓ PRESS TO SET
↓ Default Screen CHANGED DATA

↓ :CANCEL
MAINTENANCE / :+/-
REVERSE FAN ▲
FLTR/FLUID INFO
RECOMMEND INTERVAL Press the up key or the
WORK HOUR INFO down key in order to
increase or decrease the
▼ recommended intervals.
PRESS TO CHANGE
RECOMMEND INTERVAL Press the OK key in order to
store the changed values.

If you press the back key


/ :MOVE CURSOR
before the OK key, then the
↓ changed hour is not stored.

27
Monitoring System Operation Manual

6.1.4. Work Hour Info SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → MAINTENANCE → WORK HOUR INFO )

Go to the
WORK HOUR INFO [Reset Work Hour]
MAINTENACE
ENGINE ▲ Press the up key or down
XXXX[HR] key in order to highlite
PUMP desired item.
Refer to
XXXX[HR]
“6.1.1.Reverse Fan”
TRAVEL MOTOR
↓ XXXX[HR] ▼ Press the OK key in order to
MAINTENANCE PRESS TO CHANGE move cursor to work hour
REVERSE FAN ▲ DATA position.
FLTR/FLUID INFO
RECOMMEND INTERVAL WORK HOUR INFO
WORK HOUR INFO ENGINE ▲
/ :MOVE CURSOR XXXX[HR]
▼ ↓ PUMP
PRESS TO START [Reset Work Hour] XXXX[HR]
REVERSE FAN TRAVEL MOTOR

XXXX[HR] ▼
PRESS TO SET
↓ CHANGED DATA
/ :MOVE CURSOR Default Screen

:CANCEL
:RESET HOUR

MAINTENANCE
Press the left key in order to
REVERSE FAN ▲
FLTR/FLUID INFO
reset the accumulated hour.
RECOMMEND INTERVAL
WORK HOUR INFO Then, press the OK key in
order to set the reseted hour.

PRESS TO RESET If you press the back key
WORK HOUR INFO before the OK key, then the
reset hour is not stored.

/ :MOVE CURSOR

28
Monitoring System Operation Manual

6.2. Password Change USER PASSWORD REQUIRED


( MAIN MENU → SERVICE → PASSWORD CHANGE )

Go to the
PASSWORD [Enter New Password]
SERVICE
ENTER NEW PASSWORD Press the right key or the
left key in order to highlight
_ _ _ _ desired letter.
Refer to
“6.Service”
CDEF01234
↓ Press the OK key in order to
SERVICE PRESS TO ENTER set a highlighted letter.
MAINTENANCE ▲ HIGHLIGHTED LETTER
PASSWORD CHANGE Press the back key in order
DIAGNOSTIC to delete a selected letter.
ECM INFO :DELETE
STATUS / :MOVE CURSOR When you enter 4 letters,
CALIBRATIONS ▼ ↓ then the confirmation screen
PRESS TO CHANGE [Enter New Password] is displayed.
MAINTE INFO ↓
[Confirmation Screen]
PASSWORD

ENTER NEW PASSWORD
/ :MOVE CURSOR Default Screen
↓ * * * *

↓ ARE YOU SURE?


SERVICE
MAINTENANCE ▲
PASSWORD CHANGE
DIAGNOSTIC
ECM INFO
STATUS :SET
CALIBRATIONS ▼ :CANCEL
PRESS TO CHANGE
PASSWORD Press the OK key in order to
store new password.

If you press the back key


/ :MOVE CURSOR before the OK key, then the
↓ new password is not stored.

29
Monitoring System Operation Manual

6.3. Diagnostic SERVICE PASSWORD REQUIRED


6.3.1. Active Error
( MAIN MENU → SERVICE → DIAGNOSTIC → ACTIVE ERROR )

Go to the
DIAGNOSTIC [Active Error List]
SERVICE
ACTIVE ERROR ▲ Active error is displayed as
LOGGED ERROR the following format.
LOGGED EVENT
Refer to
“6.Service” MID : CID – FMI
↓ ▼
PRESS TO CHECK MID:
SERVICE
MAINTENANCE ▲ ACTIVE ERROR INFO Control Module ID which
PASSWORD CHANGE detected error component
DIAGNOSTIC
ECM INFO CID:
STATUS / :MOVE CURSOR Component ID estimated
CALIBRATIONS ▼ ↓ with error status
PRESS TO CHANGE
[Active Error List]
MAINTE INFO FMI:

Failure Mode ID

Refer to the appendix about
/ :MOVE CURSOR Default Screen
↓ MID, CID, FMI code.

[Active Error Screen]


↓ ACTIVE ERROR
SERVICE MMM : CCCC – FF ▲
MAINTENANCE ▲ MMM : CCCC - FF
PASSWORD CHANGE MMM : CCCC – FF
DIAGNOSTIC MMM : CCCC – FF
ECM INFO MMM : CCCC – FF
STATUS MMM : CCCC – FF ▼
CALIBRATIONS ▼ TOTAL
PRESS TO CHECK HHHHH ERROR
DIAGNOSTIC INFO

/ :SCROLL
/ :MOVE CURSOR

30
Monitoring System Operation Manual

6.3.2. Logged Error SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → DIAGNOSTIC → LOGGED ERROR )

[Logged Error List] [Detail]


Go to the
Logged error is displayed as Detail of logged error is
DIAGNOSTIC the following format. displayed as the following
Refer to
screen.
“6.3.1.Active Error” MID : CID – FMI
[Detail of Logged Error]
↓ MID: LOGGED ERROR
DIAGNOSTIC Control Module ID which MID : MMM ▲
ACTIVE ERROR ▲ CID : CCCC
detected error component
LOGGED ERROR FMI : FF
LOGGED EVENT OCC : OOOOO
CID:
FIRST : FFFFF
Component ID estimated LAST : LLLLL ▼
▼ with error status DIAGNOSTIC CLOCK
PRESS TO CHECK HHHHH [HR]
ACTIVE ERROR INFO FMI:
Failure Mode ID

Refer to the appendix about :DELETE THIS DATA


/ :MOVE CURSOR
MID, CID, FMI code.
↓ OCC:
Press the up key or the The number of times the
↓ down key in order to error occurred
DIAGNOSTIC highlight desired item.
ACTIVE ERROR ▲ FIRST:
LOGGED ERROR Press the OK key in order to The first time the error
LOGGED EVENT see the detail of logged occurred
error.
LAST:

[Logged Error List] The last time the error
PRESS TO CHECK
LOGGED ERROR occurred
LOGGED ERROR INFO
MMM : CCCC – FF ▲
MMM : CCCC – FF
MMM : CCCC - FF
/ :MOVE CURSOR MMM : CCCC – FF
MMM : CCCC – FF
↓ MMM : CCCC – FF ▼
[Logged Error List / Detail / TOTAL
Delete Log] HHHHH ERROR

:DETAIL
↓ / :SCROLL
Default Screen

31
Monitoring System Operation Manual

[Delete Log]
When you press the OK key
in the detail screen, then the
delete confirmation screen
is displayed.

If you want to delete this log,


move a cursor to "YES" by
pressing the right key or the
left key.

Then press the OK key in


order to delete this log.

[Confirmation Screen]
LOGGED ERROR

DELETE THIS DATA ?

MMM : CCCC – FF

YES / NO ▼

:ENTER
/ :MOVE CURSOR

32
Monitoring System Operation Manual

6.3.3. Logged Event SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → DIAGNOSTIC → LOGGED EVENT )

[Logged Event List] [Detail]


Go to the
Logged event is displayed Detail of logged event is
DIAGNOSTIC as the following format. displayed as the following
Refer to
screen.
“6.3.1.Active Error” MID : EID - LEVEL
[Detail of Logged Event]
↓ MID: LOGGED EVENT
DIAGNOSTIC Control Module ID which MID : MMM ▲
ACTIVE ERROR ▲ EID : EEEEEE
detected error component
LOGGED ERROR LEVEL : LL
LOGGED EVENT OCC : OOOOO
EID:
FIRST : FFFFF
Event ID LAST : LLLLL ▼
▼ DIAGNOSTIC CLOCK
PRESS TO CHECK LEVEL: HHHHH [HR]
ACTIVE ERROR INFO Warning Level

Refer to the appendix about


MID, EID code. :DELETE THIS DATA
/ :MOVE CURSOR
↓ Press the up key or the OCC:
x 2 down key in order to The number of times the
↓ highlight desired item. error occurred
DIAGNOSTIC
ACTIVE ERROR ▲ Press the OK key in order to FIRST:
LOGGED ERROR see the detail of logged The first time the error
LOGGED EVENT event. occurred

[Logged Event List] LAST:


▼ LOGGED EVENT The last time the error
PRESS TO CHECK MMM : EEEEEE - LL ▲ occurred
LOGGED EVENT INFO MMM : EEEEEE - LL
MMM : EEEEEE - LL
MMM : EEEEEE - LL
MMM : EEEEEE - LL
/ :MOVE CURSOR MMM : EEEEEE - LL ▼
↓ TOTAL
[Logged Event List / Detail / XXXXX EVENT
Delete Log]
↓ :DETAIL
/ :SCROLL

Default Screen
33
Monitoring System Operation Manual

[Delete Log]
When you press the OK key
in the detail screen, then the
delete confirmation screen
is displayed.

If you want to delete this log,


move a cursor to "YES" by
pressing the right key or the
left key.

Then press the OK key in


order to delete this log.

[Confirmation Screen]
LOGGED EVENT

DELETE THIS DATA ?

MMM :EEEEEE-LL

YES / NO ▼

:ENTER
/ :MOVE CURSOR

34
Monitoring System Operation Manual

6.4. ECM Info SERVICE PASSWORD REQUIRED


6.4.1. Machine ECM
( MAIN MENU → SERVICE → ECM INFO → MACHINE ECM )

Go to the
ECM INFO [ECM Information]
SERVICE
MACHINE ECM ▲ Press the up key or the
ENGINE ECM down key in order to see the
MONITOR following ECM information.
Refer to
ATT ECM
“6.Service”

↓ ▼
• Product ID
SERVICE PRESS TO SELECT • ECM Part Number
MAINTENANCE ▲ ECM • ECM Serial Number
PASSWORD CHANGE • Software Group Number
DIAGNOSTIC • Software Group
ECM INFO Release Date
STATUS / :MOVE CURSOR
CALIBRATIONS ▼ ↓
PRESS TO CHANGE
MAINTE INFO

MACHINE ECM
PRODUCT ID ▲
/ :MOVE CURSOR XXXXXXXX
↓ ECM PART NO
XXXXXXX-XX
ECM SERIAL NO
↓ XXXXXXXX ▼
SERVICE
MAINTENANCE ▲
PASSWORD CHANGE
DIAGNOSTIC
ECM INFO
STATUS / :SCROLL
CALIBRATIONS ▼ ↓
PRESS TO SEE
[ECM Information]
ECM INFORMATION


/ :MOVE CURSOR Default Screen

35
Monitoring System Operation Manual

6.4.2. Engine ECM SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → ECM INFO → ENGINE ECM )

Go to the
ECM INFO ENGINE ECM [ECM Information]
EQUIPMENT ID ▲ Press the up key or the
Refer to XXXXXXXX down key in order to see the
“6.4.1.Machine ECM” ENGINE SERIAL NO following ECM information.
XXXXXXXX
↓ ECM SERIAL NO
XXXXXXXX ▼ • Equipment ID
ECM INFO
MACHINE ECM ▲
• Engine Serial Number
ENGINE ECM • ECM Serial Number
MONITOR • Module Part Number
ATT ECM

▼ / :SCROLL
PRESS TO SELECT ↓
ECM [ECM Information]

/ :MOVE CURSOR ↓
↓ Default Screen


ECM INFO
MACHINE ECM ▲
ENGINE ECM
MONITOR
ATT ECM


PRESS TO SELECT
ECM

/ :MOVE CURSOR

36
Monitoring System Operation Manual

6.4.3. Monitor SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → ECM INFO → MONITOR )

Go to the
MONITOR [ECM Information]
ECM INFO
ECM PART NO ▲ Press the up key or the
XXXXXXX-XX down key in order to see the
ECM SERIAL NO following ECM information.
Refer to XXXXXXXX
“6.4.1.Machine ECM” SOFTWARE PART NO
XXXXXXX-XX ▼ • ECM Part Number

• ECM Serial Number
ECM INFO
MACHINE ECM ▲
• Software Part Number
ENGINE ECM
MONITOR
ATT ECM
/ :SCROLL
▼ ↓
PRESS TO SELECT [ECM Information]
ECM ↓


/ :MOVE CURSOR Default Screen


ECM INFO
MACHINE ECM ▲
ENGINE ECM
MONITOR
ATT ECM


PRESS TO SELECT
ECM

/ :MOVE CURSOR

37
Monitoring System Operation Manual

6.4.4. Attachment ECM (345C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → ECM INFO → ATT ECM )

Go to the
ATT ECM [ECM Information]
ECM INFO
ECM PART NO ▲ Press the up key or the
XXXXXXX-XX down key in order to see the
ECM SERIAL NO following ECM information.
Refer to XXXXXXXX
“6.4.1.Machine ECM” SOFTWARE PART NO
XXXXXXX-XX ▼ • ECM Part Number

• ECM Serial Number
ECM INFO
MACHINE ECM ▲
• Software Group Number
ENGINE ECM • Software Group
MONITOR Release Date
ATT ECM
/ :SCROLL
▼ ↓
PRESS TO SELECT [ECM Information]
ECM ↓


/ :MOVE CURSOR Default Screen


ECM INFO
MACHINE ECM ▲
ENGINE ECM
MONITOR
ATT ECM


PRESS TO SELECT
ECM

/ :MOVE CURSOR

38
Monitoring System Operation Manual

6.5. Status SERVICE PASSWORD REQUIRED


6.5.1. Digital Input Status
( MAIN MENU → SERVICE → STATUS → DIGITAL IN STATUS )

Go to the
STATUS [Status Information List]
SERVICE
DIGITAL IN STATUS ▲ Press the OK key in order to
ANALOG IN STATUS check status information.l
OUTPUT STATUS
Refer to
MISC STATUS
“6.Service” Note: The indication item
↓ ▼
varies by the model. And
SERVICE PRESS TO SEE the item which is checked at
MAINTENANCE ▲ DIGITAL INPUTS the next table may not be
PASSWORD CHANGE STATUS INFORMATION indicated by the machine
DIAGNOSTIC configuration.
ECM INFO .
STATUS / :MOVE CURSOR
CALIBRATIONS ▼ ↓
PRESS TO CHANGE
MAINTE INFO

DIGITAL IN STATUS
AIR FLTR PLGD SW ▲
/ :MOVE CURSOR OK
↓ CAPSL FLTR PLGD SW
PLUGGED
BACKUP SW
↓ OFF ▼
SERVICE
MAINTENANCE ▲
PASSWORD CHANGE
DIAGNOSTIC
ECM INFO
STATUS / :SCROLL
CALIBRATIONS ▼ ↓
PRESS TO SEE
[Status Information List]
STATUS INFORMATION


/ :MOVE CURSOR Default Screen

39
Monitoring System Operation Manual

Digital Input Status Prameter List (1/2)

365C/385C
345C
Display Description
AIR FLTR PLGD SW x x Air Filter Restriction Status
CAPSULE FLTR PLGD SW x x Return Hydraulic Oil Filter Status
ATT FLTR PLGD SW x x Attachment Hydraulic Oil Filter Switch Status
WATER SEP LVL SW x x Fuel/Water Separator Level Status
FUEL FLTR PLGD SW x x Engine Fuel Filter Status
2ND FUEL FLTR PLGD SW x x Secondary Fuel Filter Status
OLW ENABLE SW x x Machine Overload Warning Enable Switch Status
FINE SWING SW - x Fine Swing Switch Position
QUICK COUPLER SW - x Quick Coupler Switch Status
BACKUP SW - x Backup Mode Status
TRAVEL MODE SW x x Travel Mode Switch Status
AEC MODE SW x x AESC Resolver Switch Status
ALARM CANCEL SW x x Operator Travel Alarm Switch
TOOL SELECT SW - x Tool Select Switch Status
GAIN/RES SELECT SW x - Gain/Response Select Switch Status
LIFT/CRANE MODE SW x x Heavy lift switch status
AUTO LUB LOW LVL SW x - Auto Lube Grease Level
ONE TOUCH LOW IDLE SW x x Low Idle Switch Position
MANUAL LUB SW x - Reel Lube Switch Position
LEFT JOYSTICK SW #1 x x Left Joystick Switch #1 Status
RIGHT JOYSTICK SW #1 x x Right Joystick Switch #1 Status
LEFT JOYSTICK SW #2 x x Left Joystick Switch #2 Status
RIGHT JOYSTICK SW #2 x x Right Joystick Switch #2 Status
ATCH PUMP PRES SW x - Attachment Pump Pressure Switch Status
JOYSTK SW #2 x - Joystick Switch #2 Status
JOYSTK SW #3 x - Joystick Switch #3 Status
FLCN PRXI SW #1 x - Flow Control Proximity Switch #1 Status
FLCN PRXI SW #2 x - Flow Control Proximity Switch #2 Status
MAGNET STANDBY SW x - Magnet Circuit Standby Switch Status
UHD SW x - High Power Auxiliary Circuit Enable Switch Status
TILT CAB SW x - Low Power Auxiliary Circuit Enable Switch Status
SMART BOOM SW x - Smart Boom Switch Status
HYD LOCK SW x x Hydraulic Lock Switch Status

40
Monitoring System Operation Manual

Digital Input Status Prameter List (2/2)

365C/385C
345C
Display Description
CNTR WEIGHT SW x x Counterweight Removal Switch Status
JOYSTICK PRES SW - x Swing/Implement Pressure Status
TRAVEL PRES SW - x Travel Pressure Switch Status
IMPLEMENT PRES - x Implement pressure switch status
ATCH VALVE #1 SW - x Attachment Input #1 Switch Status
ATCH VALVE #3 SW - x Attachment Input #3 Switch Status
ATCH #1 TOOL SW - x Attachment #1 Tool Switch Status
ATCH #2 TOOL SW - x Attachment #2 Tool Switch Status
ATCH #3 TOOL SW - x Attachment #3 Tool Switch Status
ATCH #4 TOOL SW - x Attachment #4 Tool Switch Status
HYD OIL LVL SW x x Hydraulic Oil Level Status
COOLANT LVL SW x x Engine Coolant Level Status
ENGINE OIL LVL SW x x Engine Oil Level Status
ENGINE OIL PRESS SW x x Engine Oil Pressure Status
START AID SW x - Ether Injection Switch Position
USER SHUTDOWN SW x x User Defined Shutdown Status

41
Monitoring System Operation Manual

6.5.2. Analog Input Status SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → STATUS → ANALOG IN STATUS )

ANALOG IN STATUS
Go to the
BATTERY VOLTAGE ▲
STATUS 27.8[V]
ENGINE SPEED
Refer to
1980[RPM]
“6.5.1.Dital Input Status”
THROTTLE POSITION
↓ 10 ▼
STATUS
DIGITAL IN STATUS ▲
ANALOG IN STATUS
OUTPUT STATUS
MISC STATUS
/ :SCROLL
▼ ↓
PRESS TO SEE [Status Information List]
DIGITAL INPUTS ↓
STATUS INFORMATION


/ :MOVE CURSOR Default Screen


STATUS [Status Information List]
DIGITAL IN STATUS ▲ Press the OK key in order to
ANALOG IN STATUS check status information.l
OUTPUT STATUS
MISC STATUS Note: The indication item
varies by the model. And

the item which is checked at
PRESS TO SEE
the next table may not be
ANALOG INPUTS
STATUS INFORMATION indicated by the machine
configuration.

