Module (1.1)
Types of A/C Units and System
HVAC SYSTEM
OPERATION AND TYPES
Types of A/C Units and System according to
Air Cooling Methods
2) CH-Chilled Water 1) DX-Direct Expansion
Types of A/C Units and System according to
Air Cooling Methods
2) CH-Chilled Water 1) DX-Direct Expansion
Freon الوحدة Freon
CH. W. الداخلية
Cooling Cooling
Cool Air Indoor
Water Unit Air
(COLD AIR)
لاــمحيط الدـاـخـلى-Interior
DX Units types
DX-Direct Expansion تكييف مباشر للهواء
DX-Components
DX-Package Unit DX-Ducted Split
Ducted
وحدة منفصلة
Split Unit
Features
المميزات
*To be fixed in lower floors at multi
story villas. * تركب في األدوار السفلي من المنازل
*multi story buildings. المتعددة األدوار.
& *Occupied less outer space * العمارات السكنية متعددة األدوار.
reduce ducting. * تشغل مساحة خارجية اقل.
*Can connect more than one room. * توفر في مجاري الهواء ومساحة
*Give more flexibility for decoration.
اإلشغال.
*Cheaper than package units.
* يمكنها ربط أكثر من غرفة
*Difficult to replacing the future if
needed. * تتيح التحكم في تصميم الديكورات.
*Efficiency Ratio: 1.8 kw per ton in * أقل في التكلفة وأرخص من المدمجة.
average. * أصعب عند االستبدال في المستقبل.
* كفاءة التبريد 1,8 :كيلوات لكل طن
تبريد فى المعدل.
Ducted Split Unit
وحدة مدمجة
Package Unit
* To be fixed at villas of one floor. * تركب في المنازل ذات الدور
*To be fixed at higher floor in الواحد
multi story villa.
* تركب في الدور العلوي للمنزل
*Easier to maintain &
repair ذات الدورين
*Less inconvenience. * أسهل في الصيانة وعند اإلصالح
*Easier to replace in the future. .* أقل إزعاجا ألهل البيت
*Efficiency Ratio: 1.6 kw per ton * أسهل عند االستبدال في
in average .المستقبل
كيلوات لكل1,6 :* كفاءة التبريد
طن تبريد فى المعدل
Features المميزات
PKG in Duty
وحدة منفصلة
Mini-Split Unit
Features المميزات
PARTS
Condenser
compressor,
propeller fans
and controls
These are the most common
system used in residential and
light commercial applications.
Chilled Water System with Air
Cooled Condenser
Condenser Water System – Cooling Tower
H2O
410A
PD
12 Compressors
134
22 11 are ideally
10 143a 134a suited for
DELTAH, (Btu/lb)
500 113
507 124
123 higher lift
8
502 12 Centrifugal
125 114
6 Compressors
have high
4 volumetric
CENTRIFUGAL flow
2
0
.1 1 10 100
50
CFM/TON
وحدات دفع الهواء
Air Handling Units
FAN-COIL UNIT
FCU-Fan Coil Unit is the part of وحدة دفع الهواء هي جزء هام من
Chilled Water System that deliver منظومة التكييف المركزى بالمياه
cooling to independent zones. المبردة تخدم فى األغلب منطقة
These typically used in separate فندقية أو مكتب/محددة مثل غرفة
rooms/guestroom and small offices و ثدفع الهواء البارد عبر,صغير
with limited ductwork for better air مجارى دكت قصيرة لتوزع الهواء
distribution. .بشكل أفضل
FAN COIL UNIT
• It part of an HVAC system found in residential, commercial, and
industrial buildings.
• A simple device consisting of a heating or cooling coil and fan.
• Used to control the temperature in the space where it is
installed, or serve multiple spaces.
• It is controlled either by a manual on/off switch or by
thermostat.
• Fan coil units are more economical to install than ducted or
central heating systems with air handling units.
• They can be noisy because the fan is within the same space.
