Wi-Fi GPS Healthy Check
DC Input Supply
Basic Features
¶ Linux operating systems.
¶ 1 x WiFi, configurabel as Client or Access Point.
¶ 2 x RJ45 Ethernet 10/100baseT.
¶ 1 x GPS receiver.
¶ 1 x USB hosts, 1 x microUSB Console.
¶ 4 x Serial ports : 2 x RS232 (RJ45) and 2 x Rs485.
¶ 4 x LED Bar for GSM signal strength indicators.
Router functions
¶ 4 x LED Status protocol & devices links.
¶ transparant routing Ethernet to 3G/4G Cellular.
¶ 4 x LED Status for Serial Comm.
¶ transparant tunneling Serial over TCP/IP Cellular.
¶ DIN-rail mounted or Panel Wall-Mounted.
¶ IPv4 and IPv6 addressing.
¶ VLAN IEEE 802.1Q.
SCADA functions
¶ VPN (IPsec, L2TP, GRE).
¶ 20 x Digital Inputs (5kV optical isolation).
¶ support VRRP scheme.
¶ 8 x Relay Outputs (with logic interlock).
¶ Network Timing Protocol (NTP) client.
¶ 2 x Analog Inpurts (0-5 VDC).
¶ NAT (Network Address Translation).
¶ Run multi-protocols concurrently (multi-masters and
¶ Routing protocol (BGPv4, OSPF, and RIP).
multi slaves).
¶ standard SNMP agent (for connection to any NMS
¶ Supported Protocols :
SNMP Manager).
o IEC 60870-5-104 Slave direct and Open VPN
o IEC 60870-5-101/104 Master & Slave Environment
¶ various input supply range with isolated DC-DC 09-36
o DNP 3.0 Serial / TCP Master & Slave VDC, 18-75 VDC, or 43-160 VDC.
o Modbus RTU / TCP Master & Slave ¶ operating temperature : up to +60o C.
o EDF HNZ RTU Master & Slave ¶ Standard Indoor IP 40.
¶ Outdoor IP 56 need to use separated box/panel.
o IEC 60870-5-103 Master
o ABB SPAbus Master Applications
¶ Substation Universal Concentrator with 3G/4G.
o IEC 61107 (FLAG) / 62056-21 / COSEM/DLMS
¶ Distribute Terminal Unit Concentrator with 3G/4G.
Available ¶ Automatic Meter Reading.
o IEC 61850 Server and Client Protocols and ¶ Ground Fault Detector (GFD) Alarm Monitoring.
¶ SCADA Concentrator for devices:
other required Features Ø NULEC ADVC & PTCC
Ø Cooper
Advanced Features Ø Entec EVRC 2A & ETR 300
¶ Healthy-Check controller w/ automatic recovery Ø SEL 351 & 551
Various reboot policies: SMS or Automatic Ø Vamp 40 & 52
(by Application or Hardware/MicroController). Ø ABB PCD2000, ABB REC523, ABB REC615 & ABB
REF615
Cellular 3G/4G connection Ø Kepco
¶ Dual SIM redundancy (active-standby). Ø Kwangmyung
¶ Auto GPRS/3G/4G selection/connection. Ø Shinsung
Ø Siecom
www.integrateknik.com infointek@integrateknik.com
UC-504G RTU+ (dual SIM)
Specifications
DI/DO
USB1 GPS Eth LAN 4G WiFi
Test CB 8 x Relay Outputs with N/O Contact Rating: 2A @ 48VDC
USB2 USB1 Eth LAN Rst
