Innovations in Communications

since 1955 PK-543A


5-4-3 WIRE APARTMENT INTERCOM AMP
WIRING INSTRUCTIONS

APPLICATION Figure A Suite Stations:


TM
ENTERCOM Apartment Entry Intercoms provide two- To Additional For 3-wire stations:
way communications between the building entrance and Suites
1 twisted pr #22, plus 1 cond.
each suite/apartment. Hands-free loudspeaker operation at #22 gauge per suite in riser
the entrance panel and push button controlled Add Risers or,
as Required For 4-wire stations:
communication at the suite locations provide for easy


operation. Controlled door entry is permitted by push button 1 twisted pr #22, plus 1 cond.


#22 common, plus 1 cond. #22
operation at the suite in conjunction with electric door


gauge per suite in riser
release.


○ ○ ○
or,


Optional equipment is available to provide additional For 5-wire stations:


1 twisted pair #22, plus 2
functions such as post office (USPS) key door release,
Entry cond. #22, plus 1 cond. #22
additional entrance panels, strobe light call indication per suite in riser
(LI-404B) and auxiliary relay (RY-014B) for ancillary Panel
Door
device operation (bells, lights, etc.). Opener
120 VAC
2 cond #18 Transformer
PROCEDURE
1. Read installation instructions to determine equipment
WIRING
location and installation methods.
2. Install housings (or back boxes) and wiring. Suite/Apartment Stations
3. Check wiring, connect and install equipment. Stations may be connected in risers using the cable
4. Apply power and check operation. configurations shown in Figure A, above.
The maximum cable length is 400 feet (120 meters).
EQUIPMENT LOCATION Additional risers may be added as needed. Station
cables must not be run in the same conduit with (or
Suite/Apartment Stations
too close to) electrical wiring or background music,
Locate suite stations (also known as remote stations)
and must not be close to fluorescent lights, dimmers or
where convenient for use. See Figure A (page1) for riser
other electrical equipment. Failing to observe this
diagram, or Figure 1 (page 4) for wiring/hook-up
requirement can result in noise entering the intercom
diagram.
audio. Ensure that sufficient amounts of cable are left
in the back box to make connections to stations. Do
Entrance/Lobby Panel
not cut cable at each station.
Locate the entrance panel where it is sheltered from
weather. If it must be mounted outdoors, consider wind Transformer
direction and optional Rain-Guard weather hood. Cable wiring must be 2 conductor #18 AWG with a
maximum cable length of 80 feet (25 meters). If using
PK-543A Amplifier
#14 AWG wire, this distance can be extended to 200
Install amplifier inside the entrance panel if space
feet (60 meters). Route cable away from suite station
permits. If necessary to install the amplifier elsewhere
wiring and maintain a minimum of 3 feet (1 meter) of
due to temperature extremes (operating temperature
clearance between the transformer and the amplifier.
range is 0–30°C) or because the panel is not large
enough to house the amplifier, then use a 2 conductor
shielded cable for the entrance panel speaker (connect
shield drain to amplifier terminal G). Refer to
Connections Section, Item #3 for further details.

800-231-1414 • 631-231-1414 INTERCOMS • MAILBOXES • DIRECTORIES


155 Adams Avenue • Hauppauge, NY 11788-3699 ANNUNCIATORS • WIRE & CABLE • NURSE-CALL
Fax 631-231-1498 • www.LEEDAN.com With continuous product improvement, specifications are subject to change without notice.

