Catalog
Load-independent
Proportional valve
type PVG 32
SAE version
With mechanical actuation
With electrical remote control and mechanical actuation
e r d i d r r P P
i
ow. Flu . Flu owe owe luid Fluid w
r r P P . F . P o
e we uid luid er er id i d
Po . Fl r . F Pow Pow. Flu . Flu
e r e id i d r e r P
w o w l u
o P . F . F ow o Flu Fl l u e w i d
i d r r P P . .
u we we uid luid er er id
o
P id r . P o F l . F o w o w l u
e r P d P . F
l u e w i d i r e r
F ow Po Flu . Flu we ow l
d P i d . r P o P . F
r
ui . Flu we owe luid luid er we
r d Po id P r . F r . F Pow Po .
l u i l u e w e id uid er
F . F Pow Po Flu Fl ow o
r d P P Book 8 Partion 2 HK.57.B1.22
BACK
Contents
Contents Page
Conversion factors 2
General 3
Function 4
PVG 32 valve group 4
Plug for external pilot oil supply, PVPC 6
Friction detent, PVMR 6
Mechanical float position lock, PVMF 6
PVBS main spools for flow or pressure control 7
Electrical LS unloading valve, PVPX 7
Technical data 8
Electrical actuation 10
Technical characteristics 23
Dimensions 29
Hydraulic systems 31
Electrical systems 32
System safety 33
Order specification 40
2 HK.57.B1.22
BACK
General
HK.57.B1.22 3
BACK
Function
PVG 32 valve group with open When the pump is started and the main spools in The basic module can be supplied without the load
centre PVP the individual basic modules (11) are in the neutral drop check valve in channel P for functions with
(PVB with flow control spool) position, oil flows from the pump, through over-centre valves.
connection P, across the pressure adjustment
spool (6) to tank. The oil flow led across the The shock valves PVLP (13) with a fixed setting and
pressure adjustment spool determines the pump the suction valves PVLA (17) on ports A and B are
pressure (stand-by pressure). used for the protection of the individual working
function against overload and/or cavitation.
When one or more of the main spools are actuated,
the highest load pressure is fed through the shuttle An adjustable LS pressure limiting valve (12) can be
valve circuit (10) to the spring chamber behind the built into the A and B ports of pressure-
pressure adjustment spool (6), and completely or compensated basic modules to limit the pressure
partially closes the connection to tank. from the individual working functions.
Pump pressure is applied to the right-hand side of The LS pressure limiting valves save energy
the pressure adjustment spool (6). The pressure compared with the shock valves PVLP:
relief valve (1) will open should the load pressure - With PVLP all the oil flow to the working function
exceed the set value, diverting pump flow back to will be led across the combined shock and suction
tank. valves to tank if the pressure exceeds the fixed
setting.
In a pressure-compensated basic module the - With LS pressure limiting valves an oil flow of
compensator (14) maintains a constant pressure about 0.5 gpm (2.0 l/min) will be led across the LS
drop across the main spool - both when the load pressure limiting valve to tank if the pressure
changes and when a module with a higher load exceeds the valve setting.
pressure is actuated.
PVG 32 valve group with In the closed centre version an orifice (5) and a plug When a main spool is activated the pump regulator
closed centre PVP (7) have been fitted instead of the plug (4). This will adjust the displacement so that the set
(PVB with flow control spool) means that the pressure adjustment spool (6) will differential pressure between P and LS is
only open to tank when the pressure in channel P maintained.
exceeds the set value of the pressure relief
valve (1). The pressure relief valve (1) in PVP should be set at
a pressure of approx. 435 psi (30 bar) above maxi-
In load sensing systems the load pressure is led to mum system pressure (set on the pump or external
the pump regulator via the LS connection (8). pressure relief valve).
4 HK.57.B1.22
BACK
Function
PVP
PVB
PVB
HK.57.B1.22 5
BACK
Please note:
With closed centre PVP the external
pilot oil supply can be connected to
the pressure gauge connection
without the use of a PVPC plug.
Please note:
PVMR should only be used
together with PVB basic modules
with pressure compensator.
