1. For general notes refer to drawing nos. SD-NT, SD-01, SD-02. ----- sheet of -----
2. Read this drawing in conjunction with other relevant
8-1 8-2 8-3 8-4 8-5 8-6 8-7 8-8 Structural drawings.
8825 2350 7400 5250 1525 5550 8050 3. Contractor is required to verify all dimensions with Architectural
and M&E drawings prior to construction. BUILDING AND CONSTRUCTION AUTHORITY
APPROVED UNDER SECTION 5 / SECTION 5A OF THE
8-T2 BUILDING CONTROL ACT (CHAPTER 29)
FP8-T
(200) 150 725 150
150 725 150
4C1b4 200THK NON STRUCTURAL PRECAST WALL 4C1a7 Project Ref No. A1716-00002-2019 ST06
4C1b6 (200) 4C1a4
350x575 TBD1b3 350x550 350x550 TBD1a2 350x575
TBD1b1-1 TBD1b1-2 TBD1b2 TBD1a4-1 TBD1a4-2
8-A TBD1a3 Variable Action
75
75
(150x600) (150x600) TBD1b4 TBD1a1 (150x600) (150x600) Description
150
150
(kN/m2)
50
4W1b8 4W1a2
2100
Corbel B1 Corbel B1 Corbel B1 Corbel B1
3500
2350
3250
4W1a6 (150) Residential unit (except balcony) 2.0
2800
2800
(350x600) (350x600) (350x600) (350x600)
2645
2650
(150) 4W1a9
4W1b5 Lift Lobby, Staircase, Corridor, Balcony 3.0
4W1b2
50
50
D1b D1a
Lift motor room, all M&E rooms 7.5
BHS1a
175 1705
175 1700
4W1b1 Corbel B2 Corbel B2
9175
(175x600) (handed) (175x600) RC flat roof (accessible for maintenance only) 1.5
4W1a10
50
50
4W1b9 4W1a3 (150)
4250 150
TBD1a8
(150) WHSD1b WHSD1a 400 150
TBD1b7
175 3000 3200 3000 175
4W1a11
775 150
2000
2000
775150
150
125 4W1b3 4W1a11 4W1a8 125
TBD1b8
175
175
TBD1a7
300
TBD1b5-1 TBD1a5 TBD1a6-2
175
(150) 4W1b7 (150)
(150x600) 4W1a5 (150x600)
2100
4W1b10 4W1a1 500
300
8-B
TBD1b5-2c (150x600) 6125 1575 1200 4850 TBD1a6-1c (150x600) 8-A
50
50
1525
175
FP8-T 150
8WL1 DN 1000 150
50
50
ST_FP_3RD STOREY (TYPICAL) ST_FP_3RD STOREY (TYPICAL)
UP
150
150
150
600
600
RC
BEAM TBD1b1-1
RC LEDGE RC BEAM
8850
RC WALL RC WALL
4W1a1
C1b BHS1b C1a1 4W1b3
(handed) (handed)
(handed) Section 8-T1 Section 8-T2
400 0 400 800 1200 1600 2000 400 0 400 800 1200 1600 2000
SCALE 1: 40 mm SCALE 1: 40 mm
8-D
SCALE 1: 150 m
SOH LIAN SENG
NOTE in AC Organisation
UNLESS OTHERWISE SHOWN. Registration No: A061
1. ALL WALLS = 200 THK FRAMING PLAN UNIT TYPE REFERENCES
BUILDING CONTROL ACT
2. ALL HS WALLS = 250 THK TYPE REFER TO BLOCK DRG NO. SINGAPORE
3. ALL BEAMS = 200x600 C1a1 B7 FP7-T
4. ALL SLABS = 200 THK BHS1a, BHS1b
5. ALL WALLS TO BE PRECAST. C1b B5 FP5-T
ENGINEER'S SIGNATURE
6. ALL HS WALLS TO BE PRECAST. LIFT LOBBY
7. ALL STAIRCASE TO BE PRECAST.
LEGEND
DENOTES CAST IN-SITU WALL / COLUMN
L
I ON A EN
S G
S
FE
IN
8-A
P RO
EER
CIVIL
TAN CHEE HEAN
3707
D1b D1a S IN
BHS1a GA P O RE
9175
(handed)
SUBMISSION
P & T CONSULTANTS PTE LTD
Structural & Civil Engineers
8-B 1303, CLIFFORD CENTRE TEL: 65352011
1525
DN PROJECT
(200)
2-LB1
UP
PROPOSED RESIDENTIAL FLAT DEVELOPMENT
COMPRISING OF 4 BLOCKS OF 9-STOREY AND 9
BLOCKS OF 5-STOREY (TOTAL: 633 UNITS) AND
8850
m
7.5
SE1820 FP8-T
SCALE 1: 150 REVISION: