MODEL 06260 INSTRUCTION SHEET 06260-90

REV 04-98
PROTECTIVE COVER FOR WIND TRACKERLD

INTRODUCTION
3. In mounting surface, drill 8 mounting holes. (1/8" drill).
The Protective Cover provides moisture and dust protection Drill clearance hole in mounting surface for wires.
for the Wind Tracker display. The clear window permits
easy viewing of display information while the sealed buttons 4. Pass sensor cable and power supply cable through
allow operation of brightness and reset controls. back plate. Attach sensor wires to display terminals.
Insert power supply plug into jack on back of display.
INSTALLATION
5. Attach display to back plate using 2 ea no 8 screws
The Protective Cover may be installed on any flat surface. It provided.
is supplied as two components; a Front Cover and a Back
Plate. Installation is as follows: 6. Align front cover and back plate with holes in mounting
surface. Fasten using 8 self tapping screws provided.
1. Select a location for the Display and Protective Cover
that permits good viewing. MAINTENANCE

2. Using the back plate as a template, mark locations for 8 Dirt or dust accumulation may be cleaned using soap and
screws and the clearance hole for wiring connections. water and a soft cloth. Do not use abrasive cleaners. DO
NOT USE SOLVENTS.

R. M. YOUNG COMPANY 2801 Aero Park Drive, Traverse City, Michigan 49686 USA
TEL: 616-946-3980 FAX: 616-946-4772