▶▶ Sizes 10 to 100
▶▶ Nominal pressure 3600 psi (250 bar)
▶▶ Maximum pressure 4550 psi (315 bar)
▶▶ Open circuit
A10VO 63DRS/53...
Features Inhalt
▶▶ Variable pump with axial piston rotary group in swash- Ordering code series 52/53 2
plate design for hydrostatic drives in open circuit. Hydraulic fluids 7
▶▶ The flow is proportional to the drive speed and the Operating pressure range 9
displacement. Technical data 10
▶▶ The flow can be infinitely varied by adjusting the swash- DR – Pressure control 14
plate angle. DRG – Pressure control, remotely operated 15
▶▶ Stable bearing for long service life DRF (DFR) / DRS (DFR1) / DRSC– Pressure and flow
▶▶ High permissible drive speed control 16
▶▶ Favorable power-to-weight ratio – compact dimensions LA... – Pressure, flow and power controller 18
▶▶ Low noise LA... – Variations 19
▶▶ Excellent suction characteristics ED – Electro-hydraulic pressure control 20
▶▶ Electro-hydraulic pressure control ER – Electro-hydraulic pressure control 21
▶▶ Power control EP – Electro-proportional control 22
▶▶ Electro-proportional swivel angle control EK – Electro-proportional control with controller cut-off 23
▶▶ Short response times EP(K).DF / EP(K).DS / EP(K) – with pressure and flow
control 24
EP.ED / EK.ED – with electro-hydraulic pressure control 25
Dimensions size 10 to 100 26
Dimensions through drive 61
Overview of attachment options 65
Combination pumps A10VO + A10VO 66
Connector for solenoids 67
Installation instructions 68
Project planning notes 72
01 02 03 04 05 06 07 08 09 10 11 12
A10V(S) O / 52 – V
Operation mode
02 Pump, open circuit O
Size (NG)
03 Geometric displacement, see table of values on page 10 10 28 45 60 85
Control devices
04 Pressure control hydraulic ● ● ● ● ● DR
with flow controller hydraulic X-T open ● ● ● ● ● DFR
X-T plugged with flushing function ● ● ● ● ● DFR1
without flushing function – ● ● ● ● DRSC
with pressure cut-off hydraulic remotely operated ● ● ● ● ● DRG
electric negative control U = 12 V – ● ● ● ● ED71
U = 24 V – ● ● ● ● ED72
electric positive control U = 12 V – ● ● ● ● ER71
U = 24 V – ● ● ● ● ER72
Differential pressure control electric control (negative control) – ○ ○ ○ ● EF..1)
Series
05 Series 5, Index 2 52
Direction of rotation
06 View on drive shaft clockwise R
counter-clockwise L
Sealing material
07 FKM (fluor-caoutchouc) V
Drive shaft
08 splined shaft standard shaft ● ● ● ● ● S
ANSI B92.1a similar to shaft "S" however for higher input torque – ● ● ● ● R
reduced diameter, limited suitability for through drive ● ● ● ● ● U
similar to shaft "U", however for higher torque – ● ● ● ● W
Parallel keyed shaft ISO 3019-1 limited suitability for through drive ● ● ● ● ● K
Tapered with Woodruff key – ● ● ● ● C
Mounting flange
09 ISO 3019-1 (SAE) 2-hole ● ● ● ● ● C
4-hole – – – ● – D
Note
▶▶ Observe the engineering notes regarding each
control device
01 02 03 04 05 06 07 08 09 10 11 12
A10V(S) O / 52 – V
Working port 10 28 45 60 85
10 SAE flange port rear not for through drive – ● ● ● ● 61
UNC fastening thread
at side, opposite for through drive – ● ● ● ● 62
Note
▶▶ Note the project planning notes on page 68.
▶▶ In addition to the ordering code, please specify the
relevant technical data when placing your order.
01 02 03 04 05 06 07 08 09 10 11 12
A10V(S) O / 53 – V
Operation mode
02 Pump, open circuit O
Size (NG)
03 Geometric displacement, see table of values on page 10 18 28 45 63 72 85 100
Control devices
04 Pressure control hydraulic ● ● ● ● ● ● ● DR
X-T open ● – – ● ● ● ● DRF
X-T plugged with flushing function ● – – ● ● ● ● DRS
without flushing function ● ● ● ● ● ● ● DRSC
with pressure cut-off hydraulic remotely operated ● ● ● ● ● ● ● DRG
electric negative control U = 12 V ● ● ● ● ● ● ● ED71
U = 24 V ● ● ● ● ● ● ● ED72
electric positive control U = 12 V ● ● ● ● ● ● ● ER71
U = 24 V ● ● ● ● ● ● ● ER72
Differential pressure control electric control (negative control) ○ ○ ○ ○ ○ ● ● EF.1)
Power control with pres- hydraulic start of control from 145 to 510 psi
● ● ● ● ● ● ● LA5D
sure cut-off (10 to 35 bar)
520 to 1015
● ● ● ● ● ● ● LA6D
(36 to 70 bar)
1030 to 1520 psi
● ● ● ● ● ● ● LA7D
(71 to 105 bar)
1535 to 2030 psi
● ● ● ● ● ● ● LA8D
(106 to 140 bar)
2045 to 3335 psi
● ● ● ● ● ● ● LA9D
(141 to 230 bar)
remotely operated hydraulic start of control see LA.D ● ● ● ● ● ● ● LA.DG
flow control, X-T hydraulic start of control see LA.D ● ● ● ● ● ● ● LA.DS
plugged electrically start of control see LA.D
overridable
● ● ● ● ● ● ● LA.S
(negative
control)
Note
▶▶ Observe the engineering notes regarding each
control device
01 02 03 04 05 06 07 08 09 10 11 12
A10V(S) O / 53 – V
18 28 45 63 72 85 100
04 Electro-proportional control positive control
with pressure control U = 12 V ● ● ● ● ● ● ● EP1D
U = 24 V ● ● ● ● ● ● ● EP2D
with pressure and flow control X-T open U = 12 V ● ● ● ● ● ● ● EP1DF
(load sensing) U = 24 V ● ● ● ● ● ● ● EP2DF
with pressure and flow control X-T plugged U = 12 V ● ● ● ● ● ● ● EP1DS
(load sensing) U = 24 V ● ● ● ● ● ● ● EP2DS
with electro-hydraulic pressure U = 12 V ● ● ● ● ● ● ● EP1ED
control U = 24 V ● ● ● ● ● ● ● EP2ED
Electro-proportional control positive control
with pressure control U = 12 V ● ● ● ● ● ● ● EK1D
U = 24 V ● ● ● ● ● ● ● EK2D
Pressure and flow control with controller cut- X-T open U = 12 V ● ● ● ● ● ● ● EK1DF
off (load sensing) U = 24 V ● ● ● ● ● ● ● EK2DF
Pressure and flow control with controller cut- X-T plugged U = 12 V ● ● ● ● ● ● ● EK1DS
off (load sensing) U = 24 V ● ● ● ● ● ● ● EK2DS
Electro-hydraulic pressure control with U = 12 V ● ● ● ● ● ● ● EK1ED
controller cut-off U = 24 V ● ● ● ● ● ● ● EK2ED
Series
05 Series 5, index 3 53
Direction of rotation
06 View on drive shaft clockwise R
counter clockwise L
Sealing material
07 FKM (fluor-caoutchouc) V
Drive shaft
08 Splined shaft standard shaft ● ● ● ● ● ● ● S
ANSI B92.1a similar to shaft “S” however for higher input torque ● ● ● ● ● ● – R
reduced diameter, limited suitability for through drive ● ● ● ● ● ● ● U
similar to shaft “U”, however for higher torque – ● ● ● ● ● ● W
Parallel keyed shaft ISO 3019-1 limited suitability for through drive ● ● ● ● ● ● ● K
Mounting flange
09 ISO 3019-1 (SAE) 2-hole ● ● ● ● ● ● ● C
4-hole – – – ● ● ● ● D
Note
▶▶ Note the project planning notes on page 68.
▶▶ In addition to the ordering code, please specify the
relevant technical data when placing your order.
01 02 03 04 05 06 07 08 09 10 11 12
A10V(S) O / 53 – V
Note
▶▶ Note the project planning notes on page 68.
▶▶ In addition to the ordering code, please specify the
relevant technical data when placing your order.
