GTX Series
Industrial Grade UPS for Critical Application

• True online double-conversion


• Wide input voltage range (110-300 VAC)
• Input power factor correction 0.98
• Bigger wattage output power
• 50Hz/60Hz frequency converter mode
• Programmable power management outlets (Settable backup panod output)
• Emergency power off function (EPO)
• Green ECO mode operation for energy saving
• Generator compatible
• Charger capacity expansion for long backup time.
• Smart battery charger design for optimized battery performance
• Selectable output voltage: 208-240VAC
• Manual bypass/load on main mode function
• Standard smart LCD display & USB interface

GTX 2.25 VA
GTX 3.35 VA
GTX 1.15 KVA
LCD Display Panel Accessories
MODEL NEUTRON 650 NEUTRON 1250
SNMP Card AS-400 Card Mantenance Bypass
Switch/PDU
CAPACITY VA/W 650VA 1250VA
Voltage 110/120 VAC or 220/230/240VAC
INPUT
Voltage Range 81-145VAC or 162-290VAC
Voltage 110/120 VAC or 220/230/240VAC
Voltage Regulation
(Battery Mode) +/-10%
OUTPUT
EW GTX
FrequencyNRegulation SERIES SPECIFICATION
(Batt. Mode) 50Hz or 60Hz ± 1 Hz
MODEL GTX 1.150 VA GTX 2.250 VA GTX 3.350 VA
CAPACITY* Output Waveform 1150 VA 2250 VA
Simulated Sine Wave 3350 VA
INPUT
Battery Ty
Low Line Transfer pe & Number*
160VAC/140VAC/120VAC/110VAC±5%
12V7Ah x 1pc or 80VAC/70VAC/60VAC/50VAC±5%
12V7Ah x 2pcs
( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
Voltage
BATTERYLow LineBack
Range up Time
Comeback Up to 15 minutes
175 VAC ± 5 % or 85 VAC ± 5 %Up to 30 minutes
High Line Transfer 300 VAC ± 5 % or 150 VAC ± 5 %
High Line Comeback 290 VAC ± 5 % or 145 VAC ± 5 %
Frequency Range
Recharge Time 4-6 hours to 90% after complete discharge
40Hz ~ 70 Hz 8 hours recover to 90% capacity
Phase Single phase with ground
Power Factor
AC Mode Green
≧ 0.99 @ 220-230 VAClighting
(input voltage)
OUTPUT
INDICATOR Battery Mode Yellow flashing
Output voltage 208/220/230/240VAC or 110/115/120/127 VAC
AC Voltage Regulation
Fault Red Mode)
± 3% (Batt. lighting
Frequency Range
47 ~ 53 Hz or 57 ~ 63 Hz
TRANSFER
(SynchronizedTIME
Range)Typical 4-6ms
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
Current Crest Ratio Phone/fax/DSL/Network 3:1
Surge Protection ≦ 3 % THD RJ-11 (One In One Out)
(Linear Load) ≦ 4 %RJ-45 (One In One Out)
THD (Linear Load)
Harmonic Distortion
≦ 6 % THD (Non-linear Load) ≦ 7 % THD (Non-linear Load)
PROTECTION EMI/RFI Filter Full time
Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY
AC Mode AC Input ~ 85% Circuit breaker ~ 88%
Green ECO Mode ~ 97%
BATTERY Full Protection Overcharge and Overload Protection
Battery Type 12 V / 7 AH 12 V / 7 AH 12 V / 9 AH
NumbersDimension DxWxH (mm) 330 x 100 x 145
3/4(extended) 6/8(extended) 350 x 146 6/8(extended)
x 160
PHYSICAL
Standard
Recharge Time 4 hours recover to 90% capacity (Typical)
Model Net Wei ght (kgs)
Charging Current 5.0 1.0 A(max.) 8.0
Charging Voltage
Operating Environment41.0/54.6 VDC ± 1% 0-90Depending
Battery Type % RH @on
82.1/109.4 VDC ±1%
0-applications
40°C (non-condensing)
Long-run
ENVIRONMEN Numbers 3/4(extended) 6/8(extended)
Model
T Noise Level
Charging Current 4.0 ALess
or 8.0than 40dB
A (max.)
Charging Voltage 41.0/54.6 VDC ± 1% 82.1/109.4 VDC ±1%
INTERFACE
PHYSICAL USB Windows 98 SE/ME/NT 4.x/2000/2003/XP/Vista/2008
Standard Dimension, DXWXH (mm) 397X145X220 421X190X318
* Model
Product specifications are subject to change without
Net Weight (kgs) 13.2 further
/ 16.2 notice 26.0 /32.0 28.6 / 35.6
Dimension, DXWXH
Long-run 397X145X220 421X190X318
(mm)
Model
Net Weight (kgs) 6.9 / 9.9 13.0 / 16.0 15.0 / 22.0
ENVIRONMENT
Operation Temperature 0- 40°C (the battery life will down when > 25°C)
Operation Humidity 20-90 % RH @ 0- 40°C (non-condensing)
Operation Altitude** <1000m
Acoustic Noise Level Less than 45dBA @ 1 Meter
MANAGEMENT
Smart RS-232 or USB Supports Windows® 98/2000/2003/XP/Vista/2008, Windows® 7, Linux, and MAC
Optional SNMP Power management from SNMP manager and web browser
* Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
**If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
***Product specifications are subject to change without further notice.