6 HK.57.B1.22
BACK
Function PVBS
PVBS main spools for flow When using standard flow control spools, the pump In this way the pump pressure will always
control (standard) pressure is determined by the highest load correspond to the load pressure plus the stand-by
pressure. This is done either via the pressure pressure of the pressure adjustment spool or the
adjustment spool in open centre PVP (fixed pump regulator.
displacement pumps) or via the pump regulator This will normally give optimum and stable
(variable displacement pumps). adjustment of the oil flow.
PVBS main spools for flow PVBS main spools with linear characteristic have The interaction between the small dead band of the
control (with linear less dead band than standard spools and a spools and the hysteresis of the PVEM actuator of
characteristic) completely proportional ratio between control signal 20% involves a risk of building up a LS pressure in
and oil flow in the range beyond the dead band. neutral position.
PVBS with linear characteristic must never be used
together with PVEM electrical actuators
PVBS main spools for In a few systems load sensing pump pressure may
pressure control result in unstable adjustment of the oil flow and a
tendency towards system hunting. This may be the
case with working functions that have a large
moment of inertia or overcenter valves.
In such systems Danfoss PVBS main spools for
pressure control can be advantageous.
The use of pressure control spools, however, also Due to these factors it is recommended that
means that pressure control spools are only used when it is
- the oil flow is load dependent known for certain that problems with stability will
- the dead band is load dependent arise - or already have arisen.
- the pump pressure can exceed the load
pressure by more than is usual.
PVPX is a solenoid LS unloading valve. PVPX is • For a PVP pump side module in closed centre
fitted into the pump side module enabling a version the relief to tank of the LS signal means
connection to be made between the LS and the tank that the pressure is reduced to the sum of the
lines. Thus the LS signal can be relieved to tank by tank port pressure for the pump side module plus
means of an electric signal. the stand-by pressure of the pump.
HK.57.B1.22 7
BACK
Technical data
Technical data The technical data for PVG 32 and PVPX are typical
measured results. For the hydraulic system a mineral
based hydraulic oil with a viscosity of 102 SSU
(21 mm2/s) and a temperature of 122°F (50°C) was used.
Max. internal leakage A/B → T, without shock valve 1.85 in3/min (20 cm3/min)
at 2175 psi (100 bar) and 102 SSU (21 mm2/s) A/B → T, with shock valve 2.15 in3/min (25 cm3/min)
Recommended temperature 86-140°F (30 - 60°C)
Oil temperature (inlet temperature) Min. temperature -22°F (-30°C)
Max. temperature +194°F (90°C)
Ambient temperature -22 to +140°F (30 to 60°C)
Operating range 65 to 347 SSU (12 to 75 mm2/s)
Oil viscosity Min. viscosity 39 SSU (4 mm2/s)
Max. viscosity 2128 SSU (460 mm2/s)
Oil consumption in pilot oil pressure reduction valve 0.25 gpm (1 l/min)
1) Max. 10% operation every minute
2) With PVSI end plate
3) For 130 l/min contact technical Sales Organization for Danfoss Hydraulics
4) In open circuit systems with short P-hoses/tubes, attention should be paid to pressure peaks at flows > 26.4 gpm (100l/min).
8 HK.57.B1.22
BACK
HK.57.B1.22 9
BACK
Electrical actuation
• Compact
• Robust operation
• Simple build-up
Proportional actuation With electrical proportional actuation the main spool (feed-back signal). This signal is registered by the
position is adjusted so it corresponds to an electrical electronics.
signal - from a remote control unit, for example. The variation between the set-point signal and
feed-back signal actuates the solenoid valves.
The signal (set-point signal) is converted into a The solenoid valves are actuated so that hydraulic
hydraulic pressure which moves the main spool. pressure moves the main spool into the correct
The position of the main spool is converted in the position.
positional transducer (C) to an electric signal
• ON-OFF modulated
• Inductive transducer
• Medium hysteresis
10 HK.57.B1.22
BACK
The fault monitoring system A fault monitoring system is provided in all PVEH Passive fault monitoring:
and PVES models. The system is available in two - A delay of 250 ms before anything happens.
versions: – The active fault monitoring type, which - An alarm signal is sent out through the connector.
provides a warning signal and deactivates the - This state is not memorized. When the erroneous
Note: solenoid valves, and the passive fault monitoring state disappears, the alarm signal will turn to pas-
1. Different degrees of safety are type, which provides a warning signal only. See sive again. However, the signal will always be
described on pages 33 to 35. figure below. active for a minimum of 100 ms when triggered.