Hydraulic fluids
The A10VO variable pump is designed for operation with Notes on selection of hydraulic fluid
HLP mineral oil according to DIN 51524. The hydraulic fluid should be selected such that the operat-
Application instructions and requirements for hydraulic ing viscosity in the operating temperature range is within
fluids should be taken from the following data sheets the optimum range (νopt see selection diagram).
before the start of project planning:
▶▶ 90220: Hydraulic fluids based on mineral oils and Note
related hydrocarbons At no point of the component may the temperature be
▶▶ 90221: Environmentally acceptable hydraulic fluids higher than 239 °F (115 °C). The temperature difference
specified in the table is to be taken into account when
determining the viscosity in the bearing.
If the above conditions cannot be maintained due to
extreme operating parameters, please contact the respon-
sible member of staff at Bosch Rexroth.
▼▼ Selection diagram
Warm-up phase
Maximum permissible viscosity for cold start [mm /s] [SUS]
2
1600 1600
1000 4600
600 3000
400 2000
200 1000
VG 68
VG 46
VG
VG 32
VG 2
10
2
Viscosity ν [mm2/s]
Continuous operation
100 500
60 300
40 200
36 170
10 60
Minimum permissible viscosity for short-term operation
7 20
-40 -13 -14 32 50 86 122 158 194 239 [°F]
-40 -25 -10 0 10 30 50 70 90 115 [°C]
Minimum permissible temperature for cold start Temperature θ [°C]
pnom t2
Single operating period t1 tn
∆t
Maximum pressure pmax
Nominal pressure pnom
Pressure p
Pressure p
∆p
1.2 Note
24 (1.6) Operating pressure range valid when using hydraulic
Inlet pressure pabs psi (bar)
17 (1.2)
1.0 15 (1.0)
13 (0.9)
0.9 12 (0.8)
0.7 0.8 0.9 1.0
Displacement Vg/Vgmax
Technical data
1) Only series 52 5) The scope of application lies between the minimum necessary and
2) Only series 53 the maximum permissible drive speeds. It applies for external stim-
3) The values are applicable: uli (e. g. engine 2 to 8 times rotary frequency, cardan shaft twice
‒ At absolute pressure pabs = 15 psi (1 bar) at suction port S the rotary frequency). The limiting value is only valid for a single
‒ For the optimal viscosity range of pump. The loading capacity of the connecting parts must be taken
νopt = 170 to 80 SUS (36 to 16 mm2/s) into account.
‒ For hydraulic fluid based on mineral oils 6) On request
4) Please contact us regarding higher speeds
Note
▶▶ Theoretical values, without efficiency and tolerances;
values rounded.
▶▶ Operation above the maximum values or below the
minimum values may result in a loss of function, a
reduced service life or in the destruction of the axial
piston unit. Bosch Rexroth recommend testing the
loads by means of experiment or calculation / simula-
tion and comparison with the permissible values.
Axial force maximum + Fax max lbf 90 157 225 337 450 337 675 675
± Fax
(N) (400) (700) (1000) (1500) (2000) (1500) (3000) (3000)
Note
▶▶ The values given are maximum values and do not apply
to continuous operation. For drives with radial loading
(pinion, V-belt drives), please contact us!
▼▼ Distribution of torques
T1 T2
TE
TD
DR – Pressure control
The pressure control limits the maximum pressure at the ▼▼ Circuit diagram DR
▼▼ Characteristic curve DR
[bar] [psi]
max
250 3600
Hysteresis/pressure rise Δp
Operating pressure pB
L2 S
Controller data
NG 10 18 28 45 60 72 85 100
63
Pressure Δp [psi] 87 87 87 87 115 115 175 200
increase [bar] (6) (6) (6) (6) (8) (8) (12) (14)
Hysteresis Δp [psi maximum 45 (3)
and re- (bar)]
Standby 2)
peatability
Control gpm maximum approx. 0.8 (3)
fluid con- (l/min)
qv min Flow qV qv max
sumption
Characteristic curve valid for n1 = 1500 rpm and tfluid = 120 °F
(50 °C).
1) In order to prevent damage to the pump and the system, the per-
missible setting range must not be exceeded. The range of possi-
ble settings at the valve is higher.
For the remote-controlled pressure control, the LS pressure ▼▼ Circuit diagram DRG
increase [bar] (6) (6) (6) (6) (8) (8) (12) (14)
250 3600
Hysteresis/pressure rise Δp
Standby 2)
1) In order to prevent damage to the pump and the system, the per-
missible setting range must not be exceeded. The range of possi-
qv min Flow qV qv max ble settings at the valve is higher.
2) Zero stroke from pressure setting Δ p on controller (2)
Characteristic curve valid for n1 = 1500 rpm and tfluid = 120 °F
(50 °C). RE-A 92703/12.2016, Bosch Rexroth AG
16 A10VO series 52 and 53 | Axial piston variable pump
DRF (DFR) / DRS (DFR1) / DRSC– Pressure and flow control
▼▼ Characteristic curve DRF (DFR) / DRS (DFR1) / DRSC Plugged at DRS (DFR1) / DRSC valve
max X
[bar] [psi]
2
250 3600 1
Hysteresis/pressure rise Δp
3
Operating pressure pB
L L1 B
Standby2)
L2 S
Hysteresis/Pressure increase ΔqV
qV max
1 The metering orifice (control block) and the line is not
included in the delivery contents.
2 Pressure and flow controller (FR).
Flow qV
Controller data
▶▶ DR pressure controller data see page 14.
▶▶ Maximum flow deviation measured at drive speed
n = 1500 rpm.
NG 10 18 28 45 60 72 85 100
63
Flow deviation Δq vmax [gpm (l/min)] 0.13 (0.5) 0.24 (0.9) 0.26 (1.0) 0.48 (1.8) 0.66 (2.5) 0.66 (2.5) 0.83 (3.1) 0.83 (3.1)
Hysteresis and Δp [psi (bar)] maximum 45 (3)
repeatability
Control fluid gpm (gpm (l/min)) maximum approx. 0.8 to 1.2 (3 to 4.5) (DRF (DFR))
consumption maximum approx. 0.8 (3) (DRS (DFR1) / DRSC)
Pressure control equipped as DR(G), see page 14 (15). ordering please state the power characteristics to be set ex
Equipment of the flow control like DRS (DFR1), see works in clear text, e.g. 27 HP (20 kW) at 1500 rpm.
page 16. Controller data
In order to achieve a constant drive torque with varying ▶▶ Pressure controller DR see page 14.
operating pressures, the swivel angle and with it the vol- ▶▶ Pressure and flow controller DR see page 16.
ume flow from the axial piston pump is varied so that the ▶▶ See data sheet 92709 for electric override LA.S
product of flow and pressure remains constant. Flow con- ▶▶ Control fluid consumption max. approx. 1.45 gpm (5.5 l/
troller is possible below the power control curve. When min)
Start of control Torque T [lb-ft (Nm)] for nominal size Order
psi (bar) 18 28 45 63 72 85 100 code
145 to 510 2.80 – 8.92 4.4 – 14 7.4 – 22.1 11 – 32 12.5 – 36.3 15 – 42 18 – 49.5 LA5
(10 to 35) (3.8 – 12.1) (6 – 19) (10 – 30) (15 – 43) (17 – 49.2) (20 – 57) (24 – 68)
520 to 1015 8.92 – 17.2 14 – 26.5 22.2 – 43.5 32 – 61 36.4 – 69.9 42 – 83 49.5 – 97.1 LA6
(36 to 70) (12.2 – 23.3) (19.1 – 36) (30.1 – 59) (43.1 – 83) (49.3 – 94.9) (57.1 – 112) (68.1 – 132)
1030 to 1520 17.2 –24.9 26.6 – 38.4 43.6 – 62 61 – 88 70 – 100.3 83 – 118 97.1 – 139.4 LA7
(71 to 105) (23.4 – 33.7) (36.1 – 52) (59.1 – 84) (83.1 – 119) (95.0 – 136.0) (112.1 – 160) (132.1 – 189)
1535 to 2030 24.9 –33.2 38.4 – 51.6 62 – 83 88 – 116 100.4 – 132.3 118 – 156 139.4 – 183.6 LA8
(106 to 140) (33.8 – 45) (52.1 – 70) (84.1 – 112) (119.1 – 157) (136.1 – 179.4) (160.1 – 212) (189.1 – 249)
2045 to 3335 33.2 – 55.2 51.7 – 86.3 83 – 139 116 – 195 132.4 – 222.5 156 – 263 183.3 – 309 LA9
(141 – 230) (45.1 – 74.8) (70.1 – 117) (112.1 – 189) (157.1 – 264) (179.5 – 301.7) (212.1 – 357) (249.1 – 419)
250 3600
LA9
200 2900 LA8 1
150 2200
LA7
100 1450
LA6
50 725
LA5
0 0
0 Volume flow qV [%] 100
L L1 B
∆qV
LA9
Torque T [lb-ft (Nm)]
LA8
LA7
LA6
LA5
0 100
Volume flow qV [%] L2 S
LA... – Variations
▼▼ Circuit diagram LA.D with pressure cut-off ▼▼ Circuit diagram LA.S with separate flow control
1
L L1 B
L L1 B
L2 S
L2 S
▼▼ Circuit diagram LA.DG with pressure cut-off, remotely operated
Controller data
▶▶ See data sheet 92709 for electric override LA.S
L L1 B
L2 S
1 The pressure relief valve and the line are not included in
the scope of delivery.