/ :MOVE CURSOR

42
Monitoring System Operation Manual

Analog Input Status Prameter List (1/1)

365C/385C
345C
Display Description
BATTERY VOLTAGE x x Battery Voltage
ENGINE SPEED x x Actual Engine Speed
THROTTLE POSITON x x Throttle Dial Switch Position
FUEL LEVEL SENSOR x x Fuel Level Percent
COOLANT TEMP x x Engine Coolant Temperature
HYD OIL TEMP x x Hydraulic Oil Temperature
PUMP #1 PRES x Hydraulic Pump #1 Outlet Pressure
PUMP #2 PRES x Hydraulic Pump #2 Outlet Pressure
MAIN PUMP PRES x Variable Implement Pump Oil Pressure
SWING PUMP PRES x Swing Pump Outlet Pressure
OVERLOAD WARN PRES x x Machine Overload Warning Pressure
LEVER BOOM x Boom Lever Position
LEVER BUCKET x Bucket Lever Position
LEVER STICK x Stick Lever Position
LEVER SWING x Swing Lever Position
TRV LEFT PEDAL x Left Travel Position
TRV RIGHT PEDAL x Right Travel Position
LEFT THUMBWHEEL x x Left Joystick Thumbwheel Position
RIGHT THUMBWHEEL x x Right Joystick Thumbwheel Position
JOYSTK SW #1(PROP) x Joystick Switch #1 Status
JOYSTK SW #4(PROP) x Joystick Switch #4 Status
ATCH LEFT PEDAL x Left Attachment Pedal Position
ATCH RIGHT PEDAL x Right Attachment Pedal Positio
ATCH PEDAL x Attachment Pedal Position
ATMOSPHELIC PRES x x Atmospheric Pressure
AUTO LUB PRESS x Auto Lube Pressure
INTAKE AIR TEMP x x Intake Manifold Air Temperature
FUEL TEMP x x Fuel Temperature
FUEL PRES x x Fuel Pressure
FUEL PRES (ABS) x x Fuel Pressure (absolute)
ENG OIL PRES x x Engine Oil Pressure
ENG OIL PRES (ABS) x x Engine Oil Pressure (absolute)
TURBO OUT PRES (ABS) x x Turbo Outlet Pressure (absolute)
BOOST PRES x x Boost Pressure
STRAIGHT TRV PEDAL x Straight Travel Position

43
Monitoring System Operation Manual

6.5.3. Output Status SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → STATUS → OUTPUT STATUS )

OUTPUT STATUS
Go to the
TRAVEL SPEED SHIFT ▲
STATUS OFF
SWING BREAK SOL
Refer to
OFF
“6.5.1.Dital Input Status”
LIFT MODE SOL
↓ OFF ▼
STATUS
DIGITAL IN STATUS ▲
ANALOG IN STATUS
OUTPUT STATUS
MISC STATUS
/ :SCROLL
▼ ↓
PRESS TO SEE [Status Information List]
DIGITAL INPUTS ↓
STATUS INFORMATION


/ :MOVE CURSOR Default Screen


STATUS [Status Information List]
DIGITAL IN STATUS ▲ Press the OK key in order to
ANALOG IN STATUS check status information.l
OUTPUT STATUS
MISC STATUS
Note: The indication item

varies by the model. And
PRESS TO SEE the item which is checked at
OUTPUT the next table may not be
STATUS INFORMATION indicated by the machine
configuration.

/ :MOVE CURSOR

44
Monitoring System Operation Manual

Output Status Parameter List (1/2)

365C/385C
345C
Display Description
HYD LOCK SOL x - Hydraulic Lock Solenoid Status
TRV SPEED SHIFT x x Travel Speed Solenoid
SWING BREAK SOL x x Swing Brake Solenoid Status
TRV ALARM x x Travel Alarm Control Status
SYSTEM PRES UP x - Front System High Pressure Solenoid Status
NUTRAL FLOW BYPASS x - Neutral Flow Bypass Solenoid Status
ANTI DRIFT BOOM x - Boom Anti Drift Solenoid Status
ANTI DRIFT STICK x - Stick Anti Drift Solenoid Status
AUTO LUB RELAY x - Auto Lube Solenoid Status
COOLING FAN CURRENT x - Fan Speed Solenoid Current Status
REVERSE FAN SOL x x Reverse Fan Solenoid Status
LIFT MODE SOL - x Heavy Lift Control Status
1P/2P CHANGE SOL - x Auxiliary Circuit Flow Combining Solenoid Status
FAULT ALARM x x Action Alarm Status
DESIRED ENG SPEED x x Desired Engine RPM
BOOM EXTEND x - Boom Cylinder Rod Extend Solenoid Current
BOOM RETRACT x - Boom Cylinder Rod Retract Solenoid Current
STICK EXTEND x - Stick cylinder Rod Extend Solenoid Current
STICK RETRACT x - Stick cylinder Rod Retract Solenoid Current
BUCKET EXTEND x - Bucket cylinder Rod Extend Solenoid Current
BUCKET RETRACT x - Bucket cylinder Rod Retract Solenoid Current
SWING LEFT x - Swing Left Solenoid Current
SWING RIGHT x - Swing Right Solenoid Current
TRAVEL LEFT FW x - Left Travel Forward Solenoid Current Status
TRAVEL LEFT BW x - Left Travel Backward Solenoid Current Status
TRAVEL RIGHT FW x - Right Travel Forward Solenoid Current Status
TRAVEL RIGHT BW x - Right Travel Backward Solenoid Current Status
BM LOWERING CHECK x - Boom Lowering Check Valve Solenoid Current Status
ST LOWERING CHECK x - Stick Lowering Check Valve Solenoid Current Status
ATCH EXTEND x - Attachment Extend/CW Solenoid Current Status
ATCH RETRACT x - Attachment Retract/CCW Solenoid Current Status
MID CIRCUIT #1-A x - Medium Pressure Circuit #1-A Solenoid Current Status
MID CIRCUIT #1-B x - Medium Pressure Circuit #1-B Solenoid Current Status
POWER SHIFT PRES x - Implement Pump Power Shift Pressure Solenoid Current Status
POWER SHIFT PRES - x Power Shift Pressure
DESIRED PS PRESS x - Desired Implement Pump Power Shift Pressure

45
Monitoring System Operation Manual

Output Status Parameter List (2/2)

365C/385C
345C
Display Description
FLOW LIMIT PRES - x Main Pump Flow Limitation Pressure
FLOW LIMIT - x Main Pump Flow Limit
SWING PUMP SWASH x - Swing Pump Swash Plate Angle Solenoid Current Status
FAN MOTOR SPEED - x Desired Engine Cooling Fan Speed
ATCH #1 EXTEND VALVE - x Attachment Valve #1 Extend Pressure Command
ATCH #1 RETRACT VALVE - x Attachment Valve #1 Retract Pressure Command
ATCH #3 EXTEND VALVE - x Attachment Valve #3 Extend Pressure Command
ATCH #3 RETRACT VALVE - x Attachment Valve #3 Retract Pressure Command
RELIEF CHK SOL #1 - x Relief Valve Check Solenoid #1
RELIEF CHK SOL #2 - x Relief Valve Check Solenoid #2
ATCH #1 RELEAF VALVE - x Variable Relief Valve #1 Pressure Command
ATCH #2 RELEAF VALVE - x Variable Relief Valve #2 Pressure Command

46
Monitoring System Operation Manual

6.5.4. Misc Status SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → STATUS → MISC STATUS )

MISC STATUS
Go to the
ALTERNATOR R TERM ▲
STATUS OK
FUEL CONSUMPTION
Refer to
10.5[L/h]
“6.5.1.Dital Input Status”
ENG POWER DERATE
↓ ON ▼
STATUS
DIGITAL IN STATUS ▲
ANALOG IN STATUS
OUTPUT STATUS
MISC STATUS
/ :SCROLL
▼ ↓
PRESS TO SEE [Status Information List]
DIGITAL INPUTS ↓
STATUS INFORMATION


/ :MOVE CURSOR Default Screen


STATUS [Status Information List]
DIGITAL IN STATUS ▲ Press the OK key in order to
ANALOG IN STATUS check status information.l
OUTPUT STATUS
MISC STATUS
Note: The indication item

varies by the model. And
PRESS TO SEE the item which is checked at
MISC the next table may not be
STATUS INFORMATION indicated by the machine
configuration.

/ :MOVE CURSOR

47
Monitoring System Operation Manual

Misc Parameter List (1/1)

365C/385C
345C
Display Description
ALTERNATOR R TERM x x Alternator Status
DES ENG FAN SP x Desired Engine Cooling Fan Speed
UHD FLOW RATE x High Power Auxiliary Circuit Flow Rate
SPOOL GAIN SEL x Spool Gain Selection
SPOOL RES SEL x Spool Response Selection
AEC MODE STAT x Automatic Engine Control Mode
WORK MODE x Machine Work Mode
TRAVEL MODE x Travel Speed Shift Setting
AUTO LUB MODE x Machine Auto Lube Control Mode
ENGINE DIAG CLOCK x Engine ECM Diagnostic Clock
ONE TOUCH IDOL ST x One Touch Low Idle Feature Status
START AID STATUS x Ether Injection
TOTAL FUEL x Total Fuel
FUEL CONSUMPTION x x Fuel Consumption Rate
RATED FUEL LIMIT x Torque Rack Limit
FRC FUEL LIMIT x Effective Smoke Rack Limit
ENG LOAD FACTOR x Percent Engine Load at Current Engine Speed
ENG POWER DERATE x x Engine Power Derate Percentage

48
Monitoring System Operation Manual

6.6. Calibrations SERVICE PASSWORD REQUIRED


6.6.1. Control Valves
6.6.1.1. All Valves (365C/385C)
( MAIN MENU → SERVICE → CALIBRATIONS → CONTROL VALVES → ALL VALVES )

Go to the
CALIBRATIONS [Calibration]
SERVICE
CONTROL VALVES ▲ In the calibration screen,
RELIEF VALVES step number is displayed in
PS PRES VALVE blue.
Refer to
FLOW LIMIT VALVE
“6.Service”
CHECK VALVES
↓ LEVER/PEDAL/ATCH ▼
Perform the operation
PRESS TO PERFORM written in the following table
SERVICE
MAINTENANCE ▲ CALIBRATION in each step.
PASSWORD CHANGE
DIAGNOSTIC [Calibration Screen]
ECM INFO CALIBRATION TITLE
STATUS / :MOVE CURSOR
CALIBRATIONS ▼ ↓ STEP No: STEP NAME
PRESS TO CHANGE
MAINTE INFO
↓ S E
CONTROL VALVES
ALL VALVE ▲ OPERATION GUIDANCE
BOOM VALVE
/ :MOVE CURSOR
STICK VALVE
↓ BUCKET VALVE
RIGHT TRV VALVE
↓ LEFT TRV VALVE ▼ / :SCROLL
SERVICE PRESS TO PERFORM
PASSWORD CHANGE CALIBRATION
▲ S: Start step number
DIAGNOSTIC
E: End step number
ECM INFO
STATUS
CALIBRATIONS / :MOVE CURSOR
DEVICE TEST ▼ ↓
PRESS TO PERFORM
CALIBRATION

[Calibration]

/ :MOVE CURSOR
↓ ↓
Default Screen

49
Monitoring System Operation Manual

Step Operation
01 Press the OK key in
order to go the next.
02 Raise boom and stick
to the max position.
Then press the OK
key.
03 Set the hydraulic oil
lever to unlock
position.
04 Press the OK key in
order to go the next.
05 Hold left lever back.
06 Hold left lever back.
07 Press the OK key in
order to go the next.
08 Hold left lever back.
09 Hold left lever back.
10 Hold left lever back.
11 Hold left lever back.
12 Release all levers
and pedals.
13 Press the OK key in
order to go the next.
14 End of calibration.

Note: The step of the upper


table may be omitted
corresponding to the
condition.

50
Monitoring System Operation Manual

6.6.1.2. Boom Valve (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → CONTROL VALVES → BOOM VALVE )

Go to the ↓ Step Operation


CONTROL VALVES 01 Press the OK key in
↓ order to go the next.
Refer to Default Screen 02 Raise boom and stick
“6.6.1.1.All Valves” to the max position.
↓ Then press the OK
key.
CONTROL VALVES [Calibration]
ALL VALVE 03 Set the hydraulic oil

In the calibration screen,
BOOM VALVE lever to unlock
step number is displayed in
STICK VALVE position.
blue.
BUCKET VALVE 04 Press the OK key in
RIGHT TRV VALVE order to go the next.
LEFT TRV VALVE ▼ Perform the operation
written in the following table 05 Hold Left lever back.
PRESS TO PERFORM
in each step. 06 Release all levers
CALIBRATION
and pedals.
[Calibration Screen] 07 Press the OK key in
CALIBRATION TITLE order to go the next.
/ :MOVE CURSOR 08 End of calibration.
↓ STEP No: STEP NAME
Note: The step of the upper
↓ table may be omitted
S E
CONTROL VALVES corresponding to the
ALL VALVE ▲ condition.
OPERATION GUIDANCE
BOOM VALVE
STICK VALVE
BUCKET VALVE
RIGHT TRV VALVE
LEFT TRV VALVE ▼
/ :SCROLL
PRESS TO PERFORM
CALIBRATION

S: Start step number


E: End step number
/ :MOVE CURSOR


[Calibration]

51
Monitoring System Operation Manual

6.6.1.3. Stick Valve (365C/385C) SERVICE PASSWORD REQUIRED


REQUIRED
( MAIN MENU → SERVICE → CALIBRATIONS → CONTROL VALVES → STICK VALVE )

Go to the ↓ Step Operation


CONTROL VALVES 01 Press the OK key in
↓ order to go the next.
Refer to Default Screen 02 Raise boom and stick
“6.6.1.1.All Valves” to the max position.
↓ Then press the OK
key.
CONTROL VALVES [Calibration]
ALL VALVE 03 Set the hydraulic oil

In the calibration screen,
BOOM VALVE lever to unlock
step number is displayed in
STICK VALVE position.
blue.
BUCKET VALVE 04 Press the OK key in
RIGHT TRV VALVE order to go the next.
LEFT TRV VALVE ▼ Perform the operation
written in the following table 05 Hold Left lever back.
PRESS TO PERFORM
in each step. 06 Release all levers
CALIBRATION
and pedals.
[Calibration Screen] 07 Press the OK key in
CALIBRATION TITLE order to go the next.
/ :MOVE CURSOR 08 End of calibration.
↓ STEP No: STEP NAME
Note: The step of the upper
↓ table may be omitted
S E
CONTROL VALVES corresponding to the
ALL VALVE ▲ condition.
OPERATION GUIDANCE
BOOM VALVE
STICK VALVE
BUCKET VALVE
RIGHT TRV VALVE
LEFT TRV VALVE ▼
/ :SCROLL
PRESS TO PERFORM
CALIBRATION

S: Start step number


E: End step number
/ :MOVE CURSOR


[Calibration]

52
Monitoring System Operation Manual

6.6.1.4. Bucket Valve (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → CONTROL VALVES → BUCKET VALVE )

Go to the ↓ Step Operation


CONTROL VALVES 01 Press the OK key in
↓ order to go the next.
Refer to Default Screen 02 Raise boom and stick
“6.6.1.1.All Valves” to the max position.
↓ Then press the OK
key.
CONTROL VALVES [Calibration]
ALL VALVE 03 Set the hydraulic oil

In the calibration screen,
BOOM VALVE lever to unlock
step number is displayed in
STICK VALVE position.
blue.
BUCKET VALVE 04 Press the OK key in
RIGHT TRV VALVE order to go the next.
LEFT TRV VALVE ▼ Perform the operation
written in the following table 05 Press the OK key in
PRESS TO PERFORM
in each step. order to go the next.
CALIBRATION
06 Hold Left lever back.
[Calibration Screen] 07 Release all levers
CALIBRATION TITLE and pedals.
/ :MOVE CURSOR 08 Press the OK key in
↓ STEP No: STEP NAME order to go the next.
09 End of calibration.
↓ S E
CONTROL VALVES Note: The step of the upper
ALL VALVE ▲
OPERATION GUIDANCE
table may be omitted
BOOM VALVE corresponding to the
STICK VALVE condition.
BUCKET VALVE
RIGHT TRV VALVE
LEFT TRV VALVE ▼
/ :SCROLL
PRESS TO PERFORM
CALIBRATION

S: Start step number


E: End step number
/ :MOVE CURSOR


[Calibration]

53
Monitoring System Operation Manual

6.6.1.5. Right Travel Valve (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → CONTROL VALVES → RIGHT TRV VALVE )

Go to the ↓ Step Operation


CONTROL VALVES 01 Press the OK key in
↓ order to go the next.
Refer to Default Screen 02 Raise boom and stick
“6.6.1.1.All Valves” to the max position.
↓ Then press the OK
key.
CONTROL VALVES [Calibration]
ALL VALVE 03 Set the hydraulic oil

In the calibration screen,
BOOM VALVE lever to unlock
step number is displayed in
STICK VALVE position.
blue.
BUCKET VALVE 04 Press the OK key in
RIGHT TRV VALVE order to go the next.
LEFT TRV VALVE ▼ Perform the operation
written in the following table 05 Hold Left lever back.
PRESS TO PERFORM
in each step. 06 Release all levers
CALIBRATION
and pedals.
[Calibration Screen] 07 Press the OK key in
CALIBRATION TITLE order to go the next.
/ :MOVE CURSOR 08 End of calibration.
↓ STEP No: STEP NAME
Note: The step of the upper
↓ table may be omitted
S E
CONTROL VALVES corresponding to the
ALL VALVE ▲ condition.
OPERATION GUIDANCE
BOOM VALVE
STICK VALVE
BUCKET VALVE
RIGHT TRV VALVE
LEFT TRV VALVE ▼
/ :SCROLL
PRESS TO PERFORM
CALIBRATION

S: Start step number


E: End step number
/ :MOVE CURSOR


[Calibration]

54
Monitoring System Operation Manual

6.6.1.6. Left Travel Valve (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → CONTROL VALVES → LEFT TRV VALVE )

Go to the ↓ Step Operation


CONTROL VALVES 01 Press the OK key in
↓ order to go the next.
Refer to Default Screen 02 Raise boom and stick
“6.6.1.1.All Valves” to the max position.
↓ Then press the OK
key.
CONTROL VALVES [Calibration]
ALL VALVE 03 Set the hydraulic oil