Both active and passive fault monitoring systems
2. The fault monitoring does not are triggered by three main events: To prevent the electronics from going into an
work if the supply voltage to undefined state, a general supervision of the power
PVEH/PVES is cut off - for Input signal monitoring: supply and the internal clock frequency is made.
example by a neutral position
The input signal voltage is continuously monitored. This function applies to PVEH, PVES and PVEM:
switch (see page 34).
The permissible range is between 15% and 85% of
3. When using PVEH/PVES with the supply voltage. Outside this range the section High supply voltage:
passive fault monitoring it’s up will switch into an active error state. The solenoid valves are disabled when the supply
to the customer to decide on voltage is exceeded by 50% (18 V for a 12 V PVE
the required degree of safety Transducer supervision: and 36 V for a 24 V PVE).
for the system (see page 33). If one of the wires to the LVDT sensor is broken or
short-circuited, this section will switch into an active Low supply voltage:
error state. The solenoid valves are disabled when the supply
voltage falls below 8 V.
Supervision of the closed loop:
The actual position must always correspond to the Internal clock:
demanded position (input signal). When the The solenoid valves are disabled when the internal
distance from neutral to the actual position is longer clock frequency fails.
than the demanded distance, the system detects an All three states are triggered automatically when the
error and will switch into an active error state. On fault conditions cease.
the other hand, a situation where the actual position
is closer to neutral than that demanded will not
cause an error state. This situation is considered “in
control”.
When an active error state occurs, the fault
monitoring logic will be triggered:
Note:
The neutral deadband prevents the output signal
from releasing the fault monitoring logic, thus
stopping the function until the required pilot oil pres-
sure has been developed.
Active fault monitoring:
- A delay of 500 ms before anything happens.
- The solenoid valve bridge will be disabled, - all
solenoids will be released.
- An alarm signal is sent out through the connector.
- This state is memorized and continues until the
system is actively reset (by turning off the supply
voltage).
HK.57.B1.22 11
BACK
PVEH/PVES - connection to Normal operation (the lamp lights up green) Fault cutout (the lamp light up red)
fault monitoring output
Transistor output Transistor output
function function
Via an external relay the pin pos. 3 can be Other connections possible:
connected to a solenoid valve which will relieve - a solenoid valve to relieve the pump oil flow
the LS-signal to tank, e.g. PVPX. - a signal lamp, an alarm horn
- pump cut-out, etc.
12 HK.57.B1.22
BACK
157B5210 157B5310
With pilot oil supply for electrically
actuated valves.
157B5211 157B5311
With pilot oil supply for electrically
actuated valves.
Connections: P = 7/8 inch - 14; 0.65 in deep or 1 1/16 inch - 12; 0.75 in deep. LS/M = 1/2 inch - 20; 0.47 in deep. T = 1 1/16 inch - 12; 0.75 in deep.
HK.57.B1.22 13
BACK
14 HK.57.B1.22
BACK
Modules and code numbers PVB, PVM, PVMD, PVH, PVMR, PVMF
Connection: Port A/B: 7/8 inch- 14; 0.65 in deep. LSA/B: 1/2 inch-20; 0.47 in deep
HK.57.B1.22 15
BACK
Suction valve
157B2001
port A and/or B.
16 HK.57.B1.22
BACK
PVS
Without active elements. 157B2020
No connections
PVS
Without active elements. 157B2021
Max. intermittent LX pressure: 3620 psi (250 bar)
PVSI
Without active elements. 157B2004
Without connections
PVSI
Without active elements. 157B2005
LX connections. Max. int. LX pressure: 4640 psi (320 bar)
Normally closed:
LS pressure relieved with signal to PVPX. 157B4246 157B4248
HK.57.B1.22 17
BACK
4-way, 3-position.