The ED valve is set to a certain pressure by a specified ▼▼ Influence of the pressure setting on standby
(maximally energized)
variable solenoid current.
Changing the consumer (load pressure) causes an increase [bar] [psi]
or decrease in the pump swivel angle (flow) in order to 34 500
Thus the pump only delivers as much hydraulic fluid as the 30 435
consumers can take. The desired pressure level can be set 28 405
Standby
steplessly by varying the solenoid current. 26 375
of control
Max. adjustable
control pressure
140 2000
250 3600
Δp max < 60 psi (4 bar)
pressure pB (de-energized)
Maximum operating
Setting range
L2 S
[bar] [psi]
350 5100
250 3600
Operating pressure pB
Maximum adjustable
control pressure
150 2200
Minimum ad-
50 725 justable control L2 S
14 200 pressure
0 0
0 Current I/Imax 1 Technical data, solenoid ER71 ER72
Voltage 12 V (±20%) 24 V (±20%)
▶▶ Hysteresis static current-pressure characteristic Control current
curve < 3 bar. Start of control at p min 100 mA 50 mA
End of control at p max 1200 mA 600 mA
▼▼ Flow-pressure characteristic curve Limiting current 1.54 A 0.77 A
200 Hz 200 Hz
max
Setting range
EP – Electro-proportional control
stroke of dither
1000 Limiting current 1.54 A 0.77 A
ΔI, independent of
EP1
the mean value Nominal resistance (at 68 °F (20 °C)) 5.5 Ω 22.7 Ω
800
Duty cycle 100% 100%
Type of protection: see connector version page 67
600
Operating temperature range at valve -4 °F to 239 °F (-20 °C to
EP2
+115 °C)
400
200 Note
We recommend the valve with flushing function for the
EP.D control variant. Please contact us.
0 0.5 1.0
Displacement [%]
Vg min Vg max
Variant EK... is based completely on the variant EP... (see ▼▼ Circuit diagram EK.D
page 22).
In addition to the electro-proportional control function, a
controller cut-off is integrated in the electric characteristic
curve. The pump then swivels to Vg max if the pilot signal is
lost (e.g., cable break) and then works with the DRF set- L L1 B
In the Vg max the spring force of the return spring is maxi- Voltage 12 V (±20%) 24 V (±20%)
mum. To overcome the force of this spring, the solenoid Control current
must be subjected to excessive current (Ires). Start of control at Vg min 400 mA 200 mA
End of control at Vg max 1200 mA 600 mA
▼▼ Characteristic EK1/2 Minimum working stroke of the 352 mA 176 mA
dither within the control range1)
electro-proportional control.
The pressure control regulates the pump displacement
X
infinitely varied back to Vg min after the set target pressure
has been reached. 1
This function is super-imposed on the EP or EK control, i.e.
the control-current dependent EP or EK function is exe-
cuted below the target pressure.
For the adjustment range of the pressure flow control, see
page 14 to 16.
With all controller combinations, the Vg reduction has priority.
With flow control, the pump flow can be influenced in L L1 B
L2 S
L L1 B
L2 S
L2 S
L L1 B
L2 S
Dimensions size 10
6)
(5
0.25 (6.4)
L
20
2.
Flange
45°
ISO 3019-1
0. )
0.43
35
(11)
(9
(ø 82.55 -0.054)
DIA 3.250
3.248
45°
0
2.11 (53.5)
2.20 (56)
L1
View Y View Y
Valve mounting for Valve mounting for
clockwise rotation counter-clockwise rotation
S B
B S
1.13 1.13 1.13 1.13
(28.6) (28.6) (28.6) (28.6)
2.00 (51) 2.00 (51) 2.00 (51) 2.00 (51)
▼▼ Splined shaft 3/4 in (SAE J744) ▼▼ Splined shaft 5/8 in (SAE J744)
S ‒ 11T 16/32DP 1)
U ‒ 9T 16/32DP1)
1.18 (30)
0.94 (23.8)
1/4-20UNC-2B2) 4)
0.55 (14)
0.20 (5)
0.87 (ø22)
0.87 (ø22)
Centering 3)
R3 0.59 × 0.26
DIN 332 0.62
0.83 (21)
(15.8)
1.50 (38)
1.25 (31.8)
1.30 (33)
-0.004 )
Key width
+0.009
0.01
(2.5)
-0.1 )
0.87 (Ø22)
DIA 0.750
(21.1+0.05
0.833
0.827
Centering 3)
R3 0.59 × 0.26
DIN 332 1.61 (41)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat 5) Momentary pressure spikes may occur depending on the application.
root, side fit, tolerance class 5 Keep this in mind when selecting measuring devices and fittings.
2) Thread according to ASME B1.1 6) The spot face can be deeper than as specified in the standard.
3) Coupling axially secured, e.g. with a clamp coupling or radially 7) Depending on the installation position, L or L1 must be connected
mounted clamping screw (also see installation instructions starting on page 68).
4) Observe the instructions in the operating instructions concerning 8) O = Must be connected (plugged when delivered)
the maximum tightening torques. X = Plugged (in normal operation)
▼▼ DRG – Pressure control, remotely operated (SAE)1) ▼▼ DFR/DFR1 – Pressure, flow control (SAE)1)
4.02 (102)
4.02 (102)
3.74 (95)
3.74 (95)
L1 L1
7.05 (179) 7.05 (179)
Dimensions size 18
▼▼ Port plate 61
3.27 (83)
0.31 (7.8) 0.39 (10)
0.96
(24.5) L1
L1
4.80 (122)
Flange
ISO 3019-1 L
2.83 (72)
0.
09
L 45°
(2
)
.5
(Ø82.55- 0.054
)
3.250
DIA 3.248
5)
5)
0
1.
1.
X
(6
(6
42
42
2.
2.48 (63)
0.43 (11)
2.
45°
L2
(47.6)
(Ø32)
1.87
S B
1.19
(30.2) 0.87 (22.2)
▼▼ Port plate 62 Detail Z 1.26 1.30
(32) (33)
DIA 0.79 (Ø20)
3.27 (83)
1.87 (47.6)
L1
Flange B 0.87
ISO 3019-1 (22.2)
L
(Ø82.55 - 00.054 )
2.31 (58.7)
DIA 3.250
3.248
DIA 1.26
(Ø32)
Y Z
S
1.19 (30.2)
5.63 (143) 2.22 (56.5) 2.22 (56.5)
6.70 (170)
▼▼ Splined shaft 3/4 in (SAE J744) ▼▼ Splined shaft 3/4 in (SAE J744)
S ‒ 11T 16/32DP 1)
R ‒ 11T 16/32DP1)2)
1.18 (30)
0.55 (14)
0.55 (14)
1/4-20UNC-2B4) 5)
1/4-20UNC-2B4)5)
0.20 (5)
0.20 (5)
0.87 (Ø22)
(Ø22)
0.87
Usable shaft 0.83 (21)
0.83 (21) length
1.50 (38)
1.50 (38)
▼▼ Splined shaft 5/8 in (SAE J744) ▼▼ Parallel keyed shaft DIN 6885
U ‒ 9T 16/32DP 1)
K ‒ 19-1
0.94
1.30 (33)
-0.004 )
+0.009
(23.8) Key width
1.13 (28.6) 0.188 (4.76+0.025)
0.187
0.749 (ø19.05
0.01
0.87 (ø22)
(2.5)
-0.1 )
0.87 (Ø22)
DIA 0.750
(21.1+0.05
0.833
0.827
Centering 3)
R3 0.59 × 0.26
DIN 332
0.62
(15.8)
1.61 (41)
1.25 (31.8)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat 6) Momentary pressure spikes may occur depending on the application.
root, side fit, tolerance class 5 Keep this in mind when selecting measuring devices and fittings.