In the calibration screen,
BOOM VALVE lever to unlock
step number is displayed in
STICK VALVE position.
blue.
BUCKET VALVE 04 Press the OK key in
RIGHT TRV VALVE order to go the next.
LEFT TRV VALVE ▼ Perform the operation
written in the following table 05 Hold Left lever back.
PRESS TO PERFORM
in each step. 06 Release all levers
CALIBRATION
and pedals.
[Calibration Screen] 07 Press the OK key in
CALIBRATION TITLE order to go the next.
/ :MOVE CURSOR 08 End of calibration.
↓ STEP No: STEP NAME
Note: The step of the upper
↓ table may be omitted
S E
CONTROL VALVES corresponding to the
ALL VALVE ▲ condition.
OPERATION GUIDANCE
BOOM VALVE
STICK VALVE
BUCKET VALVE
RIGHT TRV VALVE
LEFT TRV VALVE ▼
/ :SCROLL
PRESS TO PERFORM
CALIBRATION

S: Start step number


E: End step number
/ :MOVE CURSOR


[Calibration]

55
Monitoring System Operation Manual

6.6.1.7. Attachment Valve (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → CONTROL VALVES → ATCH VALVE )

Go to the ↓ Step Operation


CONTROL VALVES 01 Press the OK key in
↓ order to go the next.
Refer to Default Screen 02 Raise boom and stick
“6.6.1.1.All Valves” to the max position.
↓ Then press the OK
key.
CONTROL VALVES [Calibration]
ALL VALVE 03 Set the hydraulic oil

In the calibration screen,
BOOM VALVE lever to unlock
step number is displayed in
STICK VALVE position.
blue.
BUCKET VALVE 04 Press the OK key in
RIGHT TRV VALVE order to go the next.
LEFT TRV VALVE ▼ Perform the operation
written in the following table 05 Hold Left lever back.
PRESS TO PERFORM
in each step. 06 Release all levers
CALIBRATION
and pedals.
[Calibration Screen] 07 Press the OK key in
CALIBRATION TITLE order to go the next.
/ :MOVE CURSOR 08 End of calibration.
↓ STEP No: STEP NAME
Note: The step of the upper
↓ table may be omitted
S E
CONTROL VALVES corresponding to the
BOOM VALVE ▲ condition.
OPERATION GUIDANCE
STICK VALVE
BUCKET VALVE
RIGHT TRV VALVE
LEFT TRV VALVE
ATCH VALVE ▼
/ :SCROLL
PRESS TO PERFORM
CALIBRATION

S: Start step number


E: End step number
/ :MOVE CURSOR


[Calibration]

56
Monitoring System Operation Manual

6.6.1.8. Attachment Valve #1 Extend (345C/300D Phase 1) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → CONTROL VALVES → A1 VALVE EXTEND )

Go to the ↓ Step Operation


CONTROL VALVES 01 Connect the pressure
↓ gauge.
Refer to Default Screen Then press the OK
“6.6.1.1.All Valves” key in order to go the
↓ next.
02 Release all controls.
CONTROL VALVES [Calibration]
ALL VALVE Then press the OK

In the calibration screen,
BOOM VALVE key.
step number is displayed in
STICK VALVE 03 Hold the attachment
blue.
BUCKET VALVE controls to operating
RIGHT TRV VALVE position during
LEFT TRV VALVE Perform the operation
▼ calibration.
PRESS TO PERFORM written in the following table
Press the OK key.
CALIBRATION in each step.
04 Press the right key or
the left key in order to
[Calibration Screen]
CALIBRATION TITLE
increase or decrease
/ :MOVE CURSOR the current value.
↓ STEP No: STEP NAME And tune the
pressure to the
target.
↓ L U When you finish
CONTROL VALVES
STICK VALVE ▲
C tuning, press the OK
BUCKET VALVE
OPERATION GUIDANCE key.
RIGHT TRV VALVE 05 Same as step 03.
LEFT TRV VALVE 06 Same as step 04.
ATCH VALVE 07 Same as step 02.
A1 VALVE EXTEND ▼
/ :SCROLL 08 End of calibration
PRESS TO PERFORM
CALIBRATION
L: Lower limit Note: The step of the upper
U: Upper limit table may be omitted
C: Current value corresponding to the
/ :MOVE CURSOR condition.


[Calibration]

57
Monitoring System Operation Manual

6.6.1.9. Attachment Valve #1 Retract (345C/300D Phase 1) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → CONTROL VALVES → A1 VALVE RETRACT )

Go to the ↓ Step Operation


CONTROL VALVES 01 Connect the pressure
↓ gauge.
Refer to Default Screen Then press the OK
“6.6.1.1.All Valves” key in order to go the
↓ next.
02 Release all controls.
CONTROL VALVES [Calibration]
ALL VALVE Then press the OK

In the calibration screen,
BOOM VALVE key.
step number is displayed in
STICK VALVE 03 Hold the attachment
blue.
BUCKET VALVE controls to operating
RIGHT TRV VALVE position during
LEFT TRV VALVE Perform the operation
▼ calibration.
PRESS TO PERFORM written in the following table
Press the OK key.
CALIBRATION in each step.
04 Press the right key or
the left key in order to
[Calibration Screen]
CALIBRATION TITLE
increase or decrease
/ :MOVE CURSOR the current value.
↓ STEP No: STEP NAME And tune the
pressure to the
target.
↓ L U When you finish
CONTROL VALVES
BUCKET VALVE ▲
C tuning, press the OK
RIGHT TRV VALVE
OPERATION GUIDANCE key.
LEFT TRV VALVE 05 Same as step 03.
ATCH VALVE 06 Same as step 04.
A1 VALVE EXTEND 07 Same as step 02.
A1 VALVE RETRACT ▼
/ :SCROLL 08 End of calibration
PRESS TO PERFORM
CALIBRATION
L: Lower limit Note: The step of the upper
U: Upper limit table may be omitted
C: Current value corresponding to the
/ :MOVE CURSOR condition.


[Calibration]

58
Monitoring System Operation Manual

6.6.1.10. Attachment Valve #3 Extend (345C/300D Phase 1) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → CONTROL VALVES → A3 VALVE EXTEND )

Go to the ↓ Step Operation


CONTROL VALVES 01 Connect the pressure
↓ gauge.
Refer to Default Screen Then press the OK
“6.6.1.1.All Valves” key in order to go the
↓ next.
02 Release all controls.
CONTROL VALVES [Calibration]
ALL VALVE Then press the OK

In the calibration screen,
BOOM VALVE key.
step number is displayed in
STICK VALVE 03 Hold the attachment
blue.
BUCKET VALVE controls to operating
RIGHT TRV VALVE position during
LEFT TRV VALVE Perform the operation
▼ calibration.
PRESS TO PERFORM written in the following table
Press the OK key.
CALIBRATION in each step.
04 Press the right key or
the left key in order to
[Calibration Screen]
CALIBRATION TITLE
increase or decrease
/ :MOVE CURSOR the current value.
↓ STEP No: STEP NAME And tune the
pressure to the
target.
↓ L U When you finish
CONTROL VALVES
RIGHT TRV VALVE ▲
C tuning, press the OK
LEFT TRV VALVE
OPERATION GUIDANCE key.
ATCH VALVE 05 Same as step 03.
A1 VALVE EXTEND 06 Same as step 04.
A1 VALVE RETRACT 07 Same as step 02.
A3 VALVE EXTEND ▼
/ :SCROLL 08 End of calibration
PRESS TO PERFORM
CALIBRATION
L: Lower limit Note: The step of the upper
U: Upper limit table may be omitted
C: Current value corresponding to the
/ :MOVE CURSOR condition.


[Calibration]

59
Monitoring System Operation Manual

6.6.1.11. Attachment Valve #3 Retract (345C/300D Phase 1) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → CONTROL VALVES → A3 VALVE RETRACT )

Go to the ↓ Step Operation


CONTROL VALVES 01 Connect the pressure
↓ gauge.
Refer to Default Screen Then press the OK
“6.6.1.1.All Valves” key in order to go the
↓ next.
02 Release all controls.
CONTROL VALVES [Calibration]
ALL VALVE Then press the OK

In the calibration screen,
BOOM VALVE key.
step number is displayed in
STICK VALVE 03 Hold the attachment
blue.
BUCKET VALVE controls to operating
RIGHT TRV VALVE position during
LEFT TRV VALVE Perform the operation
▼ calibration.
PRESS TO PERFORM written in the following table
Press the OK key.
CALIBRATION in each step.
04 Press the right key or
the left key in order to
[Calibration Screen]
CALIBRATION TITLE
increase or decrease
/ :MOVE CURSOR the current value.
↓ STEP No: STEP NAME And tune the
pressure to the
target.
↓ L U When you finish
CONTROL VALVES
LEFT TRV VALVE ▲
C tuning, press the OK
ATCH VALVE
OPERATION GUIDANCE key.
A1 VALVE EXTEND 05 Same as step 03.
A1 VALVE RETRACT 06 Same as step 04.
A3 VALVE EXTEND 07 Same as step 02.
A3 VALVE RETRACT ▼
/ :SCROLL 08 End of calibration
PRESS TO PERFORM
CALIBRATION
L: Lower limit Note: The step of the upper
U: Upper limit table may be omitted
C: Current value corresponding to the
/ :MOVE CURSOR condition.


[Calibration]

60
Monitoring System Operation Manual

6.6.2. Relief Valves (345C/300D Phase 1) SERVICE PASSWORD REQUIRED


6.6.2.1. Attachment Relief Valve #1
( MAIN MENU → SERVICE → CALIBRATIONS → RELIEF VALVES → ATCH #1 RLF VALVE )

Go to the
RELIEF VALVES [Calibration]
CALIBRATIONS
ATCH #1 RLF VALVE ▲ In the calibration screen,
ATCH #2 RLF VALVE step number is displayed in
Refer to blue.
“6.6.1.1.All Valves”

↓ ▼
Perform the operation
CALIBRATIONS PRESS TO PERFORM written in the following table
CONTROL VALVES ▲ CALIBRATION in each step.
RELIEF VALVES
PS PRES VALVE Step Operation
FLOW LIMIT VALVE 01 Connect the pressure
/ :MOVE CURSOR
CHECK VALVES gauge.
LEVER/PEDAL/ATCH ▼ ↓ Then press the OK
PRESS TO PERFORM
key in order to go the
CALIBRATION
↓ next.
[Calibration] 02 Hold the tool controls
↓ to operating position
/ :MOVE CURSOR during calibration.
↓ ↓ Press the OK key.
Default Screen 03 Press the right key or
↓ the left key in order to
CALIBRATIONS
increase or decrease
CONTROL VALVES the current value.

[Calibration Screen] And tune the
RELIEF VALVES CALIBRATION TITLE
PS PRES VALVE pressure to the
FLOW LIMIT VALVE STEP No: STEP NAME target.
CHECK VALVES When you finish
LEVER/PEDAL/ATCH ▼ tuning, press the OK
PRESS TO PERFORM L U key.
CALIBRATION C 04 Same as step 02.
OPERATION GUIDANCE 05 Same as step 03.
06 Release all controls.
/ :MOVE CURSOR Then press the OK
↓ key.
/ :SCROLL 07 End of calibration

L: Lower limit Note: The step of the upper
U: Upper limit table may be omitted
C: Current value corresponding to the
condition.

61
Monitoring System Operation Manual

6.6.2.2. Attachment Relief Valve #2 SERVICE


SERVICE PASSWORD REQUIRED
( MAIN MENU → SERVICE → CALIBRATIONS → RELIEF VALVES → ATCH #2 RLF VALVE )

Go to the ↓ Step Operation


RELIEF VALVES 01 Connect the pressure
↓ gauge.
Refer to Default Screen Then press the OK
“6.6.2.1.Attachment key in order to go the
relief Valve #1” next.
↓ 02 Hold the tool controls
[Calibration]
RELIEF VALVES to operating position
In the calibration screen,
ATCH #1 RLF VALVE ▲ during calibration.
step number is displayed in
ATCH #2 RLF VALVE Press the OK key.
blue.
03 Press the right key or
the left key in order to
Perform the operation
increase or decrease
▼ written in the following table
the current value.
PRESS TO PERFORM in each step.
CALIBRATION
And tune the
pressure to the
target.
When you finish
/ :MOVE CURSOR [Calibration Screen] tuning, press the OK
CALIBRATION TITLE key.

04 Same as step 02.
STEP No: STEP NAME
↓ 05 Same as step 03.
RELIEF VALVES 06 Release all controls.
ATCH #1 RLF VALVE ▲ L U Then press the OK
ATCH #2 RLF VALVE C key.
OPERATION GUIDANCE 07 End of calibration

Note: The step of the upper



table may be omitted
PRESS TO PERFORM
/ :SCROLL
corresponding to the
CALIBRATION
condition.
L: Lower limit
U: Upper limit
/ :MOVE CURSOR C: Current value


[Calibration]

62
Monitoring System Operation Manual

6.6.3. Power Shift Pressure Valve SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → PS PRES VALVE )

Go to the ↓ Step Operation


CALIBRATIONS 01 Connect the pressure
↓ gauge.
Refer to Default Screen Then press the OK
“6.6.1.1.All Valves” key in order to go the
↓ next.
02 Press the right key or
CALIBRATIONS [Calibration]
CONTROL VALVES the left key in order to

In the calibration screen,
RELIEF VALVES increase or decrease
step number is displayed in
PS PRES VALVE the current value.
blue.
FLOW LIMIT VALVE And tune the
CHECK VALVES pressure to the
LEVER/PEDAL/ATCH Perform the operation
▼ target.
PRESS TO PERFORM written in the following table
When you finish
CALIBRATION in each step.
tuning, press the OK
key.
03 Same as step 02.
/ :MOVE CURSOR 04 End of calibration
[Calibration Screen]
↓ CALIBRATION TITLE
Note: The step of the upper
table may be omitted
↓ STEP No: STEP NAME
corresponding to the
CALIBRATIONS
CONTROL VALVES ▲
condition.
RELIEF VALVES L U
PS PRES VALVE C
FLOW LIMIT VALVE OPERATION GUIDANCE
CHECK VALVES
LEVER/PEDAL/ATCH ▼
PRESS TO PERFORM
CALIBRATION
/ :SCROLL

L: Lower limit
/ :MOVE CURSOR U: Upper limit
↓ C: Current value


[Calibration]

63
Monitoring System Operation Manual

6.6.4. Flow Limit Valve (345C/300D Phase 1) SERVICE PASSWORD REQUIRED


6.6.4.1. Flow Limit Pressure
( MAIN MENU → SERVICE → CALIBRATIONS → FLOW LIMIT VALVE → FLOW LIMIT PRES )

Go to the
FLOW LIMIT VALVE [Calibration]
CALIBRATIONS
FLOW LIMIT PRES ▲ In the calibration screen,
2PUMP FLOW LIMIT step number is displayed in
1PUMP FLOW LIMIT blue.
Refer to
“6.6.1.1.All Valves” Perform the operation
↓ ▼
written in the following table
CALIBRATIONS PRESS TO PERFORM in each step.
CONTROL VALVES ▲ CALIBRATION
RELIEF VALVES Step Operation
PS PRES VALVE 01 Connect the pressure
FLOW LIMIT VALVE gauge.
/ :MOVE CURSOR
CHECK VALVES Then press the OK
LEVER/PEDAL/ATCH ▼ ↓ key in order to go the
PRESS TO PERFORM
next.
CALIBRATION
↓ 02 Move stick to the
[Calibration] relief position.
↓ Press the OK key.
/ :MOVE CURSOR 03 Hold the stick
↓ ↓ controls to relief
Default Screen position during
↓ calibration.
CALIBRATIONS
Press the OK key.
CONTROL VALVES 04 Press the right key or

[Calibration Screen] the left key in order to
RELIEF VALVES CALIBRATION TITLE
PS PRES VALVE increase or decrease
FLOW LIMIT VALVE STEP No: STEP NAME the current value.
CHECK VALVES And tune the
LEVER/PEDAL/ATCH ▼ pressure to the
PRESS TO PERFORM L U target.
CALIBRATION C When you finish
OPERATION GUIDANCE tuning, press the OK
key.
/ :MOVE CURSOR 05 Same as step 03.
↓ 06 Same as step 04.
/ :SCROLL 07 End of calibration

L: Lower limit Note: The step of the upper
U: Upper limit table may be omitted
C: Current value corresponding to the
condition.

64
Monitoring System Operation Manual

6.6.4.2. 2 Pump Flow Limit SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → FLOW LIMIT VALVE →
2PUMP FLOW LIMIT PRES )

Go to the ↓ Step Operation


FLOW LIMIT VALVE 01 Connect the flow
↓ gauge.
Refer to Default Screen Then press the OK
“6.6.4.1.Flow Limit key in order to go the
Pressure” next.
↓ 02 Move the tool to safe
[Calibration]
FLOW LIMIT VALVE position.
In the calibration screen,
FLOW LIMIT PRES ▲ Press the OK key.
step number is displayed in
2PUMP FLOW LIMIT 03 Hold the tool controls
blue.
1PUMP FLOW LIMIT to operating position
during calibration.
Perform the operation
Press the OK key.
▼ written in the following table
04 Press the right key or
PRESS TO PERFORM in each step.
CALIBRATION the left key in order to
increase or decrease
the current value.
And tune the flow to
/ :MOVE CURSOR [Calibration Screen] the target.
CALIBRATION TITLE
↓ When you finish
tuning, press the OK
STEP No: STEP NAME
↓ key.
FLOW LIMIT VALVE 05 Same as step 03.
FLOW LIMIT PRES ▲ L U 06 Same as step 04.
2PUMP FLOW LIMIT C 07 End of calibration
1PUMP FLOW LIMIT OPERATION GUIDANCE
Note: The step of the upper

table may be omitted
PRESS TO PERFORM corresponding to the
CALIBRATION / :SCROLL condition.

