You are on page 1of 2

ATTACHING A DESKTOP CHARGER ADAPTER

Thank you for purchasing the BC-119N


INSTRUCTIONS DESKTOP CHARGER. The BC-119N charges There are 2 desktop charger adapter types D For types requiring the AD-75/AD-88:
a Ni-Cd or Ni-MH battery pack in approx. for the BC-119N. One has a PCB, the other Install the optional AD-75 or AD-88 to the
DESKTOP CHARGER 1–2 hrs., or a Li-Ion battery pack in does not. The non-PCB types require an BC-119N with 4 screws (supplied with the AD-

BC-1 19 N
approx. 2–3 hrs. additional PCB (AD-75 or AD-88). For some 75/AD-88), then attach a desktop charger
Please read these instructions thoroughly versions, the AD-75 or AD-88 is already in- adapter to the BC-119N. See the trans-
before operating the BC-119N. stalled in the BC-119N. ceiver’s instruction manual for an approved
desktop charger adapter.
D For the PCB types: • Installing the AD-75/AD-88
Connect the plugs of an appropriate desk-
CAUTION top charger adapter and the BC-119N, then
installed the adapter with the screws (sup-
R WARNING! To reduce the risk of injury, Make sure battery and charger con- plied with the adapter). For some versions, the
charge only specified Icom Ni-Cd, Ni-MH tacts are always clean, otherwise bat- desktop charger adapter is already installed.
or Li-Ion rechargeable battery packs. teries may not fully charge.
• Installing the PCB type adapter
Other types of battery packs/cases may SAVE THESE INSTRUCTIONS! These
burst, causing damage and personal instructions contain important safety and
injury. operating details for the BC-119N.
Not used
R USE INDOORS ONLY! NEVER expose An appropriate desktop charger adapter See NOTE below
the charger to rain, snow or any liquids. must be purchased separately to charge
NEVER let metal, wire, etc. touch any your Icom battery packs.
internal part of the charger. • Installing the non-PCB type adapter
NEVER incinerate used batteries. This In order to get the maximum life out of your
may cause an explosion. Ni-Cd batteries:
1. Avoid overcharging— batteries must be
NEVER use the charger when it is covered See NOTE below
removed from the charger to stop
by objects which impede heat dispersal.
charging. Batteries should not be
Place the charger in a secure place to charged for more than 15 hours after NOTE: Some of the PCB type desktop
avoid inadvertent use by children. the LED indicator turns green. charger adapters (incl. AD-75/88) do not
AVOID charging in conditions of extreme 2. Use the batteries until they become need connection of the 3-pin connector.
cold (under 10°C; +50°F) or extreme heat almost completely exhausted under The connection is required only for the
(over +40°C; +104°F). Batteries may not normal conditions. installing adapter that is compatible with
charge under extreme temperatures. charging a Li-Ion battery pack.
If your batteries seem to have no
Keep the charger away from TV sets or capacity even after being fully charged,
radios to prevent interference. completely discharge them, then fully
R CAUTION Fix the connector with
R NEVER attempt to charge alkaline or charge them again. If they still do not adhesive tape, etc.
About the 3-pin connector:
dry cell batteries. They may burst causing retain a charge (or very little), new bat-
When you replace the desktop charger adapter
damage and personal injury. teries must be purchased.
from the Li-Ion compatible type to non-compatible type, fix
the 3-pin connector to the bottom of the charger with adhe-
Information (U.S.A. only) Some versions of the BC-119N
The Ni-Cd battery that you have which display the “CE” symbol on sive tape, etc., to prevent catching or touching the 3-pin con-
purchased is recyclable. At the the serial number comply with the nector’s terminals with the adapter’s leads, etc.
end of its life, under various state essential requirements of the
and local laws, it may be illegal to 89/336/EEC directive for Icom, Icom Inc. and are registered trademarks of Icom Incorporated (Japan) in the United States, United
dispose of this battery into the Electromagnetic Compatibility. Kingdom, Germany, France, Spain, Russia and/or other countries.
municipal waste stream. Call 1-800-822-8837 for This compliance is based upon the harmonised
battery recycling options in your area or contact CENELEC generic standard EN50 081-1: 1992
your dealer. and EN50 082-1: 1991. 1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003 Japan
A-6099D-1EX-q Printed in Japan
© 2001 Icom Inc.
CHARGING OPERATION DESKTOP CHARGER ADAPTERS
• Charging example— AD-102 for IC-M1V/M1EURO V D PCB type adapters D Non-PCB type adapters
(AD-75 or AD-88 is required)
CAUTION Charger Charger
Transceiver Battery pack Transceiver Battery pack
Adapter Adapter
The transceiver power MUST be turned
OFF during charging otherwise; IC-F10/F20, IC-W21/X21, AD-28 BP-131/132/157/A
BP-157/A,
IC-M10A/E, IC-2GX series +AD-75 BP-160/174
• The battery will not be charged correctly. AD-66 BP-160/R,
IC-2GX series,
• The battery life may be shortened. BP-174 AD-50
IC-V68/U68 IC-A3/A22 CM-166
The transceiver cannot be used even when the +AD-75
power is ON. Use the spacer, if supplied IC-F30/F40,
AD-67* CM-140/141/142* IC-Z1A/E, AD-51 BP-171/172/173,
with the charger adapter, for IC-F35/F45
IC-W31/W32 +AD-75 BP-180
OPC-515L or charging the battery pack IC-M15,
with/without transceiver. AD-68 CM-138/139/165 IC-T22/T42, AD-56 BP-171/172/173,
CP-17L IC-GM1500
IC-T7A/E/H +AD-75 BP-180
IC-M1,
AD-69 BP-185/186 IC-T8, IC-T81, AD-87
IC-M1EURO BP-198*/199*/200*/L*
IC-A5/A23 +AD-88*
IC-F3/F4/S,
IC-T2H/A/E, *AD-67, AD-88, AD-94 and AD-101 have a temperature
AD-81 BP-195/196/R
IC-F4SR/TR detection circuit for the Ni-MH battery. When the bat-
IC-A4, IC-40S tery’s temperature is outside the charging range, charg-
ing stops and the charging indicator flashes until the
AC adapter IC-4008A/E/M,
IC-4008MKII, AD-89 BP-202 temperature returns to within the range.
(Not supplied with some †
AD-101 and AD-102 are compatible for charging the Li-
IC-446S, IC-40Jr
versions.) Ion battery packs, BP-211 and BP-215, respectively.
IC-F30G/F40G,
IC-F3G/F4G, The BC-119N may be able to be used with future
CHARGE INDICATOR AD-94* BP-209/210*/222
IC-F11/F21/F12/F22, transceivers not listed above. See the transceiver
• Lights orange while charging. IC-V8, IC-T3H instruction manual for the appropriate adapter in-
• Lights green when rapid charging is completed. formation.
IC-F30G/F40G,
- But it is still charging in trickle charge mode when charging Ni-Cd or Ni-MH battery pack. IC-F3G/F4G, BP-209/210*/211†,
• Flashes red when the protection circuit is activated. AD-101*†
IC-F11/F21/F12/F22, BP-222
- Check the power source (voltage) or re-connect the power plug. IC-V8, IC-T3H
- The battery temperature is outside of the charging range. (Ni-MH battery only)
IC-M1V,
AD-102† BP-215†
IC-M1EURO V