2) Splines according to ANSI B92.1a, run out of spline is a deviation 7) The spot face can be deeper than as specified in the standard.
3) Center bore according to DIN 332 nected (also see installation instructions starting on page 68).
4) Thread according to ASME B1.1 9) Only series 53
5) Observe the instructions in the operating instructions concerning 10) O = Must be connected (plugged when delivered)
▼▼ DRG – Pressure controller, remote controlled, series 53 ▼▼ EP.D. / EK.D. – Electro-proportional control, series 53
4.80 (122)
4.17 (106)
4.17 (106)
L
4.80 (122)
L
S
S L2 L2
▼▼ DRF/DRS/DRSC – Pressure and flow control, series 53 ▼▼ EP.ED. / EK.ED. – Electro-proportional control, series 53
4.33 (110)
L L
4.80 (122)
L2
S L2
▼▼ LA.D. – Pressure, flow and power control, series 53 ▼▼ ED7. / ER7. – Electro-proportional Pressure control, series 53
8.86 (225)
8.42 (214)
4.45 (113) 2.44 (62)
X
L1
L1
4.80 (122)1)
4.80 (122)
4.45 (113)
4.17 (106)
L
L
L2 S L2
S
Dimensions size 28
▼▼ Port plate 61
3.54 (90)
0.37 (9.5) 0.47 (12)
0.25 (6.3) 45°
4.86 (123.5)
Flange
ISO 3019-1
L
0.56 (14.3)
L
)
4.000
DIA 3.998
(ø101.6 -0.054
69
X
0
2.60 (66)
2.87 (73)
1.06 (27) L1 5.75 (146)
0.31 (7.9) 6.69 (170) 6.77 (172)
0.79 (ø20)
2.31 (58.7)
1.26 (ø32)
(47.6)
1.87
S B
0.47 (12)
View Y1)
0.37 (9.5)
0.25 (6.3)
Flange B
ISO 3019-1 0.87 (22.2)
L
)
2.31 (58.7)
4.000
DIA 3.998
(ø101.6 -0.054
Y Z
0
(ø32)
B
1.26
▼▼ Splined shaft 7/8 in (SAE J744) ▼▼ Splined shaft 7/8 in (SAE J744)
S ‒ 13T 16/32DP 1)
R ‒ 13T 16/32DP1)2)
1.30 (33.1)
0.63
(16) 0.63 (16)
1/4-20UNC-2B3)4)
1/4-20UNC-2B3) 4)
▼▼ Splined shaft 3/4 in (SAE J744) ▼▼ Splined shaft 3/4 in (SAE J744)
U ‒ 11T 16/32DP 1)
W ‒ 11T 16/32DP1)2)
1.18 (30)
0.55
1/4-20UNC-2B3) 4)
1/4-20UNC-2B3) 4)
0.20
0.20
(5)
(5)
0.87
(22)
Usable shaft length 0.83 (21)
1.50 (38)
1.50 (38)
▼▼ Parallel keyed shaft (ISO 3019-1) ▼▼ Tapered with woodruff key (ISO 3019-1)
K ‒ 22-1 C
1.31 (33.3)
1/4-20UNC-2B 3) 4)
0.8742 (ø22.225 -0.02)
)
(Ø21.774 +0.006
+0.025
0.8575
DIA 0.8570
0.98 (Ø25)
DIA 0.8750
(25 -0.2 )
0.9843
0.9764
0.130
0.16 (Ø4) B
0.118 1.10
0.110 (3 -0.2) (28)
2.19 (55.6)
1.63 (41.3)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat 3) Thread according to ASME B1.1
root, side fit, tolerance class 5 4) Observe the instructions in the operating instructions concerning
2) Splines according to ANSI B92.1a, run out of spline is a deviation the maximum tightening torques.
from standard.
1) Observe the instructions in the operating instructions concerning 4) Depending on the installation position, L, L1 or L2 must be con-
the maximum tightening torques. nected (also see installation instructions starting on page 68).
2) Momentary pressure spikes may occur depending on the application. 5) Only for series 53
Keep this in mind when selecting measuring devices and fittings. 6) O = Must be connected (plugged when delivered)
3) The spot face can be deeper than as specified in the standard. X = Plugged (in normal operation)
▼▼ DRG – Pressure controller, remote controlled, series 52 (53) ▼▼ EP.D. / EK.D. – Electro-proportional control, series 53
5.12 (130)
4.86 (123.5)
4.49 (114)
L
4.21 (107)
L
L
S
S L2
L1
▼▼ DFR/DFR1/DRSC – Pressure and flow control, series 52 (53) ▼▼ EP.ED. / EK.ED. – Electro-proportional control, series 53
5.12 (130)
4.61 (117)
4.21 (107)
L L
L
L2
S
L1
▼▼ LA.D. – Pressure, flow and power control, series 53 ▼▼ ED7. / ER7. – Electro-proportional Pressure control, series 52 (53)
9.09 (231)
5.51 (140) 2.48 (63)
9.45 (240)
L1
X
5.12 (130)1)
X
5.12 (130)
4.49 (114)
L L
S
S
L2
L1
Dimensions size 45
▼▼ Port plate 61
3.90 (99)
0.37 (9.5) 0.47 (12)
0.25 (6.3) 1.18 45°
(30)
L1
5.18 (131.5)
Flange
ISO 3019-1
0.56 (14.3)
L
3.03 (77)
(Ø101.6 -0.054 )
DIA 4.000
3.998
)
78
X
0
1(
3.
2.70 (68.5)
7.44 (189) 5.75 (146)
max. 8.68 (220.5) 6.77 (172)
▼▼ Port plate 62
max. 8.68 (220.5)
5.93 (150.5)
3.90 (99)
View X1)
0.37 (9.5) 0.47 (12)
0.25 (6.3) 1.18 (30)
L1
Flange
ISO 3019-1 S
)
L
.9
69
0.98 (ø25)
5(
(Ø101.6 -0.054 )
2.7
4.000
DIA 3.998
2.75 (69.9)
1.50 (ø38)
0
Y
(ø38)
1.50
(5 06
)
2.4
2.
S
1. B
1.41 1.
(3 41 (26 03 30°
(35.7) 5.7 .2)
) 30°
7.01 (178) 1.50 1.50
8.31 (211) Detail Z (38) (38)
B View Y1)
2.06 (52.4)
0.98 (Ø25)
1.03
(26.2)
Z
S B
1/4-20UNC-2B3) 4)
3) 4)
0.20 (5)
0.20(5)
1/4-20UNC-2B
▼▼ Splined shaft 7/8 in SAE J744 ▼▼ Splined shaft 7/8 in SAE J744
U ‒ 13T 16/32DP 1)
W ‒ 13T 16/32DP1)
1.30 (33.1)
0.63 (16)
1/4-20UNC-2B3) 4)
0.63 (16)
1/4-20UNC-2B3) 4)
0.20 (5)
0.20 (5)
▼▼ Parallel keyed shaft (ISO 3019-1) ▼▼ Tapered with woodruff key (ISO 3019-1)
K ‒ 25-1 C
1.50 (38.1)
1/4-20UNC-2B 3) 4)
0.63 (16)
0.260 (6.35+0.25) 0.75 (19) 0.251
0.20
5/8-18UNF-2A3) 4)
)
(Ø21.774 +0.006
+0.025
0.8575
DIA 0.8570
0.98 (Ø25)
DIA 1.000
0.998
(28.2 -0.2 )
0.250(6.35
0.251
0.130
B
0.16 (Ø4)
0.13 (3.2) 1.18
1.81 (46) (30)
2.43 (61.8)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat 6) The spot face can be deeper than as specified in the standard.
root, side fit, tolerance class 5 7) Depending on the installation position, L, L1 or L2 must be con-
2) Splines according to ANSI B92.1a, run out of spline is a deviation nected (also see installation instructions starting on page 68).
from standard. 8) Only series 53
3) Thread according to ASME B1.1 9) O = Must be connected (plugged when delivered)
4) Observe the instructions in the operating instructions concerning X = Plugged (in normal operation)
the maximum tightening torques.
5) Momentary pressure spikes may occur depending on the application.