©2010 LEE DAN® Communications, Inc. All Rights Reserve IN-826 (3/10)
Door Release Medium Door Time Set SW1 to OFF (left) and SW2 to
Cable wiring must be 2 conductor #18 AWG with a ON (right), 10 seconds.
maximum length of 50 feet (15 meters). See Figure
2—PK-543A 'Door Strike Applications' for specifics of Long Door Time Set SW1 to OFF (left) and SW2 to
each door control unit configuration. Note: A PS-30A OFF (left), 25 seconds.
transformer must be used for 24 VAC door strike and Entrance Tone Set SW3 to ON (right) to activate this
12 VDC Maglock applications (8 volt tap required). feature—must use warble tone.
Postal Timer Set SW4 to ON (right) and SW5 to
CONNECTIONS OFF (left) to make postal control
Before connecting to unit and applying power, verify that timer independent at 25 seconds
wires are free from shorts and grounds. Make connections PK-543 Compatible Set SW4 to OFF (left) and SW5 to
as per Figure 1—PK-543A Wiring Diagram. Observe the ON (right) for PK-543 (old style)
following notes: drop-in replacement*.
1. Do not apply power to the transformer primary until the Door Hold Time Out Set SW6 to OFF (left) to activate this
entire system has been installed and checked for shorts feature.
and grounds. The common wires connecting to terminals
1, 2, 3, E and 5 must show open circuit when tested with Talk Interlock Set SW7 to OFF (left) to activate this
an ohmmeter. feature (available for 4-wire stations
only).
2. Use twisted pair wiring as shown. Do not interchange
wires or reverse polarity! * For PK-543 (old style) Compatible mode, set SW4
OFF, SW5 ON, SW6 ON & SW7 ON. Also remove JP5
3. Install PK-543A amplifier inside the entrance panel if shunt, set J2 to shunt 1–2 and set J1 shunt to 2–3.
space permits. If it is necessary to install the amplifier
elsewhere due to temperature extremes (operating The Entrance Tone setting, when active, will generate a user
temperature range is 0–30°C) or because the entrance feedback tone at the entrance panel when visitors press call
panel is not large enough to house the amplifier, then buttons. If the warble tone is in use and the entrance tone
use a 2 conductor shielded cable for the entrance panel feature is active, the tone will also be heard through the
speaker (connect shield drain to amplifier terminal G). entrance panel speaker when the call button is pressed.
4. The amplifier must be located at least 3 feet (1 meter) The Door Hold Time Out setting, when active, will allow
from the transformer or other electrical devices. the door control device (door strike, maglock, etc.) to time
out normally, despite the DOOR button being held at the suite.
5. Do not run wiring for station common wires and
entrance panel speaker in the same cable and/or SAFETY TIP: The Talk Interlock setting, when active, will
conduit. This will cause feedback on the system. require that the TALK button (at the suite) is pressed before
the DOOR button will activate the door control device.
6. Door release wiring should be run separate from
entrance panel speaker wiring.
OPTIONAL ACCESSORIES
SHUNT AND DIPSWITCH SETTINGS Install optional accessories according to the instructions
provided.
Set the dipswitches on the PK-543A as per application
requirements. See also Figure 3—PK-543A 'Shunts and Finish & TEST Installation
Settings'. The selectable features and controls are as follows: 1. Confirm that all equipment is properly installed.
Shunt JP5 Install for maglock applications. Maximum 2. Connect power to transformer primary (120 VAC),
current for maglock is 500 mA at 12 VDC, or and ensure that local electrical codes have been
250 mA at 24 VDC. complied with.
Shunt J2 Place shunt across: 1–2 for door strike 3. At the entrance panel, push each button and verify that
applications; 2–3 for maglock applications. the correct suite is called.
Shunt J1 Place shunt across: 1–2 for +12 VDC 4. At each suite, push the TALK and LISTEN buttons to
maglock; 2–3 for +24 VDC maglock or communicate with a person at the entrance panel. Then
AC/DC door strike applications. push the DOOR button to confirm that the door release
Short Door Time Set SW1 to ON (right) and SW2 to operates correctly.
OFF (left), 2 seconds

