Professional Documents
Culture Documents
Foundation loads
Perm anent surcharge load; F Gsur = 5.0 kN/m 2
Variable surcharge load; F Qsur = 5.0 kN/m 2
Self weight; F swt = h conc = 36.8 kN/m 2
Moments on foundation
Moment in x-axis; M dx = A (F swt + F Gsur + F Qsur) L x / 2 + F Gz1 x 1 + F Gz2 x 2 + F Gz3 x3
+ F Gz4 x 4 = 2147.6 kNm
Moment in y-axis; M dy = A (F swt + F Gsur + F Qsur) L y / 2 + F Gz1 y 1 + F Gz2 y 2 + F Gz3 y3
+ F Gz4 y 4 = 5015.3 kNm
q 2 = 227.9 kN/m 2
q 3 = 0 kN/m 2
q 4 = 52.7 kN/m 2
Minim um base pressure; q min = min(q 1 , q 2 , q 3 , q 4 ) = 0 kN/m 2
Maxim um base pressure; q max = max(q 1 , q 2 , q 3 , q 4 ) = 227.9 kN/m 2
Presumed bearing capacity
Presumed bearing capacity; P bearing = 1800.0 kN/m 2
PASS - Presumed bearing capacity exceeds design base pressure
Design approach 1
Partial factors on actions - Combination1
Partial factor set; A1
Perm anent unfavourable action - Table A.3; G = 1.35
Perm anent favourable action - Table A.3; Gf = 1.00
Variable unfavourable action - Table A.3; Q = 1.50
Variable favourable action - Table A.3; Qf = 0.00
Forces on foundation
Force in z-axis; F dz = G (A (F swt + F Gsur) + F Gz1 + F Gz2 + F Gz3) + Gf F Gz4 + Q A
F Qsur = 2305.1 kN
Moments on foundation
Moment in x-axis; M dx = G (A (F swt + F Gsur) L x / 2 + F Gz1 x 1 + F Gz2 x2 + F Gz3 x3 ) +
Gf F Gz4 x4 + Q A F Qsur L x / 2 = 3785.6 kNm
Moment in y-axis; M dy = G (A (F swt + F Gsur) L y / 2 + F Gz1 y 1 + F Gz2 y 2 + F Gz3 y 3) +
Gf F Gz4 y4 + Q A F Qsur L y / 2 = 7471.3 kNm
Forces on foundation
Force in z-axis; F dz = G (A (F swt + F Gsur) + F Gz1 + F Gz2 + F Gz3) + Gf F Gz4 + Q A
F Qsur = 1508.7 kN
Moments on foundation
Moment in x-axis; M dx = G (A (F swt + F Gsur) L x / 2 + F Gz1 x 1 + F Gz2 x2 + F Gz3 x3 ) +
Gf F Gz4 x4 + Q A F Qsur L x / 2 = 2224.5 kNm
Moment in y-axis; M dy = G (A (F swt + F Gsur) L y / 2 + F Gz1 y 1 + F Gz2 y 2 + F Gz3 y 3) +
Gf F Gz4 y4 + Q A F Qsur L y / 2 = 5101.7 kNm
Concrete details (Table 3.1 - Strength and deformation characteristics for concrete)
Concrete strength class; C20/25
Characteristic com pressive cylinder strength; fck = 20 N/mm 2
Characteristic com pressive cube strength; fck,cube = 25 N/mm 2
Mean value of com pressive cylinder strength; fcm = f ck + 8 N/mm 2 = 28 N/mm 2
Mean value of axial tensile strength; fctm = 0.3 N/mm 2 (f ck / 1 N/mm 2) 2/3 = 2.2 N/mm 2
5% fractile of axial tensile strength; fctk,0.05 = 0.7 f ctm = 1.5 N/mm 2
Secant m odulus of elasticity of concrete; E cm = 22 kN/mm 2 [f cm /10 N/mm 2 ] 0.3 = 29962 N/mm 2
Partial factor for concrete (Table 2.1N); C = 1.50
Project Job no.
Reach Block A NXR.BCJV.693
Calcs for Start page no./Revision
Crane Base Case 1 - Very short term (with crane but no core) 5
Calcs by Calcs date Checked by Checked date Approved by Approved date
SC 28/01/2020 AF
Reinforcement details
Characteristic yield strength of reinforcement; fyk = 500 N/mm 2
Modulus of elasticity of reinforcem ent; E s = 210000 N/mm 2
Partial factor for reinforcing steel (Table 2.1N); S = 1.15
Design yield strength of reinforcement; fyd = f yk / S = 435 N/mm 2
Nominal cover to reinforcement; c nom = 50 m m
Shear diagram , x axis (kN)
0.5
Lever arm ; z = min(0.5 + 0.5 (1 - 2 K/( cc / C )) , 0.95) d = 1342 mm
Depth of neutral axis; x = 2.5 (d - z) = 177 mm
Area of tension reinforcem ent required; A sy.bot.req = M Ed.y.max / (f yd z) = 1203 mm 2
Tension reinforcement provided; 23 No.25 dia.bars bottom (200 c/c)
Area of tension reinforcem ent provided; A sy.bot.prov = 11290 m m 2
Minim um area of reinforcement (exp.9.1N); A s.min = m ax(0.26 f ctm / f yk , 0.0013) Lx d = 8263 mm 2
Maxim um area of reinforcem ent (cl.9.2.1.1(3)); A s.max = 0.04 Lx d = 254250 mm 2
PASS - Area of reinforcement provided is greater than area of reinforcement required
Crack control (Section 7.3)
Limiting crack width; w max = 0.3 m m
Variable load factor (EN1990 – Table A1.1); 2 = 0.3
Serviceability bending mom ent; M sls.y.max = 686.6 kNm
Tensile stress in reinforcement; s = M sls.y.max / (A sy.bot.prov z) = 45.3 N/mm 2
Load duration factor; k t = 0.6
Effective depth of concrete in tension; h c.ef = min(2.5 (h - d), (h - x) / 3, h / 2) = 219 m m
Effective area of concrete in tension; A c.eff = h c.ef L x = 984375 m m 2
Mean value of concrete tensile strength; fct.eff = f ctm = 2.2 N/mm 2
Reinforcem ent ratio; p.eff = A sy.bot.prov / A c.eff = 0.011
Modular ratio; e = E s / E cm = 7.009
Bond property coefficient; k 1 = 0.8
Strain distribution coefficient; k 2 = 0.5
k 3 = 3.4 =3.4
k 4 = 0.425
Maxim um crack spacing (exp.7.11); s r.max = k 3 (c nom + x.bot ) + k1 k2 k4 y.bot / p.eff = 626 mm
Maxim um crack width (exp.7.8); w k = s r.max max([ s – kt (f ct.eff / p.eff) (1 + e p.eff )] / E s,
0.6 s / E s ) = 0.081 m m
PASS - Maximum crack width is less than limiting crack width
Library item: Crack width output