Keep this in mind when selecting measuring devices and fittings.
▼▼ DRG – Pressure controller, remote controlled, series 52 (53) ▼▼ EP.D. / EK.D. – Electro-proportional control, series 53
5.18 (131.5)
L1 X
5.22 (132.5)
4.53 (115)
4.57 (116)
L
S
L
S
L2
▼▼ DFR/DFR1/DRSC – Pressure and flow control, series 52 (53) ▼▼ EP.ED. / EK.ED. – Electro-proportional control, series 53
L1
4.69 (119)
L
4.53 (115)
5.24 (133)
L S
S L2
▼▼ LA.D. – Pressure, flow and power control, series 53 ▼▼ ED7. / ER7. – Electro-proportional Pressure control, series 52 (53)
9.25 (235)
5.75 (146) 2.68 (68) 9.84 (250)
L1
X X L1
X
5.24 (133)
4.58 (116.4)
5.20 (132)1)
L L
S L
S
L2
Dimensions size 60
▼▼ Port plate 61
max. 8.68 (220.5)
4.61 (117)
0.37 1.57
(9.5) (40) L1
X
5.39 (137)
Flange
ISO 3019-1
0.56 (14.3)
3.43 (87)
L 45°
(Ø101.6 -0.054 )
DIN 4.000
3.998
5)
0
8.
X
(7
3.07 (78)
0.59 (15) 5.75 (146)
8.19 (208) 6.77 (172)
View X1)
0.98 (Ø25)
S B
3.06 (77.8)
1.97 (Ø50)
(52.4)
2.06
S B
4.61 (117)
0.98 (Ø25)
3.06 (77.8)
(Ø101.6 -0.054
DIN 4.000
3.998
0
(Ø50)
Y
1.97
Z
B
S
Dimensions size 60
▼▼ Port plate 61
max. 8.68 (220.5)
4.61 (117)
0.50 1.57 (40)
(12.7) L1
X
0.24 (6)
5.41 (137.4)
Flange
L
0. 4.
56 3)
(1
ISO 3019-1
L
3.43 (87)
45°
4.51 (114.5)
(Ø127 -0.063)
DIA 5.0000
4.9975
5.83 (148)
5)
8.
0
(7
X
09
3.
3.07 (78)
0.59 (15) 4.51 (114.5)
8.19 (208) 5.75 (146)
View X1)
0.98 (Ø25)
3.06 (77.8)
1.97 (Ø50)
(52.4)
2.06
B
1.67 (42.9) 1.03 (26.2)
▼▼ Port plate 62 1.30 1.81
Detail Z
max. 8.68 (220.5) (33) (46)
2.06 (52.4)
4.61 (117)
0.98 (Ø25)
Flange B
ISO 3019-1 1.03 (26.2)
L
3.06 (77.8)
(Ø127 -0.063)
DIA 5.0000
4.9975
(Ø50)
1.97
0
Y Z
B
S
Dimensions size 63
▼▼ Port plate 61
5.53 (140.4)
4.37 (111)
Flange
0.56 (14.3)
3.50 (89)
ISO 3019-1 43°
(Ø101.6-0.054)
)
DIA 4.000
3.998
9
(7
0
5)
X
11
7.
(7
3.
05
3.46 (88)
45°
3.
L2
View X1)
0.98 (Ø25)
S B
1.97 (Ø50)
3.06 (77.8)
(52.4)
2.06
S B
4.55 (115.5)
0.37 (9.5) 1.54 (39) View Y1)
0.25 (6.3)
B
1.03 (26.2)
Flange
ISO 3019-1
)
3.06 (77.8)
-0.054
DIA 4.000
3.998
(Ø50)
0
Y
1.97
Z
(Ø101.6
B
S
S
0.59 (15)
Dimensions size 63
▼▼ Port plate 61
max. 8.68 (220.5)
4.55 (115.5)
0.50 (12.7) 1.54
0.25 (6.3) (39)
L1 X L1
Flange L
4)
5.51 (140)
(1
ISO 3019-1
4.37 (111)
55
0.
43°
3.50 (89)
45°
45°
4.51 (114.5)
(Ø127 -0.063 )
)
5.75 (146)
9
DIA 5.0000
4.9975
(7
5)
X
11
0
7.
3.
(7
05
3.46 (88)
45°
3.
L2
0.59 (15)
4.51 (114.5)
8.19 (208)
5.75 (146)
5.91 (150)
View X1)
2.06 (52.4)
0.98 (Ø25)
1.97 (Ø50)
3.06 (77.8)
B
S
1.69
▼▼ Port plate 62
(42.9) 1.03 (26.2)
1.30 1.81
max. 8.68 (220.5) Detail Z (33) (46)
4.55 (115.5)
0.50 (12.7) 1.54 (39) View Y1)
2.06 (52.4)
0.98 (Ø25)
0.25 X
L1
(6.3)
Flange
ISO 3019-1
B 1.03
(26.2)
(Ø127 -0.063 )
3.06 (77.8)
DIA 5.0000
4.9975
(Ø50)
1.97
Y Z
0
B
S
0.59 (15)
4.55 (115.5) 1.69 2.83 (72) 2.83 (72)
7.93 (201.5) (42.9)
9.43 (239.5)
▼▼ Splined shaft 1 1/4 in SAE J744 ▼▼ Splined shaft 1 1/4 in SAE J744
S ‒ 14T 12/24DP 1)
R ‒ 14T 12/24DP1)2)
3) 4) 1.87 (47.5)
0.75 (19) 0.75 (19)
5/16-18UNC-2B3) 4)
5/16-18UNC-2B
1.56
Usable shaft length 1.50 (38)
(39.5)
2.18 2.18 (55.4)
(55.4)
1.50 (38)
0.63 (16) 0.63 (16)
1/4-20UNC-2B3) 4)
1/4-20UNC-2B3) 4)
0.20 (5) 0.20 (5)
1.81 (45.9)
▼▼ Parallel keyed shaft (ISO 3019-1) ▼▼ Tapered with woodruff key (ISO 3019-1)
K ‒ 32-1 C
1.87 (47.5)
1/4-20UNC-2B 3) 4)
(ø31.75 -0.03)
125:1000
Key width
0.75 (19)
0.3223 (7.94+0.25) 0.93 (23.6) 0.3136
0.20 0.3125 0.3126 (7.94 +0.025)
0.56 (14.1)
1-12UNF-2A3) 4)
(5) A
0.3126 (7.94 +0.025)
-0.006 )
1.2403
DIA 1.2399
(Ø31.51 +0.006
(35.3 -0.2 )
(Ø34.91)
1.3898
1.3819
DIA 1.250
1.249
0.3136
0.1394
B
0.16 (Ø4) 1.18
0.12 (3) (30)
2.18 (55.4) 2.61 (66.4)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat 6) The spot face can be deeper than as specified in the standard.
root, side fit, tolerance class 5 7) Depending on the installation position, L, L1 or L2 must be con-
2) Splines according to ANSI B92.1a, run out of spline is a deviation nected (also see installation instructions starting on page 68).
from standard. 8) Only series 53
3) Thread according to ASME B1.1 9) O = Must be connected (plugged when delivered)
4) Observe the instructions in the operating instructions concerning X = Plugged (in normal operation)
the maximum tightening torques.
5) Momentary pressure spikes may occur depending on the application.
Keep this in mind when selecting measuring devices and fittings..
▼▼ DRG – Pressure controller, remote controlled, series 53 (52) ▼▼ EP.D. / EK.D. – Electro-proportional control, series 53
9.49 (241)
max. 8.68 (220.5)
5.94 (151) 2.55 1.40
5.93 (150.5) X 2.56 (65) 4.55 (115.5) (64.8)(35.6)
X
L1 L1 L1
X
X
L
5.39 (137)
5.53 (140.4)
4.88 (123.9)
4.76 (121)
4.92 (125)
L
S S L2
▼▼ DFR/DFR1/DRSC – Pressure and flow control, series 53 (52) ▼▼ EP.ED. / EK.ED. – Electro-proportional control, series 53
L
5.39 (137)
5.53 (140.4)
4.76 (121)
4.92 (125)
L
S
S L2
▼▼ LA.D. – Pressure, flow and power control, series 53 ▼▼ ED7. / ER7. – Electro-proportional Pressure control, series 53 (52)
9.72 (247)
5.91 (150) 2.56 (65) 9.88 (251)
X
L1 L1
5.51 (140)
X
5.39 (137)1)
4.88 (124)
5.04 (128)
L
L1 L
L S
S L2
Dimensions size 72
▼▼ Port plate 61
max. 8.68 (220.5)
4.55 (115.5)
L1
L1
L
5.53 (140.4)
4.37 (111)
Flange
0.56 (14.3)
3.50 (89)
ISO 3019-1 43°
(Ø101.6-0.054)
)
DIA 4.000
3.998
9
(7
0
5)
X
11
7.
