- Analysis Design Standard : TIA-222-G Structure Class 2, Top Cat 1, Exposure C - Software : MS Tower v6.20.2.4 - Maximum Wind Load : 100 km/h (27.78 m/s) - Operational Wind Load : 70 km/h (19.44 m/s)
No Description Struktur Reserve Loading
Leg <1 0.585 Ok Horizontal <1 0.216 Ok 1 Bracing <1 0.272 Ok Guy Wire <1 0.174 Ok Twist ≤ 1.0 degrees 0.127 Ok 2 Sway ≤ 1.0 degrees 0.170 Ok Disp ≤ (42/100)= 0.420 m 0.043 m Ok Uplift Reaction (Guy Wire) : Description Fx (kN) Fy (kN) Fz (kN) Recommended 2.939 2.939 24.406 Update Loading 3.203 3.203 24.801 The new uplift Reaction is above from the standard loading, Safety Factor > 1.50, Counterweight still strong enough to support update loading Catatan Khusus : - ARM C sudah ditambahkan counterweight dengan berat total 500 kg - ARM B sudah ditambahkan counterweight dengan berat total 250 kg