Closed neutral position. 157B9000 157B9001 157B9002 157B9003 157B9004
Flow control.
4-way, 3-position.
Throttled, open neutral position. 157B9100 157B9101 157B9102 157B9103 157B9104
Flow control.
4-way, 3-position.
Closed neutral position. 157B9010 157B9011 157B9012
Pressure control (PC→ A and B).
4-way, 3 position.
Closed neutral position. 157B9025 157B9020 157B9021 157B9022 157B9023 157B9024
Flow control
4-way, 3 position.
Throttled, open neutral position. 157B9125 157B9120 157B9121 157B9122 157B9123 157B9124
Flow control
18 HK.57.B1.22
BACK
4-way, 3-position.
Closed neutral 157B7005 157B7000 157B7001 157B7002 157B7003 157B7004 157B7006
position.
4-way, 3-position.
Throttled, open 157B7105 157B7100 157B7101 157B7102 157B7103 157B7104 157B7106
neutral position.
3-way, 3-position.
Closed neutral 157B7200 157B7201 157B7202 157B7203 157B7204
position. P → A.
3-way, 3-position.
Closed neutral 157B7301 157B7302 157B7303 157B7304
position. P → B.
4-way, 3-position.
A→T 157B7401 157B7402 157B7403 157B7404 157B7406
in neutral position.
4-way, 3 position.
B→T 157B7501 157B7502 157B7503 157B7504
neutral position
4-way, 3-position.
Closed neutral 157B7025 157B7020 157B7021 157B7022 157B7023 157B7024 157B7026
position.
4-way, 3-position.
Throttled, open 157B7125 157B7120 157B7121 157B7122 157B7123 157B7124 157B7126
neutral position.
4-way, 3-position.
A→T 157B7421 157B7422 157B7423 157B7424
in neutral position.
4-way, 3-position.
B→T 157B7521 157B7522 157B7523 157B7524
in neutral position.
4-way, 4-position.
For float position 157B7620 157B7621 157B7622 157B7623 157B7624
P → B → F.
HK.57.B1.22 19
BACK
Code number
Symbol ISO-symbol Description Size and pressure-compensated oil flow gpm (l/min)
AA A B C D E
1.3 (5) 2.6 (10) 6.6 (25) 10.6 (40) 17.2 (65) 26.4 (100)
4-way, 3 position.
Closed neutral position. 157B7015 157B7010 157B7011 157B7012 157B7013
PC →A and B
4-way, 3 position.
Open neutral position. 157B7115 157B7110 157B7111 157B7112 157B7113
PC → A and B
4-way, 3 position.
Closed neutral position. 157B7040 157B7041 157B7042 157B7043 157B7044
PC →A
4-way, 3 position.
Closed neutral position. 157B7051 157B7052 157B7053 157B7054
PC → B
4-way, 3 position.
Throttled, open neutral position. 157B7141 157B7142 157B7143 157B7144
PC →A
4-way, 3 position.
Throttled, open neutral position. 157B7150 157B7151 157B7152 157B7153 157B7154
PC → B
4-way, 3 position.
A→T 157B7452 157B7453
PC → B
4-way, 3 position
B →T neutral position. 157B7541 157B7542 157B7543
PC → A
PC = Pressure control
4-way, 3 position.
Closed neutral position. 157B7071 157B7072 157B7073 157B7074
PC → B
4-way, 3 position.
Throttled, open neutral position. 157B7161 157B7162 157B7163 157B7164
PC → A
4-way 3 position.
open neutral position. 157B7171 157B7172 157B7173 157B7174
PC → B
4-way, 3 position.
A → T neutral position. 157B7472 157B7473
PC → B
4-way, 3 position.
B → T neutral position. 157B7562 157B7563
PC → A
PC = Pressure control
20 HK.57.B1.22
BACK
4-way, 3 position.
157B9700 157B9701 157B9702 157B9703 157B9704
Closed neutral position.
4-way, 3 position.
157B9710 157B9711 157B9712 157B9713 157B9714
Throttled, open neutral position.
4-way, 3 position.