(7
3.
05
3.46 (88)
45°
3.
L2
View X1)
0.98 (Ø25)
S B
1.97 (Ø50)
3.06 (77.8)
(52.4)
2.06
S B
4.55 (115.5)
0.37 (9.5) 1.54 (39) View Y1)
0.25 (6.3)
B
1.03 (26.2)
Flange
ISO 3019-1
)
3.06 (77.8)
-0.054
DIA 4.000
3.998
(Ø50)
0
Y
1.97
Z
(Ø101.6
B
S
S
0.59 (15)
Dimensions size 72
▼▼ Port plate 61
4)
5.51 (140)
(1
ISO 3019-1
4.37 (111)
55
0.
43°
3.50 (89)
45°
45°
4.51 (114.5)
(Ø127 -0.063 )
)
5.75 (146)
9
DIA 5.0000
4.9975
(7
5)
X
11
0
7.
3.
(7
05
3.46 (88)
45°
3.
L2
0.59 (15)
4.51 (114.5)
8.19 (208)
5.75 (146)
5.91 (150)
View X1)
2.06 (52.4)
0.98 (Ø25)
1.97 (Ø50)
3.06 (77.8)
B
S
▼▼ Port plate 62 1.69
(42.9) 1.03 (26.2)
max. 8.68 (220.5) Detail Z 1.30 1.81
(33) (46)
4.55 (115.5)
0.50 (12.7) 1.54 (39)
2.06 (52.4)
0.98 (Ø25)
View Y1)
0.25 X
L1
(6.3)
Flange
ISO 3019-1 B 1.03
(26.2)
(Ø127 -0.063 )
3.06 (77.8)
DIA 5.0000
4.9975
(Ø50)
1.97
Y Z
0
B
S
0.59 (15)
4.55 (115.5) 1.69 2.83 (72) 2.83 (72)
7.93 (201.5) (42.9)
9.43 (239.5)
▼▼ Splined shaft 1 1/4 in SAE J744 ▼▼ Splined shaft 1 1/4 in SAE J744
S ‒ 14T 12/24DP 1)
R ‒ 14T 12/24DP1)2)
1.87 (47.5)
5/16-18UNC-2B3) 4)
0.75 (19)
3) 4)
0.75 (19)
5/16-18UNC-2B 0.20 (5) 0.20 (5)
1.50 (38)
0.63 (16)
1/4-20UNC-2B3) 4)
1/4-20UNC-2B3) 4)
0.63 (16)
0.20 (5)
0.20 (5)
1.87 (47.5)
1/4-20UNC-2B 3) 4)
(ø31.75 -0.03)
Key width
0.75 (19)
0.3223 (7.94+0.25)
0.20 0.3125
(5)
(35.3 -0.2 )
(Ø34.91)
1.3898
1.3819
DIA 1.250
1.249
1.37
2.18 (55.4)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat 3) Thread according to ASME B1.1
root, side fit, tolerance class 5 4) Observe the instructions in the operating instructions concerning
2) Splines according to ANSI B92.1a, run out of spline is a deviation the maximum tightening torques.
from standard.
1) Observe the instructions in the operating instructions concerning 4) Depending on the installation position, L, L1 or L2 must be con-
the maximum tightening torques. nected (also see installation instructions starting on page 68).
2) Momentary pressure spikes may occur depending on the application. 5) Only series 53
Keep this in mind when selecting measuring devices and fittings. 6) O = Must be connected (plugged when delivered)
3) The spot face can be deeper than as specified in the standard. X = Plugged (in normal operation)
▼▼ DRG – Pressure controller, remote controlled, series 53 ▼▼ EP.D. / EK.D. – Electro-proportional control, series 53
9.49 (241)
max. 8.68 (220.5)
5.94 (151) 2.55 1.40
5.93 (150.5) 2.56 (65) 4.55 (115.5) (64.8)(35.6)
X X
L1
X X
5.53 (140.5)
5.53 (140.4)
4.88 (123.9)
4.92 (125)
4.88 (124)
L L
S L2 S L2
▼▼ DRF/DRS/DRSC – Pressure and flow control, series 53 ▼▼ EP.ED. / EK.ED. – Electro-proportional control, series 53
5.53 (140.4)
4.88 (124)
4.92 (125)
L L
S
S L2 L2
▼▼ LA.D. – Pressure, flow and power control, series 53 ▼▼ ED7. / ER7. – Electro-proportional Pressure control, series 53
9.72 (247)
5.91 (150) 2.56 (65) 9.86 (250.5)
X
L1
5.53 (140.5)1)
X
5.51 (140)
X
4.88 (124)
5.04 (128)
L L
S L2
S L2
Dimensions size 85
▼▼ Port plate 61
max. 9.53 (242)
5.12 (130) L1
0.50 (12.7) 1.57 (40)
X L
Flange
6.14 (156)
ISO 3019-1
3.68 (93.5)
45°
)
5.0000
DIA 4.9975
(Ø127-0.063
5)
(9
0
74
3.
0.69 (17.5)
3.42 (87)
0.79 (20) 7.13 (181)
9.65 (245) 8.27 (210)
View X1)
1.26 (Ø32)
3.50 (88.9)
2.36 (Ø60)
(66.7)
2.63
B
2.00
(50.8) 1.25 (31.8)
▼▼ Port plate 62
Detail Z 1.97 1.77
(50) (45)
max. 9.51 (241.5)
2.63 (66.7)
1.26 (Ø32)
5.12 (130)
View Y1)
0.50 (12.7) 1.57 (40)
X
Flange
B
ISO 3019-1 1.25
(31.8)
L
)
5.0000
DIA 4.9975
3.50 (88.9)
(Ø127-0.063
(Ø63)
0
Y Z
2.48
B
S
Dimensions size 85
▼▼ Port plate 61
max. 9.90 (251.5)
5.63 (143)
L1
0.50 (12.7) 1.42 (36)
X
L
Flange
5.91 (150)
4.96 (126)
ISO 3019-1
0.
)
)
3) 4.51 (114.5)
5.0000
DIA 4.9975
(Ø127 -0.063
5)
5)
(9
0
(9
74
74
3.
3.
45°
0.
16
4. 6
(1 5
0.
(4
)
5.12 (130) L2
9.65 (245) 4.51 (114.5)
5.75 (146)
View X1)
1.26 (Ø32)
3.50 (88.9)
2.36 (Ø60)
(66.7)
2.63
S B
2.00
(50.8) 1.25 (31.8)
▼▼ Port plate 62 1.97 1.77
1.26 (Ø32)
(50) (45)
Detail Z
max. 9.90 (251.5)
5.63 (143)
2.63 (66.7)
View Y1)
0.50 (12.7) 1.42 (36)
X
Flange
ISO 3019-1
B
1.25
(31.8)
)
5.0000
4.9975
3.50 (88.9)
(Ø127 -0.063
0
(Ø63)
Y Z
2.48
B
S
DIA
▼▼ Splined shaft 1 1/2 in SAE J744 ▼▼ Splined shaft 1 1/2 in SAE J744
S ‒ 17T 12/24DP 1)
R ‒ 17T 12/24DP1)
2.13 (54)
1.10 (28)
3) 4)
7/16-14UNC-2B3) 4)
1.10 (28) 0.20
7/16-14UNC-2B 0.20(5) (5)
▼▼ Splined shaft 1 1/4 in SAE J744 ▼▼ Splined shaft 1 1/4 in SAE J744
U ‒ 14T 12/24DP1) W ‒ 14T 12/24DP1)
1.87 (47.5)
5/16-18UNC-2B3) 4)
5/16-18UNC-2B3) 4)
0.75 (19) 0.75 (19)
0.20 (5) 0.20 (5)
2.10 (53.5)
Key width
(ø38.1 -0.03)
1.10 (28)
0.3758 (9.52+0.025)
0.20 0.3748
(5)
1.6653
1.6500
DIA 1.500
1.499
(42.3 -0.4 )
2.44 (61.9)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat 3) Thread according to ASME B1.1
root, side fit, tolerance class 5 4) Observe the instructions in the operating instructions concerning
2) Splines according to ANSI B92.1a, run out of spline is a deviation the maximum tightening torques
from standard.
