TEST/ INSPECTION CERTIFICATE
ceumaited
et
Description + Welding Machine Model. + CST 280
Environmental Condition
‘Arab-Cal certifies that the above instrument has been tested as per manufacturer’s/Arabcal procedure (Ci/01/wa) and the test
results are given below.
‘This certificate is issued in accordance with the requirements of ISO 9001:2008 and may not be
reproduced other than in full, except with prior written approval of the issuing laboratory
‘Test Results
Set A Minimum A’ ‘Maximum A ‘Max Error A
50 438 50.9 03
100 98.2 102.5 25
200 195.8 197.8 42
280, 278.2 282.6 26
Comments
“The machine was tested using various combinations of “Current Settings” and “Types of Welding” as selected on the front
control panel. The results obtained were satisfactory. Measurements above were taken with a fixed Current Settings. The
‘normal welding position was used and adjusted to show the minimum and maximum Current obtained,
Serial Number ‘Traceable To
Digital Clamp Meter 139744KGV NPL F
Test Date + 10 December 2015 Due Date (Recommended) £09 December 2016
Tested by
certified by
Page 1of 1