L: Lower limit
U: Upper limit
/ :MOVE CURSOR
C: Current value


[Calibration]

65
Monitoring System Operation Manual

6.6.4.3. 1 Pump Flow Limit SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → FLOW LIMIT VALVE →
1PUMP FLOW LIMIT PRES )

Go to the ↓ Step Operation


FLOW LIMIT VALVE 01 Connect the flow
↓ gauge.
Refer to Default Screen Then press the OK
“6.6.4.1.Flow Limit key in order to go the
Pressure” next.
↓ 02 Move the tool to safe
FLOW LIMIT VALVE position.
FLOW LIMIT PRES ▲
[Calibration] Press the OK key.
2PUMP FLOW LIMIT In the calibration screen, 03 Hold the tool controls
1PUMP FLOW LIMIT step number is displayed in to operating position
blue. during calibration.
Press the OK key.
▼ Perform the operation 04 Press the right key or
PRESS TO PERFORM written in the following table the left key in order to
CALIBRATION in each step. increase or decrease
the current value.
And tune the flow to
/ :MOVE CURSOR the target.
↓ [Calibration Screen] When you finish
CALIBRATION TITLE tuning, press the OK
↓ key.
STEP No: STEP NAME
FLOW LIMIT VALVE 05 Same as step 03.
FLOW LIMIT PRES ▲ 06 Same as step 04.
2PUMP FLOW LIMIT L U 07 End of calibration
1PUMP FLOW LIMIT C
OPERATION GUIDANCE Note: The step of the upper

table may be omitted
PRESS TO PERFORM corresponding to the
CALIBRATION condition.
/ :SCROLL

/ :MOVE CURSOR
L: Lower limit
U: Upper limit

C: Current value

[Calibration]

66
Monitoring System Operation Manual

6.6.5. Check Valve (365C/385C) SERVICE PASSWORD REQUIRED


6.6.5.1. Boom Lowering Check Valve
( MAIN MENU → SERVICE → CALIBRATIONS → CHECK VALVE → BLCV )

Go to the
CHECK VALVES [Calibration]
CALIBRATIONS
BLCV ▲ In the calibration screen,
SLCV step number is displayed in
Refer to blue.
“6.6.1.1.All Valves”

↓ ▼
Perform the operation
CALIBRATIONS PRESS TO PERFORM written in the following table
CONTROL VALVES ▲ CALIBRATION in each step.
RELIEF VALVES
PS PRES VALVE
FLOW LIMIT VALVE
CHECK VALVES / :MOVE CURSOR
LEVER/PEDAL/ATCH ▼ ↓
PRESS TO PERFORM
CALIBRATION Step Operation
↓ 01 Raise boom and stick
[Calibration] to the max position.
↓ Then press the OK
/ :MOVE CURSOR key.
↓ ↓ 02 Wait until the oil
Default Screen temperature become
↓ a target
CALIBRATIONS 03 Set the hydraulic lock
CONTROL VALVES ▲
[Calibration Screen] lever to unlock
RELIEF VALVES CALIBRATION TITLE position.
PS PRES VALVE 04 Press the OK key in
FLOW LIMIT VALVE STEP No: STEP NAME order to go the next.
CHECK VALVES
LEVER/PEDAL/ATCH ▼
05 Hold Left lever back.
PRESS TO PERFORM 06 Release all levers
S E
CALIBRATION and pedals.
OPERATION GUIDANCE
07 Press the OK key in
order to go the next.
08 End of calibration.
/ :MOVE CURSOR
↓ Note: The step of the upper
/ :SCROLL table may be omitted
↓ corresponding to the
condition.
S: Start step number
E: End step number

67
Monitoring System Operation Manual

6.6.5.2. Stick Lowering Check Valve SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → CHECK VALVE → SLCV )

Go to the ↓ Step Operation


CALIBRATIONS 01 Raise boom and stick
↓ to the max position.
Refer to Default Screen Then press the OK
“6.6.5.1.Boom Lowering key.
Check Valve” 02 Wait until the oil
↓ temperature become
[Calibration]
CHECK VALVES a target
In the calibration screen,
BLCV ▲ 03 Set the hydraulic lock
step number is displayed in
SLCV lever to unlock
blue.
position.
04 Press the OK key in
Perform the operation
order to go the next.
▼ written in the following table
PRESS TO PERFORM in each step. 05 Hold Left lever back.
CALIBRATION 06 Release all levers
and pedals.
07 Press the OK key in
[Calibration Screen] order to go the next.
/ :MOVE CURSOR CALIBRATION TITLE
08 End of calibration.

STEP No: STEP NAME
Note: The step of the upper
↓ table may be omitted
CHECK VALVES S E corresponding to the
BLCV ▲
condition.
SLCV OPERATION GUIDANCE


PRESS TO PERFORM / :SCROLL
CALIBRATION

S: Start step number


/ :MOVE CURSOR
E: End step number


[Calibration]

68
Monitoring System Operation Manual

6.6.6. Lever/Pedal/Attachment Inputs SERVICE PASSWORD REQUIRED


6.6.6.1. All (365C/385C)
( MAIN MENU → SERVICE → CALIBRATIONS → LEVER/PEDAL/ATCH → ALL )

Go to the
LEVER/PEDAL/ATCH [Calibration]
CALIBRATIONS
ALL ▲ In the calibration screen,
LEFT LEVER F/B step number is displayed in
LEFT LEVER L/R blue.
Refer to
RIGHT LEVER F/B
“6.6.1.1.All Valves”
RIGHT LEVER L/R
↓ LEFT TRV PEDAL ▼
Perform the operation
CALIBRATIONS PRESS TO PERFORM written in the following table
CONTROL VALVES ▲ CALIBRATION in each step.
RELIEF VALVES
PS PRES VALVE
FLOW LIMIT VALVE
CHECK VALVES / :MOVE CURSOR
LEVER/PEDAL/ATCH ▼ ↓
PRESS TO PERFORM
CALIBRATION Step Operation
↓ 01 Press the OK key in
[Calibration] order to go the next.
↓ 02 Release all controls.
/ :MOVE CURSOR Then press the OK
↓ ↓ key.
Default Screen 03 Move controls to both
↓ stops.
CALIBRATIONS Then press the OK
CONTROL VALVES ▲
[Calibration Screen] key.
RELIEF VALVES CALIBRATION TITLE 04 Press the OK key in
PS PRES VALVE order to go the next.
FLOW LIMIT VALVE STEP No: STEP NAME 05 End of calibration.
CHECK VALVES
LEVER/PEDAL/ATCH ▼
PRESS TO PERFORM Note: The step of the upper
S E
CALIBRATION table may be omitted
OPERATION GUIDANCE
corresponding to the
condition.

/ :MOVE CURSOR

/ :SCROLL

S: Start step number


E: End step number

69
Monitoring System Operation Manual

6.6.6.2. Left Lever Forward/Back (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → LEVER/PEDAL/ATCH → LEFT LEVER F/B )

Go to the [Calibration] Step Operation


CALIBRATIONS In the calibration screen, 01 Press the OK key in
step number is displayed in order to go the next.
Refer to blue. 02 Release all controls.
“6.6.6.1.All” Then press the OK
↓ Perform the operation key.
LEVER/PEDAL/ATCH
written in the following table 03 Move controls to both
ALL ▲
in each step. stops.
LEFT LEVER F/B Then press the OK
LEFT LEVER L/R key.
RIGHT LEVER F/B 04 Press the OK key in
RIGHT LEVER L/R order to go the next.
LEFT TRV PEDAL ▼
05 End of calibration.
[Calibration Screen]
PRESS TO PERFORM
CALIBRATION TITLE
CALIBRATION
Note: The step of the upper
STEP No: STEP NAME
table may be omitted
corresponding to the
/ :MOVE CURSOR
S E condition.

OPERATION GUIDANCE

LEVER/PEDAL/ATCH
ALL ▲
LEFT LEVER F/B
LEFT LEVER L/R / :SCROLL
RIGHT LEVER F/B
RIGHT LEVER L/R
LEFT TRV PEDAL ▼ S: Start step number
PRESS TO PERFORM E: End step number
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
70
Monitoring System Operation Manual

6.6.6.3. Left Lever Left/Right (365C/385C) SERVICE PASSWORD REQUIRED


REQUIRED
( MAIN MENU → SERVICE → CALIBRATIONS → LEVER/PEDAL/ATCH → LEFT LEVER R/L )

Go to the [Calibration] Step Operation


CALIBRATIONS In the calibration screen, 01 Press the OK key in
step number is displayed in order to go the next.
Refer to blue. 02 Release all controls.
“6.6.6.1.All” Then press the OK
↓ Perform the operation key.
LEVER/PEDAL/ATCH
written in the following table 03 Move controls to both
ALL ▲
in each step. stops.
LEFT LEVER F/B Then press the OK
LEFT LEVER L/R key.
RIGHT LEVER F/B 04 Press the OK key in
RIGHT LEVER L/R order to go the next.
LEFT TRV PEDAL ▼
05 End of calibration.
[Calibration Screen]
PRESS TO PERFORM
CALIBRATION TITLE
CALIBRATION
Note: The step of the upper
STEP No: STEP NAME
table may be omitted
corresponding to the
/ :MOVE CURSOR
S E condition.

OPERATION GUIDANCE

LEVER/PEDAL/ATCH
ALL ▲
LEFT LEVER F/B
LEFT LEVER L/R / :SCROLL
RIGHT LEVER F/B
RIGHT LEVER L/R
LEFT TRV PEDAL ▼ S: Start step number
PRESS TO PERFORM E: End step number
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
71
Monitoring System Operation Manual

6.6.6.4. Right Lever Forward/Back (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → LEVER/PEDAL/ATCH → RIGHT LEVER F/B )

Go to the [Calibration] Step Operation


CALIBRATIONS In the calibration screen, 01 Press the OK key in
step number is displayed in order to go the next.
Refer to blue. 02 Release all controls.
“6.6.6.1.All” Then press the OK
↓ Perform the operation key.
LEVER/PEDAL/ATCH
written in the following table 03 Move controls to both
ALL ▲
in each step. stops.
LEFT LEVER F/B Then press the OK
LEFT LEVER L/R key.
RIGHT LEVER F/B 04 Press the OK key in
RIGHT LEVER L/R order to go the next.
LEFT TRV PEDAL ▼
05 End of calibration.
[Calibration Screen]
PRESS TO PERFORM
CALIBRATION TITLE
CALIBRATION
Note: The step of the upper
STEP No: STEP NAME
table may be omitted
corresponding to the
/ :MOVE CURSOR
S E condition.

OPERATION GUIDANCE

LEVER/PEDAL/ATCH
ALL ▲
LEFT LEVER F/B
LEFT LEVER L/R / :SCROLL
RIGHT LEVER F/B
RIGHT LEVER L/R
LEFT TRV PEDAL ▼ S: Start step number
PRESS TO PERFORM E: End step number
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
72
Monitoring System Operation Manual

6.6.6.5. Right Lever Left/Right (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → LEVER/PEDAL/ATCH → RIGHT LEVER R/L )

Go to the [Calibration] Step Operation


CALIBRATIONS In the calibration screen, 01 Press the OK key in
step number is displayed in order to go the next.
Refer to blue. 02 Release all controls.
“6.6.6.1.All” Then press the OK
↓ Perform the operation key.
LEVER/PEDAL/ATCH
written in the following table 03 Move controls to both
ALL ▲
in each step. stops.
LEFT LEVER F/B Then press the OK
LEFT LEVER L/R key.
RIGHT LEVER F/B 04 Press the OK key in
RIGHT LEVER L/R order to go the next.
LEFT TRV PEDAL ▼
05 End of calibration.
[Calibration Screen]
PRESS TO PERFORM
CALIBRATION TITLE
CALIBRATION
Note: The step of the upper
STEP No: STEP NAME
table may be omitted
corresponding to the
/ :MOVE CURSOR
S E condition.

OPERATION GUIDANCE

LEVER/PEDAL/ATCH
ALL ▲
LEFT LEVER F/B
LEFT LEVER L/R / :SCROLL
RIGHT LEVER F/B
RIGHT LEVER L/R
LEFT TRV PEDAL ▼ S: Start step number
PRESS TO PERFORM E: End step number
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
73
Monitoring System Operation Manual

6.6.6.6. Left Travel Pedal (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → LEVER/PEDAL/ATCH → LEFT TRV PEDAL )

Go to the [Calibration] Step Operation


CALIBRATIONS In the calibration screen, 01 Press the OK key in
step number is displayed in order to go the next.
Refer to blue. 02 Release all controls.
“6.6.6.1.All” Then press the OK
↓ Perform the operation key.
LEVER/PEDAL/ATCH
written in the following table 03 Move controls to both
ALL ▲
in each step. stops.
LEFT LEVER F/B Then press the OK
LEFT LEVER L/R key.
RIGHT LEVER F/B 04 Press the OK key in
RIGHT LEVER L/R order to go the next.
LEFT TRV PEDAL ▼
05 End of calibration.
[Calibration Screen]
PRESS TO PERFORM
CALIBRATION TITLE
CALIBRATION
Note: The step of the upper
STEP No: STEP NAME
table may be omitted
corresponding to the
/ :MOVE CURSOR
S E condition.

OPERATION GUIDANCE

LEVER/PEDAL/ATCH
ALL ▲
LEFT LEVER F/B
LEFT LEVER L/R / :SCROLL
RIGHT LEVER F/B
RIGHT LEVER L/R
LEFT TRV PEDAL ▼ S: Start step number
PRESS TO PERFORM E: End step number
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
74
Monitoring System Operation Manual

6.6.6.7. Right Travel Pedal (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → LEVER/PEDAL/ATCH → RIGHT TRV PEDAL )

Go to the [Calibration] Step Operation


CALIBRATIONS In the calibration screen, 01 Press the OK key in
step number is displayed in order to go the next.
Refer to blue. 02 Release all controls.
“6.6.6.1.All” Then press the OK
↓ Perform the operation key.
LEVER/PEDAL/ATCH
written in the following table 03 Move controls to both
ALL ▲
in each step. stops.
LEFT LEVER F/B Then press the OK
LEFT LEVER L/R key.
RIGHT LEVER F/B 04 Press the OK key in
RIGHT LEVER L/R order to go the next.
LEFT TRV PEDAL ▼
05 End of calibration.
[Calibration Screen]
PRESS TO PERFORM
CALIBRATION TITLE
CALIBRATION
Note: The step of the upper
STEP No: STEP NAME
table may be omitted
corresponding to the
/ :MOVE CURSOR
S E condition.

OPERATION GUIDANCE

LEVER/PEDAL/ATCH
LEFT LEVER F/B ▲
LEFT LEVER L/R
RIGHT LEVER F/B / :SCROLL
RIGHT LEVER L/R
LEFT TRV PEDAL
RIGHT TRV PEDAL ▼ S: Start step number
PRESS TO PERFORM E: End step number
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
75
Monitoring System Operation Manual

6.6.6.8. Modulation Left Thumbwheel SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → LEVER/PEDAL/ATCH → MOD L THUMBWHEEL )

Go to the [Calibration] Step Operation


CALIBRATIONS In the calibration screen, 01 Press the OK key in
step number is displayed in order to go the next.
Refer to blue. 02 Release all controls.
“6.6.6.1.All” Then press the OK
↓ Perform the operation key.
LEVER/PEDAL/ATCH
written in the following table 03 Move controls to both
ALL ▲
in each step. stops.
LEFT LEVER F/B Then press the OK
LEFT LEVER L/R key.
RIGHT LEVER F/B 04 Press the OK key in
RIGHT LEVER L/R order to go the next.
LEFT TRV PEDAL ▼
05 End of calibration.
[Calibration Screen]
PRESS TO PERFORM
CALIBRATION TITLE
CALIBRATION
Note: The step of the upper
STEP No: STEP NAME
table may be omitted
corresponding to the
/ :MOVE CURSOR
S E condition.

OPERATION GUIDANCE

LEVER/PEDAL/ATCH
LEFT LEVER L/R ▲
RIGHT LEVER F/B
RIGHT LEVER L/R / :SCROLL
LEFT TRV PEDAL
RIGHT TRV PEDAL
MOD L THUMBWHEEL ▼ S: Start step number
PRESS TO PERFORM E: End step number
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
76
Monitoring System Operation Manual

6.6.6.9. Modulation Right Thumbwheel SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → LEVER/PEDAL/ATCH → MOD R THUMBWHEEL )

Go to the [Calibration] Step Operation


CALIBRATIONS In the calibration screen, 01 Press the OK key in
step number is displayed in order to go the next.
Refer to blue. 02 Release all controls.
“6.6.6.1.All” Then press the OK
↓ Perform the operation key.
LEVER/PEDAL/ATCH
written in the following table 03 Move controls to both
ALL ▲
in each step. stops.
LEFT LEVER F/B Then press the OK
LEFT LEVER L/R key.
RIGHT LEVER F/B 04 Press the OK key in
RIGHT LEVER L/R order to go the next.
LEFT TRV PEDAL ▼
05 End of calibration.
[Calibration Screen]
PRESS TO PERFORM
CALIBRATION TITLE
CALIBRATION
Note: The step of the upper
STEP No: STEP NAME
table may be omitted
corresponding to the
/ :MOVE CURSOR
S E condition.

OPERATION GUIDANCE

LEVER/PEDAL/ATCH
RIGHT LEVER F/B ▲
RIGHT LEVER L/R
LEFT TRV PEDAL / :SCROLL
RIGHT TRV PEDAL
MOD L THUMBWHEEL
MOD R THUMBWHEEL ▼ S: Start step number
PRESS TO PERFORM E: End step number
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
77
Monitoring System Operation Manual

6.6.6.10. Left Atachment Pedal SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → LEVER/PEDAL/ATCH → LEFT ATCH PEDAL )

Go to the [Calibration] Step Operation


CALIBRATIONS In the calibration screen, 01 Press the OK key in
step number is displayed in order to go the next.
Refer to blue. 02 Release all controls.
“6.6.6.1.All” Then press the OK
↓ Perform the operation key.
LEVER/PEDAL/ATCH
written in the following table 03 Move controls to both
ALL ▲
in each step. stops.
LEFT LEVER F/B Then press the OK
LEFT LEVER L/R key.
RIGHT LEVER F/B 04 Press the OK key in
RIGHT LEVER L/R order to go the next.
LEFT TRV PEDAL ▼
05 End of calibration.
[Calibration Screen]
PRESS TO PERFORM
CALIBRATION TITLE
CALIBRATION
Note: The step of the upper
STEP No: STEP NAME
table may be omitted
corresponding to the
/ :MOVE CURSOR
S E condition.

OPERATION GUIDANCE

LEVER/PEDAL/ATCH
RIGHT LEVER L/R ▲
LEFT TRV PEDAL
RIGHT TRV PEDAL / :SCROLL
MOD L THUMBWHEEL
MOD R THUMBWHEEL
LEFT ATCH PEDAL ▼ S: Start step number
PRESS TO PERFORM E: End step number
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
78
Monitoring System Operation Manual

6.6.6.11. Right Attachment Pedal SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → LEVER/PEDAL/ATCH → RIGHT ATCH PEDAL)

Go to the [Calibration] Step Operation


CALIBRATIONS In the calibration screen, 01 Press the OK key in
step number is displayed in order to go the next.
Refer to blue. 02 Release all controls.
“6.6.6.1.All” Then press the OK
↓ Perform the operation key.
LEVER/PEDAL/ATCH
written in the following table 03 Move controls to both
ALL ▲
in each step. stops.
LEFT LEVER F/B Then press the OK
LEFT LEVER L/R key.
RIGHT LEVER F/B 04 Press the OK key in
RIGHT LEVER L/R order to go the next.
LEFT TRV PEDAL ▼
05 End of calibration.
[Calibration Screen]
PRESS TO PERFORM
CALIBRATION TITLE
CALIBRATION
Note: The step of the upper
STEP No: STEP NAME
table may be omitted
corresponding to the
/ :MOVE CURSOR
S E condition.

