Professional Documents
Culture Documents
Meets the requirements of: ASTM D 1227, Type II, Class 1 Component
(Asbestos Free); ASTM 1187, Type I; SS-R-1781, MIL-R-3472A
CO
Features and Components Coating
Use: Protective coating over built-up, SBS and APP modified Type
bitumen roofs, and approved substrates.
Type: One-part, asphalt-based, clay emulsion roof coating.
M
Membrane
Multi-Ply
Features: Water based, low VOC, and UV resistant.
Mineral-fiber reinforced.
Breathable; allows water vapor to escape.
System Compatibility This product may be used as a component in the following systems. Please reference product application for specific installation methods and information.
Single Ply
Multi-Ply
HA CA CA HW HA CA HW SA MF FA MF FA MF FA BA
Compatible with all Multi-Ply systems Do not use in Single Ply systems
Key: HA = Hot Applied CA = Cold Applied HW = Heat Weldable SA = Self Adhered MF = Mechanically Fastened FA = Fully Adhered BA = Ballasted
Physical Properties
Spray Brush Long Nap Roller
Property Asphalt Emulsion Roof Coating
Weight 8.9 lb/gal (1.06 kg/l) • Apply when temperature is 45°F (7°C) and rising. Do Not Thin
Residue by Evaporation 51% • Please refer to detailed installation instructions on next page.
Weight
Heat Set no sagging or blistering * Coverage, open and dry time rates can vary dramatically depending on the particular substrate
and environmental conditions. Coverage rates stated herein are approximate only.
no blistering or
Resistance to Water re-emulsification
If FM Global® or UL® approval is required, consult specific RoofNavSM or the UL Certifications
Directory for specific application rates.
Flash Point no spontaneous fire potential
Refer to the Safety Data Sheet and product label prior to using this product.
The Safety Data Sheet is available by calling (800) 922-5922 or on the Web at
www.jm.com/roofing. RS-2066 5-15 (Replaces 10-14)
Asphalt Emulsion Roof Coating
Installation/Application Instructions Precautions
Apply when temperature is 45°F (7°C) and rising. Do Not Thin. Avoid prolonged contact with skin • Avoid contact with eyes • Do not
All surfaces must be swept clean and free from oil, grease, rust, scale, take internally • Keep container closed when not in use • Keep out of
loose paint and dirt. Prime dusty or porous masonry, old roofs and all reach of children.
metal with a bituminous primer before applying the coating.
Stir in the container before applying. Apply with a good quality roof
brush, long-napped roller or commercial grade spray equipment.
Apply two coats. The first coat must be thoroughly dry before applying
the second coat. The coating should not be applied when rain or frost
is forecasted within 24 hours.
Refer to the Safety Data Sheet and product label prior to using this product.
The Safety Data Sheet is available by calling (800) 922-5922 or on the Web at
www.jm.com/roofing. RS-2066 5-15 (Replaces 10-14)