ALSTOM RELAY

PRODUCT RANGE

Jakarta
February 2014

GRID
Substation Automation Solutions
Offer

Transmission & Primary Distribution


From 10 kV to 1000+ kV

MU Agile AMU

MiCOM P40 Agile

MiCOM & IEDs Control Systems Projects & Engineering Support


© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
A Proud History
M O DE L
KC G G 140 No

S Y S M od e l N o .
K C G G 14 0 M
F E D C B A 9 8 7 6 5 4 3 2 1 0

A L AR M T RIP

F + - 0

Historical milestones In
P h+
A Vx
Hz
V

CDG MCGG K P14x

• 1949 - Relay development started in Stafford


• 1952 - 1st Induction Disc overcurrent relay [CDG]
• 1960 - Stafford site opened

• 1982 - 2nd generation of digital protection (MIDOS MCGG) Agile

• 1999 - 3rd generation of numerical products (MiCOM)

• 2002 - 1st PACiS Digital Control Sys


commissioned in UK
• 2007 - Certification Labs. receive
ILAC accreditation

• 2009 - UCA International


accredit for IEC 61850
conformance testing

1918 1968 1989 1998 2004 2010


English GEC ALSTOM AREVA ALSTOM
Electric GEC GRID
ALSTHOM T&D T&D

Almost 100 years experience


© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject P3
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
ALSTOM GRID Protection Covers all Areas of your
Power System
Generation
P940
Transmission
P640
P340 P140 P340
P740 P440 P540 P140

P640 Industry

P640
P240

P640
Distribution P140
C264P
P140
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Substation Automation Solutions
Portfolio and offering

Numerical Protection Relays Digital Control System


MiCOM Alstom Px40 DS Agile incl. C264

MiCOM Px40 Agile Substation Digitalization


Feeder Management DAP Server (ASAT)

Digital Protection Relays


Control Switches
MiCOM Alstom Px40-9.2

P847 Phasor Measurement Unit Legacy DCS


Mx70 Measurement SPACE2000, PSCN, PACiS
Electromechanical Conventional Control
Hinged Armature relays Protection panels

© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
MiCOM Alstom
Complete Protection Range

Px90 C264P
Feeder
Interfaces &
One-Box
Accessories
Solution • Comprehensive Range
P840 P140 • Fault Analysis Tools
Autoreclose Feeder
Relays & PMU Management • Programmability
Relays • Customisation
• Instrumentation
P740 P240 • Self Diagnostics &
Busbar
Protection
Universal Motor • Commissioning Tools
Protection
Relays • Communications
• Bay Monitoring & Control
P640 P340
Transformer Generator
Protection Protection
Relays Relays
P540 P440
Line Distance IEC61850, Cyber Security
Differential Protection
Relays Relays Redundant Ports

© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
MiCOM S1 Agile

Device Configuration
• Setting file and logic creation, editing and transfer to and from the IEDs.
• Management of events and disturbance records

System Explorer
• Displays a virtual system of the
managed devices.
• System is graphically displayed as
tree with different nodes referred
as elements (system, substations,
voltage levels, bays, etc.,)

© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Product
Selection

© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Overcurrent & Voltage Feeder Relays
Selector
START No
P14NB
with Auto Reclose
None Yes
Rear With Downed
Non Directional Conductor
Ethernet Port(s) Overcurrent Only ?
Required? Detection ?
Yes P14NZ
No (SEF CT only)
Single No Auto Reclose

Voltage Inputs Yes Check Yes


Dual Synchronism P94VP
Only ?
Redundant required?
No
No P94VB

P14x Auto Reclose No


See P14x Advanced and Fault Locator P14DB
Feeder Management Required ?

Yes P14DZ
(SEF CT only)

With Downed Yes


Conductor
Detection ?
P14DL
No
Product selector - 08.2010 - P 14
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Advanced Feeder Management
Selector
START
P341
With voltage vector Yes Distributed Generation
Shift & dynamic line rating
Interconnection
?
No Feeder Protection

One box solution Yes C264P


With mimic diagram Feeder relay with
? No Integrated bay control

8 binary inputs Autoreclose


No
+8 relay contacts required?
Sufficient ? Yes
P145
Yes No Function keys for Yes Feeder Management
control & test operations Relay with autoreclose,
Required? No Check synchronism
& Function keys

P141 Check
Feeder management Synchronism
relay Required?

P143
P142 Yes
No Feeder management
Feeder management
Relay with autoreclose
Relay with autoreclose
& check synchronism
Product selector - 08.2010 - P 15
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Motor Protection

No P241
START Motor Management
relay
Yes
Function keys for
Is motor rated
control & test operations
power ≤ 1 MW ? Required?

P242
No Motor Management
(> 1MW) Yes relay

No
With differential
Protection?

Yes

P243
Motor Management
Relay with Differential
Product selector - 08.2010 - P 16
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Generator Protection

START No With Voltage vector P341


With
Small generators Yes underimpedance, Shift & Dynamic
(<1.5MVA) loss of field Line Rating Yes
Protection? P14DG
No
No Yes

P342
Yes No
Yes
Medium size generators Yes 100% stator
(1.5
(1.5-10MVA) or back-up
up protection With differential? earth fault, pole slipping P343
for large generators dead machine?