OPERATION GUIDANCE

LEVER/PEDAL/ATCH
LEFT TRV PEDAL ▲
RIGHT TRV PEDAL
MOD L THUMBWHEEL / :SCROLL
MOD R THUMBWHEEL
LEFT ATCH PEDAL
RIGHT ATCH PEDAL ▼ S: Start step number
PRESS TO PERFORM E: End step number
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
79
Monitoring System Operation Manual

6.6.7. Engine Speed SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CALIBRATIONS → ENGINE SPEED )

Go to the
CALIBRATIONS [Calibration] Step Operation
In the calibration screen, 01 Press the OK key in
Refer to step number is displayed in order to go the next.
“6.6.1.1.All Valves” blue. 02 Press the OK key.
↓ 03 -
CALIBRATIONS Perform the operation 04 -
CONTROL VALVES ▲ written in the following table 05 -
RELIEF VALVES in each step. 06 -
PS PRES VALVE 07 -
FLOW LIMIT VALVE
08 -
CHECK VALVES
[Calibration Screen] 09 -
LEVER/PEDAL/ATCH ▼
PRESS TO PERFORM
CALIBRATION TITLE 10 -
CALIBRATION 11 End of calibration.
STEP No: STEP NAME

Note: The step of the upper


S E table may be omitted
/ :MOVE CURSOR
corresponding to the
↓ OPERATION GUIDANCE condition.


CALIBRATIONS
RELIEF VALVES ▲
PS PRES VALVE / :SCROLL
FLOW LIMIT VALVE
CHECK VALVES
LEVER/PEDAL/ATCH S: Start step number
ENGINE SPEED ▼ E: End step number
PRESS TO PERFORM
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
80
Monitoring System Operation Manual

6.6.8. Fan Speed SERVICE


SERVICE PASSWORD REQUIRED
( MAIN MENU → SERVICE → CALIBRATIONS → FAN SPEED )

Go to the
CALIBRATIONS [Calibration] Step Operation
In the calibration screen, 01 Connect the speed
Refer to step number is displayed in sensor to the fan.
“6.6.1.1.All Valves” blue. Then press the OK
↓ key in order to go the
CALIBRATIONS Perform the operation next.
CONTROL VALVES ▲ written in the following table 02 Press the right key or
RELIEF VALVES in each step. the left key in order to
PS PRES VALVE increase or decrease
FLOW LIMIT VALVE the current value.
CHECK VALVES And tune the fan
LEVER/PEDAL/ATCH ▼
[Calibration Screen] speed to the target.
PRESS TO PERFORM
CALIBRATION TITLE When you finish
CALIBRATION
tuning, press the OK
STEP No: STEP NAME key.
03 Same as step 02.
/ :MOVE CURSOR 04 End of calibration
L U
↓ C
OPERATION GUIDANCE Note: The step of the upper
↓ table may be omitted
CALIBRATIONS corresponding to the
PS PRES VALVE ▲ condition.
FLOW LIMIT VALVE
CHECK VALVES / :SCROLL
LEVER/PEDAL/ATCH
ENGINE SPEED L: Lower limit
FAN SPEED ▼ U: Upper limit
PRESS TO PERFORM C: Current value
CALIBRATION

/ :MOVE CURSOR


[Calibration]


Default Screen
81
Monitoring System Operation Manual

6.7. Device Test (345C/300D Phase 1) SERVICE PASSWORD REQUIRED


6.7.1. Desired Engine Speed
( MAIN MENU → SERVICE → DEVICE TEST → DESIRED ENG SPEED )

Go to the
DEVICE TEST When the sweep test is
SERVICE
DESIRED ENG SPEED ▲ activated, press the OK key
POWER SHIFT PRES in order to stop the sweep
FLOW LIMIT PRES test.
Refer to
A1 VALVE EXTEND
“6.Service”
A1 VALVE RETRACT
↓ A3 VALVE EXTEND ▼ [Device Test Screen]
PRESS TO PERFORM DESIRED ENG SPEED
SERVICE
DEVICE TEST ▲
MAINTENANCE ▲
02: ACTIVATING
PASSWORD CHANGE
ENGINE SPEED
DIAGNOSTIC
----[rpm]
ECM INFO
STATUS / :MOVE CURSOR

CALIBRATIONS ▼ ↓
PRESS TO CHANGE
MAINTE INFO

[Device Test] :BACK
↓ :SWEEP START
/ :-/+
/ :MOVE CURSOR
↓ ↓
Default Screen

SERVICE
PASSWORD CHANGE ▲ [Device Test]
DIAGNOSTIC When "01:STAND BY" is
ECM INFO
displayed on the screen,
STATUS
press the OK key in order to
CALIBRATIONS
DEVICE TEST ▼
start device test.
PRESS TO PERFORM
DEVICE TEST In this screen, the following
item can be tested.

/ :MOVE CURSOR Engine Speed


↓ Press the right key or the
left key in order to increase
↓ or decrease engine speeed.

Press the OK key in order to


start the sweep test.

82
Monitoring System Operation Manual

6.7.2. Power Shift Pressure SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → DEVICE TEST → POWER SHIFT PRES )

Go to the [Device Test] [Device Test Screen]


↓ POWER SHIFT PRES
DEVICE TEST

02: ACTIVATING
Refer to ↓
“6.7.1.Desired Engine ENGINE SPEED
Speed”
Default Screen ----[rpm]
POWER SHIFT PRES
↓ ----[Kpa] ▼
DEVICE TEST
[Device Test]
DESIRED ENG SPEED ▲
When "01:STAND BY" is
POWER SHIFT PRES :BACK
FLOW LIMIT PRES displayed on the screen, :SWEEP START
A1 VALVE EXTEND press the OK key in order to / :-/+
A1 VALVE RETRACT start device test. / :MOVE CURSOR
A3 VALVE EXTEND ▼
PRESS TO PERFORM In this screen, the following
DEVICE TEST item can be tested.

Press the up key or the


down key in order to
/ :MOVE CURSOR
highlight the desired item.

Engine Speed
↓ Press the right key or the
DEVICE TEST left key in order to increase
DESIRED ENG SPEED ▲ or decrease engine speeed.
POWER SHIFT PRES
FLOW LIMIT PRES
A1 VALVE EXTEND
A1 VALVE RETRACT
Power Shift Pressure
A3 VALVE EXTEND ▼ Press the right key or the
PRESS TO PERFORM left key in order to increase
DEVICE TEST or decrease power shift
pressure.

Press the OK key in order to


/ :MOVE CURSOR start the sweep test.

When the sweep test is
↓ activated, press the OK key
in order to stop the sweep
test.

83
Monitoring System Operation Manual

6.7.3. Flow Limit Valve Pressure SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → DEVICE TEST → FLOW LIMIT PRES )

Go to the [Device Test]


DEVICE TEST ↓ [Device Test Screen]
FLOW LIMIT PRES
Refer to ↓ ▲
“6.7.1.Desired Engine 02: ACTIVATING
Speed”
Default Screen ENGINE SPEED
----[rpm]
↓ FLOW LIMIT PRES
DEVICE TEST
[Device Test] ----[Kpa] ▼
DESIRED ENG SPEED ▲
When "01:STAND BY" is
POWER SHIFT PRES
FLOW LIMIT PRES displayed on the screen,
:BACK
A1 VALVE EXTEND press the OK key in order to
:SWEEP START
A1 VALVE RETRACT start device test. / :-/+
A3 VALVE EXTEND ▼ / :MOVE CURSOR
PRESS TO PERFORM In this screen, the following
DEVICE TEST item can be tested.

Press the up key or the


down key in order to
/ :MOVE CURSOR
highlight the desired item.

Engine Speed
↓ Press the right key or the
DEVICE TEST left key in order to increase
DESIRED ENG SPEED ▲ or decrease engine speeed.
POWER SHIFT PRES
FLOW LIMIT PRES
A1 VALVE EXTEND
A1 VALVE RETRACT
Flow Limit Pressure
A3 VALVE EXTEND ▼ Press the right key or the
PRESS TO PERFORM left key in order to increase
DEVICE TEST or decrease flow limit
pressure.

Press the OK key in order to


/ :MOVE CURSOR start the sweep test.

When the sweep test is
↓ activated, press the OK key
in order to stop the sweep
test.

84
Monitoring System Operation Manual

6.7.4. Attachment Valve #1 Extend SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → DEVICE TEST → A1 VALVE EXTEND )

Go to the [Device Test] [Device Test Screen]


↓ A1 EXTEND VALVE
DEVICE TEST

02: ACTIVATING
Refer to ↓
“6.7.1.Desired Engine ENGINE SPEED
Speed”
Default Screen ----[rpm]
A1 VALVE EXTEND
↓ ----[Kpa] ▼
DEVICE TEST KEEP THE LEVER/PEDAL
[Device Test]
DESIRED ENG SPEED ▲ OF A TOOL OPERATED
When "01:STAND BY" is
POWER SHIFT PRES
FLOW LIMIT PRES displayed on the screen, :BACK
A1 VALVE EXTEND press the OK key in order to :SWEEP START
A1 VALVE RETRACT start device test. / :-/+
A3 VALVE EXTEND ▼
PRESS TO PERFORM In this screen, the following
DEVICE TEST item can be tested.

/ :MOVE CURSOR


DEVICE TEST
DESIRED ENG SPEED ▲
POWER SHIFT PRES Attachment Valve #1
FLOW LIMIT PRES
Extend Pressure
A1 VALVE EXTEND
A1 VALVE RETRACT
Command
A3 VALVE EXTEND ▼ Press the right key or the
PRESS TO PERFORM left key in order to increase
DEVICE TEST or decrease attachment
valve #1 extend pressure
command.

/ :MOVE CURSOR Press the OK key in order to


↓ start the sweep test.

↓ When the sweep test is


activated, press the OK key
in order to stop the sweep
test.

85
Monitoring System Operation Manual

6.7.5. Attachment Valve #1 Retract SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → DEVICE TEST → A1 VALVE RETRACT)

Go to the [Device Test] [Device Test Screen]


↓ A1 RETRACT VALVE
DEVICE TEST

02: ACTIVATING
Refer to ↓
“6.7.1.Desired Engine ENGINE SPEED
Speed”
Default Screen ----[rpm]
A1 VALVE RETRACT
↓ ----[Kpa] ▼
DEVICE TEST KEEP THE LEVER/PEDAL
[Device Test]
DESIRED ENG SPEED ▲ OF A TOOL OPERATED
When "01:STAND BY" is
POWER SHIFT PRES
FLOW LIMIT PRES displayed on the screen, :BACK
A1 VALVE EXTEND press the OK key in order to :SWEEP START
A1 VALVE RETRACT start device test. / :-/+
A3 VALVE EXTEND ▼
PRESS TO PERFORM In this screen, the following
DEVICE TEST item can be tested.

/ :MOVE CURSOR


DEVICE TEST
DESIRED ENG SPEED ▲
POWER SHIFT PRES Attachment Valve #1
FLOW LIMIT PRES
Retract Pressure
A1 VALVE EXTEND
A1 VALVE RETRACT
Command
A3 VALVE EXTEND ▼ Press the right key or the
PRESS TO PERFORM left key in order to increase
DEVICE TEST or decrease attachment
valve #1 retract pressure
command.

/ :MOVE CURSOR Press the OK key in order to


↓ start the sweep test.

↓ When the sweep test is


activated, press the OK key
in order to stop the sweep
test.

86
Monitoring System Operation Manual

6.7.6. Attachment Valve #3 Extend SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → DEVICE TEST → A3 VALVE EXTEND)

Go to the [Device Test] [Device Test Screen]


↓ A3 EXTEND VALVE
DEVICE TEST

02: ACTIVATING
Refer to ↓
“6.7.1.Desired Engine ENGINE SPEED
Speed”
Default Screen ----[rpm]
A3 VALVE EXTEND
↓ ----[Kpa] ▼
DEVICE TEST KEEP THE LEVER/PEDAL
[Device Test]
DESIRED ENG SPEED ▲ OF A TOOL OPERATED
When "01:STAND BY" is
POWER SHIFT PRES
FLOW LIMIT PRES displayed on the screen, :BACK
A1 VALVE EXTEND press the OK key in order to :SWEEP START
A1 VALVE RETRACT start device test. / :-/+
A3 VALVE EXTEND ▼
PRESS TO PERFORM In this screen, the following
DEVICE TEST item can be tested.

/ :MOVE CURSOR


DEVICE TEST
DESIRED ENG SPEED ▲
POWER SHIFT PRES Attachment Valve #3
FLOW LIMIT PRES
Extend Pressure
A1 VALVE EXTEND
A1 VALVE RETRACT
Command
A3 VALVE EXTEND ▼ Press the right key or the
PRESS TO PERFORM left key in order to increase
DEVICE TEST or decrease attachment
valve #3 extend pressure
command.

/ :MOVE CURSOR Press the OK key in order to


↓ start the sweep test.

↓ When the sweep test is


activated, press the OK key
in order to stop the sweep
test.

87
Monitoring System Operation Manual

6.7.7. Attachment Valve #3 Retract SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → DEVICE TEST → A3 VALVE RETRACT)

Go to the [Device Test] [Device Test Screen]


↓ A3 RETRACT VALVE
DEVICE TEST

02: ACTIVATING
Refer to ↓
“6.7.1.Desired Engine ENGINE SPEED
Speed”
Default Screen ----[rpm]
A3 VALVE RETRACT
↓ ----[Kpa] ▼
DEVICE TEST KEEP THE LEVER/PEDAL
[Device Test]
DESIRED ENG SPEED ▲ OF A TOOL OPERATED
When "01:STAND BY" is
POWER SHIFT PRES
FLOW LIMIT PRES displayed on the screen, :BACK
A1 VALVE EXTEND press the OK key in order to :SWEEP START
A1 VALVE RETRACT start device test. / :-/+
A3 VALVE EXTEND ▼
PRESS TO PERFORM In this screen, the following
DEVICE TEST item can be tested.

/ :MOVE CURSOR


DEVICE TEST
POWER SHIFT PRES ▲
FLOW LIMIT PRES Attachment Valve #3
A1 VALVE EXTEND
Retract Pressure
A1 VALVE RETRACT
A3 VALVE EXTEND
Command
A3 VALVE RETRACT ▼ Press the right key or the
PRESS TO PERFORM left key in order to increase
DEVICE TEST or decrease attachment
valve #3 retract pressure
command.

/ :MOVE CURSOR Press the OK key in order to


↓ start the sweep test.

↓ When the sweep test is


activated, press the OK key
in order to stop the sweep
test.

88
Monitoring System Operation Manual

6.7.8. A1 Relief Valve SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → DEVICE TEST → A1 RLF VALVE )

Go to the [Device Test] [Device Test Screen]


↓ A1 RLF VALVE
DEVICE TEST

02: ACTIVATING
Refer to ↓
“6.7.1.Desired Engine ENGINE SPEED
Speed”
Default Screen ----[rpm]
A1 RLF VALVE
↓ ----[Kpa] ▼
DEVICE TEST
[Device Test]
DESIRED ENG SPEED ▲
When "01:STAND BY" is
POWER SHIFT PRES
FLOW LIMIT PRES displayed on the screen, :BACK
A1 VALVE EXTEND press the OK key in order to :SWEEP START
A1 VALVE RETRACT start device test. / :-/+
A3 VALVE EXTEND ▼
PRESS TO PERFORM In this screen, the following
DEVICE TEST item can be tested.

/ :MOVE CURSOR


DEVICE TEST
FLOW LIMIT PRES ▲
A1 VALVE EXTEND Attachment Variable
A1 VALVE RETRACT
Relief Valve #1 Pressure
A3 VALVE EXTEND
A3 VALVE RETRACT
Command
A1 RLF VALVE ▼ Press the right key or the
PRESS TO PERFORM left key in order to increase
DEVICE TEST or decrease attachment
variable relief valve #1
pressure command.

/ :MOVE CURSOR Press the OK key in order to


↓ start the sweep test.

↓ When the sweep test is


activated, press the OK key
in order to stop the sweep
test.

89
Monitoring System Operation Manual

6.7.9. A2 Relief Valve SERVICE PASSWORD REQUIRED


REQUIRED
( MAIN MENU → SERVICE → DEVICE TEST → A2 RLF VALVE )

Go to the [Device Test] [Device Test Screen]


↓ A2 RLF VALVE
DEVICE TEST

02: ACTIVATING
Refer to ↓
“6.7.1.Desired Engine ENGINE SPEED
Speed”
Default Screen ----[rpm]
A2 RLF VALVE
↓ ----[Kpa] ▼
DEVICE TEST
[Device Test]
DESIRED ENG SPEED ▲
When "01:STAND BY" is
POWER SHIFT PRES
FLOW LIMIT PRES displayed on the screen, :BACK
A1 VALVE EXTEND press the OK key in order to :SWEEP START
A1 VALVE RETRACT start device test. / :-/+
A3 VALVE EXTEND ▼
PRESS TO PERFORM In this screen, the following
DEVICE TEST item can be tested.

/ :MOVE CURSOR


DEVICE TEST
A1 VALVE EXTEND ▲
A1 VALVE RETRACT Attachment Variable
A3 VALVE EXTEND
Relief Valve #2 Pressure
A3 VALVE RETRACT
A1 RLF VALVE
Command
A2 RLF VALVE ▼ Press the right key or the
PRESS TO PERFORM left key in order to increase
DEVICE TEST or decrease attachment
variable relief valve #2
pressure command.

/ :MOVE CURSOR Press the OK key in order to


↓ start the sweep test.

↓ When the sweep test is


activated, press the OK key
in order to stop the sweep
test.

90
Monitoring System Operation Manual

6.7.10. 2 Pump Flow Limit SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → DEVICE TEST → 2PUMP FLOW LIMIT )

Go to the [Device Test] [Device Test Screen]


↓ 2PUMP FLOW LIMIT
DEVICE TEST

02: ACTIVATING
Refer to ↓
“6.7.1.Desired Engine NOMINAL PRESSURE
Speed”
Default Screen ----[KPa]
2PUMP FLOW LIMIT
↓ ----[L/m] ▼
DEVICE TEST KEEP THE LEVER/PEDAL
[Device Test]
DESIRED ENG SPEED ▲ OF A TOOL OPERATED
When "01:STAND BY" is
POWER SHIFT PRES
FLOW LIMIT PRES displayed on the screen, :BACK
A1 VALVE EXTEND press the OK key in order to / :-/+
A1 VALVE RETRACT start device test. / :MOVE CURSOR
A3 VALVE EXTEND ▼
PRESS TO PERFORM In this screen, the following
DEVICE TEST item can be tested.

Press the up key or the


down key in order to
/ :MOVE CURSOR
highlight the desired item.

Nominal Pressure
↓ Press the right key or the
DEVICE TEST left key in order to increase
A1 VALVE RETRACT ▲ or decrease pressure.
A3 VALVE EXTEND
A3 VALVE RETRACT
A1 RLF VALVE
A2 RLF VALVE
2 Pump Flow Limit
2PUMP FLOW LIMIT ▼ Press the right key or the
PRESS TO PERFORM left key in order to increase
DEVICE TEST or decrease 2 pump flow
limit command.

