You are on page 1of 2

Page 1 of 2

Sariyanto (SAR)

From: SOSManager [SOS.Manager@trakindo.co.id]


Sent: Friday, April 01, 2005 5:32 PM
To: Sariyanto (SAR)
Subject: OilCommander - URGENT!!! Lab No: 05D011316
Importance: High

ATT: SARIYANTO
Trakindo - Scheduled Oil Sampling
Fluid Analysis Technology Laboratorium
---------------------------------------------------
Message: Sample Details
---------------------------------------------------
SAMPLE DETAILS
---------------------------------------------------

FILE CREATED: 1/4/05 15:31:44

CURRENT SAMPLE
Customer FREEFORT INDONESIA COY. PT. : 499230X Unit No HT.353
Serial No 04GZ00165 Model 793C
Make Caterpillar Oil Type MOBIL
Oil Grade SAE.10 Compartment Hydraulic System
Lab No 05D011316 Sample Date 26/3/05
Eval C
Job Site GRASSBERG

ELEMENT TEST
Lab No Eval Mo Cr Zn Pb Fe Si Mg Cu Al Na
05D011316 C 1 1 1061 1 5 7 18 136 1 2
05B250910 B 1 1 1164 3 11 11 19 10 3 7
05A271533 B 1 1 1176 1 12 11 18 7 2 8
04L300320 A 1 1 866 1 1 5 14 5 1 17

LUBR TESTS
Lab No Eval W PC5 PC15 ISO.5 ISO.15 V100
05D011316 C N 40 7 19 17 6.4
05B250910 B N 50 14 20 18 6.3
05A271533 B N 160 2 21 15 6.1
04L300320 A N 17 2 18 14 6.4

DETAILS
Lab No Eval Date Sampled Date Received Meter Read Oil Hours Oil Added Oil Changed

4/2/2005
Page 2 of 2

05D011316 C 26/3/05 1/4/05 36629 500 N


05B250910 B 18/2/05 25/2/05 36089 1000 N
05A271533 B 20/1/05 27/1/05 35509 500 N
04L300320 A 2/12/04 30/12/04 34817 2000 Y

COMMENTS
Lab No Eval Comment
HOURS ON OIL OF SAMPLE SEEMS NOT CORRECT. THE ISO CODE
SLIGHTLY ABOVE ACCEPTABLE CLEAN LINES RANGE. CU INCREASED.
PROBABLY CAUSED BY BRASS PUMP PARTS WEAR. CHECK OIL
05D011316 C PRESSURE, INSPECT PUMP FOR UNUSUAL NOISE. CHANGE FILTER,
RESAMPLE AT 750 HOURS ON OIL. CUT OPEN FILTER AND INSPECT FOR
LARGE PARTICLES. PLEASE SUPPLY CORRECT DATA TO GET ACCURATE
RESULT.
THE ISO CODE SLIGHTLY ABOVE ACCEPTABLE CLEAN LINES RANGE.
05B250910 B CHANGE FILTER, RESAMPLE AT 1250 HOURS ON OIL. CUT OPEN FILTER
AND INSPECT FOR LARGE PARTICLES.
THE LARGE PARTICLE COUNTS INCREASED, CHECK OIL LEVEL,
BREATHER, SEALS/ GASKET FAILURE. CHANGE FILTER, RESAMPLE AT
05A271533 B
750 HOURS ON OIL. CUT OPEN FILTER AND INSPECT FOR LARGE
PARTICLES.
ALL TESTS APPEAR NORMAL. RESAMPLE WHEN HOURS ON OIL REACH
04L300320 A 250 HOURS. PLEASE SEND SAMPLE SOON AFTER TAKEN. DO NOT KEEP
IT TOO LONG.

---------------------------------

For full details click here

4/2/2005

You might also like