You are on page 1of 8
ooo > AIPHONE APARTMENT HOUSE INTERCOM SYSTEM MODELS; Bivane VC-OM, VC-1M,VC-2M VC-4M, VC-6M, VC-8M oe VCH-8, VCH-16 VC-26MY,VC-42MY VC-26MT, VC-58MT (Apartment station) (Entrance station, 0-/1-/2-call) {Entrance station, 4-/6-/8-call) {Entrance station, 10-call) (Add-on calll button panel, 8-/16-call) (One-paneled entrance station, horizontal type. 26-/42-call) {— do —, vertical type, 26-/58-call) INSTRUCTIONS vc-10M VCH-16 NOTE; The appearances of the other entrance station models are the same as VC-10M or VCH-16, excopt the number of call buttons. i" con Tr Spo gu (VEH-16 nas two ste 4]: NAMES AND FUNCTIONS | “| veroM, verse; an 2 AIPHONE rark ® Speaker/mic unit Door release button © Call button with directory ® Back box SYSTEM FEATURES Loopewiring system by 4 common plus 1 individual wires per station (3+ 1, door release isnot required), Maximum two VC stations per apartment, Seven entrance station models with & or 16a add-on panels to meet smal to larger apartments. Directory card back illumination Ono-paneled entrance stations available either vertical or horizontal type VC-BBX surface-mount back box for VCnM & VCH panels. vc-26mY vc-42my ° —oot] Soo 0 an SoS Sc a Lo) CoE Ecos Gace |, ese) | Colo] Caofor 7) GSofoL [esas Soe sce Loo) Coes ¢ IQ}Oc—I Coo cp Soc) f | 298mm (184 L ast om (173 89mm (13308" 82 mm (19.918 vc-26MT vc-58MT Mumm 499 om dirs aeaine SRE isa, eee = 209 mn 13.398" NOTES; The above drawings illustrate @ full compliment of call buttons mounted on each panel. BEFORE YOU INSTALL AND OPERATE THE EQUIPMENT - Prohibitions and precautions = * Operation; 1, DO NOT HOLD HOOK SWITCH DOWN WHILE PICKING UP HANDSET, THE CALL TONE SOUNDS THRU THE HANDSET RECEIVER ELEMENT AND COULD CAUSE HEARING DAMAGE, 2. Common talk system. Your conversation with entrance station can he heard if other apartment station pi 3. Calling & communication are not available between two room stations, if installed, in the same apartment. ks up handset * Installation: 1, DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES, 2. Only one entrance station per system, » Unit selection; ‘The VCKIVC- M models are nat compatible with the existing models: VA-K/VAM-/VAM-A. * Maintenance; 1, Clean your VC-K station with a soft cloth dampened with neutral household cleanser. Never use thinner nor benzine, Do not splash water on the entrance station by hose, ete. Call bution unit can be replaced individually. 3 SYSTEM COMPONENTS SOT PaO ‘Apartment sation; | eK tment station wth DOOR | One or wo perapariment. | * Mountson SINGLEGANG BOX CEASE bution, Wa:mount VEoM | Entrance station with buck box. | One per stem, } sMounsson the supplied hack box va + BACK HON DIMERSTONS: ve ao Seal feast mm 1/16") is fo) FS W: 136 mm (6/8) ve )=a eS De "68mm (211/169 Joa) can + Surfacemount back box ve = q Svatatie ask box VORBX vc a cea, | Onespanciedentznce tation | One per system * Twa to four back boxes can be Sih ack bor, 36a Sted before Hash mounting Yo wall fo aca a decal ao. Sea Adan pane ‘cits | Adgon piel with cll buttons. | Any number * taxa one P5135 (or PS-12C) power varie | Ste Tebuttons Sippy for one VEM pus up ta VER and an addons! power spply Toreiey vee VCH Hectic dope eae. (ne por system, ACLIV,230 ma Door elas ea adaptor. 1 pe. Contact rating for electric door release, _ ‘Max. AC/DC 24V, 258 * ower supply adaptor ne for one VOM + 0 VCH, | * No ational power sappy ACh Te SeY, S30 Dav ‘Uditonal for evry three VCiL| "required when the buck dunation Stia0 He Shot wire Output! Be 12v, Aciav. Go De 13V only do ULICSA LISTED. De 12 Wor Nowth Amerie, _ _ Relay adaptor for chine or (ne pss room station. ‘Contact rating; Mas. AC/DC 24V, 2.54. bese $hime on bazaar ust be powsied | sparsely rom the stem | INSTALLATION (1) ACTUAL TERMINAL LOCATION for communication (VC-K to entrance station) Sea youpaabue : for communication (Entrance station to VC-K) oe BaSaGsacsl for grounding ee eee for door release : for call signal for power supply (DC 12V) Vox INSIDE VIEW VEM PANEL BACK VIEW Ee ee ace (2) WALL-MOUNTING INSTALLATION vC-K TERMINAL SECTION, \ (1) Separate front case from chassis by removing a serew and 5-pin connector. Sincte. (2) Attach the chassis to either SINGLE-GANG Pc Boar: i (@) Reattach the female connector to receptacle onPC bose Be careful withthe sharp 35/16 6omm | (5) Remount the front case. Oe CASE t When mounting VOX to wall directly, ‘mow the bottom rt pat oon = (1) Cut out a hole inthe wall of H. 230 mm (9-1/16") Vo-nm SCREW (x4) x W: 156 mm (6-1/8"), securing depth of 68 mm WASHER x Gite". a “ (2) Pass