/ :MOVE CURSOR

91
Monitoring System Operation Manual

6.7.11. 1 Pump Flow Limit SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → DEVICE TEST → 1PUMP FLOW LIMIT )

Go to the [Device Test] [Device Test Screen]


↓ 1PUMP FLOW LIMIT
DEVICE TEST

02: ACTIVATING
Refer to ↓
“6.7.1.Desired Engine NOMINAL PRESSURE
Speed”
Default Screen ----[KPa]
1PUMP FLOW LIMIT
↓ ----[L/min] ▼
DEVICE TEST KEEP THE LEVER/PEDAL
[Device Test]
DESIRED ENG SPEED ▲ OF A TOOL OPERATED
When "01:STAND BY" is
POWER SHIFT PRES
FLOW LIMIT PRES displayed on the screen, :BACK
A1 VALVE EXTEND press the OK key in order to / :-/+
A1 VALVE RETRACT start device test. / :MOVE CURSOR
A3 VALVE EXTEND ▼
PRESS TO PERFORM In this screen, the following
DEVICE TEST item can be tested.

Press the up key or the


down key in order to
/ :MOVE CURSOR
highlight the desired item.

Nominal Pressure
↓ Press the right key or the
DEVICE TEST left key in order to increase
A3 VALVE EXTEND ▲ or decrease pressure.
A3 VALVE RETRACT
A1 RLF VALVE
A2 RLF VALVE
2PUMP FLOW LIMIT
1 Pump Flow Limit
1PUMP FLOW LIMIT ▼ Press the right key or the
PRESS TO PERFORM left key in order to increase
DEVICE TEST or decrease 1 pump flow
limit command.

/ :MOVE CURSOR

92
Monitoring System Operation Manual

6.8. Override SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → OVERRIDE )

Go to the [After Moving Cursor]


OVERRIDE OVERRIDE
SERVICE
TRV SPEED SHIFT ▲ TRV SPEED SHIFT ▲
OFF OFF
Refer to
“6.Service” SWING BREAK SOL SWING BREAK SOL
OFF OFF
↓ TRV ALARM SOL TRV ALARM SOL
SERVICE OFF ▼ OFF ▼
MAINTENANCE ▲ PRESS TO CHANGE PRESS TO START
PASSWORD CHANGE DATA TO OVERRIDE
DIAGNOSTIC
ECM INFO
STATUS :OVERRIDE OFF
CALIBRATIONS ▼ / :MOVE CURSOR / :CHANGE VALUE
PRESS TO CHANGE ↓
MAINTE INFO After moving cursor to
[Override]
↓ parameter area, press the
up key or the down key in
order to change a value.
/ :MOVE CURSOR ↓
↓ Default Screen
After changing a value,
press the OK key in order to
↓ start to override.
SERVICE
DIAGNOSTIC ▲
[Override]
ECM INFO
[Override On]
Press the up key or the OVERRIDE
STATUS
CALIBRATIONS
down key in order to TRV SPEED SHIFT ▲

DEVICE TEST highlight the item you want OFF


OVERRIDE ▼ to override. SWING BREAK SOL
OFF
PRESS TO PERFORM
TRV ALARM SOL
OVERRIDE
OFF ▼
PRESS TO CHANGE
DATA
/ :MOVE CURSOR
↓ :OVERRIDE OFF
/ :MOVE CURSOR

If you want to stop to
override, highlight the
desired item and press the
left key.

93
Monitoring System Operation Manual

Override List (1/1)

365C/385C
Display 345C Description
TRAVEL SPEED SHIFT x x Travel Speed Solenoid Override
SWING BREAK SOL x x Swing Brake Solenoid Override
TRV ALARM x x Travel Alarm Override
SYSTEM PRES UP x Front System High Pressure Solenoid Override
NEUTRAL FLOW BYPASS x Neutral Flow Bypass Solenoid Override
ANTI DRIFT BOOM x Boom Anti Drift Solenoid Override
ANTI DRIFT STICK x Stick Anti Drift Solenoid Override
AUTO LUB RELAY x Auto Lube Solenoid Override
REVERSE FAN SOL x x Auto Reverse Fan Solenoid Override
1P/2P CHANGE SOL x Auxiliary Circuit Flow Combining Solenoid Override
FAULT ALARM x Action Alarm Override
1/2WAY CHANGE SOL x One Way / Two Way Valve Solenoid Override
RELIEF CHK SOL #1 x Relief Valve #1 Check Valve Solenoid Override
RELIEF CHK SOL #2 x Relief Valve #2 Check Valve Solenoid Override
DESIRED ENG SPEED x x Desired Engine Speed
BOOM EXTEND x Boom Cylinder Rod Extend Solenoid Current Override
BOOM RETRACT x Boom Cylinder Rod Retract Solenoid Current Override
STICK EXTEND x Stick Cylinder Rod Extend Solenoid Current Override
STICK RETRACT x Stick Cylinder Rod Retract Solenoid Current Override
BUCKET EXTEND x Bucket Cylinder Rod Extend Solenoid Current Override
BUCKET RETRACT x Bucket Cylinder Rod Retract Solenoid Current Override
SWING LEFT x Swing Left Solenoid Current Override
SWING RIGHT x Swing Right Solenoid Current Override
TRV LEFT FW x Left Travel Forward Solenoid Current Override
TRV LEFT BW x Left Travel Backward Solenoid Current Override
TRV RIGHT FW x Right Travel Forward Solenoid Current Override
TRV RIGHT BW x Right Travel Backward Solenoid Current Override
BM LOWERING CHECK x Boom Lowering Check/Modulation Valve Solenoid Current Override
ST LOWERING CHECK x Stick Lowering Check/Modulation Valve Solenoid Current Override
ATCH EXTEND x Attachment Extend/CW Solenoid Current Override
ATCH RETRACT x Attachment Retract/CCW Solenoid Current Override
MID CURCIT EXTEND x Medium Pressure Circuit#1-A Solenoid Current Override
MID CURCIT RETRACT x Medium Pressure Circuit#1-B Solenoid Current Override
POWER SHIFT PRES x Implement Pump Power Shift Pressure Solenoid Current Override
SWING PUMP SWASH x Swash Plate Solenoid Current Override
FAN MOTOR SPEED x x Fan Motor Speed

94
Monitoring System Operation Manual

6.9. Configurations SERVICE PASSWORD REQUIRED


6.9.1. Attachment Parts Installation
( MAIN MENU → SERVICE → CONFIGURATIONS → ATCH PARTS INST )

Go to the
CONFIGURATIONS [Configuration]
SERVICE
ATCH PARTS INST ▲ Press the up key or the
TOOL INSTALLATION down key in order to
CONTROL INST highlight the item you want
Refer to
FRONT LINKAGE
“6.Service” to change setting.
PRODUCT ID
↓ PARAMETER SETTING ▼
SERVICE PRESS TO CONFIGURE And press the OK key in
MAINTENANCE ▲ ATTACHMENT PARTS order to move a highlight to
PASSWORD CHANGE INSTALLATION data value.
DIAGNOSTIC (Ref. next figure)
ECM INFO
STATUS / :MOVE CURSOR ATCH PARTS INST
CALIBRATIONS ▼ ↓ HYD OIL TYPE ▲
PRESS TO CHANGE MINERAL
MAINTE INFO TRAVEL ALARM

NOT CONFIGURED
ATCH PARTS INST
WATER SEPARATOR SW
HYD OIL TYPE ▲
NOT CONFIGURED ▼
MINERAL
/ :MOVE CURSOR PRESS TO SET
TRAVEL ALARM
↓ NOT CONFIGURED
DATA
WATER SEPARATOR SW
↓ NOT CONFIGURED ▼
SERVICE PRESS TO CHANGE
/ :CHANGE VALUE
ECM INFO ▲ DATA
STATUS
CALIBRATIONS Then press the up key and
DEVICE TEST the down key in order to
OVERRIDE / :MOVE CURSOR change the value.
CONFIGURATIONS ▼ ↓
PRESS TO CONFIGURE [Configuration] After changing to the value
MACHINE ECM ↓ you want, press the OK key
in order to set the value into
↓ a machine controller.
/ :MOVE CURSOR Default Screen

95
Monitoring System Operation Manual

6.9.2. Tool Installation SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → TOOL INSTALLATION )

Go to the
TOOL INSTALLATION [Configuration]
CONFIGURATIONS
MACHINE APPLICATION ▲ Press the up key or the
SPECIAL APPLI down key in order to
ATCH ECM INSTAL highlight the item you want
Refer to
NOT CONFIGURED
“6.9.1.Attachment Parts to change setting.
Installation” FLOW LIMIT VALVE
NOT CONFIGURED ▼
↓ PRESS TO CHANGE And press the OK key in
CONFIGURATIONS DATA order to move a highlight to
ATCH PARTS INST ▲ data value.
TOOL INSTALLATION (Ref. next figure)
CONTROL INST
FRONT LINKAGE / :MOVE CURSOR TOOL INSTALLATION
PRODUCT ID ↓ MACHINE APPLICATION ▲
PARAMETER SETTING ▼ [Configuration] SPECIAL APPLI
PRESS TO CONFIGURE ATCH ECM INSTAL

ATACHMENT PARTS NOT CONFIGURED
INSTALLATION FLOW LIMIT VALVE
↓ NOT CONFIGURED ▼
Default Screen PRESS TO SET
/ :MOVE CURSOR DATA


/ :CHANGE VALUE
CONFIGURATIONS
ATCH PARTS INST ▲
TOOL INSTALLATION Then press the up key and
CONTROL INST the down key in order to
FRONT LINKAGE change the value.
PRODUCT ID
PARAMETER SETTING ▼ After changing to the value
PRESS TO CONFIGURE you want, press the OK key
TOOL INSTALLATION in order to set the value into
a machine controller.

/ :MOVE CURSOR

96
Monitoring System Operation Manual

6.9.3. Controls Installation SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → CONTROL INST )

Go to the
CONTROL INST [Configuration]
CONFIGURATIONS
LEFT JOYSTICK SW #1 ▲ Press the up key or the
NOT CONFIGURED down key in order to
LEFT JOYSTICK SW #2 highlight the item you want
Refer to
NOT CONFIGURED
“6.9.1.Attachment Parts to change setting.
Installation” RIGHT JOYSTICK SW #1
NOT CONFIGURED ▼
↓ PRESS TO CHANGE And press the OK key in
CONFIGURATIONS DATA order to move a highlight to
ATCH PARTS INST ▲ data value.
TOOL INSTALLATION (Ref. next figure)
CONTROL INST
FRONT LINKAGE / :MOVE CURSOR CONTROL INST
PRODUCT ID ↓ LEFT JOYSTICK SW #1 ▲
PARAMETER SETTING ▼ [Configuration] NOT CONFIGURED
PRESS TO CONFIGURE LEFT JOYSTICK SW #2

ATACHMENT PARTS NOT CONFIGURED
INSTALLATION RIGHT JOYSTICK SW #1
↓ NOT CONFIGURED ▼
Default Screen PRESS TO SET
/ :MOVE CURSOR DATA


/ :CHANGE VALUE
CONFIGURATIONS
ATCH PARTS INST ▲
TOOL INSTALLATION Then press the up key and
CONTROL INST the down key in order to
FRONT LINKAGE change the value.
PRODUCT ID
PARAMETER SETTING ▼ After changing to the value
PRESS TO CONFIGURE you want, press the OK key
CONTROLS INSTALLATION in order to set the value into
a machine controller.

/ :MOVE CURSOR

97
Monitoring System Operation Manual

6.9.4. Front Linkage Configuration (365C / 385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → FRONT LINKAGE )

Go to the
CONFIGURATIONS FRONT LINKAGE [Configuration]
BUCKET TYPE ▲ Press the up key or the
Refer to EXCAVATION down key in order to
“6.9.1.Attachment Parts highlight the item you want
Installation” to change setting.
↓ ▼
CONFIGURATIONS PRESS TO CHANGE And press the OK key in
ATCH PARTS INST ▲ DATA order to move a highlight to
TOOL INSTALLATION data value.
CONTROL INST (Ref. next figure)
FRONT LINKAGE
PRODUCT ID / :MOVE CURSOR FRONT LINKAGE
PARAMETER SETTING ▼
↓ BUCKET TYPE ▲
PRESS TO CONFIGURE
[Configuration] EXCAVATION
ATACHMENT PARTS
INSTALLATION ↓

↓ ▼
/ :MOVE CURSOR Default Screen PRESS TO SET
↓ DATA


CONFIGURATIONS
ATCH PARTS INST ▲
/ :CHANGE VALUE
TOOL INSTALLATION
CONTROL INST Then press the up key and
FRONT LINKAGE the down key in order to
PRODUCT ID change the value.
PARAMETER SETTING ▼
PRESS TO CONFIGURE After changing to the value
FRONT LINKAGE
you want, press the OK key
in order to set the value into
a machine controller.
/ :MOVE CURSOR

98
Monitoring System Operation Manual

6.9.5. Product ID SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → PRODUCT ID )

Go to the
PRODUCT ID [Configuration]
CONFIGURATIONS
PRODUCT ID ▲ Press the OK key in order to
ZZZ01234 move a highlight to data
Refer to value.
“6.9.1.Attachment Parts (Ref. next figure)
Installation”

↓ PRESS TO CHANGE PRODUCT ID
CONFIGURATIONS DATA PRODUCT ID ▲

ATCH PARTS INST ▲


ZZZ01234
TOOL INSTALLATION
CONTROL INST
FRONT LINKAGE / :MOVE CURSOR

PRODUCT ID ↓
PARAMETER SETTING PRESS TO SET
▼ [Configuration] DATA
PRESS TO CONFIGURE

ATACHMENT PARTS
INSTALLATION
↓ / :MOVE CURSOR
/ :CHANGE VALUE
Default Screen
/ :MOVE CURSOR
↓ Then press the up key and
the down key in order to
↓ change the character.
CONFIGURATIONS
ATCH PARTS INST ▲
Press the right key or the
TOOL INSTALLATION left key in order to move the
CONTROL INST red cursor to the side
FRONT LINKAGE characters.
PRODUCT ID
PARAMETER SETTING ▼ After changing to the value
PRESS TO CONFIGURE you want, press the OK key
PRODUCT ID in order to set the value into
a machine controller.

/ :MOVE CURSOR

99
Monitoring System Operation Manual

6.9.6. Parameter Setting SERVICE PASSWORD REQUIRED


6.9.6.1. Engine Speed
( MAIN MENU → SERVICE → CONFIGURATIONS → PARAMETER SETTING → ENGINE SPEED )

Go to the
PARAMETER SETTING [Configuration]
CONFIGURATIONS
ENGINE SPEED ▲ Press the up key or the
DIAL TORQUE down key in order to
AEC highlight the item you want
Refer to
TRV SPEED SHIFT
“6.9.1.Attachment Parts to change setting.
Installation” OVER LOAD WARNING
ONE TOUCH LOW IDLE ▼
↓ PRESS TO SET And press the OK key in
CONFIGURATIONS ENGINE SPEED order to move a highlight to
ATCH PARTS INST ▲ data value.
TOOL INSTALLATION (Ref. next figure)
CONTROL INST
FRONT LINKAGE / :MOVE CURSOR ENGINE SPEED
PRODUCT ID ↓ DIAL 1 SPEED ▲
PARAMETER SETTING ▼ 900.0[RPM]
PRESS TO CONFIGURE DIAL 2 SPEED
ATACHMENT PARTS

1020.0[RPM]
INSTALLATION ENGINE SPEED
DIAL 3 SPEED
DIAL 1 SPEED ▲
1160.0[RPM] ▼
900.0[RPM]
PRESS TO SET
/ :MOVE CURSOR DIAL 2 SPEED
DATA
1020.0[RPM]

DIAL 3 SPEED
1160.0[RPM] ▼
↓ PRESS TO CHANGE
/ :CHANGE VALUE
CONFIGURATIONS DATA
ATCH PARTS INST ▲
TOOL INSTALLATION Then press the up key and
CONTROL INST the down key in order to
FRONT LINKAGE / :MOVE CURSOR change the value.
PRODUCT ID ↓
PARAMETER SETTING ▼ [Configuration] After changing to the value
PRESS TO SET
↓ you want, press the OK key
PARAMETERS in order to set the value into
↓ a machine controller.
Default Screen
/ :MOVE CURSOR

100
Monitoring System Operation Manual

6.9.6.2. Dial Torque SERVICE


SERVICE PASSWORD REQUIRED
( MAIN MENU → SERVICE → CONFIGURATIONS → PARAMETER SETTING → DIAL TORQUE )

Go to the
DIAL TORQUE [Configuration]
PARAMETER SETTING
DIAL 1 TORQUE ▲ Press the up key or the
34[%] down key in order to
DIAL 2 TORQUE highlight the item you want
Refer to
44[%]
“6.9.5.1.Parameter to change setting.
Setting” DIAL 3 TORQUE
54[%] ▼
↓ PRESS TO CHANGE And press the OK key in
PARAMETER SETTING DATA order to move a highlight to
ENGINE SPEED ▲ data value.
DIAL TORQUE (Ref. next figure)
AEC
TRV SPEED SHIFT / :MOVE CURSOR DIAL TORQUE
OVER LOAD WARNING ↓ DIAL 1 TORQUE ▲
ONE TOUCH LOW IDLE ▼ [Configuration] 34[%]
PRESS TO SET DIAL 2 TORQUE

ENGINE SPEED 44[%]
DIAL 3 TORQUE
↓ 54[%] ▼
Default Screen PRESS TO SET
/ :MOVE CURSOR DATA


/ :CHANGE VALUE
PARAMETER SETTING
ENGINE SPEED ▲
DIAL TORQUE Then press the up key and
AEC the down key in order to
TRV SPEED SHIFT change the value.
OVER LOAD WARNING
ONE TOUCH LOW IDLE ▼ After changing to the value
PRESS TO SET you want, press the OK key
DIAL TORQUE in order to set the value into
a machine controller.

/ :MOVE CURSOR

101
Monitoring System Operation Manual

6.9.6.3. AEC Speed SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → PARAMETER SETTING → AEC )

Go to the
AEC [Configuration]
PARAMETER SETTING
AEC2 ENG SPEED ▲ Press the up key or the
1300[RPM] down key in order to
AEC2 DELAY TIME highlight the item you want
Refer to
3[sec]
“6.9.5.1.Parameter to change setting.
Setting”

↓ PRESS TO CHANGE And press the OK key in
PARAMETER SETTING DATA order to move a highlight to
ENGINE SPEED ▲ data value.
DIAL TORQUE (Ref. next figure)
AEC
TRV SPEED SHIFT / :MOVE CURSOR AEC
OVER LOAD WARNING ↓ AEC2 ENG SPEED ▲
ONE TOUCH LOW IDLE ▼ [Configuration] 1300[RPM]
PRESS TO SET AEC2 DELAY TIME

ENGINE SPEED 3[sec]

↓ ▼
Default Screen PRESS TO SET
/ :MOVE CURSOR DATA


/ :CHANGE VALUE
PARAMETER SETTING
ENGINE SPEED ▲
DIAL TORQUE Then press the up key and
AEC the down key in order to
TRV SPEED SHIFT change the value.
OVER LOAD WARNING
ONE TOUCH LOW IDLE ▼ After changing to the value
PRESS TO SET you want, press the OK key
AEC in order to set the value into
a machine controller.

