SRUJAN GROUP STANDARD OPERATING PROCEDURE

W-26/27/28/17,MIDC,Ambad,Nashik-10 FRM/QAD/14 Rev.No.0


Part Shaft Part No. N/A SOP No. SE/SOP/80
Name
Fixture No. N/A Rev.No. 0
Process: GLM M/C operating process CP No. ALL
Machine : N/A Skill Level L3
Size Detail of Tool Insert DNMG
Accessory Detail Collet/Other Etc. N/A
Instrument/Gauge used for Measurement Vernier.Micrometer,Depth Vernier,
Sr Instruction
1 maiSanacaa AajaUbaajaUcaa pirsar caok krNao.
2 kulaMT Aa^[-la‚h^ayaD`ailak Aa^[-la caok krNao kmaI Asalyaasa laovhla
krNao slaa[-D lyaUba`IkoSana krNao‚garja Baasalyaasa badlaNao.
3 Tula [nsaT-caI kMDISana caok krNao‚garja Baasalyaasa irSaap-naIMga krNao
Aqavaa badlaNao.
4 gaojaosa k^laIba`oSana kolaolao Aaho kI naaih yaacaI Ka~I krNao.
5 maSaInavar jao jaa^ba Plaana kolao Aahot naa yaacaI Ka~I krNao.
6 D/a[-Mga‚kMT/aola Plaana maQyao dSa-ivalyaap`maaNao pihlaa jaa^ba caok
7 krNao Quality‚Group leader,Senior Person ikMvaa Production kDuna
8 Approval GaoNao.
jaa^ba Aaoko Asalyaasa pUZcao Production caalau krNao.
9 kMT/aola Plaana maQyao dSa-ivalaolyaa Frequency nao jaa^ba caok krNao va
10 Inprocess Inspection Register (REG/QAD/02) maQyao roka^D- krNao.
11 maayak`aomaITr dr caar tasaaMnaI maasTr laavaUna caok krNao.
12 Ok,Rejected,Rework jaa^ba yaaogya tao T^ga laavaUna yaaogya %yaa jaagaI
zovaNao.
13 Tula‚[nasaT- yaaogya %yaa Frequency nao caoMja krNao.
iSaFT maQyao Jaalaolyaa Ok,Rejected,Rework jaa^bacaI Production Report
14 maQyao Entry krNao
kama krtaMnaa kaih p`ablaoma Asalyaasa ga`UpilaDr Aqavaa p`a^D@Sana
[nacaaja-laa kLivaNao. kama saMpivalyaanaMtr maSaIna vyavasqaIt saaf
krNao.
maSaIna saaoDNyaapUvaI- dusayaa iSaFTmaQaIla Aa^proTrlaa BaoTuna
AavaSyak tI maaihtI doNao.

Prepared By :Nilesh Jadhav Approved By