1) Observe the instructions in the operating instructions concerning 4) Depending on the installation position, L, L1 or L2 must be con-
the maximum tightening torques. nected (also see installation instructions starting on page 68).
2) Momentary pressure spikes may occur depending on the application. 5) Only series 53
Keep this in mind when selecting measuring devices and fittings. 6) O = Must be connected (plugged when delivered)
3) The spot face can be deeper than as specified in the standard. X = Plugged (in normal operation)
▼▼ DRG – Pressure controller, remote controlled, series 52 (53) ▼▼ EP.D. / EK.D. – Electro-proportional control, series 53
6.14 (156)
L
5.49(139.5)
X
5.91 (150)
5.59 (142)
L
5.24 (133)
S S L2
▼▼ DRF/DRS/DRSC – Pressure and flow control, series 52 (53) ▼▼ EP.ED. / EK.ED. – Electro-prop. control, series 53
X
L
5.49(139.5)
5.91 (150)
5.24 (133)
S S L2
▼▼ LA.D. – Pressure, flow and power control, series 53 ▼▼ ED7. / ER7. – Electro-prop. Pressure control, series 52 (53)
2.17 (55)
10.67 (271) 0.76 (19.4)
10.68 (271.4)
7.15 (181.5) X 2.91 (74)
L1 L1 X
6.14 (156)1)
X
5.90 (149.9)
L
5.25 (133.4)
5.71(145)
L2 S
S
▼▼ Port plate 61
0.
16
Flange
5.91 (150)
(4
)
ISO 3019-1
5)
(9
5)
0
(9
74
74
3.
DIA
0.69 (17.5)
3.
45°
0.
16
(4
)
5.12 (130) L2
9.65 (245) 7.13 (181)
8.27 (210)
View X1)
(Ø32)
1.26
3.50 (88.9)
2.36 (Ø60)
(66.7)
2.62
S B
2.00
(50.8) 1.25
▼▼ Port plate 62
1.26 (Ø32)
View Y1)
0.50 (12.7) 1.42 (36)
L1 X
Flange
ISO 3019-1 B 1.25
(31.8)
L
3.50 (88.9)
)
DIA5.0000
4.9975
(Ø127-0.063
(Ø63)
2.48
Y Z
0
B
S
▼▼ Port plate 61
0.
16
Flange
5.91 (150)
(4
4.96 (126)
ISO 3019-1
3.98 (101)
L L
45°
4.51 (114.5)
(Ø127 -0.063 )
5.0000
DIA 4.9975
5)
(9
5)
0
(9
74
74
4.04 (102.5)
3.
3.
45°
0.
16
(4
)
5.12 (130) L2
4. 6
(1 .5
3)
0
9.65 (245) 4.51 (114.5)
5.75 (146)
View X1)
1.26 (Ø32)
2.36 (Ø60)
3.50 (88.9)
(66.7)
2.62
S B
2.00
(50.8) 1.25
(31.8)
1.97 1.77
▼▼ Port plate 62
(50) (45)
Detail Z
(Ø32)
5.63 (143)
2.63 (66.7)
View Y1)
0.50 (12.7) 1.42 (36)
L1 X
Flange
ISO 3019-1
B
1.25
L (31.8)
)
3.50 (88.9)
DIA 5.0000
4.9975
(Ø127 -0.063
(Ø63)
Y Z
2.48
0
B
S
▼▼ Splined shaft 1 1/2 in SAE J744 ▼▼ Splined shaft 1 1/4 in SAE J744
S ‒ 17T 12/24DP 1)
U ‒ 14T 12/24DP1)
5/16-18UNC-2B3) 4)
3) 4) 1.10 (28) 0.75 (19)
7/16-14UNC-2B
0.20(5) 0.20 (5)
1.71
1.38
(43.5)
(35)
2.44 (61.9)
2.18 (55.4)
▼▼ Splined shaft 1 1/4 in SAE J744 ▼▼ Parallel keyed shaft (ISO 3019-1)
W ‒ 14T 12/24DP1) K ‒ 38-1
Key width
7/16-14UNC-2B 3) 4)
2.10 (53.5)
5/16-18UNC-2B3) 4)
0.75 (19)
Key width
(ø38.1 -0.03)
0.20 (5) 1.10 (28)
0.3758 (9.52+0.025)
0.20 0.3748
(5)
1.6653
1.6500
DIA 1.500
1.499
(42.3 -0.4 )
2.44 (61.9)
1) Involute spline according to ANSI B92.1a, 30° pressure angle, flat 6) The spot face can be deeper than as specified in the standard.
root, side fit, tolerance class 5 7) Depending on the installation position, L, L1 or L2 must be con-
2) Splines according to ANSI B92.1a, run out of spline is a deviation nected (also see installation instructions starting on page 68).
from standard. 8) Only series 53
3) Thread according to ASME B1.1 9) O = Must be connected (plugged when delivered)
4) Observe the instructions in the operating instructions concerning X = Plugged (in normal operation)
the maximum tightening torques.
5) Momentary pressure spikes may occur depending on the application.
Keep this in mind when selecting measuring devices and fittings.
▼▼ DRG – Pressure controller, remote controlled, series 53 ▼▼ EP.D. / EK.D. – Electro-proportional control, series 53
5.91 (150)
L
X
5.24 (133)
5.91 (150)
5.59 (142)
L
5.24 (133)
S L2 S L2
▼▼ DRF/DRS/DRSC – Pressure and flow control, series 53 ▼▼ EP.ED. / EK.ED. – Electro-proportional control, series 53
X
L L
5.91 (150)
5.24 (133)
5.24 (133)
S L2 S L2
▼▼ LA.D. – Pressure, flow and power control, series 53 ▼▼ ED7. / ER7. – Electro-proportional Pressure control, series 53
10.67 (271)
10.71 (272)
7.15 (181.5) X 2.91 (74)
L1
L1
6.14 (156)1)
X
X
5.90 (149.9)
L L
5.25 (133.4)
5.71(145)
S L2 S L2
Flange ISO 3019-1 (SAE) Hub for splined shaft1) Availability over sizes Code
Diameter Attachment2) Diameter 18 28 45 60/63 72 85 100
82-2 (A) , 5/8 in 9T 16/32DP ● ● ● ● ● ● ● K01
3/4 in 11T 16/32DP ● ● ● ● ● ● ● K52
● = Available ○ = On request
▼▼ 82-2
45°
45°
(ø82.55 +0.020)
+0.050
3.2520
DIA3.2501
A B
(ø82.55 +0.020)
+0.050
3.2520
DIA3.2501
A B
4
4.1 (10 .19
(10 9 6.5
6.5 )
)
A4
A4
0.39
0.39 (10)
Omitted for size 18 and 28 A2
Omitted for size 18 and 28 (10)
A1 (to mounting flange) A1 (to mounting flange)
1) According to ANSI B92.1a, 30° pressure angle, flat root, side fit, 3) Thread according to DIN 13, observe the instructions in the in-
tolerance class 5 struction manual for the maximum tightening torques.
2) Mounting bores pattern viewed from through drive with control at top
Flange ISO 3019-1 (SAE) Hub for splined shaft1) Availability over sizes Code
Diameter Attachment2) Diameter 18 28 45 60/63 72 85 100
101-2 (B) , 7/8 in 13T 16/32DP – ● ● ● ● ● ● K68
1 in 15T 16/32DP – – ● ● ● ● ● K04
● = Available ○ = On request
▼▼ 101-2
45°
45
+0.020 )
+0.020 )
°
(ø101.6 +0.050
(ø101.6 +0.050
A B 4.0020
DIA 4.0008 A B
4.0020
DIA 4.0008
5.7 5.7
(14 5 (14 5
6) 6)
A4 A4
0.39 0.39
Omitted for sizes 28, 45 A2 (10) Omitted for size 45 A2 (10)
A1 (to mounting flange) A1 (to mounting flange)
1) According to ANSI B92.1a, 30° pressure angle, flat root, side fit, 3) Thread according to DIN 13, observe the instructions in the in-
tolerance class 5 struction manual for the maximum tightening torques.