NOTE for Ni-Cd/Ni-MH battery packs: ☞ Recommendation for Li-Ion battery


SPECIFICATIONS
The BC-119N rapidly charges a battery packs:
pack to a specified level, not a completed Li-Ion batteries are different from Ni-Cd Dimensions : 115(W)×103(D)×60(H) mm Charging current : 420 mA±10% (rapid charging)
level, to prevent over-charging. Leave the batteries in that it is not necessary to (proj. not incl.) 41⁄2(W)×41⁄16(D)×21⁄4(H) in. 540 mA±10% (rapid charging)
battery pack in the charger for a few more completely charge and discharge them Weight : 200 g; 7.1 oz 670 mA±10% (rapid charging)
Charging temperature range: 840 mA±10% (rapid charging)
hours (up to 15 hours; depending on battery to prolong the battery life. Therefore, 30 mA±10 mA (trickle charging)
10˚C to 40˚C; +50˚F to +104˚F
condition) after the LED indicator turns charging the battery in intervals, and not Electrostatic durability :
Power supply requirement:
green, to charge the battery completely. for extended periods is recommended. 12 to 20 V DC or the specified Air discharge 8 kV
Icom AC adapter (BC-145) Contact discharge 4 kV

All stated specifications are subject to change without notice or obligation.

You might also like