Professional Documents
Culture Documents
01
DATOS
Aguas Aguas
Arriba Abajo
Q (m3/s) 15.668 15.668
b (m) 2.2 2.2
Z 1 1
n 0.014 0.014
S 0.10% 0.10%
Y (m) 1.7735 1.7735
V (m/s) 2.223 2.223
E (m) 2.0255 2.0255
S1 25%
L1 (m) 68
n 0.014
b (m) 3
Z 1
Yc (m) 1.2191
Vc (m/s) 3.0461
Ec (m) 1.692
25.000
Energía (m)
20.000
E
E+hf
15.000
10.000
5.000
0.000
0.000 0.200 0.400 0.600 0.800 1.000 1.200 1.400 1.600
Tirante Y (m)
Y1 = 60.90 cm
Y2 = 50.33 cm
Y3 = 44.84 cm
Y4 = 41.42 cm
Y5 = 39.11 cm
Y6 = 37.46 cm
Y7 = 36.24 cm
Y8 = 35.32 cm
Y9 = 34.62 cm
Y10 = 34.08 cm
3.- Cálculo del Colchón Amortiguador
a) Cálculo de la Curva I
b) Cálculo de la Curva II
QV QV/g
Y (m) A (m2) V (m/s) (m4/s2) Y (m) AY (m) M (m3)
(m3)
0.20 0.640 24.48125 383.572 39.100 0.0979 0.063 39.163
0.28 0.901 17.396808 272.573 27.785 0.1337 0.120 27.906
0.40 1.360 11.520588 180.505 18.400 0.1922 0.261 18.661
0.50 1.750 8.9531429 140.278 14.299 0.2381 0.417 14.716
0.60 2.160 7.2537037 113.651 11.585 0.2833 0.612 12.197
0.70 2.590 6.0494208 94.782 9.662 0.3279 0.849 10.511
0.80 3.040 5.1539474 80.752 8.232 0.3719 1.131 9.362
0.90 3.510 4.4638177 69.939 7.129 0.4154 1.458 8.587
1.00 4.000 3.917 61.372 6.256 0.4583 1.833 8.089
1.10 4.510 3.4740576 54.432 5.549 0.5008 2.259 7.807
1.20 5.040 3.1087302 48.708 4.965 0.5429 2.736 7.701
1.24 5.252 2.9831757 46.740 4.765 0.5591 2.937 7.701
1.40 6.160 2.5435065 39.852 4.062 0.6258 3.855 7.917
1.50 6.750 2.3211852 36.368 3.707 0.6667 4.500 8.207
1.60 7.360 2.1288043 33.354 3.400 0.7072 5.205 8.605
1.70 7.990 1.9609512 30.724 3.132 0.7475 5.973 9.105
1.75 8.281 1.8921165 29.646 3.022 0.7656 6.340 9.362
1.90 9.310 1.6829216 26.368 2.688 0.8272 7.701 10.389
2.36 12.651 1.2384651 19.404 1.978 1.0069 12.738 14.716
3.22 20.019 0.782658 12.263 1.250 1.3318 26.661 27.911
3.73 25.102 0.624164 9.779 0.997 1.5204 38.166 39.163
3.50
3.00
2.50
Tirante Y (m)
2.00
1.50
1.00
0.50
0.00
5.000 10.000 15.000 20.000 25.000 30.000 35.000 40.000 45.000
Curva I (Elev. -
1.2 Tirantes)
1 Curva II (Elev. -
Conj. Menores)
0.8
Tirante Y (m)
0.6
0.4
0.8
Tirante Y (m)
0.6
0.4
0.2
0
3020.00 3022.00 3024.00 3026.00 3028.00 3030.00 3032.00 3034.00
Elevaciones del Fondo del Tanque (m)
Para :
Y1 = 0.275 m Y-1= 0.13365
Y2 = 3.219 m Y-2= 1.3318
Se obtiene :
27.9056 = 27.9113 Diferencia : 0.0057 OK
Donde:
Y2 = 3.219 m
V2 = 0.783 m/s
Altura de Colchón = 3027 - 3025.58 = 1.378 m
Yn = 1.7735 m
Vn = 2.223 m/s
Luego :
3.25022 < 3.40337 OK
0.4*E2 = 1.3001 m
E2 + 0.4*E2 = 4.5503 m
Cota de Colchón: 3024.43 msnm
Profundidad = 2.525 m
Porcentaje de Ahogamiento
%Ahog. = 40%
%Ahog. = 39.23% OK
Lr = 6(Y2-Y1)
Lr = 17.664 Lr = 18 m
Y = - ( 0.20X + 0.012X2 )
1 2 3 4 5 6
X X^2 0.20X 0.012X2 3+4 Elev.
