Cables: About This Chapter
Cables: About This Chapter
6 Cables
This chapter describes various optical fibers and cables used on the equipment.
Power cables need to be produced on site. The power cables are made of DC connectors,
single cord end terminals, and wires. Figure 6-1 shows the appearance of the power cable.
Table 6-1 provides the technical specifications of the power cable.
2.5 mm2 Electronic/Electric wire, 600V, Maximum current of the single pin: 30.0
power cable UL3386, K, 14AWG, blue/ A
and terminal black Applicable cable specification: 2.5-4
mm2 (with cord end terminals), 4-6 mm2
(without cord end terminals)
4 mm2 Electronic/Electric wire, 450 Maximum current of the single pin: 30.0
power cable V/750V, H07Z, K, 4 mm2, A
and terminal blue/black Applicable cable specification: 2.5-4
mm2 (with cord end terminals), 4-6 mm2
(without cord end terminals)
NOTE
The technical specifications in the Table 6-1 are provided only for reference and those of the delivered cables
prevail.
Indoor DC power cables are used to provide external power supplies for the device.
Figure 6-2 and Figure 6-3 show the appearance of the DC power cable used for an indoor
device and Table 6-2 lists the technical specifications of the DC power cable.
NOTE
The technical specifications in the Table 6-2 are provided only for reference and those of the delivered cables
prevail.
Flame-retardant CM
rating
Note:
1. The naming rule of the power cable model is: model of connector 1-model of the cable
material-model of connector 2.
2. The specifications of AC power cables are different in different countries and regions.
The AC power cable that complies with the China national standard is used as an example
here.
The ETH/OAM management interface, integrating the Ethernet NM interface and console
interface, uses the RJ-45 connector. Table 6-8 lists the functions of connector pins.
7 Unspecified
1 Unspecified
2 Unspecified
6 Unspecified
7 Unspecified
8 Unspecified
The ETH/OAM interface can connect to straight-through and crossover cables in autosensing
mode. 6.6.1 Ethernet Cables shows Ethernet cables.
Console Cables
For devices with ETH/OAM interface, there is no independent CONSOLE interface on the
panel(Except NE08E-S9). For An ETH/OAM interface that functions as the Console interface
uses Console cables to ensure communication between an device and the NMS. As Table 6-5
and Table 6-6 shown, there are differences between ETH/OAM interface and standard
CONSOLE interface, thus a Console cable consists of a RS-232 serial cable and a serial
adapter cable, as shown in Figure 6-6.For NE08E-S9, whose main control board has
independent CONSOLE interface, thus the serial cable can directly connect with CONSOLE
interface.
8 1 1 8 1
P os.5 P os.9
X1
X2 X3
X4
S e ria l a d a p te r c a b le S e ria l c a b le
Table 6-7 lists the pin assignment of the serial adapter cable.
Table 6-8 lists the pin assignment of the RS-232 serial cable.
Console Cables
A console interface uses RS-232 serial cables to achieve communication between an NE
device and an NMS. Figure 6-7 shows the appearance of console cables.
Table 6-9 lists the pin assignment of the RS-232 serial cable.
Structure
Figure 6-8 shows the structure of the alarm input/output cable.
8 W
X1
Pin Assignment
Table 6-10 lists the pin assignment of the alarm input/output alarm cable connector.
Technical Specifications
Table 6-11 lists the technical specifications of the alarm input/output cable.
Item Specification
Cable type Twisted-Pair Cable, 100 ohm, Category 5e, 0.52 mm, 24AWG, 8 Cores, 4
Pairs, PANTONE 430U
The external clock cables can be connected to the CLK, and TOD interfaces on an device.
Structure
Figure 6-9 shows the structure of the RJ45 connector used on the external clock cable.
Pin Assignment
The external clock cables must be made on the equipment installation site. When the CLK
interfaces are used as external clock interfaces, the pin assignment of the RJ45 connector is as
listed in Table 6-12; when the TOD interfaces are used as external time interfaces, the pin
assignment of the RJ45 connector is as listed in Table 6-13.
Table 6-12 Pin assignment of the RJ45 connector (external clock mode)
Connector Color Relation Description
Pin
6 Green Unspecified
8 Brown Unspecified
Table 6-13 Pin assignment of the RJ45 connector (external time mode)
Connecto Color Relation Description
r Pin
1PPS + Time DCLS Mode
Information Mode
Technical Specifications
Table 6-14 and Table 6-15 lists the technical specifications of the external clock cable.
Item Specification
Number of Eight
cores
Item Specification
Number of Eight
cores
Structure
Figure 6-10 shows the structure of the 120-to-75-ohm clock bridging cables.
W5 H e a t-s h rin k tu b e W2
8 A
1 W3
X1
W4
30m
Pin Assignment
Table 6-16 lists the pin assignment of the clock bridging cable connector.
X1.2 White
X1.5 White
X1.6 White
X1.8 Brown
Technical Specifications
Table 6-17 lists the technical specifications of the clock bridging cables.
