You are on page 1of 1
6 Design 6.1 Practical calculation example 6.1.1 = Calculation of Centrifugal Pumps By help of the example below and the annexed summarised diagrams and tables all the centrifugal pumps can be designed. The tables contain Tuchenhagen specifie valves and pipe fittings. For the calculation of pressure drops in a plant, the conversion principle of the measured friction factor (t) of valves and fittings in metre equivalent pipe length is applied. suction pipe Dative pipe \ Fig, 19 Pressure drop ina plant Pressure drop of the plant rn Myo + Ae Mt Mee aon, ex 8 “2x75 fs 1 Tank outlet 1 Double seat valve ON 65 flow through (seat) 1 Double seat valve ON 65 flow through (housing) 1 Reducer DN 65 18 m equpipe* 25m 9 09 =02m 5 Bends 90" DN 65 x0.6m 10°m pipe DN 65 10.0m riges7 40.2. Page 36 (ang a Pressure drop Hy at / 24 mith DN 65, / I lgn0 = Haigeo Ha geo = 10m - 4m EHy= Hast ya ts 1 Double seat valve ON 50 flow through (seat) =10.5 mequ. pipe 4 Normal valve DN 50 flow through (seat) 2m 10 Bends 90° ON 50 10x0.45 m * 20 m pipe DN 50 20.9 * rages? B= 372m rages J too 40-40) Pressure drop Hy at / 24m¥MDNS0 97,9, 280m 27,44 400m Heat exchanger at 24 mh Spray ball at 24 mi/h 12.0 m som 244m Hyg = 244m