p-p-3 Gobel! igh Qtcoar ass QATAR METALS COATING COMPANY wi Date: 01 November 2020 TLC20007571 Application Number aI Qatar Metals Coating Company Name of Project Ea ptall al Messaied Industrial 7 Location| hudll | Qatar Steel - Owner aia 04/10/2020 1" Inspection Date _J3! isall & 3 Compliance Comment Aled Spall go GLA Passive Fire Safety System Complying (As per attached) Our application for CDD drawing under PS. No. 1N/2020/0004936 already approved on 19/10/2020 Ztball Mile} ase G Exit Access must not be obstructed with furniture, decorations, Egress to be continually maintained free of obstructions. As per attached letter from M/s. Tyco. vabyl aaksl 2 Firefighting [Systems gh ge gall laa Cy pal | ps Mall JUG 3 I gay Gaal dae a. Sequence of operation test was discontinued. due to the spillage of water in the fire pump room.(i.e. Diesel fire pump) t b. Ithas been noted that there is trouble in electric fire pump panel. ©. Diesel Fire pump shall be provided of Pump lockout Complying, ‘. Calibration Certificate for all Pressure gauge installed in fire Pump room shall be submitted. Complying Coverage of testing during inspection is the existing firefighting system on the site , 4 Basin GUS all Coes oly! ali OS i oS Gl Gay _ gules pital! glial NEPA 16, NFPA 14, NFPA 13, NEPA20NFPA2001, NFPA24, NFPA22, NFPA20. coitall Ba yo gall Glau aulal 58 Zale ase | a. Fire house reel cabinet shall be accessible at all times and shall not be obstructed. Complying Basil Quail GULL Cae Gad ae OS Fay » Call GsNFPA.29Slly Stall Fire Pump shall be installed accordance to CDD approved drawing and NEPA. Complying APMAEll Gye ASL y jy pall Adee Zils Ga] oh gall GLE 5Y Loli allS y jasc y a. Conduct maintenance on the fire pump packing glands to ensure proper tightness and adequate lubrication to avoid overheating. nie sal te G15 AAI Lay 58 845 ns Fire water tank shall be provided with the following: DALE ALE see Bale Ga & ginenny Blull os ghae Lulibe | a Visual water level indicator shall be made of non- combustible materials. OF BAM pp iy Y tay AAS; eda y dy) ja) das pre Garg 100 b Marking of effective tank capacity in lettering of a minimum height of 100 mm. NEPA 30,NFPA 20 Gus J jaall GUI 58 aS 3 Gay Diesel fuel tanks shall be installed in accordance with NFPA 20 and NFPA 30. 10 258 aun Ay gall jy yall GU as jsp HS By NEPA Type and rating of Portable fire extinguishers shall be installed as per NFPA10. E29 ie Still ae Sp yall Lie Gye lane aang Gin | Vgall Spang ABS) ee Ul actual GSLY (98 LUI Aye a Portable fire extinguisher shall be place in appropriate and accessible, All portable fire extinguishers found with down pressure must be maintain, As per attached letter from M/s. Tyco. existing fire Alarm system on the site. N lad jeanill aie IY) gL td Testing of fire Alarm system FAILED due to the following:- Saillda.g) gd cUbdl aga -1 a_FACP has (Faults- Troubles... etc.) b Beam Detector not available for testing during inspection. SIS) abil So Fire Detection & Alarm Systems - Coverage of testing during inspection is the | 7 Complying (bide) CUES Gas ISI pli Gaady GS NFPA 72 jxless gia € Installation and testing of system shall be in accordance with CDD approved drawing and NFPA 72. Zeal USA IDY) Sigal gues Cut a a All fire alarm equipment shall be fixed and mounted.(e.g. Beam Detector check and rectify.) elpal /SSLE YI GS / g Jaa al YT GLO gl sb Exit/Directional Signs/Emergency Lights __ (Markings 5 i Bane y Apne (¢ p52) Lk @ 9 8 OS uy By NFPA 101 23S! Ud «ginal! ¢ Udall hd Every exit door shall be provided with illuminated CDD approved “EXIT” sign, in accordance with NEPA 101. a Ui Ab (ye Bacieall 5 4) gall el pec Guests y Cust Gay Cay cplaall glial is (ye Baie! SUabs all iy gisall Complying NFPA 101 35S CDD approved emergency lights shall be installed | and operated in accordance with and CDD | approved drawing and NFPA 101. shall ol glad SAGE W lagi 99 AR y cabal Documents/Certifieations to be Submitted in the System phat g Laat oS gisy 5 cpital EUAN dain ib ye Bina 9 Ul aga Cy GI Ga) Reports shall be prepared by CDD certified contractor duly signed and stamped by consultant) a_Emergency ight must be maintained WENN gle Oye Ga age Gand 9 pa Sle Re-submit/upload in the system with the appropriate data for the maintenance reports of the following listed below done by contractor, it shall be signed/stamped. ‘As per attached the report ‘@Summary form — Inspection, Testing & Maintenance ‘As per attached the report be ire pump. As per attached the report c- Fire Detection Alarm System. ‘As per attached the report & Standpipe and House System. ‘As per attached the report © Portable fire Extinguisher ‘AS per attached the report F Emergency Lighting, As per attached the report g- The Emergency Plan & Program(Emergency Response Procedure Manual) Regarding fire evacuation procedures, reporting system, staff guest/occupant to emergencies, assembly area, etc ‘As per attached the report h, Latest fire safety certificate from Civil Defiance Department. Prepared By Prepared By w =f Sood Alam Environmental Supervisor Plant Supervisor ~ Hussein Mohammed Abdallah Abo Zaid Approved By Manager

You might also like