No
No P346
Economy model

Yes
Large Generators Yes With 100%
(>10MVA)
stator earth fault via low P345
frequency injection?

With differential & 2x Yes


No neutral voltage inputs for earth
fault and interturn P344
Yes protection?
With 100% stator
earth fault, pole slipping, No P346
dead machine ?
(With differential &
1 neutral voltage input
No for earth fault)

Product selector - 08.2010 - P 17


© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Distance Protection
START

Quad Typical Mho


Characteristic
Preference?

Sub-cycle No
Distance required?

Yes
Sub-cycle
Sub cycle Distance Yes Single-Pole
Required? Tripping required?
Yes

No Dual Circuit
Yes
Breaker Feeding No
Yes Arrangement?
Single-Pole
Tripping required? P446
Sub-cycle dual CB No
quad/Mho distance
No P445
Relay with single-pole
Economy distance
autoreclose
for Subtransmission
8 Opto-inputs
Opto inputs & No 16 Opto-inputs
Opto inputs & P443 & Distribution
14 output contacts 21 output contacts Sub-cycle quad/mho
Sufficient? Sufficient? Distance relay with
No Single-pole A/R
Yes Yes

P441 P442 P444


Full-Scheme quad. Full-scheme quad. Distance relay with
Distance for 3 Pole Distance relay with Single pole A/R and
Single pole Recloser Extended I/O
ProductTripping
selector - 08.2010 - P 18
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Line & Cable Differential

START
Yes
More than 16 digital inputs Dual CB
and 14 output contacts? configuration?

Yes
No No

P544 Yes
Dual CB Differential with Compatible with
Optional Distance SDH/SONET networks? P545
Differential / Distance
With Extended Binary I/O
P546
Dual CB Diff. / Distance No
Yes
With Extended Binary I/O

Yes
With IEC61850 and More than 16 digital inputs
P541 Function Keys? and 24 output contacts?
Economy Model

No
No No
With Auto Reclose? P543
Yes
No With Voltage Inputs, Differential with
Yes Optional Distance Optional Distance
Protection?

P542
Product selector - 08.2010 - P 19
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Phase Comparison Protection

START
Yes
Application Requires
Distance Protection?

No

Yes
With IEC61850?

P547
Advanced Model Phase
No Comparison with Distance
in 80TE case
Yes
With Function
Keys?

No

P547 No
Phase Comparison with
Yes
More than 8 digital inputs
8 binary inputs &
and 8 output contacts?
8 relay contacts in
40TE case

Product selector - 08.2010 - P 20


© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Transformer Protection

START
Is any winding 2 winding 3 winding Is any winding Yes
Supplied by more Supplied by more
Type of Transformer?
than 1 Circuit than 1 Circuit
Yes Breaker? Breaker?

No No
3 phase Auto Transformer
Voltages required P642 P643 P645
for measurement, protection, Transformer Protect.
Directionalising, For 2-End Schemes
records? No

With or without
With
Yes
Tertiary winding?

P643
Without
One

Is any winding
Dual Breaker feeding Yes P645
Supplied by more
One or both sides of Transformer Protect.
than 1 Circuit
transformer? For up to 5 Ends
Breaker?

Both No

P643
P645 Transformer Protect.
For up to 3 Ends
Product selector - 08.2010 - P 21
© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Busbar Protection

Low impedance START


(Biased) High impedance
Technology
Preference?

3 or Economy P14*
How many more Distribution Numerical Yes Feeder Management
Discrete protection Scheme Relay(s) Relay Used in High
Zones? Required? Impedance mode
with Varistor
1 or 2 P14*
Feeder Management No
Relays Used in Interlock
(Blocking) Scheme Current
Pickup MCAG34
Number of feeder, Preferred
Coupler, and section Operating High Impedance, Current
breakers principle Calibrated Electro-
More Mechanical Relay
than 18
Up to Voltage
18 Pickup

P74* Scheme MFAC34


P746 High Impedance, Voltage
Busbar Differential for P741 Central Unit
Calibrated Electro-
Small Schemes P742 Peripheral Unit Mechanical Relay
P743 Peripheral Unit

Product selector - 08.2010 - P 22


© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Autoreclose & Breaker Fail

START
P842
UK Mesh Corner Yes
Mesh corner Autoreclose
Application ? Scheme for Three Pole
Tripping

No

No Dual Circuit Breaker Yes


Configuration ?

16 opto-inputs
opto inputs and No
14 output contacts
sufficient?

Yes

P841 model A P841 model B


Single CB control, reclose, Model for dual breaker,
Check synchronising and ring bus, and breaker
back-up protection and a half feeding

Product selector - 08.2010 - P 23


© ALSTOM 2012. All rights reserved. Information contained in this document is provided without liability for information purposes only and is subject
to change without notice. No representation or warranty is given or to be implied as to the completeness of information or fitness for any particular
purpose. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
www.alstom.com
www.alstom.com/grid/sas

GRID