157B9720 157B9721 157B9722 157B9723 157B9724
Closed neutral position.
4-way, 3 position.
157B9730 157B9731 157B9732 157B9733 157B9734
Throttled, open neutral position.
4-way, 4 position.
Closed neutral position. 157B9825 157B9820 157B9821 157B9822 157B9823 157B9824
P→A→F
4-way, 4 position.
Closed neutral position. 157B9621 157B9622 157B9623 157B9624
P→B→F
HK.57.B1.22 21
BACK
4-way, 3 position.
Throttled, open neutral position. 157B9760 157B9761 157B9762 157B9763 157B9764
4-way, 3-position.
A→T 157B9794
In neutral position.
4-way, 3-position.
B→T 157B9804
In neutral position.
4-way, 3 position.
Closed neutral position. 157B9771 157B9772 157B9773 157B9774
4-way, 3 position.
Throttled, open neutral position. 157B9781 157B9782 157B9783 157B9784
22 HK.57.B1.22
BACK
Technical characteristics
General The characteristics in this catalogue are typical During measuring a mineral based hydraulic oil with
measured results. a viscosity of 102 SSU (21 mm2/s)and a temperatu-
re of 122°F (50°C) was used.
Pressure relief valve characteristic in PVP Neutral flow pressure in PVP, open centre
The pressure relief valve is set at an oil flow of 4,0 gpm (15 l/min). Setting range: 435 to 4350 psi (30 to 300 bar) (4640 psi (320 bar) with PVSI end plate).
US = Signal voltage
UDC = Supply voltage
1 = First PVB after PVP
8 = Eigth PVB after PVP
HK.57.B1.22 23
BACK
US = Signal voltage
UDC = Supply voltage
1 = First PVB after PVP
8 = Eighth PVB after PVP
24 HK.57.B1.22
BACK
The oil flow is dependent on the supplied oil flow, QP. The characteristics The pressure drop of any oil flowing back to tank (QP - QA/B) is read on the
apply for an oil flow of 34.3 gpm (130 l/min) at the actuation of one basic curve for neutral flow pressure in PVP, page 23.
module. If several basic modules are activated at the same time, the
characteristic depends on the load pressure of the activated basic modules.
Set pressure difference between pump pressure and LS signal = 145 psi (10 bar) Set pressure difference between pump pressure and LS signal = 290 psi (20 bar)
The oil flow is dependent on the pressure difference between the pump pressure and the LS signal. Normally the pressure difference is set at the LS pump
regulator.
HK.57.B1.22 25
BACK
Pressure drop PVB at max. Pressure drop PVB for open spool
main spool travel in neutral position
The shock valve PVLP is designed to absorb shock If the working function requires the use of a
effects. So it should not be used as a pressure relief pressure relief valve, a PVB basic module with built-
valve. in LSA/B pressure limiting valve should be used.
26 HK.57.B1.22
BACK
Size A: Size B:
Size C: Size D:
Examples of how to use the Example of determining the oil flow Example of determining spool size
characteristics for pressure • Given: • Given:
control spools - Spool type B - Max. oil flow, QA/B : 23.8 gpm (90 l/min)
- Pressure setting PP : 2320 psi (160 bar) - Pressure setting PP : 2175 psi (150 bar)
- Load pressure, LSA/B : 1450 psi (100 bar) - Load pressure, PLSA : 1810 psi (125 bar)
• Result: • Result:
- Oil flow = 19.8 gpm (75 l/min)(see arrow 1 above) - D spool (see arrow 2 above)
Please note:
Normally a smaller spool can be chosen at pressure It is our experience that the spool can be one size
control. smaller than at normal flow control.
HK.57.B1.22 27
BACK
Characteristics for float Characteristics; oil flow, spool travel and voltage
position main spools
28 HK.57.B1.22
BACK
Dimensions
PVB 1 2 3 4 5 6 7 8 9 10
L1 inch 3.23 5.12 7.01 8.90 10.79 12.68 14.57 16.46 18.35 20.24
L1 mm 82 130 178 226 274 322 370 418 466 514
L2 inch 5.51 7.44 9.37 11.30 13.23 15.16 17.09 19.02 20.95 22.87
L2 mm 140 189 238 287 336 385 434 483 532 581
HK.57.B1.22 29
BACK
Dimensions
30 HK.57.B1.22
BACK
Hydraulics systems
C: Over-centre valve
Electrically actuated PVG 32 - variable displacement pump (electrical actuator, shock valves, etc.)