A/C Unit is: Fan + Coil = FCU
Fan Coil System - Advantages
• Central equipment may be sized smaller by taking
advantage of building heating and cooling diversity.
• The system requires only piping installation which takes
up less space than all-air duct systems.
• It is usually easier to install wire and water pipes than
ducts making this a good choice for retrofit applications.
• Unoccupied areas of the building may be isolated and
shut down, saving money.
• Zones can be individually controlled.
• Can take up to 100% outside air capability (see next slide).
Fan Coil Unit – FCU Components
DESIGN - التصميم
• A fan coil unit may be concealed or exposed within the room or
area that it serves.
• An exposed fan coil unit may be wall mounted, freestanding or
ceiling mounted.
• It typically include an appropriate enclosure to protect and conceal
the fan coil unit itself.
• Return air grille and supply air diffuser set into that enclosure to
distribute the air.
• A concealed fan coil unit will typically be installed within an
accessible ceiling void or services zone.
• The return air grille and supply air diffuser will be ducted to and
from the fan coil unit.
OPERATION التشغيل-
• The coil receives hot or cold water from a central plant, and removes heat
from or adds heat to the air through heat transfer.
• Traditionally fan coil units can contain their own internal thermostat, or
can be wired to operate with a remote thermostat.
• In most modern buildings with a Building Energy Management
System (BEMS), the control of the fan coil unit will be by a local digital
controller. equipment for adding heat to the building's water.
Conceal
FCU
Conceal
FCU
with
Duct
TYPESاـألنواـعـ -
Four-pipe FCU
for Two-pipe
Cooling/Heating FCU for
Cooling Only
High Static FCU
with more TYPESاـألنواـعـ -
ducting
Medium Static
FCU with
ducting
installation
• VERTICAL AHU
HORIZONTAL AHU
Application
homes
offices
institutions
factories
CEILING MOUNTED AHU
•Can be suspended from the ceiling and hence require
Features : no floor space
Cost efficient •Noiseless units and can be placed above the false
High quality product ceiling in the conditioned area
•Units are unobtrusive giving flexibility to the design
Easy to use of the interior
Perfect functionality
Applications :
Shopping Malls
Multiplexes
Small Offices
Ware houses
AHU-according to feeding Area
• single-zone Multi-zones
TYPE OF AHU DEPENDING ON LOCATION OF FAN
Draw through type:
fan located after
cooling coil
DISADVANTAGES
• AHU is physically large and requires careful planning in terms of a suitable
location.
• The space required for ducting and the corresponding holes through building
fabric require careful co-ordination with builders and other mechanical
services within the room.
• Rooms with variable or moving sources of heat gain such solar gain
traversing around the room require sophisticated duct work and controls.
Zone heaters may have to be incorporated into duct branches.
INSTALLATION PROCESS
lifting or rigging the AHU to the
site
locate the AHU in the AHU room
preparing unit for the installation
assembling the unit
cabinet installation
fan installation
electrical installation
coil and piping installation sheet
metal installation
final installation
controls installation
final sensor and actuator
……………………..calibration
verification
Duct & Accessories
COMPONENTS
• Filters
• to provide clean dust-free air to the building occupants
• It may be via simple , HEPA, electrostatic, or a
combination of techniques. Gas-phase and ultraviolet air
treatments may be employed as well.
• Filtration is typically placed first in the AHU in order to
keep all the downstream components clean.
• Depending upon the grade of filtration required, typically
filters will be arranged in two (or more) successive banks
with a coarse-grade panel filter ……..provided in front of
a fine-grade bag filter.
Heating and/or cooling elements
• Air handlers may need to provide heating, cooling, or both to
change the supply air temperature, and humidity level depending on
the location and the application.
• Such conditioning is provided by heat exchanger coil(s) within the
AHU air stream, such coils may be direct or indirect in relation to
the medium providing the heating or cooling effect.
• Coils are typically manufactured from copper for the tubes, with
copper or aluminum fins to aid heat transfer.
