Professional Documents
Culture Documents
// PRECISION
MADE BY ZEISS
2
When darkness led to enlightenment,
when spontaneous retinal damage led to an
effective therapy.
3
ZEISS VISULAS 532s
Mastering everyday life in the clinic.
Reliable. Competent. Superior.
4
Navigating with fingertip precision:
the electronic micromanipulator.
5
ZEISS VISULAS 532s VITE
Expanding with your needs.
Fast. Flexible. Physician-controlled.
6
Handle treatment interruptions with no stress
The physician may interrupt treatment at any time in an instant: with spot precision
within the current sequence and in a controlled manner. This ensures the physician
maximum precision and the patient optimum protection.
[sec]
73.4 s
60
1)
Roeckl A, Blum M: Multispot laser photocoagulation with the VISULAS 532s VITE:
A comparative study of 101 patients, Publication no. 000000-1839-880, LAS.2979, 06 / 2010.
2)
Roeckl A, Blum M: Pan-retinal laser photocoagulation with reduced pulse duration – first experiences
with linear spot cascades, Klinische Monatsblätter der Augenheilkunde, 2011 (DOI: 10.1055 / s-0031-1273432)
7
ZEISS VISULAS 532s VITE
Results to be proud of.
Effective. Gentle. Comfortable.
The VISULAS® 532s VITE from ZEISS offers a clinically effective and gentle
retinal laser therapy for conventional treatment strategies, such as pan-retinal
photocoagulation, central grid coagulation and central focal coagulation.
8
In addition, shorter laser pulses cause less damage to surrounding tissue,
since thermal conduction is not able to progress as far during the shorter pulse
durations, thus protecting the inner layers of the retina (see images). This
significantly enhances patient comfort2). Short pulses create sharply outlined
lesions with highly controlled heat propagation. Clinical research is currently
underway on the potential positive effects of the combination of short pulse
durations and small beam diameters.
234 um
OCT B scans (Cirrus™ HD-OCT by Carl Zeiss Meditec AG) prove: A 20 ms laser pulse shows a less extensive lesion than a
200 ms pulse 3) (the beam diameter was 100 μm in both cases).
2)
Roeckl A, Blum M: Pan-retinal laser photocoagulation with reduced pulse duration – first experiences
with linear spot cascades, Klinische Monatsblätter der Augenheilkunde, 2011 (DOI: 10.1055 / s-0031-1273432)
3)
Dr. Fang Lu, West China Hospital, Sichuan University, Chengdu, China
9
ZEISS VISULAS 532s
A credible team player in operative use.
Adaptable. Portable. Versatile.
10
Technical data VISULAS 532s / VISULAS 532s VITE
Laser type Frequency doubled solid state laser
LASER RADIATION
AVOID EYE OR SKIN EXPOSURE TO
DIRECT OR SCATTERED RADIATION
CLASS 4 LASER PRODUCT
ACCORDING TO
DIN EN 60825-1:2008
532 nm 3W cw
620-650 nm 5 mW cw
000000- 1149-623-03-GB- Vs02
LSL 532s / LSL 532s VITE laser slit lamp
Laser beam delivery Interlaced with slit illumination system
Laser treatment spot size continuously adjustable, 50–1,000 µm
(without contact lens), parfocal, larger spot sizes
depending on contact lens used
Illumination 12 V, 30 W brightness continuously adjustable
Slit adjustment Slit length: variable in steps of 1 / 3 / 5 / 9 / 14 mm
Slit width: continuously adjustable from 0 to 14 mm
Slit image rotation: 0°, ±45°, 90°
Magnification 5 x, 8 x, 12 x, 20 x, 32 x
Physician safety filter True-to-color, ClearView
Micromanipulator Servo-electric
Weight 11 kg (24.2 lbs)
Accessories Tonometer, co-observation tube, video documentation
equipment from the range of accessories for the slit
lamps SL120 and SL130
VISULINK 532 / U
Laser treatment spot size continuously adjustable, 50–1,000 µm
(without contact lens), parfocal
Compatible slit lamps ZEISS SL 115 Classic, SL 120, SL 130, 20 SL, 30 SL
Haag Streit 900 ® BM / 900® BQ
Physician safety filter True-to-color
Weight 0.4 kg (0.9 lbs)
Accessories Transport case for VISULINK 532 / U and VISULAS 532s
ZEISS VISULAS 532s – strong performance in the operating room
With the coagulation laser VISULAS 532s and the surgical microscope
OPMI LUMERA® 700 ZEISS provides surgeons with a perfect duo which interact
in harmony, guaranteeing successful surgical interventions in the posterior eye
segment. The variable view, font size and color contrast of VISULAS 532s display
are predestined for application in the operating room: all parameters are always
clear and distinctly legible – even from a distance and in a darkened environment.
VISULAS 532s and OPMI LUMERA 700
in the operating room
The precise centration of the aiming and therapeutic beam, combined with the
integrated slit illumination of the OPMI LUMERA 700, create an optimally illuminated
treatment field and thus guarantees confident operation, whether in the periphery
or in the vicinity of the macula. The fixed ClearView physician safety filter only
minimally increases the height of the view for the operator. The active physician
safety filter always provides effective protection when the laser is triggered. It gives
the operator unfiltered vision when the laser is not in use.
11
0297
Germany
07745 Jena
Carl Zeiss Meditec AG
Goeschwitzer Strasse 51–52
www.meditec.zeiss.com/contacts
www.meditec.zeiss.com/visulas532s
EN_31_010_0022II Printed in Germany. CZ-I/2017 International edition: Only for sale in selected countries.
The contents of the brochure may differ from the product’s current approval status of approval in your country. Please contact our regional representative for
more information. Subject to change in design and scope of delivery and as a result of ongoing technical development. VISULAS is a registered trademark of
Carl Zeiss Meditec AG or other companies of the ZEISS Group in Germany and/or other countries.
© Carl Zeiss Meditec AG, 2017. All copyrights reserved.