You are on page 1of 4
EXCEL CALIBRATION PVT.LTD. <2 ISO/IEC 17025 Accredited Calibration Lab by NABL India Excellence im Metrology ..... id ECPL Plot No. 5-A/9, 1st Floor, Road No.1, IDA Nacharam, Boss — Hyderabad - 500 076. Telangana State. CALIBRATION CERTIFICATE Customer Details: [ULR No: CC242419100001462F Page 1 of 4 M/s. Avian Test Lab Pvt. Ltd, [certificate No ECPL/19/67/11828-01 ‘Mukunda Bhavan, Six Mile GS Road, [calibration Date: 30/12/2019 Guwahatl-781022. Due Date 29/12/2020 SRF No. L828 bate 30/12/2019 Details of DUC: [Environmental Conditions : Description Multi Function Calibrator with Current Coil Temperature: -2542°C Make Zeal Humility 60 215% IModet 2MMEFCS.5,2MCC Calibrated At ©: LAB s1.No 201812399,21809-01 Visual Inspection: OK ID No Range Enclosed Format No ECPL/F/042 al Procedure ECPL/OSP/19/€T/15,29 ‘Standards Used for Calibration S.No] Nomenclature Make/Model | Sl. No CertificateNo | Validity 1 4 Digit Multimeter Fluke/@508a | 334470520 _|cc202019000000815F| 17/09/2020 z ‘6% Digit Multimeter Fluke/ 8846 saaaoos | cr/ecat/sos42/2_| 02/05/2020 3 | Multi product Calibrator Fluke/5522a_[~ 3ao1903 | _cr/PcaL/s0542/1_| 13/05/2020 4 50 Trun Current Coil Fluke/s500A_| _20082260_| _cr/Pcal/s0s43_| 07/05/2020 5 Dc Shunt Vaiseshika /9410| 6348 ee a 25/06/2021 é Current Shunt Wisri7— | ecP\yeT/23 _[€C202019000000739F| 0970872020, isomer con ate pale Sten eel 2. All Results Reported are valid at the time of and under the stated conditions of measurements. 3. Masters/ Equipment Used for Calibration are Traceable to National / international Standards. rote ae saee ipa Sas atc cer eee saaearna wv ennicna alos ex end eRe tac FD eu ctesaees teas ues cu cope Coe Calibrated by Authorised Signatory an aes (canines) : eae) Ena face EXCEL CALIBRATION PVT. LTD. Excellence im Metrology ISO/IEC 17025 Accredited Calibration Lab by NABL India Plot No. 5-A/9, 1st Floor, Road No.1, IDA Nacharam, Hyderabad - 500 076. Telangana State. LR No: 6c242419100002462F Calibration Results cen no: Eevys/er/se2601 ase o 2086 ‘eco Tecical cataton Deviation ]_aeanromae sino | rarameter| range | uc Resding | sroReading | Devatin | tinerontt z Toon av tenons a] a3 av] —o00055_ nV z eomy (20000 20.0581 “2.90681 | 000000 3 ‘oom 7001050 =a.0050 000 az 0000 0012 “aia 00072 5 20000 —v | 00059 —v | Bammoss_v_|-oomon60_v a 2 [00% fomus ——[oomous | ooo 7 ‘iam [1.000746 | ~a.co00r¢6 | ~a.000072 A 2000 2000524 4.0005 | 9an0s0 3] oc votage | 2ov [30,000 ioanoe “2.0005 | — econo 20 18000 8006 3.0005 —| anor a 20000. a00s02 =30050_—| — ano a7 row {ioe ooo “20125 | amo 2 90060 005100 “Bass 0016 ra odo ‘0080 ano | —Boo020 = omy [50000 soo.zet “oat 0015 ra 00.00 00.2378 a78 027 7 299.00 299.501 “24501 0.030 ro 0.000 — nv] — 100096 md] 0096 mi] 008s a weomy [2000 200188 ae 0.0058 2 rood soos cam 0005 a swoon [Fagan “205 052 z 2000 —v | omors0 —v | —aacora0_v | on0s_v Fa av [0000 000821 =Bavoea1 | — aceon zm 000 1729682 000358 | —oos2 25] Acvotase 20000 199758 ozs | 0.00056 26] eso | 2ov | “s00000 soo017 “2.00147 1.0029 a 000 i006 ~aso2i6 052 Fa 20000. 