HK.57.B1.22 31
BACK
Electrical systems
Electrical connections, The electrical connections to remote control levers, Voltage supply
general PVE actuators and voltage supply are made using For a mains transformer with stabilised output
an ordinary terminal strip. voltage, the ripple must not exceed 5% of rated
The wiring diagrams below and on pages 33 to 35 voltage.
shows only the basic outlines for the electrical
connection
Signal leads
Supply leads
F: Signal output,
fault monitoring
E: Emergency stop
32 HK.57.B1.22
BACK
System safety
Building in safety All makes and all types of directional control valves To determine the degree of protection that ought to
(incl. proportional valves) can fail. Thus the neces- be built into the system, Danfoss makes the
sary protection against the serious consequences of following distinctions.
function failure should always be built in.
1. Maximum safety demands
For each application an assessment should be 2. High safety demands
made of the consequences of pressure failure and 3. Average safety demands
uncontrolled or blocked movements. 4. Limited safety demands.
1.
Maximum safety demands
When the fault monitoring system in PVEH is Thus all functions are without operating pressure,
connected, the reaction to electrical and mechanical i.e. locked in position, because there is no pilot
faults (e.g. a spool seizure) is fast and operator- pressure on the pilot operated check valve (C).
independent.
See page 11 “fault monitoring”. Actuation of the emergency switch (E) cuts off
current to the proportional valve and the solenoid
A system can be protected against many electrical, valve (M). Actuation in this case is manual, but the
hydraulic and mechanical faults by building in result is the same as above.
components as shown in the diagram:
R: Alarm logic EHA (or relay) connected to the fault Stopping or disconnecting the pump drive motor is
monitoring system in PVEH another safety measure, if the system reaction time
E: Electrical emergency stop can be accepted.
M: Solenoid valve
C: Pilot-operated check valve Note:
The neutral position switch in the remote control
The alarm logic EHA cuts off current to the solenoid units should not be used.
valve (M) when PVEH monitoring registers a fault.
The solenoid valve then leads the oil flow direct PVEH with fault monitoring must have a constant
from pump to tank. voltage supply.
HK.57.B1.22 33
BACK
System safety
2.
High safety demands
The difference between this safety method and the The method still gives a high degree of protection,
one previously described (1) is that here there is no but requires operator intervention. It is
built-in automatic fault monitoring and a neutral recommended that the neutral position switch be
position switch (N) is connected. always connected to the electrical system. This then
automatically cuts off current to the proportional
valve when the remote control unit is in neutral
position.
34 HK.57.B1.22
BACK
System safety
3.
Average safety demands
The difference in this method is that the LS signal (system dependent), i.e. all functions requiring a
from the proportional valve is led direct to tank when higher operating pressure will not operate.
the emergency switch (E) is activated. This can be
achieved by using the Danfoss LS unloading valve The method can also be used in LS systems with a
PVPX, integrated in the pump side module. variable displacement pump and closed centre
version proportional valve.
In a system with open centre PVP and a fixed The pressure after LS relief then depends on the
displacement pump, the effect is an almost pump stand-by pressure.
pressureless system, 120 - 200 psi (8 -14 bar)
4.
Limited safety demands
The safety system can consist of an emergency requirement. Here, there is no protection against
switch (E) and a neutral position switch (N) if hydraulic and mechanical faults (spool seizured in
protection against electrical failure is the only an extreme position).
HK.57.B1.22 35
BACK
Oil The main duty of the oil in a hydraulic system is to Biodegradable oils
transfer energy; but it must also lubricate the Danfoss PVG 32 valves can be used in systems
moving parts in hydraulic components, protect them with rape-seed oil. The use of rape-seed oil is
against corrosion, and transport dirt particles and conditioned by
heat out of the system. - complying with the demands on viscosity, water
It is therefore important to choose the correct oil content, temperature and filtering etc. (see
with the correct additives. This gives problem-free chapters below and technical data page 9).
operation and long working life. - adapting the operating conditions to the directions
of the oil supplier.