Page 2 • IN-826 PK-543A Installation Instructions Copyright © Lee Dan Communications, Inc. All Rights Reserved.
ADJUSTMENTS SIGNAL FLOW AND THEORY OF
Voice Volume and Tone Volume can be adjusted on the OPERATION FOR PK-543A AMPLIFIER
amplifier, via the access hole, with a small screwdriver. AND APARTMENT INTERCOM SYSTEM
The following example describes an apartment intercom
TROUBLESHOOTING system using a PK-543A in conjunction with a 4-wire suite
(refer to theory drawing for additional information) station. Refer also to Figure 4—PK-543A Theory Diagram.
Entire System Dead Call Button
If power LED is not illuminated, check for 16 VAC at Pressing a suite station call button on the entrance panel
transformer secondary and 120 VAC at transformer routes the call tone from the Z or ZW terminal on the
primary. If LED is illuminated, review field wiring and PK-543A to the X terminal (tone in) on the associated
perform direct test using one of the apartment stations suite station. This signal then passes through the speaker
to eliminate field wiring. and returns to the PK-543A via the 1 terminal (audio
common). If the warble tone is in use and the entrance
No Talk tone feature is active, the tone will also be heard through
Check wiring to terminals 1 and 2, and check whether the entrance panel speaker when the call button is
wiring to entrance panel speaker is shorted or open. Suite pressed.
station can be swap tested with another working unit.
Talk Button
No Listen Pressing the TALK button at a suite station connects the
Check wiring to terminals 1 and 3, or for short between suite station’s internal speaker to terminals 1 and 2 of
terminals 1 and 2. Check to see if wiring to entrance the PK-543A, which serves as an audio input to the
panel speaker is shorted or open. Suite station can be amplifier. The audio is then amplified and sent to
swap tested with another working unit. terminals A and G, which are connected to the entrance
No Door Operation panel’s speaker (speaker mode).
Check wiring to door release for shorts and opens, or Listen Button
for defective door release. Confirm that shunts are Pressing the LISTEN button at a suite station connects the
properly set for door release type and that connections suite station’s internal speaker to terminals 1 and 3 of
to appropriate output have been made. Check wiring to the PK-543A, which serves as an audio output from the
terminals 2 and 3, or 1 and E (depending upon suite amplifier. This allows the suite station to receive the
station type). amplified audio being received by the amplifier on
No Call Tone terminals A and G from the entrance panel speaker
Check wiring to terminal Z or ZW to entrance panel, (microphone mode).
related entrance panel call buttons, and suite station X Door Button
terminal. Suite station can be swap tested with another Pressing the DOOR button at a suite station creates a
working unit. closure between terminals 2 and 3 on the PK-543A. This
Excessive Hum or Distortion state is sensed by the amplifier and causes the door
Check whether wiring is installed too close to electrical release to be activated (output specifics are based on
wiring or electrical devices; amplifier installed too close PK-543A settings). This state is also triggered by shorting
to transformers or other electrical devices; twisted pair terminals 1 and E as is typically done by a postal lock.
wiring not used as required; or amplifier voice volume
set too high.
Cross Reference Part Index
Radio Interference
Model Numbers Below Are Interchangeable:
Connect G terminal from amplifier to electrical ground.
Note: This connection is not shown on the wiring
PK543 = PK-543 (Old Style)
diagram, since the situation is not always improved by PK-543 = PK543 (Old Style)
adding it. If the problem persists, consult the factory or PK543A = PK-543A (New Style)
service representative. PK-543A = PK543A (New Style)
PS-3A, PS-3B = SS102A (16VAC)
Oscillation (feedback or howling)
PS-30A = SS106 (16VAC)
Reduce the voice volume until oscillation is eliminated.
If oscillation stops when the call tone wire is removed
RY014B = RY-014B
from ZW, set entrance tone (SW3) to the OFF (left) RY-014B = RY014B
position. SS102A = PS-3A, PS-3B
SS106 = PS-30A (Tri-Volt: 8/16/24VAC)

Copyright © Lee Dan Communications,, Inc. All Rights Reserved. IN-826 PK-543A Installation Instructions • Page 3
Figure 1 - PK-543A Wiring Diagram
ENTRY PANEL
(Typical)

IR402 Connections
If shielded wire is used, connect
Blue Wire to 1 shields to orange/black wire (G)
Violet Wire to 2 at amplifier.
DO NOT run these wires
Gray Wire to 3 in the same cable! It will
White -- X (call wire) cause feedback.

16 VAC CONNECT TO
See note #4 Apartment Call Buttons 120 VAC
3 Wire 4 Wire 5 Wire PS-3A, PS-3B
Intercom Intercom Intercom TRANSFORMER
#18 AWG Wire
Station Station Station
(Typical) (Typical) (Typical) 16V AC Doorstrike Configuration
Remove shunt on JP5, set J1
shunt to 2 and 3 and J2 shunt
to 1 and 2. (see other diagrams

Page 4 • IN-826 PK-543A Installation Instructions


for additional configurations)

Tone in
Switched Audio
Audio Common
Tone in
Audio to station
Audio from station
Audio Common
Tone in
5 Wire sta. door release
Audio to station
Audio from station
Audio Common
PK543A Amplifier
X 5 1 X 3 2 1 X E 3 2 1 L- YEL (-) DC Door power
L+ YEL/BLK (+) DC Door power
D BRN Switched AC door release
K RED AC Input (Common)
Twisted Pair
C ORG AC Input
Twisted Pair Twisted Pair P WHT/BLK Strobe (LI404) power (+24VDC)
G ORG/BLK Entry speaker common
A BLK Entry speaker switched audio
E WHT 5 Wire station door release
5 GRN 3 wire station audio
3 GRY Audio to station
2 VIO Audio from station
1 BLU Audio Common
ZW RED/WHT Warble tone out
Z BRN/WHT Tone out
(Optional)
Notes: Twisted Pair