Dehumidifier لاـمبخـــــــرـ
• If dehumidification is required, then the cooling coil is
employed to over-cool so condensation occurs. A
heater coil placed after the cooling coil re-heats the air
to the desired supply temperature. This has the effect of
reducing the relative humidity level of the supply air.
Humidifier
• Humidification is often necessary in colder climates where continuous
heating will make the air drier, resulting in uncomfortable air quality
• Vaporizer:
steam or vapor
from a boiler is
blown directly
into the air
……….stream.
Humidifier المبخـــــر-
• Humidification is often necessary in colder
climates where continuous heating will make
the air drier, resulting in uncomfortable air
quality
• Various types of humidification may be used:
• Spray mist: water is
diffused either by a nozzle
or other mechanical means
into fine droplets and
carried by the air.
• Ultrasonic: A tray of fresh
water in the airstream is
excited by an ultrasonic
device forming a fog or
…………water mist.
Humidifier المبخـــــر-
• Humidification is often necessary in colder climates
where continuous heating will make the air drier, resulting
in uncomfortable air quality
• Various types of humidification may be used:
• Wetted medium: A fine fibrous
medium in the airstream is kept
moist with fresh water from a
header pipe with a series of small
outlets. As the air passes through
the medium it entrains the water
in fine droplets. This type of
humidifier can quickly clog if the
primary air filtration is not
maintained in good order.
Mixing chamber
• In order to maintain indoor air quality, air handlers
commonly have provisions to allow the introduction
of outside air into, and the exhausting of air from
the building.
• In temperate climates, mixing the right amount of
cooler outside air with warmer return air can be
used to approach the desired supply air temperature.
A mixing chamber is therefore used which has
dampers controlling the ratio between the return,
outside, and exhaust air.
Blower/fan
• Air handlers typically employ a large blower .
• The blower may operate at a single speed, offer a
variety of set speeds, to allow a wide range of air
flow rates. Flow rate may also be controlled by inlet
vanes or outlet dampers on the fan
• Multiple blowers may be present in large
commercial air handling units, typically placed at
the end of the AHU and the beginning of the supply
ductwork .
Heat recovery device
• A heat recovery device heat exchanger of many types, may be fitted to
the air handler between supply and extract airstreams for energy
savings and increasing capacity. These types more commonly include
for:
Heat recovery device
• Recuperate, or Plate Heat exchanger: A sandwich of plastic or metal
plates with interlaced air paths. Heat is transferred between airstreams
from one side of the plate to the other. The plates are typically spaced at
4 to 6mm apart. Heat recovery efficiency up to 70%.
Heat recovery device
• Thermal Wheel, or Rotary heat exchanger: A slowly rotating matrix of
finely corrugated metal, operating in both opposing airstreams.
• When the AHU is in heating mode, heat is absorbed as air passes
through the matrix in the exhaust airstream, during one half rotation,
and released during the second half rotation into the supply airstream.
• When the AHU is in cooling mode, heat is released as air passes
through the matrix in the exhaust airstream, during one half rotation,
and absorbed during the second half rotation into the supply airstream.
Heat recovery efficiency up to 85%.
• Controls
• Controls are necessary to regulate every aspect of an air handler, such as:
• flow rate of air,
• supply air temperature,
• mixed air temperature, humidity, air quality.
• Common control components include temperature sensors, humidity sensors, sail
switches, actuators, motors, and controllers.
• Vibration isolators
• The blowers in an air handler can create substantial vibration and the large area of
the duct system would transmit this noise and vibration to the occupants of the
building.
• To avoid this, vibration isolators (flexible sections) are normally inserted into the
duct immediately before and after the air handler and often also between the fan
compartment and the rest of the AHU. The rubberized canvas-like material of these
sections allows the air handler components to vibrate without transmitting this
motion to the attached ducts.
Overall View
AHU System - Disadvantages
• Long, big in size and expensive GI Duct.
• Taking extra space from the building.
• Relatively high noise levels (at high output)
• Might have week return from far branch.
• High operating and maintenance costs (for
changing the filter and fan)