NPTS/BM.40 Sé bién bin: _476/NPTS2/RL CONG TY DICH VU KY THUAT TRUYEN TAI DIEN EVNNPT POWER TRANSMISSION SERVICE COMPANY NPTS TRUNG TAM DICH VY KY THUAT 2 TECHNICAL SERVICE CENTER 2 BIEN BAN THi NGHIEM BAO VE KHOANG CACH (Distance protection Test Report) Tén dy an (Project):Tram bién dp 220kV KonTum Vj tri Kip dat (Site): Ne’n 16 112 Tén thiét bi(Model): SEL 311C ‘86 ché tao(Serial NY): 1143600156 Hang sin xudt(Manufacturer): SEL Kiéu(type): F21 Déi tugng bao vé (Prorection Object): Ngan 16 112 Thiét bj thi nghigm (Test equipment): Omicron C256 Noi thi nghigm (Location test): Tram 220kV KonTum_| Ngay thi nghigm (Test dare): 23/03/2019 Tis6 bién dign ap | Line V7 ratio: N0N3—0.11N3 | Ti s6 bién dong dién 1200/1 (VI ratio) Bus VI ratio: \ON3 - 0.11/N3 (CT ratio) : Ly do thi nghiém (Purpose of test): Thi nghiém dinh ky 2019 Phiéu chinh dinh (Sesting Order): A3-35-2018, ngay 29 thang 11 nim 2018 ‘Cie chife ning duge kiém tra va cai dit: Kiém tra (Tested and set functions) (Tested) 1, Kiém tra so_b6 (Visual Inspection) . Kiém tra do ludng (Metering checks) . Chife ning khodng céch F21 ( Distance Protection) . Chife ning qua dang pha (Phase Overcurrent Protection) . Chife ning qué dong cham dat (Earth Fault Overcurrent Protection) . Chite ning bao vé dign 4p (voltage check mode): Kiém tra bo ghi sy kign (Fault recorders, Event) . Kiém tra déng b6 thoi gian (time synchronising check): . Kiém tra mang tai (On - Load test): KET LUAN (Conclusion): Céc hang myc da thi nghiém dat yéu cau iF ‘thuat. (All testes have been performed completely according to test standard and pass) O}g/8/g/g/a\g/a\a 22 ]2) 2 F121) Nguoi thi nghigm DOi pho (Testers) di thi nghigm (Deputy head of department) 1) Dang Cong Tang. Hp 2) Doan Thanh Hai Dinh Xuan Dong Nguyén Héng Son Page 1 of 4 NPTS/BM.40 Sé bién ban: —476/NPTS2/RL_ KET QUA THi NGHIEM (TESTING RESULTS) 1, Kiém tra so b§ (Visual Inspection): 1. Kiém tra bén ngoai (Serial number on case, module and cover c sched) 2. Kiém tra mach dong, mach Ap (Current & Voltage Circuits checked) 3. Kiém tra so dé nguyén ly (External wiring checked - if available) 4, Kiém tra tiép dia an ton (Earth connection to case checked) gg 88) 98 5. Kiém tra cach dign (Insulation checked) iém tra nguon nudi (Auxiliary power checked) a 2. Kiém tra do wong (Metering checks): Dat (Pass) @ Khong datgail) 0 Giétrjduavao | Sid ies ea Gid trj tai trong role Anjected values) | Cateutted values (Measured values in Relay) I Pha | uw) | A | eas Eo evan | uv) | 1) | Peww) sar a ) A 63.5 1 0 76 0 63.46 | 1199.042 | 76.097 0.12 B 63.5 1 {| -120 76 0 64.49 | 1200.391 | 76.128 0.14 Cc 63.5 1 120 76 0 61.47 | 1199.431 | 74.159 1.920 3P. i / i 228 oO f f 226.367 1.648 Usynch 63.5 63.456 3. Bao vé khoaing cach (Distance Protection): Kiém tra bao vé F21 bi khéa khi mat Ap Dat (Pass) J Khong dateail) 0 (M6 phéng tai dinh mite, mdt dp 1 pha, hai pha va 3 pha) Bao vé khoaing céich pha-pha (Phase- Phase Distance) Dat (Pass) J Khong dat(ail) 0 5 Gid tri dat Gia trj tac dong Vang (Setting Values) (Tripping Values) en) | x@ | R® ts) | X@) RQ) | tims) i 1.59 12.5 1000 15 12 1003 2 OFF OFF / / i 304 3 1.59 30 1000 1.5 29 1002 | Bio vé khodng cach pha-dat (Phase- Earth Distance) Dat (Pass) Khong dat(fail) 0 5 Gid tr dat Gid ti tac dong Ving (Setting Values) (Tripping Values) vr) | x@ | R@ | ts | x@ | R@ | tm) L 1.59 12.5 1000 15 12 1003 2 OFF OFF / / t 304 3 1,59 30 1000 13 29 1002 4. Bio vé qua dong pha (Phase OC Protection): Page 2 of 4 Dat (Pass) J Khong dat(ail) O NPTS/BM.40 Sébién bin: — 476/ NPTS2/RL 4.1 Bio vg qué dong pha cit nhanh (Instantaneous Phase Overcurrent) : Gi tr dat Gia tr tae dong Cip tac dong (Setting Values) (Tripping Values) Stas é (See) st 1(A) | T(mS) 1(A) T (mS) AN 121 3301 BN 121 3301 CN 121 3301 cip 1 AB 12 3300 121 3301 B-C 1.21 3301 AC 121 3301 ‘ABC 121 3301 5. Bao vé qué dong cham dat (Earth fault OC Protection): 5.1 Bao vé qua dong cham dt khong huéng (Earth fault OC Protection) Dat (Pass) J Khong dat(fail) 0 Gia trj dat Gid tr] tac dng Cap tae dong (Setting Values) (Tripping Values) (Stage) Syed | IE TE : TE (mS) (Fault) | (A) (ms) Be) AN 021 3302 Cap 1 B-N 0.2 3300 0.21 3302 CN 021 3302 6. Chite ning bio vé dign Ap (Voltage protection) Dat Pass) J Khong dat(ail) O 6.1 Qua Ap thir ty nghjeh (Wegative sequence overvoltage elements) Chip the Gi tri dat Gia trj tac dong dong (Setting Values) (Tripping Values) (tage) U2>(V) T(S) U2>(V) T(S) 1 35 120 35 120 6.2. Qua ap thir ty khOng (Zero sequence overvoltage elements) Cép tae Gia tri dat Gia tr) tac dng dong (Setting Values) (Tripping Values) (Stage) 3U0>(V) TS) 3U0>(V) TS) 1 55 120 5.5 12 2 65 90 65 90 7. Kidm tra b6 ghi sy 6, su kign (Fault recorders, Event): Dat (Pass) @ Khéng datgail) C aie a Dénh gid Ghi cha umber o reomtiers (Estimate) (Remark) Ban ghi su c6 (Fault recorder) 20 Dat Ban ghi sy kign (Event recorder) 255 Dat 8. Kiém tra déng bg thai gian (time synchronising check): Page 3 of 4 Dat (Pass) Khong dat fail) 0 NPTS/BM.40 $6 bién ban: — 476/NPTS2/RL_ 9. Kiém tra dw6i tai (On - Load test): Dat (Pass) Khong datgail) 0 Gia tr tai trong role Cong suat thire Pha (Measured values in Relay) té EV) | Usynenckvy | 1(a) | Panwy | Qauvan} — “eadsow) A 1 7 7 7 B 7 / 7 7 7 I 6 7 7 7 7 Ghi cha: Ngdn 112 chia ding dién Page 4 of 4

You might also like