Line Modules Task Oriented Procedures 421 TOP-0003a: Replacing an In-service AOFx-1200/SOFx-1200 Description This TOP describes the procedure to replace an in-service line module: = Advanced OTN FlexChannel Line Module 12006 (AOFM-1200) = Advanced OTN FlexChannel Switching Line Module 12006 (AOFX-1200) = Submarine OTN FlexChannel Line Module 12006 (SOFM-1200) = Submarine OTN FlexChannel Switching Line Module 1200G (SOFX-1200) This TOP describes the procedures to replace a non-IB and IB (with License types (Regular and Transferable) with their respective Line module types. ‘The XTC-10 can contain up to ten line modules. The line modules are installed in upper universal card slots A-1 through A-5 andior lower universal card slots B-1 through B-5 of the XTC-10. Waring: | Traffic Disruption Risk Removing an active circuit pack can result in traffic interruption. Use caution when removing circuit packs and verify that only administratively locked circuit packs are being replaced. > TRAFFIC Caution; Risk of exposure to invisible radiation. Do not view the fibers and optical connectors directly with optical instruments, Class 1 and Class 1M radiation present, Cautlont The equipment is susceptible to Electrostatic Discharge (ESD). Use ESD grounding straps when handling equipment and follow ESD procedures. Caution: The equipment is susceptible to damage if modules are improperly installed. Always Ingpect the backplane for bent pins prior to inserting a module in a card sit. Inspect the Connector blocks on the rear of the module to ensure proper alignment prior to installing into any slot. Ensure that the modules are aligned properly with the card cage ral guides prior to insertion; insert modules slowly and do not use force Caution: Optical connectors can be damaged if their protective covers or dust caps are not installed when the connectors are notin use, > PPP Infinera Corporation Task Oriented Procedures Guide Release 18.2 VO03 Infinera Proprietary and Confidential 422 ‘TOP-0003a: Replacing an In-service AOFx-1200/S0Fx-1200 Required Equipment ™ Line module (AOFx-1200/SOFx-1200) = xTC (xTC-10) 1 Fiber cleaning kit = ESD wrist strap = ESD heel strap = #1 Philips screwdriver 1/4 inch flat-blade screwdriver Assumptions Spare line module is available '= The field technician performing this procedure is familiar with ESD safety procedures 1t The field technician performing this procedure is familiar with GNM "= The field technician performing this procedure is familiar with the XTC 11 The field technician performing this procedure is familiar with the Turn-Up and Test procedures Note: An Equipment Mismatch alarm is generated unless the correct circuit pack type is inserted into the slot Method To Replace a non-B AOFx-1200 /SOFx-1200 ‘Step 1 Log into the network element with network administrator privileges using GNM. Step 2 From the chassis view, right-click on the line module and select Graceful Shutdown. warning message dialog box is displayed. Click OK to shutdown the card. ‘Caution: Prior to removing andior replacing an AOFx-1200/SOFx-1200 from a live XTC-10 ‘chassis, itis recommended to perform a "graceful shutdown operation” on the AOFx-1200) ‘SOF x-1200 (from Infinera management interfaces) to optimize deactivation and intalization of the AOFx-1200/S0Fx-1200, Note that this behavior is specific to AOFx-1200/SOFx-1200 line module types and difers from previous line module types. Step 3 Mark or label the fibers connected between the ports so that you can connect them back after the new line module is installed. ‘Task Oriented Procedures Guide Release 18,2 V003 Infinera Corporation Infinera Proprietary and Confidential Line Modules Task Oriented Procedures 423 Step 4 Disconnect the fibers from the AOFx-1200/SOFx-1200 line module. ‘Step 5 Remove the line module. See TOP-0002: Removing an Out-of-service Line Module on page 4-10. ‘Cauton; In order for the chassis to maintain proper airflow as designed, all unpopulated card slots/sub-slots must have appropriate blanks installed. When removing andior replacing a module, the card slotsub-slot must not be left open for more than five minutes. It is recommended that you install an appropriate blank immediately after removing a module until you are ready to instal the replacement module, ‘Step 6 Do one of the following © Install the new line module of the same type into the slot. See TOP-0001: Installing a Line Module on page 4-2 for the detailed procedure. Skip to Step & Note: When the new line module of the same type has to be installed in a different slot, Contact TAC for further support = Install a newly spared line module into the slot. See TOP-0001: Installing a Line Module on Page 4-2 for the detailed procedure. An Equipment Type Mismatch alarm is raised. ‘See Sparing Matrix for AOFx-1200/SOFx-1200 line modules on page D-15 for more information. Step 7 To clear the Equipment Type Mismatch alarm, do the following: Step 7a Right-click AOFx-1200/SOFx-1200 and select Propertles, The OFX Propertles window is displayed. Step 7b