1. Use #22 AWG wire unless shown otherwise.


2. Warble or Steady Tone is hard wire selectable.
3. If entry panel has handset, connect it in place of speaker.
4. 3, 4 and 5 wire intercom station types may be used in any combination, Post Office Lock
with the exception of the IR102C, which can only be used in conjunction Adapter

with other IR102B or C devices.


5. Door release wiring should be run separate from entrance panel speaker wiring.
6. Shunts referred to in diagrams are located on PK543A.
7. Terminal P is for strobe only, do NOT connect other wires to this terminal.
Drawing Name & Number: IL826 PK543A Wiring Rev1 052504 1

Copyright © Lee Dan Communications, Inc. All Rights Reserved.


Figure 2 - PK-543A Doorstrike Applications

+24V AC Doorstrike Application: 16V DC Doorstrike Application:


Remove JP5 Shunt Remove JP5 Shunt
Set J1 shunt to 2 and 3 Set J1 shunt to 2 and 3
#18 AWG Wire
Set J2 shunt to 1 and 2 Set J2 shunt to 1 and 2

#18 AWG Wire Doorstrike


PK-543A Amplifier PK-543A Amplifier
Doorstrike L- YEL (-) DC Door power L- YEL (-) DC Door power
L+ YEL/BLK (+) DC Door power L+ YEL/BLK (+) DC Door power
D BRN Switched AC door release D BRN Switched AC door release
K RED AC Input (Common) K RED AC Input (Common)
C ORG AC Input C ORG AC Input
P WHT/BLK Strobe (LI404) power (+24VDC) P WHT/BLK Strobe (LI404) power (+24VDC)
G ORG/BLK Entry speaker common G ORG/BLK Entry speaker common
A BLK Entry speaker switched audio A BLK Entry speaker switched audio
E WHT 5 Wire station door release E WHT 5 Wire station door release
5 GRN 3 wire station audio 5 GRN 3 wire station audio
3 GRY Audio to station 3 GRY Audio to station
2 VIO Audio from station 2 VIO Audio from station
1 BLU Audio Common 1 BLU Audio Common
ZW RED/WHT Warble tone out ZW RED/WHT Warble tone out
Z BRN/WHT Tone out Z BRN/WHT Tone out

16 VAC Tap

Common
CONNECT TO 16 VAC CONNECT TO
120 VAC 120 VAC
8 VAC Tap

PS-3A, PS-3B PS-3A, PS-3B


TRANSFORMER TRANSFORMER
#18 AWG Wire #18 AWG Wire

Drawing Name & Number: IN-826 PK543A Doorstrike Applications 1 Rev0 050604 1

+12VDC/500mA DC Maglock Application: +24VDC/250mA DC Maglock Application:


Install JP5 Shunt Install JP5 Shunt
Maglock #18 AWG Wire Set J1 shunt to 1 and 2 Set J1 shunt to 2 and 3
Set J2 shunt to 2 and 3 #18 AWG Wire
Set J2 shunt to 2 and 3

Maglock
PK543A Amplifier PK543A Amplifier
L- YEL (-) DC Door power L- YEL (-) DC Door power
L+ YEL/BLK (+) DC Door power L+ YEL/BLK (+) DC Door power
LP D BRN Switched AC door release D BRN Switched AC door release
K RED AC Input (Common) K RED AC Input (Common)
8 C ORG AC Input C ORG AC Input
4 pin header JP3, P WHT/BLK Strobe (LI404) power (+24VDC) P WHT/BLK Strobe (LI404) power (+24VDC)
located in front of G ORG/BLK Entry speaker common G ORG/BLK Entry speaker common
main connector. A BLK Entry speaker switched audio A BLK Entry speaker switched audio
E WHT 5 Wire station door release E WHT 5 Wire station door release
5 GRN 3 wire station audio 5 GRN 3 wire station audio
3 GRY Audio to station 3 GRY Audio to station
2 VIO Audio from station 2 VIO Audio from station
1 BLU Audio Common 1 BLU Audio Common
ZW RED/WHT Warble tone out ZW RED/WHT Warble tone out
Z BRN/WHT Tone out Z BRN/WHT Tone out

16 VAC Tap

Common
CONNECT TO 16 VAC CONNECT TO
120 VAC 120 VAC
8 VAC Tap

PS-30A PS-3A, PS-3B


TRANSFORMER TRANSFORMER
#18 AWG Wire #18 AWG Wire

Note: LP and 8 are each available on two


pins of the JP3 connector. Brackets are
provided to identify.

