3176C and 3196 Engines for Caterpillar Built Machines
Media Number -SENR9515-05 Publication Date -01/05/2007 Date Updated -08/05/2007
i06595732
Most electrical problems are caused by poor connections. The following procedure will assist in
detecting problems with connectors and with wiring. If a problem is found correct the condition and
verifies that the problem is resolved.
• Always use a 1U-5804 Crimp Tool to service Deutsch HD and DT connectors. Never solder the
terminals onto the wires. Refer to "SEHS9615, ServicingDeutschHDand DT Style Connectors".
• Always use a 147-6456 Wedge Removal Tool to remove wedges from DT connectors. Never
use a screwdriver to pry a wedge from a connector.
• Always use a breakout harness for a voltmeter probe or a test light. Never break the insulation
of a wire in order to access to a circuit for measurements.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 12/12/2018
16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP3329... Page 2 of 12
Illustration 1 g01131211
Leaky seal at the connector (typical example)
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 12/12/2018
16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP3329... Page 3 of 12
Illustration 2 g01131276
Diagram for the installation of a connector plug (typical example)
(1) Electronic Control Module (ECM) connector
(2) Correctly inserted plug
(3) Incorrectly inserted plug
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 12/12/2018
16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP3329... Page 4 of 12
Illustration 3 g01131019
Seal for a three-pin connector (typical example)
Illustration 4 g01131165
Seal for ECM connector (typical example)
Table 1
Troubleshooting Test Steps Values Results
1. Check Connectors for Moisture and Connectors Result: The harness wiring,
Corrosion connectors, and seals are in good
condition.
A. Inspect all wiring harnesses. Ensure that the
routing of the wiring harness allows the wires to Proceed to Test Step 2.
enter the face of each connector at a
perpendicular angle. Otherwise, the wire will Result: A problem has been
deform the seal bore. Refer to Illustration 1. This found with the harness or the
will create a path for the entrance of moisture. connectors.
Verify that the seals for the wires are sealing
correctly. Repair: Repair the connectors or
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 12/12/2018
16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP3329... Page 5 of 12
• Missing seals
2. Check the Wires for Damage to the Wiring Result: The harness is OK.
Insulation
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 12/12/2018
16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP3329... Page 6 of 12
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 12/12/2018
16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP3329... Page 7 of 12
Illustration 5 g01131435
Receptacle lock wedge (typical example)
Table 2
Troubleshooting Test Steps Values Results
A. Ensure that the locking wedge for the connector is Result: A wire has been
installed properly. Terminals cannot be retained inside pulled from a terminal or a
the connector if the locking wedge is not installed terminal has been pulled
properly. 45 N from the connector.
(10 lb)
B. Perform the 45 N (10 lb) pull test on each wire. Each Repair: Use the 1U-5804
terminal and each connector should easily withstand Crimp Tool to replace the
45 N (10 lb) of tension and each wire should remain in terminal. Replace damaged
the connector body. This test checks whether the wire connectors, as required.
was properly crimped in the terminal and whether the Verify that the repair
terminal was properly inserted into the connector. eliminates the problem.
STOP
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 12/12/2018
16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP3329... Page 8 of 12
Illustration 6 g01131604
Diagram for testing pin retention (typical example)
Table 3
Troubleshooting Test Steps Values Results
STOP
6. Check the Locking Mechanism of the Locking Result: The connectors are in
Connectors Mechanism of good repair.
the Connectors
A. Ensure that the connectors lock properly. Proceed to Test Step 7.
After locking the connectors, ensure that the
two halves cannot be pulled apart. Result: The connector's
locking mechanism is damaged
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 12/12/2018
16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP3329... Page 9 of 12
STOP
Illustration 7 g01132827
Allen head screw for the 120 pin ECM connector (typical example)
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 12/12/2018
16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP33... Page 10 of 12
Illustration 8 g01132849
Allen head screw for the 70 pin ECM connector (typical example)
Illustration 9 g01132863
Allen head screw for the 40 pin ECM connector (typical example)
Illustration 10 g01133047
Allen head screw for the 40 pin customer connector and the 70 pin customer connector (typical example)
Table 4
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 12/12/2018
16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP33... Page 11 of 12
Test Step 1.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 12/12/2018
16H Motor Grader ATS00001-UP (MACHINE) POWERED BY 3196 Engine(SEBP33... Page 12 of 12
Results:
Repair: Contact your Cat dealer Technical Communicator (TC). For further assistance, your
TC can confer with the Dealer Solutions Network (DSN).
STOP