2) Mounting bores pattern viewed from through drive with control at
top
Flange ISO 3019-1 (SAE) Hub for splined shaft1) Availability over sizes Code
Diameter Attachment2) Diameter 18 28 45 60/63 72 85 100
127-4 (C) 1 1/4 in 14T 12/24DP – – – ● ● ● ● K15
1 1/2 in 17T 12/24DP – – – – – ● ● K16
● = Available ○ = On request
▼▼ 127-4
A3 A3
A A2 A A2
4.51 (114.5)
(ø127 +0.020 )
(ø127 +0.020 )
4.51 (114.5)
5.0020
DIA 5.0008
5.0020
DIA 5.0008
+0.050
+0.050
4.51 (114.5) A4
4.51 (114.5) A4 0.51 0.53
(13) (13.4)
B B
A1 (to mounting flange) A1 (to mounting flange)
1) According to ANSI B92.1a, 30° pressure angle, flat root, side fit, 3) Thread according to DIN 13, observe the instructions in the in-
tolerance class 5 struction manual for the maximum tightening torques.
2) Mounting bores pattern viewed from through drive with control at top
Flange ISO 3019-1 (SAE) Hub for splined shaft1) Availability over sizes Code
Diameter Attachment2) Diameter 18 28 45 60/63 72 85 100
127-2 (B) , 1 1/4 in 14T 12/24DP – – – – – ● ● K07
1 1/2 in 17T 12/24DP – – – – – ● ● K24
● = Available ○ = On request
▼▼ 127-2
45° 45° A3
A
A2 A A2
(Ø127 +0.020 )
3
5.0020
DIA 5.0008
7.1 1)
+0.050
81
(Ø127 +0.020 )
Ø1
5.0020
DIA 5.0008
+0.050
1 8
(Ø
A4 A4
B
B 0.51
A3 (13)
0.51
(13)
A1 (to mounting flange) A1 (to mounting flange)
1) According to ANSI B92.1a, 30° pressure angle, flat root, side fit, 3) Thread according to DIN 13, observe the instructions in the in-
tolerance class 5 struction manual for the maximum tightening torques.
2) Mounting bores pattern viewed from through drive with control at top
NG 10 18 28 45 60/63 72 85 100
static Tm lb-ft – 369 656 664 1010 1010 2270 2270
(Nm) (500) (890) (900) (1370) (1370) (3080) (3080)
dynamic at 10 g (98.1 m/s2) Tm lb-ft – 37 65 66 101 101 227 227
(Nm) (50) (89) (90) (137) (137) (308) (308)
Weight with through-drive plate m lbs (kg) – (–) 29 (13) 40 (18) 53 (24) 62 (28) 62 (28) 99 (45) 99 (45)
Weight without through-drive plate 8 (18) 25 (11.5) 33 (15) 40 (18) 49 (22) 49 (22) 79 (36) 79 (36)
(e.g. 2nd pump)
Distance, center of gravity l1 in – 3.07 3.35 3.78 4.13 4.13 4,80 4.80
without through drive (mm) (78) (85) (96) (105) (105) (122) (122)
Distance, center of gravity l1 in – 3.43 3.90 4.53 5.00 5.00 5.90 5.90
with through drive (mm) (87) (99) (115) (127) (127) (150) (150)
DEUTSCH DT04-2P
1.44 (36.7)
Molded connector, 2-pin, without bidirectional
suppressor diode (2)
1.44 (36.7)
The following type of protection ensues with a mounted (1)
mating connector:
DIA 1.46
▶▶ IP67 (DIN/EN 60529) and
(ø37)
▶▶ IP69K (DIN 40050-9)
Electronic controls
Control Electronics function Electronics Data sheet
Electric pressure control Controlled power outlet RA analog 95230
RC4-5/30 digital 95205
Installation instructions
S
1) Because complete air bleeding and filling are not possible in this
position, the pump should be air bled and filled in a horizontal po- L
sition before installation. L1
2) For NG10 and NG28 series 52, L1 is opposite, L must then be con-
nected if necessary.
3) Only series 53
Above-reservoir installation A check valve in the case drain line is only permissible in
Above-reservoir installation means that the axial piston unit individual cases. Consult us for approval.
is installed above the minimum fluid level of the reservoir.
To prevent the axial piston unit from draining, a height
difference hES min of at least 1 in (25 mm) is required in For key, see page 70.
position 6
Observe the maximum permissible suction height
hS max = 31.5 in (800 mm).
Installation position Air bleeding Filling
5 2)
F L1 or L
F
L
L1 X
hs max
S
ht min
SB
h min
61)2) F L1
F
hES min
L1
S L
X
hs max
ht min
SB
h min
7 3) F L2
F
L2
L1 L S
hs max
ht min
SB
h min
8 1) F S or L
F
S
L
L1
hs max
ht min SB
h min
1) Because complete air bleeding and filling are not possible in this
position, the pump should be air bled and filled in a horizontal po-
sition before installation.
2) For NG10 and NG28 series 52, L1 is opposite, L must then be con-
nected if necessary.
3) Only series 53
Installation position Air bleeding Filling hES min Minimum necessary height required to protect the axial
piston unit from draining (1 in (25 mm)
9 2) Via the high- Automatically
est available via the open hS max Maximum permissible suction height 21.50 in (800 mm)
L port L port L or L1
L1 due to the
X
SB der the hy- Port F is part of the external piping and must be provided
draulic fluid on the customer side to make filling and air bleeding easier.
S level
h min
draulic fluid
S level
h min
11 3)
L2
h t min
L S
SB
h min
position un-
der the hy-
L draulic fluid
L1
level
h min
1) Because complete air bleeding and filling are not possible in this
position, the pump should be air bled and filled in a horizontal po-
sition before installation.
2) For NG10 and NG28 series 52, L1 is opposite, L must then be con-
nected if necessary.
3) Only series 53
▶▶ The A10VO axial piston variable pump is designed to be ▶▶ Pressure controllers are not safeguards against pressure
used in open circuit. overload. Be sure to add a pressure relief valve to the
▶▶ The project planning, installation and commissioning of hydraulic system.
the axial piston unit requires the involvement of quali- ▶▶ Working ports:
fied personnel. –– The ports and fastening threads are designed for the
▶▶ Before using the axial piston unit, please read the corre- specified maximum pressure. The machine or system
sponding instruction manual completely and thoroughly. manufacturer must ensure that the connecting ele-
If necessary, request it from Bosch Rexroth. ments and lines correspond to the intended operating
▶▶ Before finalizing your design, please request a binding conditions (pressure, flow, hydraulic fluid, tempera-
installation drawing. ture) with allowance for the necessary safety margins.
▶▶ The specified data and notes must be observed. –– The working ports and function ports can only be
▶▶ Depending on the operating conditions of the axial used to accommodate hydraulic lines.
piston unit (operating pressure, fluid temperature), the
characteristic may shift. Safety instructions
▶▶ Preservation: Our axial piston units are supplied as stan-
dard with protection to preserve for a maximum of ▶▶ During and shortly after operation, there is a risk of
12 months. If longer preservative protection is required burns on the axial piston unit and especially on the
(maximum 24 months), please specify this in plain text solenoids. Take appropriate safety measures (e.g. by
when placing your order. The preservation periods apply wearing protective clothing).
under optimal storage conditions, details of which can be ▶▶ Moving parts in control equipment (e.g. valve spools)
found in the data sheet 90312 or the instruction manual. can, under certain circumstances, get blocked in posi-
▶▶ Not all variants of the product are approved for use in safety tion as a result of contamination (e.g. impure hydraulic
functions according to ISO 13849. Please consult the fluid, abrasion, or residual dirt from components). As a
responsible contact person at Bosch Rexroth if you require result, the flow of hydraulic fluid and the build-up of
reliability parameters (e.g. MTTFd) for functional safety. torque in the axial piston unit can no longer respond
▶▶ Depending on the type of control used, electromagnetic correctly to the operator’s specifications. Even the use
effects can be produced when using solenoids. When a of various filter elements (external or internal flow filter)
direct current is applied, solenoids do not cause electro- will not rule out a fault but merely reduce the risk. The
magnetic interference nor is their operation impaired by machine/system manufacturer must test whether reme-
electromagnetic interference. dial measures are needed on the machine for the appli-
Other behavior can result when a modulated direct cation concerned in order to set the consumer being
current (e.g. PWM signal) is applied. Potential electro- driven to a safe position (e.g. safe stop) and if necessary
magnetic interference for persons (e.g. persons with a to ensure it is properly implemented.
pacemaker) and other components must be tested by
the machine manufacturer.