Drawing Name & Number: IN-826 PK543A Doorstrike Applications 2 Rev1 051606 1

Copyright © Lee Dan Communications,, Inc. All Rights Reserved. IN-826 PK-543A Installation Instructions • Page 5
Figure 3 - PK-543A Shunts and Settings

CONNECTORS
®

LEE DAN®
LP
8
J2 D PK543A POWER PACK
PK-543A POWER PACK
K
C
A
ZW
Z 4 Wire
JP5 LED = POWER
Intercom
JP5 1 2 3 1-2 DOOR STRIKE
J2 2-3 MAGLOCK
1 2 3 1-2 +12V DC OUT
Station
J1 2-3 +24V DC OUT
(Typical)
Power LED L-
DC DOOR

Audio from station


L+ VOICE

Audio to station

Audio Common
D
AC DOOR VOLUME
K
J1 C
TRANSFORMER

Tone in
P +24V

VERIFY ALL CONNECTIONS


G
SPEAKER

BEFORE ATTACHING
A
X 3 2 1
LP & 8 Connector E P.O. LOCK (4)

TRANSFORMER
5

WARNING
3 COMMON
2 WIRES
Main Connector 1
ZW BUZZ 1
Z BUZZ 2
SEE MANUAL FOR DETAILS
PK502B Interface Connector SWITCH FUNCTIONS
1 SHORT DOOR TIME
RY014B
2 MEDIUM DOOR TIME
1 AND 2 OFF = LONG
DOOR TIME
3 ENTRANCE TONE
4 POSTAL TIMER
1 B
5 PK543 COMPATIBLE
6 DOOR HOLD TIMEOUT A
Dipswitch TONE 7 TALK INTERLOCK

VOLUME For PK543 drop-in replacement set:


SW4 OFF, SW5 ON, SW6 ON & SW7 ON
Shunts: JP5 remove, J2 1-2 & J1 2-3
C X

Dipswitch Settings: (right and left are referenced from the view above)
Short Door Time - set SW1 to ON (right) and SW2 to OFF (left), 2 seconds
Medium Door Time - set SW1 to OFF (left) and SW2 to ON (right), 10 seconds
Long Door Time - set SW1 to OFF (left) and SW2 to OFF (left), 25 seconds
Entrance Tone - set SW3 to ON (right) to activate this feature
Postal Timer - set SW4 to ON (right) and SW5 to OFF (left) to make postal control timer independent at 25 seconds
PK543 Compatible - set SW4 to OFF (left) and SW5 to ON (right) to make unit for drop-in replacement for PK543*
Door Hold Time Out - set SW6 to OFF (left) to activate this feature
Talk Interlock - set SW7 to OFF (left) to activate this feature (available for 4-wire stations only)
* - For PK543 Compatible mode, set SW4 OFF, SW5 ON, SW6 ON & SW7 ON.
Also remove JP5 shunt, set J2 to shunt 1 - 2 and set J1 shunt to 2 - 3.

Drawing Name & Number: IN-826 PK543A Shunts and Settings RY-014B Wiring Rev3 051506 1

Page 6 • IN-826 PK-543A Installation Instructions Copyright © Lee Dan Communications, Inc. All Rights Reserved.
Figure 4 - Theory Diagram

Example of internal connections


of 4 Wire Intercom Station
(most common station) ENTRY PANEL
(Typical)

16 VAC CONNECT TO
120 VAC

Talk PS-3A, PS-3B


TRANSFORMER

Door
Listen

Copyright © Lee Dan Communications,, Inc. All Rights Reserved.