/ :MOVE CURSOR

102
Monitoring System Operation Manual

6.9.6.4. Travel Speed Shft Pressure (345C/300D Medium) SERVICE PASSWORD REQUIRED
( MAIN MENU → SERVICE → CONFIGURATIONS → PARAMETER SETTING → TRV SPEED SHIFT )

Go to the
TRV SPEED SHIFT [Configuration]
PARAMETER SETTING
LOW PRES ▲ Press the up key or the
20000[KPa] down key in order to
HIGH PRES highlight the item you want
Refer to
32000[KPa]
“6.9.5.1.Parameter to change setting.
Setting” LOW DELAY
0.4[sec] ▼
↓ PRESS TO CHANGE And press the OK key in
PARAMETER SETTING DATA order to move a highlight to
ENGINE SPEED ▲ data value.
DIAL TORQUE (Ref. next figure)
AEC
TRV SPEED SHIFT / :MOVE CURSOR TRV SPEED SHIFT
OVER LOAD WARNING ↓ LOW PRES ▲
ONE TOUCH LOW IDLE ▼ [Configuration] 20000[KPa]
PRESS TO SET HIGH PRES

ENGINE SPEED 32000[KPa]
LOW DELAY
↓ 0.4[sec] ▼
Default Screen PRESS TO SET
/ :MOVE CURSOR DATA


/ :CHANGE VALUE
PARAMETER SETTING
ENGINE SPEED ▲
DIAL TORQUE Then press the up key and
AEC the down key in order to
TRV SPEED SHIFT change the value.
OVER LOAD WARNING
ONE TOUCH LOW IDLE ▼ After changing to the value
PRESS TO SET you want, press the OK key
TRAVEL SPEED SHIFT in order to set the value into
a machine controller.

/ :MOVE CURSOR

103
Monitoring System Operation Manual

6.9.6.5. Over Load Warning Pressure SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → PARAMETER SETTING → OVER LOAD WARNING )

Go to the
OVER LOAD WARNING [Configuration]
PARAMETER SETTING
OLWD THRESH PRES ▲ Press the OK key in order to
32000[KPa] move a highlight to data
Refer to value.
“6.9.5.1.Parameter (Ref. next figure)
Setting”

↓ PRESS TO CHANGE OVER LOAD WARNING
PARAMETER SETTING DATA OLWD THRESH PRES ▲

ENGINE SPEED ▲
32000[KPa]
DIAL TORQUE
AEC
TRV SPEED SHIFT / :MOVE CURSOR

OVER LOAD WARNING ↓
ONE TOUCH LOW IDLE PRESS TO SET
▼ [Configuration] DATA
PRESS TO SET

ENGINE SPEED


/ :CHANGE VALUE
Default Screen
/ :MOVE CURSOR
↓ Then press the up key and
the down key in order to
↓ change the value.
PARAMETER SETTING
ENGINE SPEED ▲
After changing to the value
DIAL TORQUE you want, press the OK key
AEC in order to set the value into
TRV SPEED SHIFT a machine controller.
OVER LOAD WARNING
ONE TOUCH LOW IDLE ▼
PRESS TO SET
OVER LOAD WARNING

/ :MOVE CURSOR

104
Monitoring System Operation Manual

6.9.6.6. One Touch Low Idle Speed SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → PARAMETER SETTING → ONE TOUCH LOW IDLE )

Go to the
ONE TOUCH LOW IDLE [Configuration]
PARAMETER SETTING
ONE TOUCH ENG SPEED ▲ Press the OK key in order to
1300[RPM] move a highlight to data
Refer to value.
“6.9.5.1.Parameter (Ref. next figure)
Setting”

↓ PRESS TO CHANGE ONE TOUCH LOW IDLE
PARAMETER SETTING DATA ONE TOUCH ENG SPEED ▲
ENGINE SPEED ▲
1300[RPM]
DIAL TORQUE
AEC
TRV SPEED SHIFT / :MOVE CURSOR

OVER LOAD WARNING ↓
ONE TOUCH LOW IDLE PRESS TO SET
▼ [Configuration] DATA
PRESS TO SET

ENGINE SPEED


/ :CHANGE VALUE
Default Screen
/ :MOVE CURSOR
↓ Then press the up key and
the down key in order to
↓ change the value.
PARAMETER SETTING
ENGINE SPEED ▲
After changing to the value
DIAL TORQUE you want, press the OK key
AEC in order to set the value into
TRV SPEED SHIFT a machine controller.
OVER LOAD WARNING
ONE TOUCH LOW IDLE ▼
PRESS TO SET
ONE TOUCH LOW IDLE

/ :MOVE CURSOR

105
Monitoring System Operation Manual

6.9.6.7. Gain/Response (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → PARAMETER SETTING → GAIN/RESPONSE )

Go to the
GAIN/RESPONSE [Configuration]
PARAMETER SETTING
SOFT MODE GAIN ▲ Press the up key or the
4 down key in order to
SOFT MODE RESPONSE highlight the item you want
Refer to
2
“6.9.5.1.Parameter to change setting.
Setting” NORMAL MODE GAIN
4 ▼
↓ PRESS TO CHANGE And press the OK key in
PARAMETER SETTING DATA order to move a highlight to
ENGINE SPEED ▲ data value.
DIAL TORQUE (Ref. next figure)
AEC
TRV SPEED SHIFT / :MOVE CURSOR GAIN/RESPONSE
OVER LOAD WARNING ↓ SOFT MODE GAIN ▲
ONE TOUCH LOW IDLE ▼ [Configuration] 4
PRESS TO SET SOFT MODE RESPONSE

ENGINE SPEED 2
NORMAL MODE GAIN
↓ 4 ▼
Default Screen PRESS TO SET
/ :MOVE CURSOR DATA


/ :CHANGE VALUE
PARAMETER SETTING
DIAL TORQUE ▲
AEC Then press the up key and
TRV SPEED SHIFT the down key in order to
OVER LOAD WARNING change the value.
ONE TOUCH LOW IDLE
GAIN/RESPONSE ▼ After changing to the value
PRESS TO SET you want, press the OK key
GAIN/RESPONSE in order to set the value into
a machine controller.

/ :MOVE CURSOR

106
Monitoring System Operation Manual

6.9.6.8. Auto Lube System (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → PARAMETER SETTING → AUTO LUB SYSTEM )

Go to the
AUTO LUB SYSTEM [Configuration]
PARAMETER SETTING
DURATION TIME ▲ Press the up key or the
4[min] down key in order to
INTERVAL TIME highlight the item you want
Refer to
30[min]
“6.9.5.1.Parameter to change setting.
Setting”

↓ PRESS TO CHANGE And press the OK key in
PARAMETER SETTING DATA order to move a highlight to
ENGINE SPEED ▲ data value.
DIAL TORQUE (Ref. next figure)
AEC
TRV SPEED SHIFT / :MOVE CURSOR AUTO LUB SYSTEM
OVER LOAD WARNING ↓ DURATION TIME ▲
ONE TOUCH LOW IDLE ▼ [Configuration] 4[min]
PRESS TO SET INTERVAL TIME

ENGINE SPEED 30[min]

↓ ▼
Default Screen PRESS TO SET
/ :MOVE CURSOR DATA


/ :CHANGE VALUE
PARAMETER SETTING
AEC ▲
TRV SPEED SHIFT Then press the up key and
OVER LOAD WARNING the down key in order to
ONE TOUCH LOW IDLE change the value.
GAIN/RESPONSE
AUTO LUB SYSTEM ▼ After changing to the value
PRESS TO SET you want, press the OK key
AUTO LUB SYSTEM in order to set the value into
a machine controller.

/ :MOVE CURSOR

107
Monitoring System Operation Manual

6.9.6.9. Ultra High Reach Demolition (365C/385C) SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → PARAMETER SETTING → UHD )

Go to the
UHD [Configuration]
PARAMETER SETTING
UHD REQUESTED FLOW ▲ Press the OK key in order to
40[L/min] move a highlight to data
Refer to value.
“6.9.5.1.Parameter (Ref. next figure)
Setting”

↓ PRESS TO CHANGE UHD
PARAMETER SETTING DATA UHD REQUESTED FLOW ▲

ENGINE SPEED ▲
40[L/min]
DIAL TORQUE
AEC
TRV SPEED SHIFT / :MOVE CURSOR

OVER LOAD WARNING ↓
ONE TOUCH LOW IDLE PRESS TO SET
▼ [Configuration] DATA
PRESS TO SET

ENGINE SPEED


/ :CHANGE VALUE
Default Screen
/ :MOVE CURSOR
↓ Then press the up key and
the down key in order to
↓ change the value.
PARAMETER SETTING
TRV SPEED SHIFT ▲
After changing to the value
OVER LOAD WARNING you want, press the OK key
ONE TOUCH LOW IDLE in order to set the value into
GAIN/RESPONSE a machine controller.
AUTO LUB SYSTEM
UHD ▼
PRESS TO SET
UHD

/ :MOVE CURSOR

108
Monitoring System Operation Manual

6.9.6.10. Reverse Fan Operation Time SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → PARAMETER SETTING → REVERSE FAN )

Go to the
REVERSE FAN [Configuration]
PARAMETER SETTING
OPERATION TIME ▲ Press the OK key in order to
100[sec] move a highlight to data
Refer to value.
“6.9.5.1.Parameter (Ref. next figure)
Setting”

↓ PRESS TO CHANGE REVERSE FAN
PARAMETER SETTING DATA OPERATION TIME ▲

ENGINE SPEED ▲
100[sec]
DIAL TORQUE
AEC
TRV SPEED SHIFT / :MOVE CURSOR

OVER LOAD WARNING ↓
ONE TOUCH LOW IDLE PRESS TO SET
▼ [Configuration] DATA
PRESS TO SET

ENGINE SPEED


/ :CHANGE VALUE
Default Screen
/ :MOVE CURSOR
↓ Then press the up key and
the down key in order to
↓ change the value.
PARAMETER SETTING
OVER LOAD WARNING ▲
After changing to the value
ONE TOUCH LOW IDLE you want, press the OK key
GAIN/RESPONSE in order to set the value into
AUTO LUB SYSTEM a machine controller.
UHD
REVERSE FAN ▼
PRESS TO SET
REVERSE FAN

/ :MOVE CURSOR

109
Monitoring System Operation Manual

6.9.6.11. Main Pump Load Initial Torque SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → CONFIGURATIONS → PARAMETER SETTING
→ M-PUMP/LI TORQUE )

M-PUMP/LI TORQUE
Go to the
LOAD INIT TORQUE ▲
[Configuration]
PARAMETER SETTING 5[%]
Press the OK key in order to
Refer to move a highlight to data
“6.9.5.1.Parameter value.
Setting” (Ref. next figure)

↓ PRESS TO CHANGE
PARAMETER SETTING DATA M-PUMP/LI TORQUE
ENGINE SPEED ▲ LOAD INIT TORQUE ▲
DIAL TORQUE 5[%]
AEC
TRV SPEED SHIFT / :MOVE CURSOR
OVER LOAD WARNING ↓
ONE TOUCH LOW IDLE ▼ [Configuration] ▼
PRESS TO SET PRESS TO SET

ENGINE SPEED DATA


Default Screen
/ :MOVE CURSOR / :CHANGE VALUE

Then press the up key and
↓ the down key in order to
PARAMETER SETTING change the value.
ONE TOUCH LOW IDLE ▲
GAIN/RESPONSE After changing to the value
AUTO LUB SYSTEM you want, press the OK key
UHD in order to set the value into
REVERSE FAN a machine controller.
M-PUMP/LI TORQUE ▼
PRESS TO SET
REVERSE FAN

/ :MOVE CURSOR

110
Monitoring System Operation Manual

Configuration Item List (1/4)

365C/385C
345C
Display Description

ATCH PARTS INST : Attachment Parts Installation


HYD OIL TYPE x x Hydraulic Oil Type
TRAVEL ALARM x x Travel Alarm Installation Status
WATER SEPARATOR SW x x Water Separator Level Switch Configuration
FUEL FILTER SW x x Engine Fuel Filter Configuration
2ND FUEL FILTER SW x x Secondary Fuel Filter Configuration
ATCH HYD OIL FLTR SW x x Attachment Hydraulic Oil Filter Switch Configuration
AUTO LUB SYSTEM x - Auto Lube System Configuration
OLW SENSOR x x Machine Overload Pressure Sensor Installation Status
STRAIGHT TRV PEDAL x - Straight Travel Pedal Installation Status
BOOM LOWERING CHECK x - Boom Check Valve Configuration
STICK LOWERING CHECK x - Stick Check Valve Configuration
ENG COOLING FAN MAP x x Engine Cooling Fan Map
TOP ENG FAN SPEED x - Engine Cooling Fan Top Speed
REVERSE FAN x x Engine Fan Reversing Feature Installation Status
MSS x x Advanced Machine Security System Installation Status
HEAVY LIFT - x Heavy Lift System Installation Status
QUICK COUPLER - x Quick Coupler Installation Status
FINE SWING - x Fine Swing System Installation Status

TOOL INSTLLATION : Tool Installation


AUX PEDAL x - Auxiliary Pedal Installation Status
MEDIUM PRES CIRCUIT x - Medium Pressure Hydraulic Circuit Configuration
AUX CIRCUIT x - Auxiliary Hydraulic Circuit #1 Configuration
JOYSTICK HANDLE x - Joystick Handle Configuration
MACHINE APPLICATION - x Machine Application Configuration
ATCH ECM INSTALLATION - x Attachment Controller Install Status
FLOW LIMIT VALVE - x Main Pump Flow Limitation Control Valve Installation Status
ATCH VALVE #1 - x Attachment Valve #1 Configuration
ATCH VALVE #3 - x Attachment Valve #3 Configuration
COMBINER VALVE - x Attachment Valve #1 Combiner Configuration
VARIABLE RELIEF #1 - x Variable Relief Valve #1 Configuration
VARIABLE RELIEF #2 - x Variable Relief Valve #2 Configuration
TOOL LOAD PRES SENSOR - x F2 Type Valve Load Sense Pressure Sensor Installation Status

111
Monitoring System Operation Manual

Configuration Item List (2/4)

365C/385C
345C

Display Description

CONTROL INST : Control Input Installations


LEFT JOYSTICK SW #1 x x Left Joystick Switch #1 Installation Status
LEFT JOYSTICK SW #2 x x Left Joystick Switch #2 Installation Status
RIGHT JOYSTICK SW #1 x x Right Joystick Switch #1 Installation Status
RIGHT JOYSTICK SW #2 x x Right Joystick Switch #2 Installation Status
ATCH SW #1 - x Attachment Switch #1 Installation Status
ATCH SW #2 - x Attachment Switch #2 Installation Status
ATCH SW #3 - x Attachment Switch #3 Installation Status
ATCH SW #4 - x Attachment Switch #4 Installation Status
LEFT THUMBWHEEL x x Left Joystick Thumbwheel Installation Status
RIGHT THUMBWHEEL x x Right Joystick Thumbwheel Installation Status
ATCH LEFT PEDAL - x Left Attachment Pedal Installation Status
ATCH RIGHT PEDAL - x Right Attachment Pedal Installation Status
JOYSTICK INPUT #1 x - Joystick Input #1 Configuration
JOYSTICK INPUT #2 x - Joystick Input #2 Configuration
JOYSTICK INPUT #3 x - Joystick Input #3 Configuration
JOYSTICK INPUT #4 x - Joystick Input #4 Configuration
AUX PRI FLOW MODE x - Auxiliary Priority Flow Mode Enable

FRONT LINKAGE : Front Linkage Configurations


BUCKET TYPE x - Bucket Configuration

PRODUCT ID : Product Identification Number


PRODUCT ID x x Product Identification Number

112
Monitoring System Operation Manual

Configuration Item List (3/4)

365C/385C
345C

Display Description

ENGINE SPEED : Throttle Dial Engine Speed


DIAL 1 SPEED x x Throttle Dial Position 1 Engine Speed
DIAL 2 SPEED x x Throttle Dial Position 2 Engine Speed
DIAL 3 SPEED x x Throttle Dial Position 3 Engine Speed
DIAL 4 SPEED x x Throttle Dial Position 4 Engine Speed
DIAL 5 SPEED x x Throttle Dial Position 5 Engine Speed
DIAL 6 SPEED x x Throttle Dial Position 6 Engine Speed
DIAL 7 SPEED x x Throttle Dial Position 7 Engine Speed
DIAL 8 SPEED x x Throttle Dial Position 8 Engine Speed
DIAL 9 SPEED x x Throttle Dial Position 9 Engine Speed
DIAL 10 SPEED x x Throttle Dial Position 10 Engine Speed

DIAL TORQUE : Throttle Dial Hydraulic Power Percentage


DIAL 1 TORQUE x x Throttle Dial Position 1 Hydraulic Power Percentage
DIAL 2 TORQUE x x Throttle Dial Position 2 Hydraulic Power Percentage
DIAL 3 TORQUE x x Throttle Dial Position 3 Hydraulic Power Percentage
DIAL 4 TORQUE x x Throttle Dial Position 4 Hydraulic Power Percentage
DIAL 5 TORQUE x x Throttle Dial Position 5 Hydraulic Power Percentage
DIAL 6 TORQUE x x Throttle Dial Position 6 Hydraulic Power Percentage
DIAL 7 TORQUE x x Throttle Dial Position 7 Hydraulic Power Percentage
DIAL 8 TORQUE x x Throttle Dial Position 8 Hydraulic Power Percentage
DIAL 9 TORQUE x x Throttle Dial Position 9 Hydraulic Power Percentage
DIAL 10 TORQUE x x Throttle Dial Position 10 Hydraulic Power Percentage

AEC : AEC Mode Setting


AEC2 ENG SPEED x x AESC Engine Speed Setting
AEC2 DELAY TIME x x AESC Delay Time

113
Monitoring System Operation Manual

Configuration Item List (4/4)

365C/385C
345C

Display Description

TRV SPEED SHIFT : Travel Speed Shift


LOW PRES - x Travel Speed Shift Low Delay Time
HIGH PRES - x Travel Speed Shift High Delay Time
LOW DELAY - x Travel Speed Shift Low Pressure
HIGH DELAY - x Travel Speed Shift High Delay Time

OVERLOAD WARNING : Machine Over Load


OLWD THRESH PRES x x Machine Overload Pressure Threshold

ONE TOUCH LOW IDLE : One Touch Low Idle Engine Speed
ONE TOUCH ENG SPEED x x One Touch Engine Speed Setting

GAIN/RESPONSE : Gain/Response Setting


SOFT MODE GAIN x - Soft Mode Gain Setting
SOFT MODE RESPONSE x - Soft Mode Response Setting
NORMAL MODE GAIN x - Normal Mode Gain Setting
NORMAL MODE RESPONSE x - Normal Mode Response Setting
QUICK MODE GAIN x - Quick Mode Gain Setting
QUICK MODE RESPONSE x - Quick Mode Response Setting

AUTO LUB SYSTEM : Auto Lube System Setting


DURATION TIME x - Auto Lube Duration
INTERVAL TIME x - Auto Lube Interval

UHD : Ultra High Demolition Machine Setting


UHD REQUESTED FLOW x - High Power Auxiliary Circuit Flow Rate

REVERSE FAN : Engine Fan Reversing Feature Setting


OPERATION TIME x x Engine Fan Reverse Operation Time

M-PUMP/LI TORQUE : Main Pump Load Initial Torque Setting


LOAD INIT TORQUE - x Main Pump Load Initial Torque

114
Monitoring System Operation Manual

6.10. Tool Program SERVICE PASSWORD REQUIRED


( MAIN MENU → SERVICE → TOOL PROGRAM )

Go to the
TOOL PROGRAM [Configuration]
SERVICE
TOOL #1 ▲ Press the up key or the
TOOL #2 down key in order to
TOOL #3 highlight the item you want
Refer to
TOOL #4
“6.Service” to change setting.
TOOL #5
↓ ▼
SERVICE PRESS TO PROGRAM And press the OK key in
MAINTENANCE ▲ TOOL #1 order to move a highlight to
PASSWORD CHANGE data value.
DIAGNOSTIC (Ref. next figure)
ECM INFO
STATUS / :MOVE CURSOR TOOL #??
CALIBRATIONS ▼ ↓ NAME ▲
PRESS TO CHANGE 0
MAINTE INFO MAX DIAL
+
10
MIN DIAL
↓ 1 ▼
/ :MOVE CURSOR PRESS TO SET
Select a tool
↓ DATA

↓ TOOL #??
NAME ▲ / :MOVE CURSOR
SERVICE / :CHANGE VALUE
STATUS ▲
0
CALIBRATIONS MAX DIAL
DEVICE TEST 10 Then press the up key and
OVERRIDE MIN DIAL the down key in order to
CONFIGURATIONS 1 ▼ change the value.
TOOL PROGRAM ▼ PRESS TO CHANGE
DATA
PRESS TO PROGRAM After changing to the value
TOOL you want, press the OK key
in order to set the value into
/ :MOVE CURSOR a machine controller.
/ :MOVE CURSOR ↓
[Configuration] Note: The indication item

varies by the model. And

the item which is checked at
↓ the next table may not be
↓ indicated by the machine
Default Screen configuration.