120-ohm cable Twisted-Pair Cable, 120 ohm, SEYVP, 0.4 mm(0.02 in.), 26AWG,
type 4Pairs, Pantone 430U
A network cable with a shield layer is a shielded cable and that without a shield layer is a non-
shielded cable.
The Ethernet service interfaces on the equipment are adaptive to the straight-through cables
and crossover cables. Hence, you can connect either type of the network cables to the Ethernet
service interfaces as required.
Ethernet cables need to be made on site.
Structure
Figure 6-11 shows the appearance of the shield layer.
RJ45 connectors are used at both ends of a network cable. Figure 6-13 shows an RJ45
connector and Figure 6-14 shows the structure of the network cable.
W 8
8
1 1
X1 X2
NOTE
For a crossover cable, pins 1 and 2 of the RJ45 connector at one end must be cross-connected to pins 3
and 6 of the RJ45 connector at the other end respectively.
Pin Assignment
Table 6-18 and Table 6-19 list the pin assignment of the network cable connector.
straight-through Cable
Technical Specifications
Table 6-20 lists the technical specifications of the shielded cable.
Number of Eight
cores
Item Specification
Number of Eight
cores
At one end of the 75-ohm 16 x E1 cable, the Anea96 connector is used to connect the 75-ohm
E1 electrical interface on the board; the other end is connected to the digital distribution frame
(DDF). Make the connector as required on site.
Structure
Figure 6-15 shows the appearance of the 75-ohm 16 x E1 cable and Figure 6-16 shows the
structure of the cable.
X1 A
V ie w A P o s.9 6
C a b le C o n n e cto r, A n e a , 9 6 P IN ,
F e m a le C o n n e c to r
P o s .1
Pin Assignment
Table 6-22 lists the pin assignment of the 75-ohm 16 x E1 cable connector.
1 Tip 1 R0 25 Tip 2 T0
2 Ring 26 Ring
3 Tip 3 R1 27 Tip 4 T1
4 Ring 28 Ring
5 Tip 5 R2 29 Tip 6 T2
6 Ring 30 Ring
7 Tip 7 R3 31 Tip 8 T3
8 Ring 32 Ring
9 Tip 9 R4 33 Tip 10 T4
10 Ring 34 Ring
11 Tip 11 R5 35 Tip 12 T5
12 Ring 36 Ring
13 Tip 13 R6 37 Tip 14 T6
14 Ring 38 Ring
15 Tip 15 R7 39 Tip 16 T7
16 Ring 40 Ring
17 Tip 17 R8 41 Tip 18 T8
18 Ring 42 Ring
19 Tip 19 R9 43 Tip 20 T9
20 Ring 44 Ring
22 Ring 46 Ring
24 Ring 48 Ring
50 Ring 74 Ring
52 Ring 76 Ring
54 Ring 78 Ring
56 Ring 80 Ring
Technical Specifications
Diameter of the shield 12.4 mm(0.49 in.) - 1.6 mm(0.06 in.) - 0.26 mm(0.01 in.)
layer - diameter of the
internal insulation
layer - diameter of the
internal conductor
Number of cores 32
Available length 5 m, 10 m, 15 m, 20 m, 25 m, 30 m, 35 m, 40 m, 45 m, 50 m
16.40 ft.,32.80 ft.,49.21 ft.,65.62 ft.,82.02 ft.,98.42 ft.,114.83 ft.,
131.23 ft.147.64 ft.,164.04 ft.
Structure
Figure 6-17 shows the appearance of the 120-ohm 16 x E1 cable and Figure 6-18 shows the
structure of the cable.
X1 A
V ie w A P o s.9 6
C a b le C o n n e cto r, A n e a , 9 6 P IN ,
F e m a le C o n n e c to r
P o s .1
Pin assignment
Table 6-24 lists the pin assignment of the 120-ohm 16 x E1 cable connector.
2 Blue 26 Orange
3 White R1 27 White T1
4 Green 28 Brown
5 White R2 29 Red T2
6 Grey 30 Blue
7 Red R3 31 Red T3
8 Orange 32 Green
9 Red R4 33 Red T4
10 Brown 34 Grey
11 Black R5 35 Black T5
12 Blue 36 Orange
13 Black R6 37 Black T6
14 Green 38 Brown
15 Black R7 39 Yellow T7
16 Grey 40 Blue
18 Blue 42 Orange
19 White R9 43 White T9
20 Green 44 Brown
22 Grey 46 Blue
24 Orange 48 Green
50 Brown 74 Grey
52 Blue 76 Orange
54 Green 78 Brown
56 Grey 80 Blue
Technical Specifications
Cable Trunk Cable, 120 ohm, 16E1, 0.4 mm(0.02 in.), Anea 96F,
120CC32P0.4P430U(S), +45deg
Cable type Twisted-Pair Cable, 120 ohm, SEYVP, 0.4 mm(0.02 in.),
26AWG, 32Pairs, Pantone 430U
LC/PC connectors are used at both ends of the optical fiber shown in Figure 6-19. For an
optical fiber that connects an optical port on an NE device to an optical port of another type
on the peer device, an LC/PC connector is used at one end and a connector of another type is
used at the other end. Table 6-26 lists the common optical connectors.