cable thru either of knock-out holes and 2 « connect wires to terminals on back of front ~ nel, (G) Attach the front panel to back box with the supplied 4 screws. ‘paoinm | NOTE: Be careful that the connected wires should be tae put to either side neatly, in order not 10 ‘create shadows by the directory card illumina- Girton tion, When mounting VC-nM and VCH unit(s), boxes in the wall with 186 mm (7-5/16" between two box centers. Be ee SL a ihe l scx moe | ‘Box 188 1m. VC-nMY, VC-nMT = To instal one-paneled VCM back boxes into the wall; iT Te = & oo cL a tad vanes (ove torvoesnri \s shown, connect fo, three oF four back oa oo As shown, connec fou boxes by sliding into the slots each other, ‘until firmly locked by the claw Make sure that all the boxes are put together with the UP mark pointing upward, To pass wiring cable, open knock-out holes in the boxes, which are also necessary for passing jumper wire from each call button block to terminal B on back of SP/mic. unit, as shown in the right, ‘piper our ~s— 3 WIRING DIAGRAMS (1) WHEN USING AC-OPERATED DOOR RELEASE; For Nozth America only. ‘eas | ! ENTRANCE STATION APARTMENT vein eae STATION a (e £5) [1a] = {| =I 5 [| camas | ae iE GH-_13) z SH) <3 |B 3] | ict [a] power Supety | [@} {a t sone s TERMINAL | fe TERMINAL —=! a HMMs} i} Be rasp ee Tat = fi suack pa, He | RYPA Biack | RYPA| |vELLow piace < cH L | erace |*Y** | = ee | : a RK + KJ yeLwowe— x coor fw neLease | . > ae DOOR RELEASE EL-9S. POWER SUPPLY pss (2) BASIC SYSTEM WITH DC- OPERATED DOOR RELEASE, IR ENTRANCE STATION <<} ie] voam oe) Bi) [ aanrwen ea +9 t+] 1 | t 1 7 i e 1 fla jist lI ' =] vt ' commen o HSH Yao} Ha torrsize) it; mt ! no |e SEE EH HE eae venom] | (H+ HH HS HH} ~ 1 1 1 Tecaae) nv-rafvetcon,,| | ae a} a} et r a) | | 1 TERMINAL {_———_ | rower]! Onencn t t H suey |! once strroN 1 1 Fon cue = l tin. OR BUZZER | | z 1 1 Lhe ' DOOR RELEASE t t ! 2 | Ben bo a fl NOTES; @ In APARTMENT # © , two room stations can be signalled by tone simultaneously, when called by entrance station. Calling is not available between room stations A and B. ® DCoperated door release can be connected to (L#] , [L =) terminals directly. @ Forcall extension, use either chime or buuzzer locally avsllale, rated less than DC 24V, 2.5A. DIRECTORY CARD BACK ILLUMINATOR INSTALLATION REPLACING CALL BUTTON UNIT To; )[=] on ve-ntay Desoider on | ge wanes Ly + Se © Devolder the bus wire ATTAGH THE PLATE TO “a” OR “8” POSITION WITH (® Unserow tho terminal 2 SCREWS SUPPLIED, WITH LAMP DOWNWARD. & Detach the switeh uni NOTE: VC-IM~VC-10M & VCH: Use position 8 push the caw. VGH-16; Use postions Aand B. Be caretul not to love the spring and button, OPERATIONS ENTRANCE STATION APARTMENT STATION ecg ES) uw A CO vu Ws vr Depress CALL button of Electronic buzzer sounds Pick up handset to reply. Depress and hold Door SPECIFICATIONS * Power source: DC 12V. Use PS-12S or PS-12A (or PS-12C in North America) power supply. Current consumption: 80 mA (at intercom), 100 mA (at lamp), Calling: Electronic buzzer tone (Frequency; Approx. 600 Hz.) Talk channel: Single channel, common talk system. Wiring: 4 wires in common + 1 individual per apartment (3 wires plus 1, if door release is not included). Wiring distance: (Line resistance; Max. 35 ohm looped), © Between VCM & VCK; [Dancer [0mm Oa mm ‘mn Ditaes 20m 330% som] | | 22 AWG, 20 AWG 18 AWG _ 1,100" 1,650" 2,500" Breen power sippy an door Halon! (Une wesstanse? Max. 4 ob foped) - 0.6mm 0.65 mm [08mm 1.0mm 7 30m 40m oom | 90 m AWG — AWG aoawG | 18 AWG Distance eee ee 125" 280" wr Wah Dak) 260 mm U0) | 186 mm C5I16") 2am Ger) | 230 mm (9-1/16") 156 mm (6-1/1 210mm (81/3) 80 mm 3 264 mm (103/8") 190 mm (7-1) 68mm WARRANTY [ee 2 ial and workmanship under normal wie and service for 8 period of one yea alter delivery the ultimate user and will repair tree of charge oF replace at no charge, should i become defective upon which ‘examination shal ssclse 10 be defective and under warranty. Aiphone reserves unto itself the sole right to make the Final decision Shether theresa detect in materials andor workmanship: and whether of not the producti within the warranty This warranty shall not apply to any Aipnone product which has Been subject to misuse, nee This waranty does not cover batteries or damage caused by batteries used in connection with the procuct. This warranty covers bench repairs only, and any repairs must be made atthe shop or place designated in writing by Aiphone, Aiphone sll pot be responsible for any cost ncutred invalving on ste service eal Reese @ AIPHONE vee) 08340

You might also like