199954 04s 2.0000 Fa voy [Tito000 ‘oon ~a.0022 020 = 80000 00038 8.0038 036 BH | a.0 29932 oa 0.000 2 sooo | sco00 Soon36 038 040 = 229.00 298530 0070 020 * 30000 av] —s00075 mv] aos mv] cs mv 35] Acvotage | sep my. [28000 200152 0182 0058 a] eco ‘oom ‘ooazrr “aor 0028 7 0.00 90022 ET 0052 cottrted by storsedSgstory Qe Franses, ae Praveen Kam (caravan Engines (managing Director) 92 Eno EXCEL CALIBRATION PVT. LTD. Excellence im Metrology ISO/IEC 17025 Accredited Calibration Lab by NABL India (CPL Plt No, 5-A/9, tt Floor Road No.1, DA Nacharam, ir Reson Hyderabad - 500 076. Telangana State. LR No: Cc2azai9100001462F Calibration Results on. No: EnV OL page :30t4 sto |ronmewr| tung | ove netne | sronmane | Qevaton | tment a 5 ET 2 av [te09 [tos — [ens | coos 2 ison ——[ srs | otnons | soo a 2000 ‘sa aooiss | —oorse 2 20 |Fioete0——| omnes panies —| Boo 3] Acvotoge ‘0000 ——| “oon coamani—| boost a] ame 200 {39967 cone om ra wv |“ seoeso——| oar ~aom1 | ono ra ‘i5a0 [roa som 038 a oa 935 oor 0 2 recov [sonoo Sono3e “oo ow 3 9800 298917 oo oat $0 tbo) maaan mA Boe an om mA a ama | 1aoos—— [teres [comes — [oan 3 sono ——|-tsot99 ——[omoie0 [noms 3 20000 | 19600 | ~oonioas —| —oaonie Ea zoma_ | tomo —— | saseer0 | como | — oo % ‘oan ——|-i7sest00 | ocpeao | —oonis sé sa000 [20051 | om | 00018 7] occuren| 250m [atom ——|-ss9s02 ose oo = iow ——[-7os7503 0337 0 : 39 200.00 0.0425 0.022 a 2o10ma [00 2 3658 om a iipoco ——|stoss “aa O20 a oat —E-[- 100003 —A | Sa0oma_n | coma 3 10 [0600 [stort [ania | — os a $ai00 | -san1 | const —| noose a aatbo) mA ones ma] — omo2s wn] —oa0018 aa a ama [1mm —"~ | 035980 moat | — oman 7 asom [uso comms? —| —aooit ease 2005 39 a | SOx" 20m [incom —— | a99654 nas | —oaoe * [Cite isis prom ooit 7 2000 200058 “3053 —| ons 7 o-ama | “fons00——| 285630 nso | —00ss 2 a0 [570 50 on catia by tore Seaton Bor Keon. samy 1 raven mar (camaton ee (manag De) Mee EXCEL CALIBRATION PVT. LTD. CS Excellence im Metrology ..... ee) ISONEC 17025 Accredited Calibration Lab by NABL India <4 CPL Plot No. 5-A/9, {st Floor, Road No.1, IDA Nacharam, coz Semen Hyderabad - 500 076. Telangana State. LULR No: €C242419100001463F ibration Resul (0-200 [000.00 999.643, (0.357 (070 ‘AC Current 1800.00, 1800.125) 7.25, 126, @ 50H 4.0000 A | 1.00702 a -0.00702 a} —o.00070 0 010 [S.0000. 5.00124 “2.00124 0.0075, 3.8000. 9.90257, 6.00257 ‘015 (0.20000 ma] 0.199951 mA] 0.00008 ma] —o.o0016 mal 02ma_ [1.00000 0.980745 (0.00026 0.00080. 1.80000 1.800878 0.00088 ‘0.0014 2.0000 1.99856 000144 0.0016, mn 020ma [10.0000 3.99713, 0.00287 0.0080 35 18.0000 17:99626, ‘0.00374 ‘018 85] sccunent 20.000, 20.0081, 2.004 ‘0.016 S| Scone | °200ma [100.00 98.9628 0.0372 0.066 38 180.000, 179.9839, o.0161 012 a 200.00 200.081, 0.081 0.3 0) ‘0-200 | 060.00, 999.653, 0347 0.70 31 1800.00 700.185 7018s 126 2 40000 A | 100714 a | —-o0071¢ a | —a00070 a 93 010 [5.0000 5.00169, 00168 (0.0075, 9.9000, 9.90784 2.00284 ‘0.015 3% 450 ve | 45.0035 wz] 0.0015 te | 0.017 He 36 500. sao | 0.0004 0.019 7 60.0 60.0087 0.0087 ‘0.022 foam per) | 029894 300.0011 2.0011 (0.037 3 5000 500.030 0.030 019 300) 999.0 999.185 0.185, 037 cali sie | range |Meterrdg with stO[Meter rg with DUC] Deviation | Measurement Colt colt Observed | Uncertainty) or 10 ev | ana" ave ad Vass] 302, = 100.1 100.4 03 155 303] occurrent | 0-100 [~~505.2 500.7 05. 735 308, 901.6 S015 02 7357, 305) 1001.8 3002.4 =06 35.08 306, (i a 02 019 V 307, 1002 300.8 oz 078 308] Accurent | 0-100 [soa SOL7 oa 77. 108 2015 9019 oa 7.88 110) 1091s 1002.3 a4 15.38 Callrated by ‘Authorised Signatory Ksamyel NN Praveen Kumar (Calibration Engineer) (Managing Director) ue plindia,

You might also like