16V AC Doorstrike Configuration

Apartment Call Buttons

Tone in
Audio to station
Audio from station
Audio Common
PK543A Amplifier
X 3 2 1
L- YEL (-) DC Door power
L+ YEL/BLK (+) DC Door power
D BRN Switched AC door release
K RED AC Input (Common)
C ORG AC Input
P WHT/BLK Strobe (LI404) power (+24VDC)
G ORG/BLK Entry speaker common
A BLK Entry speaker switched audio
E WHT 5 Wire station door release
5 GRN 3 wire station audio
3 GRY Audio to station
2 VIO Audio from station
1 BLU Audio Common
ZW RED/WHT Warble tone out
Z BRN/WHT Tone out

Post Office Lock


Adapter

Drawing Name & Number: IL826 PK543A Theory Rev0 050704 1

IN-826 PK-543A Installation Instructions • Page 7


Innovations in Communications TM
since 1955 PK-543A
SPECIFICATIONS
APPLICATION ARCHITECTS' AND ENGINEERS'
The PK-543A Power Pack Intercom Amplifier is a self-
contained unit not requiring an external amplifier. The
SPECIFICATIONS
PK-543A is designed for use with most 3-4-5 wire apartment The intercom amplifier shall be a LEE DAN model
stations and provides amplification control and power circuits PK-543A or approved equal and shall provide the amplifi-
needed to operate a complete apartment intercom system. cation, control and power circuits needed to operate the
Voice volume control and tone volume control are easily entire intercom system. Amplifier shall feature integrated
adjustable through the screwdriver slot on the front panel. circuit amplification, integrated circuit tone call oscillator,
adjustable volume and tone volume controls. Amplifier
PK-543A is the most popular and most versatile shall provide for AC or DC door release operation
apartment intercom amplifier selectable by terminal connection and selectable delayed
door timing of 8 seconds or 16 seconds selected at the DIP
Additional functions include multi-entrance operation with the
switch. A steady or warble tone is available to identify
PK-502B, AC or DC door operation selectable by terminal
calling entrance.
connection with selectable delayed action door release set at the
dip switch, post office door lock release and a tone signal to
Low voltage wiring shall be used and plug-in type
call remote stations. A steady or warble tone can be used to
terminals shall be provided for installation wiring.
identify calling from the main entrance panel and a call button
Non plug-in connectors shall not be acceptable.
located at the suite entrance.
The PK-543A shall be mountable to the rear of specifi-
SPECIFICATIONS cally designed LEE DAN apartment entrance speaker
Dimensions: Height: 5 1/2" Width: 3 1/8" Depth: 2" panels.
Construction: Rugged ABS Plastic Casing.
STATION COMPATIBILITY:
Amplification: Integrated circuit amplifier including
amplifier with frequency response adjusted PK-543A is compatible with these LEE DAN
for best voice articulation. apartment intercom stations:

Call Tone: Integrated circuit oscillator. IR-081B, IR-081C, IR-081D

Door Release: AC or DC operation with selectable timing. IR-082A, IR-082C, IR-082D

IR-103B, IR-103E, IR-104B, IR-104E, IR-105B, IR-105E


P.O. Release: P.O. door lock release.
IR-107A, IR-107AG, IR-107C, IR-107CG, IR-107D, IR-107DG, IR-147A
Connections: Polarized plug in type.
IR-203, IR-203E, IR-204, IR-204E, IR-205, IR-205E
Power Req.: 16 VAC, 10VA
IR-207, IR-207A, IR-207B, IR-207S, IR-207SS
Mounting: Surface, or mount to the rear of specifically
IR-307, IR-307A, IR-307C, IR-307D
designed apartment entrance speaker panels.
IR-403, IR-404, IR-405, IR-413, IR-414, IR-415
Replaces: LEE DAN® models: PK-543, PK-104B,
PK-103B, PK-103A, PK-101A. Also replaces IR-423, IR-424, IR-425, IR-433, IR-434, IR-435

many other brands and models (call for info). IR-443, IR-443SS, IR-444, IR-444SS, IR-445, IR-445SS

IR-453, IR-454, IR-455

IR-463, IR-463SS, IR-464, IR-464SS, IR-465, IR-465SS

PK-543A compatible stations can often, but not always be intermixed


within a system. Contact factory to verify compatibility.

800-231-1414 • 631-231-1414 INTERCOMS • MAILBOXES • DIRECTORIES


155 Adams Avenue • Hauppauge, NY 11788-3699 ANNUNCIATORS • WIRE & CABLE • NURSE-CALL
Fax 631-231-1498 • www.LEEDAN.com With continuous product improvement, specifications are subject to change without notice.

Page 8 • IN-826 PK-543A Installation Instructions Copyright © Lee Dan Communications, Inc. All Rights Reserved.