DO-1 C-1 DO-2 C-2 DO-3 C-3 DO-4 C-4 DO-5 C-5 DO-6 C-6 DO-7 C-7 DO-8 C-8 ROE GPSSIM 2 4G WiFi
SIM 1
Open Close
Open Close SIM 2
SIM 1
Test CB DO-1 C-1 DO-2 C-2 DO-3 C-3 DO-4 C-4 DO-5 C-5 DO-6 C-6 DO-7 C-7 DO-8 C-8 ROE
8 x Relay Outputs with N/O Contact Rating: 2A @ 48VDC
Link
Link11 COM
COM11
Link
Link22 COM
COM22
Link
Link33 COM
COM33
Link
Link44 COM
COM44
UC
UCRun
Run DC
DCInIn
DC Input Supply
RS232 Isolated Rs485 4-20mA 0-5 VDC
COM3 Isolated Rs485
COM4 4-20mA 0-5 VDC
9 - 36 VDC mUSB
mUSB
COM1
COM1 RS232
COM2
COM2 COM3 COM4 AI-1
AI-1
AI-2
AI-2
RS485
DI/DO
USB1 GPS Eth LAN 4G WiFi
Test CB 8 x Relay Outputs with N/O Contact Rating: 2A @ 48VDC
USB2 USB1 Eth LAN Rst
DO-1 C-1 DO-2 C-2 DO-3 C-3 DO-4 C-4 DO-5 C-5 DO-6 C-6 DO-7 C-7 DO-8 C-8 ROE GPSSIM 2 4G WiFi
SIM 1
Open Close
Open Close SIM 2
SIM 1
Test CB DO-1 C-1 DO-2 C-2 DO-3 C-3 DO-4 C-4 DO-5 C-5 DO-6 C-6 DO-7 C-7 DO-8 C-8 ROE
8 x Relay Outputs with N/O Contact Rating: 2A @ 48VDC
Link
Link11 COM
COM11
Link
Link22 COM
COM22
Link
Link33 COM
COM33
Link
Link44 COM
COM44
UC
UCRun
Run DC
DCInIn
DC Input Supply
RS232 Isolated Rs485 4-20mA 0-5 VDC
COM3 Isolated Rs485
COM4 4-20mA 0-5 VDC
9 - 36 VDC mUSB
mUSB
COM1
COM1 RS232
COM2
COM2 COM3 COM4 AI-1
AI-1
AI-2
AI-2
RS485
Link
Link11 COM
COM11
Link
Link22 COM
COM22
Link
Link33 COM
COM33
Link
Link44 COM
COM44
UC
UCRun
Run DC
DCInIn
DC Input Supply
RS232 Isolated Rs485 4-20mA 0-5 VDC
COM3 Isolated Rs485
COM4 4-20mA 0-5 VDC
9 - 36 VDC mUSB
mUSB
COM1
COM1 RS232
COM2
COM2 COM3 COM4 AI-1
AI-1
AI-2
AI-2
DI/DO
USB1 Eth LAN1 WiFi
Test CB 8 x Relay Outputs with N/O Contact Rating: 2A @ 48VDC Eth LAN2
DO-1 C-1 DO-2 C-2 DO-3 C-3 DO-4 C-4 DO-5 C-5 DO-6 C-6 DO-7 C-7 DO-8 C-8 ROE
Open Close
1
2
3
4
Link 1 COM 1
Link 3
COM 2
COM 3
UC Run
COM 4
DC In
20 x Digital Inputs with Sensing = DC Input Supply & 2 x Groups Separated DI Common
DI-C1 DI-01
DI-C1 DI-02 DI-03 DI-04 DI-05 DI-06 DI-07 DI-08 DI-09 DI-10 DI-C2 DI-11 DI-12 DI-13 DI-14 DI-15 DI-16 DI-17 DI-18 DI-19 DI-20
RS485
RS485
DI/DO
USB1 Eth LAN1 WiFi
Test CB 8 x Relay Outputs with N/O Contact Rating: 2A @ 48VDC Eth LAN2
DO-1 C-1 DO-2 C-2 DO-3 C-3 DO-4 C-4 DO-5 C-5 DO-6 C-6 DO-7 C-7 DO-8 C-8 ROE
Open Close
1
2
3
4
Link 1 COM 1
Link 3
COM 2
COM 3
UC Run
COM 4
DC In
20 x Digital Inputs with Sensing = DC Input Supply & 2 x Groups Separated DI Common
DI-C1 DI-01
DI-C1 DI-02 DI-03 DI-04 DI-05 DI-06 DI-07 DI-08 DI-09 DI-10 DI-C2 DI-11 DI-12 DI-13 DI-14 DI-15 DI-16 DI-17 DI-18 DI-19 DI-20
RS485
RS485
www.integrateknik.com infointek@integrateknik.com