Mineral oil
For systems with PVG 32 valves Danfoss Before using other biodegradable fluids, please
recommends the use of mineral-based hydraulic oil consult the Danfoss Sales Organisation for
containing additives: Hydraulics.
Type HLP (DIN 51524) or HM (ISO 6743/4).
Non-flammable fluids
Phosphate-esters (HFDR fluids) can be used
without special precautions. However, dynamic
seals must be replaced with FPM (Viton) seals. So
please contact the sales organisation for Danfoss
Hydraulics if the PVG 32 valve is to be used with
phosphate-esters.
Particle content, Oil filtration must prevent particle content from In our experience a degree of contamination of
degree of contamination exceeding an acceptable level, i.e. an acceptable 19/16 can be maintained by using a filter fineness
degree of contamination. Maximum contamination as described in the next section.
for Danfoss PVG 32 is 19/16 (see ISO 4406).
Calibration in accordance with the ACFTD method).
Filtration Effective filtration is the most important precondition In systems with differential cylinders or
in ensuring that a hydraulic system performs reliably accumulators the return filter must be sized to suit
and has a long working life. Filter manufacturers the max. return oil flow. Pressure filters must be
issue instructions and recommendations. It is fitted to suit max. pump oil flow.
advisable to follow them.
Internal filters
System filters The filters built into PVG 32 are not intended to filter
Where demands for safety and reliability are very the system but to protect important components
high a pressure filter with bypass and indicator is against large particles. Such particles can appear in
recommended. Experience shows that a 10 µm the system as a result of pump damage, hose
nominal filter (or finer) or a 20 µm absolute filter (or fracture, use of quick-couplings, filter damage,
finer) is suitable. starting up, contamination, etc.
It is our experience that a return filter is adequate in
a purely mechanically operated valve system. The filter in the electrical actuator PVE protecting
the solenoid valves has a mesh of 150 µm.
The fineness of a pressure filter must be selected as
described by the filter manufacturer so that a Bursting pressure drop for internal filters is
particle level of 19/16 is not exceeded. 360 psi (25 bar).
36 HK.57.B1.22
BACK
4/3 closed
7033 7032 7031 7030 7015 7010 7011 7012 7013
PC → A & B
4/3 open
7132 7131 7130 7135 7115 7110 7111 7112 7113
PC → A & B
4/3 closed
7064 7063 7062 7061 7040 7041 7042 7043 7044
PC → A
4/3 closed
7074 7073 7072 7071 7051 7052 7053 7054
PC → B
4/3 open
7164 7163 7162 7161 7141 7142 7143 7144
PC → A
4/3 open
7174 7173 7172 7171 7150 7151 7152 7153 7154
PC → B
4/3 A → T
7473 7472 7452 7453
PC → B
4/3 B → T
7563 7562 7541 7542 7543
PC → A
Main spools
4/3 closed
for hydraulic 9010 9011 9012
PC → A & B
actuation
HK.57.B1.22 37
BACK
7026 7024 7023 7022 7021 7020 7025 4/3 closed 7005 7000 7001 7002 7003 7004 7006
7126 7124 7123 7122 7121 7120 7125 4/3 open 7105 7100 7101 7102 7103 7104 7106
7424 7423 7422 7421 4/3 A → T 7401 7402 7403 7404 7406
Spools for
hydraulic actuati- 9024 9023 9022 9021 9020 9025 4/3 closed 9000 9001 9002 9003 9004
on
9124 9123 9122 9121 9120 9125 4/3 open 9100 9101 9102 9103 9104
Spools for
friction detent, 9724 9723 9722 9721 9720 4/3 closed 9700 9701 9702 9703 9704
PVMR
9734 9733 9732 9731 9730 4/3 open 9710 9711 9712 9713 9714
Spools for
mechanical float 9824 9823 9822 9821 9820 9825 4/4 P → A → F
position PVMF
Spools with
linear flow 9774 9773 9772 9771 4/3 closed 9750 9751 9752 9753 9754
characteristic
9784 9783 9782 9781 4/3 open 9760 9761 9762 9763 9764
4/3 A → T 9794
4/3 B → T 9804
38 HK.57.B1.22
BACK
Weight, lb 0.3 0.6 0.7 0.9 1.0 1.1 1.3 1.4 1.6 1.7 Plug A or B 2002 0.09
Valve A or B 2001 0.1
HK.57.B1.22 39
BACK
40 HK.57.A2.22
BACK
Order specification
An order form for Danfoss PVG 32 hydraulic valve is Standard and option assembly
shown on the next page. The form can be obtained The PVG 32 valve group is assembled the way the
from the Danfoss hydraulics sales organisation. module selection chart shows if the code number for
PVM is written in field a, and the code number for
Both the module selection chart on the previous PVMD, PVE or PVH in field c.