115
Monitoring System Operation Manual

Tool Program List(


(1/3)

365C/385C
345C

Display Description
NAME x x Tool Program Name
MAX DIAL x x Tool Program Maximum Throttle Dial Position
MIN DIAL - x Tool Program Minimum Throttle Dial Position
UNDERSPEED ENABLE - x Tool Program Under Speed Enable
COMBINER ENABLE - x Tool Program Two Pump Flow Combine Enable
WARNING TEMP - x Tool Program Hydraulic Temperature High Warning Event Threshold
ONE OR TWO WAY - x Tool Program One Way/ Two Way Valve Mode
VAR RELIEF #1 PRES - x Tool Program Variable Relief Valve #1 Pressure
VAR RELIEF #2 PRES - x Tool Program Variable Relief Valve #2 Pressure
F2 DERATE MAX PRES - x F2 Type Valve Maximum Derate Control Pressure
F2 SQEZ START PRES - x F2 Type Valve Pressure Derate Start Pressure
F2 SQEZ END PRES - x F2 Type Valve Pressure Derate End Pressure
Multiple Operation Maximum Extend Pilot Pres for Combined
F2 MULTI OPE EXTND - x
Attachment Valve
Multiple Operation Maximum Retract Pilot Pres for Combined
F2 MULTI OPE RETCT - x
Attachment Valve
MOD L JOYSTK SW #1 x x Tool Program Left Joystick Switch #1 Control Mode
MOD L JOYSTK SW #2 x x Tool Program Left Joystick Switch #2 Control Mode
MOD R JOYSTK SW #1 x x Tool Program Right Joystick Switch #1 Control Mode
MOD R JOYSTK SW #2 x x Tool Program Right Joystick Switch #2 Control Mode
JOYSTK INPUT #1(PR) x - Tool Program Proportional Joystick #1 Valve Configuration
JOYSTK INPUT #4(PR) x - Tool Program Proportional Joystick #4 Valve Configuration
JOYSTK INPUT #1 x - Tool Program Joystick #1 Switch Valve Configuration
JOYSTK INPUT #2 x - Tool Program Joystick #2 Switch Valve Configuration
JOYSTK INPUT #3 x - Tool Program Joystick #3 Switch Valve Configuration
JOYSTK INPUT #4 x - Tool Program Joystick #4 Switch Valve Configuration
MOD L THUMBWHEEL x x Tool Program Left Joystick Thumbwheel Control Mode
MOD R THUMBWHEEL x x Tool Program Right Joystick Thumbwheel Control Mode
ATCH LEFT PEDAL - x Tool Program Left Attachment Pedal Control Mode
ATCH RIGHT PEDAL - x Tool Program Right Attachment Pedal Control Mode
ATCH PEDAL x - Tool Program Proportionally Auxiliary Pedal Valve Configuration

116
Monitoring System Operation Manual

Tool Program List(


(2/3)

365C/385C
345C

Display Description
ATCH #1 TOOL SW - x Tool Program Attachment Switch #1 Control Mode
ATCH #2 TOOL SW - x Tool Program Attachment Switch #2 Control Mode
ATCH #3 TOOL SW - x Tool Program Attachment Switch #3 Control Mode
ATCH #4 TOOL SW - x Tool Program Attachment Switch #4 Control Mode
ATCH VALVE MODE x - Tool Program Auxiliary Valve #1 Mode
ATCH MAX EXT FLOW x - Tool Program Auxiliary Valve #1 Maximum Extend Flow Rate
ATCH EXT OPEN RATE x - Tool Program Auxiliary Valve #1 Extend Open Rate
ATCH EXT CLOSE RATE x - Tool Program Auxiliary Valve #1 Extend Close Rate
ATCH MAX RET FLOW x - Tool Program Auxiliary Valve #1 Maximum Retract Flow Rate
ATCH RET OPEN RATE x - Tool Program Auxiliary Valve #1 Retract Open Rate
ATCH RET CLOSE RATE x - Tool Program Auxiliary Valve #1 Retract Close Rate
PRI MIN EXT FLOW x - Auxiliary Minimum Extend Flow
PRI EXT RED PRES x - Extend Flow Reduction Pressure
PRI EXT RELIEF PRES x - Extend Relief Pressure
PRI MIN RET FLOW x - Auxiliary Minimum Retract Flow
PRI RET RED PRES x - Retract Flow Reduction Pressure
PRI RET RELIEF PRES x - Extend Relief Pressure
Tool Program Medium Pressure Circuit #1-A Maximum Solenoid
MED C1-A MAX SOL x -
Current
Tool Program Medium Pressure Circuit #1-A Minimum Solenoid
MED C1-A MIN SOL x -
Current
MED C1-A OPEN RATE x - Tool Program Medium Pressure Circuit #1-A Open Rate
MED C1-A CLOSE RATE x - Tool Program Medium Pressure Circuit #1-A Close Rate
Tool Program Medium Pressure Circuit #1-B Maximum Solenoid
MED C1-B MAX SOL x -
Current
Tool Program Medium Pressure Circuit #1-B Minimum Solenoid
MED C1-B MIN SOL x -
Current
MED C1-B OPEN RATE x - Tool Program Medium Pressure Circuit #1-B Open Rate
MED C1-B CLOSE RATE x - Tool Program Medium Pressure Circuit #1-B Close Rate
Tool Program Medium Pressure Circuit Main Pump Power Reduction
INIT PUMP POWER RED x x
(Initial)
Tool Program Medium Pressure Circuit Main Pump Power Reduction
TOTAL PUMP POW RED x x
(Total)

117
Monitoring System Operation Manual

Tool Program List(


(3/3)

365C/385C
345C

Display Description
A1 FLOW - x Tool Program Attachment Valve #1 Flow Setting
A1 MULTI ADD FLOW - x Tool Program Attachment Valve #1 Multi-Operation Additional Flow
A1 NOMINAL PRES - x Tool Program Attachment Valve #1 Nominal Pressure
A1 OPEN TIME - x Tool Program Attachment Valve #1 Open Time
A1 CLOSE TIME - x Tool Program Attachment Valve #1 Close Time
A1 EXTND MAX PRES - x Tool Program Attachment Valve #1 Maximum Extend Pressure
A1 RETCT MAX PRES - x Tool Program Attachment Valve #1 Maximum Retract Pressure
A3 FLOW - x Tool Program Attachment Valve #3 Flow Setting
A3 MULTI ADD FLOW - x Tool Program Attachment Valve #3 Multi-Operation Additional Flow
A3 NOMINAL PRES - x Tool Program Attachment Valve #3 Nominal Pressure
A3 OPEN TIME - x Tool Program Attachment Valve #3 Open Time
A3 CLOSE TIME - x Tool Program Attachment Valve #3 Close Time
A3 EXTND MAX PRES - x Tool Program Attachment Valve #3 Maximum Extend Pressure
A3 RETCT MAX PRES - x Tool Program Attachment Valve #3 Maximum Retract Pressure

118
Monitoring System Operation Manual

Appendix A. MID List


MID List (1/1)
MID Module Description
39 Machine ECM ( 300D : B4M1)
105 Machine ECM ( 345C : STD Controller)
39 Machine ECM ( 365C,385C : ABL2C+ )
36 Engine ECM(ADEM)
106 Attachment Controller(345C : ATTController)
30 Monitor
124 MSS
122 Product Link

119
Monitoring System Operation Manual

Appendix B. CID List


CID List (1/4)
CID Component Description
41 +8V DC Supply
91 Throttle Position Sensor
96 Fuel Level Sensor
100 Engine Oil Pressure Sensor
110 Engine Coolant Temperature Sensor
145 12 Volt DC Power Supply
167 Alternator Charging Voltage Sensor
168 Electrical System Voltage
171 Ambient Air Temperature Sensor
190 Engine Speed Sensor
246 Proprietary CAN Data Link
247 SAE J1939 Data Link
248 CAT Data Link
253 Personality Module
254 Electronic Control Module
262 5 Volt Sensor DC Power Supply
263 Digital Sensor Power Supply (8V or 12V)
268 Programmed Parameter Fault
271 Action Alarm
291 Engine Cooling Fan Solenoid
295 Large Hydraulic Excavator Control Module
324 Warning Lamp (Action)
362 Engine Fan Speed Control Solenoid
374 Swing Brake Solenoid
376 Travel Alarm
379 Machine Auto Lube Pressure Sensor
466 Left Track Steering Pedal Position Sensor
467 Right Track Steering Pedal Position Sensor
485 Auto Reverse Fan Solenoid
544 Engine Cooling Fan Speed Sensor
545 Ether Injection Control Relay
558 Auto Lube Relay
581 Power Shift Solenoid

120
Monitoring System Operation Manual

CID List (2/4)


CID Component Description
583 Boom Raise Solenoid
586 Engine Speed Dial Switch
587 Engine Governor Position Sensor
588 Monitoring System Display
590 Engine Control Module
598 Travel Speed Solenoid
600 Hydraulic Oil Temperature Sensor
732 Fine Swing Solenoid
735 Heavy Lift Solenoid
790 Swing Pump (Outlet) Pressure Sensor
799 Service Tool
864 Variable Implement Hydraulic Pump Pressure Sensor
1073 VIDS Display Module
1118 Neutral Flow Bypass Solenoid
1119 Boom Anti Drift Solenoid
1120 Stick Anti Drift Solenoid
1121 Front System High Pressure Solenoid
1124 Anti Theft Solenoid
1125 Left Hand Lever Forward/Backward Position Sensor
1126 Left Hand Lever Left/Right Position Sensor
1127 Right Hand Lever Forward/Backward Position Sensor
1128 Right Hand Lever Left/Right Position Sensor
1129 Right Side Attachment Pedal Sensor
1130 Left Side Attachment Pedal Sensor
1131 Joystick Switch #1
1132 Joystick Switch #4
1138 Boom Cylinder Rod Retract Solenoid
1139 Stick Cylinder Rod Extend Solenoid
1140 Stick Cylinder Rod Retract Solenoid
1141 Bucket Cylinder Rod Extend Solenoid
1142 Bucket Cylinder Rod Retract Solenoid
1143 Swing Right Solenoid
1144 Swing Left Solenoid
1145 Attachment Extend/CW Solenoid

121
Monitoring System Operation Manual

CID List (3/4)


CID Component Description
1146 Attachment Retract/CW Solenoid
1147 Medium Pressure Circuit #1-A Solenoid
1148 Medium Pressure Circuit #1-B Solenoid
1149 Boom Lowering Check/Modulation Valve Solenoid
1150 Swing Pump Swash Plate Angle Solenoid
1155 Implement Pump Power Shift Pressure Solenoid
1159 Stick Lowering Check/Modulation Valve Solenoid
1160 Hydraulic Lock Solenoid
1161 Front Hydraulic Pump Pressure Sensor
1162 Rear Hydraulic Pump Pressure Sensor
1163 Left Travel Backward Solenoid
1164 Right Travel Backward Solenoid
1165 Right Travel Forward Solenoid
1166 Left Travel Forward Solenoid
1178 Machine Overload Warning Pressure Sensor
1191 Main Hydraulic Valve
1192 Swing Hydraulic Valve
1193 Boom Cylinder Rod Extension Solenoid
1522 Relief Valve #2 Check Valve Solenoid
1523 Relief Valve #1 Check Valve Solenoid
1525 Straight Travel Solenoid
1590 Main Pump Flow Limitation Pressure Solenoid
1591 Negative Flow Control Stabilizer Pressure Solenoid
1593 Attachment Valve #1 Extend Pressure Solenoid
1594 Attachment Valve #2 Extend Pressure Solenoid
1595 Attachment Valve #3 Extend Pressure Solenoid
1596 Attachment Valve #1 Retract Pressure Solenoid
1597 Attachment Valve #2 Retract Pressure Solenoid
1598 Attachment Valve #3 Retract Pressure Solenoid
1609 F2 Type Valve Load Sense Pressure Sensor
1615 One Way / Two Way Valve Solenoid
1657 Left Joystick Thumbwheel
1658 Right Joystick Thumbwheel
1659 F1 Type Valve Load Sense Pressure Sensor

122
Monitoring System Operation Manual

CID List (4/4)


CID Component Description
1660 Left Pump Negative Flow Control Pressure Reducer Pressure Solenoid
1661 Right Pump Negative Flow Control Pressure Reducer Pressure Solenoid
1662 F1 Type Valve Flow Command Solenoid
1663 Attachment Valve #4 Extend Pressure Solenoid
1664 Attachment Valve #4 Retract Pressure Solenoid
1665 Variable Relief Valve #1 Pressure Solenoid
1666 Variable Relief Valve #2 Pressure Solenoid
1680 Right Main Pump to Tank Bypass Solenoid
1688 Left Pump Negative Flow Control Pressure Reducer Pressure Sensor
1689 Right Pump Negative Flow Control Pressure Reducer Pressure Sensor
1849 Engine Fan Reversing Relay
1931 Auxiliary Circuit Flow Combining Solenoid
2265 Hydraulic Pump #1 Outlet Pressure Sensor
2266 Hydraulic Pump #2 Outlet Pressure Sensor
2280 Travel Alarm Relay
2300 Switch Panel

Appendix C. FMI List


FMI List (1/1)
FMI Failure Description
0 Data valid but above normal operational range
1 Data valid but below normal operational range
2 Data erratic, intermittent, or incorrect
3 Voltage above normal or shorted high
4 Voltage below normal or shorted low
5 Current below normal or open circuit
6 Current above normal or grounded circuit
7 Mechanical system not responding properly
8 Abnormal frequency, pulse width, or period
9 Abnormal update
10 Abnormal rate of change
11 Failure mode not identifiable
12 Bad device or component
13 Out of calibration

123
Monitoring System Operation Manual

Appendix D. EID List


EID List (1/1)
EID Event Description
5 Fuel Filter Restriction Derate
15 High Engine Coolant Temperature Derate
16 High Engine Coolant Temperature Shutdown
17 High Engine Coolant Temperature Warning
23 High Hydraulic Oil Temperature Derate
25 High Inlet Air Temperature Derate
27 High Inlet Air Temperature Warning
39 Low Eigine Oil Pressure Derate
43 Low System Voltage Warning
50 High System Voltage Warning
53 Low Fuel Pressure Warning
59 Low Engine Coolant Level Warning
95 Fuel Filter Restriction Warning
96 High Fuel Pressure
100 Low Engine Oil Pressure Warning
119 Low Fuel Level
171 Low Engine Oil Level
172 High Air Filter Restriction
179 Alternator Not Charging
180 Auto Lube Distribution Line Plugged
181 Limited Mobility Mode
182 Suction Valve Off
190 Engine Overspeed Warning
232 High Fuel/Water Separator Water Level
234 Low Auto Lube Grease Level
235 Low Hydraulic Oil Level
236 Return Hydraulic Oil Filter Plugged
237 Machine Overloaded
237 Machine Overloaded
265 User Defined Shutdown
272 Inlet Air Restriction Warning
273 Unauthraized Key
600 High Hydraulic Oil Temperature Warning
862 Attachment Hydraulic Oil Filter Plugged
863 Abnormal Machine Auto Lube System Operation

124
Monitoring System Operation Manual

Appendix E. DSI List


DSI List (1/1)
DSI Data Status Description
2 Erratic, Intermittent or Incorrect Data
3 Voltage High
4 Voltage Low
5 Current Below Normal
6 Current Above Normal
8 Abnormal Frequency, Pulse Width, or Period
9 Abnormal Update
11 Other Failure Mode
12 Bad Component
13 Out of Calibration
16 Parameter not available
17 Module not responding
18 Sensor Power Supply Failure
19 Incomplete Data or Conditions Not Met
20 Disabled or Not Installed

125
Monitoring System Operation Manual

Appendix F. RROR ID List


CALIBRATION ERROR ID List (1/1)
ID Event Description
$0001 ECM Fault
$0002 Active Diagnostic Present
$0003 Another Calibration is Active
$0004 Calibration Active by Another ECM
$0005 Loss of Calibration Interlock
$0006 Calibration Aborted by Tool/Monitor
$0007 Requested Display Not Supported
$0008 Unavailable Display
$0009 Calibration Aborted by ECM
$000A Calibration Failure
$000B Calibration Not Supported
$0100 Out-of-Range Low - Incr/Decr parameter
$0101 Out-of-Range High - Incr/Decr parameter
$0102 Invalid Action/Key Stroke Command
$0103 Calibration Value Out-of-Range
$0104 Calibrated Range Too Small
$0105 Calibrated Range Too Large
$0106 Calibration Value Not Saved
$1000 See Service Manual
$1010 Engine Stopped (No Engine RPM)
$1011 Engine Running (Engine RPM Present)
$1012 Engine RPM Incorrect
$1013 Engine High Idle RPM Too Fast
$1014 Engine Low Idle RPM Too Slow
$1015 Abnormal Engine RPM Signal
$1016 Speed Sensor Circuit Is Open
$1017 Service Brake Pedal Pressed
$1018 Parking Brake Not Engaged
$1019 Parking Brake Engaged
$101A Implement is swinging/travelling
$101B Machine Speed Not Zero

126