0.00 0.00 0.00 0.00 0.00 3031.58
1.00 1.00 0.20 0.01 0.21 3031.37
2.00 4.00 0.40 0.05 0.45 3031.13
2.50 6.25 0.50 0.07 0.57 3031.01
3.00 9.00 0.60 0.10 0.70 3030.88
3.50 12.25 0.70 0.14 0.84 3030.74
4.00 16.00 0.80 0.18 0.98 3030.60
4.50 20.25 0.90 0.23 1.13 3030.45
5.00 25.00 1.00 0.29 1.29 3030.29
6.00 36.00 1.20 0.41 1.61 3029.97
7.00 49.00 1.40 0.56 1.96 3029.62
8.00 64.00 1.60 0.74 2.34 3029.24
9.00 81.00 1.80 0.93 2.73 3028.85
10.00 100.00 2.00 1.15 3.15 3028.43
PC = 3031.58 m
PT = 3028.73 m
DISEÑO DE RAPIDA ESTACIÓN 0+355.18 - 0+499.1
DATOS
Aguas Aguas
Arriba Abajo
Q (m3/s) 15.668 15.668
b (m) 2.2 2.2
Z 1 1
n 0.014 0.014
S 0.10% 0.10%
Y (m) 1.7735 1.7735
V (m/s) 2.223 2.223
E (m) 2.0255 2.0255
S1 27.5%
L1 (m) 100
n 0.014
b (m) 3.5
Z 1
Yc (m) 1.1322
Vc (m/s) 2.9875
Ec (m) 1.5871
20.000
Energía (m)
15.000 E
E+hf
10.000
5.000
0.000
0.000 0.200 0.400 0.600 0.800 1.000 1.200 1.400 1.600
Tirante Y (m)
Y1 = 48.25 cm
Y2 = 39.43 cm
Y3 = 35.29 cm
Y4 = 32.94 cm
Y5 = 31.47 cm
Y6 = 30.52 cm
Y7 = 29.88 cm
Y8 = 29.44 cm
Y9 = 29.13 cm
Y10 = 28.92 cm
3.- Cálculo del Colchón Amortiguador
a) Cálculo de la Curva I
b) Cálculo de la Curva II
QV QV/g
Y (m) A (m2) V (m/s) (m4/s2) Y (m) AY (m) M (m3)
(m3)
0.20 0.740 21.172973 331.738 33.816 0.0982 0.073 33.889
0.28 1.038 15.092595 236.471 24.105 0.1342 0.139 24.244
0.40 1.560 10.04359 157.363 16.041 0.1932 0.301 16.342
0.50 2.000 7.834 122.743 12.512 0.2396 0.479 12.991
0.60 2.460 6.3691057 99.791 10.172 0.2854 0.702 10.874
0.70 2.940 5.3292517 83.499 8.512 0.3306 0.972 9.483
0.80 3.440 4.5546512 71.362 7.274 0.3752 1.291 8.565
0.90 3.960 3.9565657 61.991 6.319 0.4193 1.661 7.980
1.00 4.500 3.4817778 54.552 5.561 0.4630 2.083 7.644
1.10 5.060 3.0964427 48.515 4.945 0.5062 2.561 7.507
1.17 5.441 2.8798527 45.122 4.600 0.5344 2.908 7.507
1.27 6.082 2.5760941 40.362 4.114 0.5803 3.530 7.644
1.40 6.860 2.283965 35.785 3.648 0.6333 4.345 7.992
1.53 7.727 2.0277596 31.771 3.239 0.6894 5.327 8.565
1.60 8.160 1.920098 30.084 3.067 0.7163 5.845 8.912
1.70 8.840 1.7723982 27.770 2.831 0.7574 6.695 9.526
1.75 9.153 1.7117466 26.820 2.734 0.7758 7.101 9.835
2.11 11.803 1.3274421 20.798 2.120 0.9210 10.870 12.991
2.36 13.831 1.1327976 17.749 1.809 1.0217 14.131 15.940
3.38 23.231 0.6744343 10.567 1.077 1.4124 32.812 33.889
3.73 26.967 0.5809988 9.103 0.928 1.5443 41.645 42.573
3.50
3.00
2.50
Tirante Y (m)
2.00
1.50
1.00
0.50
0.00
5.000 10.000 15.000 20.000 25.000 30.000 35.000 40.000 45.000
Curva I (Elev. -
Tirantes)
1
Curva II (Elev. -
0.8 Conj. Menores)
Tirante Y (m)
0.6
0.4
Tirante Y (m)
0.6
0.4
0.2
0
2986.00 2988.00 2990.00 2992.00 2994.00 2996.00 2998.00 3000.00 3002.00 3004.00 3006.00
Elevaciones del Fondo del Tanque (m)
Para :
Y1 = 0.211 m Y-1= 0.1035
Y2 = 3.295 m Y-2= 1.3812
Se obtiene :
32.0394 = 32.0421 Diferencia : 0.0027 OK
Donde:
Y2 = 3.295 m
V2 = 0.700 m/s
Altura de Colchón = 2990.3 - 2988.97 = 1.33 m
Yn = 1.7735 m
Vn = 2.223 m/s
Luego :
3.31996 < 3.35537 OK
0.4*E2 = 1.3280 m
E2 + 0.4*E2 = 4.6479 m
Cota de Colchón: 2987.68 msnm
Profundidad = 2.623 m
Porcentaje de Ahogamiento
%Ahog. = 40%
%Ahog. = 39.32% OK
Lr = 6(Y2-Y1)
Lr = 18.50 Lr = 19 m
Y = - ( 0.20X + 0.011X2 )
1 2 3 4 5 6
X X^2 0.20X 0.011X2 3+4 Elev.
0.00 0.00 0.00 0.00 0.00 2999.34
1.00 1.00 0.20 0.01 0.21 2999.13
2.00 4.00 0.40 0.04 0.44 2998.90
3.00 9.00 0.60 0.10 0.70 2998.64
4.00 16.00 0.80 0.17 0.97 2998.37
5.00 25.00 1.00 0.27 1.27 2998.07
6.00 36.00 1.20 0.38 1.58 2997.76
7.00 49.00 1.40 0.52 1.92 2997.42
8.00 64.00 1.60 0.68 2.28 2997.06
10.00 100.00 2.00 1.07 3.07 2996.27
12.00 144.00 2.40 1.54 3.94 2995.40
13.00 169.00 2.60 1.80 4.40 2994.94
14.00 196.00 2.80 2.09 4.89 2994.45
18.35 336.72 3.67 3.59 7.26 2992.08
PC = 2999.34 m
PT = 2992.07 m