pages and the order form are divided into fields
0, 1-10, 11, 12, 13, a, b, and c. The valve group is assembled so that the mechani-
cal actuator is mounted on the opposite end of the
Each module has its own field: basic module, if the code number for PVM is written
0: - Pump side module PVP in field c of the order form and the code numbers for
- Plug for external pilot oil supply PVPC PVMD, PVE or PVH in field a.
- Electrical LS unloading valve PVPX
1-10: Basic valves PVB Reordering
13: Main spool PVBS The space at the top right-hand corner of the form is
a: Mechanical actuator PVM for Danfoss to fill in. The code number for the whole
c: - Cover for mechanical actuation PVMD of the specified valve group (PVG No.) is entered
- Cover for hydraulic actuation PVH here.
- Cover for mechanical detent PVMR
- Cover for mechanical float PVMF In the event of a repeat order all you have to do is
- Electrical actuators PVE enter the number Danfoss has given on the initial
b: - Shock and suction valve PVLP confirmation of order.
- Suction valve PVLA
11: End plate PVS
12: Assembly kit PVAS
Please state
- Code numbers of all modules required
- Required setting (P) for pump side module
- Required setting of LSA/B pressure limiting valves,
see pressure setting guidance below.
Pressure setting limits The figures in the table have been calculated
The maximum setting pressure for the pressure according to the following expressions:
limiting valves LSA or LSB depends on the chosen - PVLP ≤ 2175 psi (150 bar): LSA/B ≤ 0,8 × PPVLP
pressure setting for shock valve PVLP. - PVLP > 2175 psi (150 bar): PPVLP - LSA/B ≥ 435 psi
(30 bar).
The maximum values recommended to avoid intera-
ction can be read in the following table.
Max. pressure setting of LSA and LSB valves relative to PVLP shock valve
Setting pressure for PVLP (psi) 460 720 910 1160 1450 1810 2030 2175 2320 2540 2755 3045 3335 3480 3625 3840 4060 4350 4640
Setting pressure for PVLP (bar) 32 50 63 80 100 125 140 150 160 175 190 210 230 240 250 265 080 300 320
Max. setting pressure for LSA/B (psi) - 580 720 930 1160 1450 1625 1740 1885 2100 2320 2610 2900 3045 3190 3405 3625 3915 4205
Max. setting pressure for LSA/B (bar) - 40 50 64 80 100 112 120 130 145 160 180 200 210 220 235 250 270 290
Min. setting pressure for LSA/B psi (bar) 435 (30)
HK.57.B1.22 41
BACK
PVG No.
Proportional Valve PVG 32
Subsidiary/Dealer
Specification
Customer Application
p= psi 157B
12 157B
Filled in by Date
42 HK.57.B1.22
BACK
Comments
Comments
HK.57.B1.22 43
BACK
ISO 9001
INTERNATIONAL STANDARD
INTERNATIONAL ORGANIZATION FOR STANDARDIZATION
ORGANISATION INTERNATIONALE DE NORMALISATION
ISO
9001
Catalogues and leaflets are available with detailed information on the following hydraulic components:
Please contact the Danfoss Sales Organization for Hydraulics for further information
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
DK-6430 Nordborg
Denmark