FM 352 CAM CONTROLLER

Function

 32 cam tracks:
13 leading directly to onboard digital outputs
 Configurable number of cams:
Depending on programming 32, 64 or 128 cams are available.
 Configurable cam characteristics:
Cams can be defined as position-based cams or time-based cams. They can be programmed direction-dependent
(up/down).
 Parameterizable assignment of cams to digital outputs:
Track outputs 0 and 1 can be parameterized as counter cam tracks and track output 2 can be parameterized as a
brake cam track.

Special functions

 Longitudinal measuring
 Set reference point
 Set actual value
 Set actual value on-the-fly
 Zero offset
 Change cam edges
 Simulation mode

Page 1183 Mar 2008 Siemens ITS


Mode of operation

The ultra-high-speed FM 352 electronic cam controller uses a sensor to detect axis positions and then triggers control
commands by setting onboard outputs.

After the transfer of machine and cam data, the FM 352 works autonomously. Only control and checkback signals are
then exchanged between the CPU and the FM 352.

The electronic cam controller works particularly fast:

 13 digital outputs for cam tracks:


For rapid transmission of control signals to the process
 Speed-dependent dynamic shifting for each cam:
For automatic compensation of the dead time of the actuator connected at the time
 The machinery to be controlled can be connected directly to the module. Control relays are only required for
actuators with high current consumption.

Technical specifications
Page 1184 Mar 2008 Siemens ITS
Technical specifications

6ES7 352-1AH02-0AE0
Supply voltage
24 V DC Yes
Input current
from load voltage L+ (without load), max. 200 mA
from backplane bus 5 V DC, max. 100 mA
Encoder supply
5 VPage
encoder
1185 supply Mar 2008 Siemens ITS
•5 V Yes
•Output current, max. 300 mA
•Cable length, max. 32 m
24 V encoder supply
•24 V Yes
•Output current, max. 300 mA
•Cable length, max. 100 m
Digital inputs
Number/binary inputs 4
Functions Reference point switch, set floating actual
value/length measurement, brake release,
enable track output no. 3
Input voltage
•Rated value, DC 24 V
•for signal "0" -30 to +5 V
•for signal "1" 11 to 30 V
Input current
•for 2-wire BERO
2 mA
• for signal "0", typ.
7 mA
• for signal "1", typ.
Digital outputs
Number/binary
Page 1186 outputs 13
Mar 2008 Siemens ITS
Functions Cam track
Functionality/short-circuit strength Yes
Output voltage
•Rated value (DC) 24 V
•for signal "1", min. UP - 0.8 V
Output current
•for signal "1" permissible range for 0 to 60 5 mA; with UPmax
°C, min.
•for signal "1" permissible range for 0 to 60 600 mA; with UPmax
°C, max.
•for signal "0" residual current, max. 0.5 mA
Encoder
Connectable encoders
•Incremental encoder (symmetrical) Yes
•Incremental encoder (asymmetrical) Yes
•Absolute encoder (SSI) Yes
•2-wire BEROS Yes
2 mA
• permissible quiescent current (2-wire
BEROS), max.
Encoder signals, incremental encoder
(symmetrical)
•Trace mark signals A, notA, B, notB
•Zero mark
Page 1187signal N, notN
Mar 2008 Siemens ITS
•Input signal 5 V difference signal (phys. RS 422)
•Input frequency, max. 1 MHz
Encoder signals, incremental encoder
(asymmetrical)
•Trace mark signals A, B
•Zero mark signal N
•Input voltage 24 V
•Input frequency, max. 50 kHz; 50 kHz for 25 m cable length; 25
kHz for 100 m cable length
Encoder signals, absolute encoder (SSI)
•Data signal DATA, notDATA
•Clock signal CL, notCL
•Telegram length 13 or 25 bit
•Clock frequency, max. 1 MHz
•Gray code 1
•Cable length, shielded, max. 320 m; at max. 125 kHz
Galvanic isolation
Galvanic isolation digital inputs
•Galvanic isolation digital inputs No
Galvanic isolation digital outputs
•Galvanic isolation digital outputs No
Connection method
required front connector 1x 20-pin
Dimensions
Page 1188 Mar 2008 Siemens ITS