EDTS041 REV.-B
Specification for Battery Charging Unit, 200A, 130Volt for Self Generation
Air Conditioned Coaches
1.0 SCOPE
1.1 This specification covers the design, manufacturing and supply of battery
charging unit required for fitment on under frame of self generating ait-
conditioned coaches for charging a battery bank consisting of 56 cells of 1100
Ah capacity VRLA batteries while the coach is stationery, receiving the power
from the external soutce of supply of 3- phase 415 volts, 50HZ.
4.2. This specification i.e. EDTS041 Rev.-B has been made inline with the earlier
spec. no. EDTS041 Rev.-A incorporating the ICF amendments -1 & 2 and
modifications mentioned in note no. MD/DSS/SPEC/211 Dated 11.09.2001
2.0 : SERVICE CONDITIONS
The equipment shall be sturdy &suitable for the following service condition
normally to be met in the service:
2.1: Environmental Conditions:
~Ambient 6 to 455°C
-Humidit _ upto 08% during rainy season
Wtitude [max 1000 meter above sealevel |
2.2. Working conditions:
= Train Speed - 460kmph
[= Vibration and Shocks
i) Maximum vertical acceleration 3.09
i) Maximum lateral acceleration . 13.09
ii) Maximum longitudinal acceleration ~ 3.09
iv) Frequency & amplitude:-
Sinusoidal form of vibration, the frequency ‘f lies between 1 Hz and 100 Hz and their
amplitude ‘a’ expressed in "mm’ is given as a function of 'f by the equation:
hoon
EDTS 047 fe ~faa08.1s [Me
Se |
DYCEE/D&D | Page 1 of 19
(SPEC.NO|Rev - | Date ‘SSE/CAD | SEE/O&D
| - —