In the Summary panel, from the Provisioned Equipment dropdown select the same PON type as that of the Installed Equipment. Step 7c Click Apply to save the changes. This clears the Equipment Type Mismatch alarm. ‘Step 8 Clean and reconnect all fibers. See Connecting and Routing Fiber Optic and BNC Video Cables on page B-1 ‘Step 9 Check the line module circuit pack status LEDs and service state: ‘Step 9a The PWR (Power) and ACT (Active) LEDs must be lit (Green), and the FLT (Fault) LED must be OFF. If not, check the alarms reported by the line module and follow the appropriate clearing procedures as described in the DTM and DTN-X Alarm and Trouble Clearing Guide ‘Step 9b Check the circuit pack Service stale. It must be in in-service state. If not, check the alarms reported by the line module and follow the appropriate clearing procedures as described in the DTN and DIN-X Alarm and Trouble Clearing Guide To Replace IB enabled AOFx-1200 /SOFx-1200 Line module replacement in same slot with IB icense type Regular and Transferable (R18.1 onwards) ‘Step 1 Log into the network element with network administrator privileges using GNM. Infinera Corporation ‘Task Oriented Procedures Guide Release 18.2 V003 Infinera Proprietary and Confidential 424 ‘TOP-0003a: Replacing an In-service AOFx-1200/S0Fx-1200 Step 2 If the Line module is reachable, do a Graceful shutdown, else skip to Step 3, From the chassis view, right-click on the line module and select Graceful Shutdown. Awarning message dialog box is displayed. Click OK to shutdown the card. ‘Caution; Prior to removing andior replacing an AOFx-1200/SOFx-1200 from a live XTC-10 ‘chassis, itis recommended to perform a "graceful shutdown operation” on the AOFx-1200) ‘SOF x-1200 ((rom Infinera management interfaces) to optimize deactivation and intialization of, the AOFx-1200/S0Fx-1200, Note that this behavior is specific to AOFx-1200/SOFx-1200 line module types and difers from previous line module types. ‘Step 3 Mark or label the fibers connected between the ports so that you can connect them back after the new line module is installed. Step 4 Disconnect the fibers from the AOFx-1200/SOFx-1200 line module. ‘Step 5 Remove the line module. See TOP-0002: Removing an Out-of-service Line Module on page 4-10. ‘Cautlon; In order for the chassis to maintain proper airflow as designed, all unpopulated card slots/sub-slots must have appropriate blanks installed. When removing and/or replacing a module, the card slotsub-slot must not be left open for more than five minutes. It is recommended that you install an appropriate blank immediately after removing a module until you are ready to instal the replacement module, ‘Step 6 Do one of the following = Install the new line module of the same type into the slot, See TOP-0001: Installing a Line Module on page 4-2 for the detailed procedure, Skip to Step &, Note: When the new line module of the same type has to be installed in a different slot, Contact TAC for further support = Install a newly spared line module into the slot, See TOP-0001: Installing a Line Module on page 4-2 for the detailed procedure. An Equipment Type Mismatch alarm is raised. ‘See Sparing Matrix for AOFx-1200/SOFx-1200 line modules on page D-15 for more information Step 7 To clear the Equioment Type Mismatch alarm, do the following: ‘Step 7a Right-click AOFx-1200/SOFx-1200 and select Properties. The OFX Properties window is displayed. Step 7b In the Summary panel, from the Provisioned Equipment dropdown select the same PON type as that of the Installed Equipment. Step 7c Click Apply to save the changes. This clears the Equioment Type Mismatch alarm. ‘Step 8 After the Line module comes up a License Assignment Mismatch/License Type Mismatch alarm with Target System Mismatched alarm condition is raised. ‘The associated license entity indicates an “Activated-Mismatchex state in DNA License Manager, ‘Task Oriented Procedures Guide Release 18,2 V003 Infinera Corporation Infinera Proprietary and Confidential Line Modules Task Oriented Procedures 425 Step 9 To clear the alarm, set the Action for the license entity to Re-assign. Refer to License Management Guide for more information about the Licensing operations. ‘Step 10 Clean and reconnect all fibers. See Connecting and Routing Fiber Optic and BNC Video Cables on page B-1 Step 11 Check the line module circuit pack status LEDs and service state: ‘Step 11a The PWR (Power) and ACT (Active) LEDs must be lit (Green), and the FLT (Fault) LED must be OFF. If not, check the alarms reported by the line module and follow the appropriate clearing procedures as described in the DTM and DTN-X Alarm and Trouble Clearing Guide . ‘Step 11b Check the circuit pack Service state. It must be in in-service state. If not, check the alarms reported by the line module and follow the appropriate clearing procedures as described in the DTN and DIN-X Alarm and Trouble Clearing Guide Infinera Corporation ‘Task Oriented Procedures Guide Release 18.2 V003 Infinera Proprietary and Confidential

You might also like