Professional Documents
Culture Documents
Calculation Sheet For Assistant Professor
Calculation Sheet For Assistant Professor
Fck 20
Fe 500
Input
Assume
Axial Load Column Factored Soil Bending
Footing
Dimension Pressure Moment
Dia of Size
Footing Joint ID Bar q=Pf/Area of
P a b L B Footing Mu
Provided
KN m m mm m m KN/m2 KNm
1 13 270.00 0.35 0.35 16 1.50 1.50 180.00 44.63
2 14 483.00 0.35 0.35 16 1.90 1.90 200.69 114.51
3 15 593.00 0.35 0.35 16 2.10 2.10 201.70 162.15
Check for 2 way shear
Assume
Depth Permissibl
Actual Factored Nominal
Effective Overall Area of e
Spacing Area of Shear Shear K
Depth Depth Steel Shear
Steel Force Stress
d Stress
KN N/mm2 % N/mm2
safe 47.25 0.08 0.26 0.36 safe
safe 120.88 0.14 0.26 0.36 safe
safe 176.63 0.18 0.26 0.36 safe
0.966666667
Design of Isolated Footin
Fck 20 Cover 50
Fe 500
Input
KN KN KN/m2 m m mm
Front 1 276.00 414.00 120 0.30 0.30 12
Corner 2 334.00 501.00 120 0.30 0.30 12
Side 3 438.00 657.00 120 0.30 0.30 12
Middle 4 160.00 240.00 120 0.30 0.30 12
m2 m m KN/m2
2.53 1.60 1.40 1.40 1.96 4.75 211.22
3.06 1.80 1.40 1.40 1.96 4.75 255.61
4.02 2.10 1.50 1.50 2.25 5.00 292.00
1.47 1.30 1.50 1.50 2.25 5.00 106.67
0.966666667
Check for 1 way shear
Precentage Permissible
Check
of steel Shear Strength
% N/mm2
0.14 0.28 safe
0.14 0.28 safe
0.14 0.28 safe
0.16 0.28 safe
Input
KN KN KN/m2 m m mm
Front 1 29.00 43.50 65 0.30 0.30 12 0.80
Corner 2 50.00 75.00 65 0.30 0.30 12 1.00
Side 3 144.00 216.00 65 0.30 0.30 12 1.60
Middle 4 151.00 226.50 65 0.30 0.30 12 1.60
m m KN/m2 KNm mm mm mm
0.90 0.90 53.70 2.18 29.59 200 250
1.00 1.00 75.00 4.59 40.80 200 250
1.60 1.60 84.38 28.52 80.36 250 300
1.60 1.60 88.48 29.91 82.29 250 300
KN N/mm2 % N/mm2
safe 4.83 0.03 0.30 0.36 safe
safe 11.25 0.06 0.30 0.36 safe
safe 54 0.14 0.25 0.36 safe
safe 56.63 0.14 0.25 0.36 safe
0.966666667
Design of Isolated Footing
Fck 20 Cover 50
Fe 500
Input
KN KN KN/m2 m m mm
Front 1 29.00 43.50 65 0.30 0.30 12 0.80
Corner 2 105.00 157.50 65 0.30 0.30 12 1.40
Side 3 188.00 282.00 65 0.30 0.30 12 1.80
Middle 4 228.00 342.00 65 0.30 0.30 12 2.00
m m KN/m2 KNm mm mm mm
0.90 0.90 53.70 2.18 29.59 200 250
1.40 1.40 80.36 17.02 66.36 200 250
1.80 1.80 87.04 44.06 94.18 250 300
2.00 2.00 85.50 61.77 105.79 250 300
KN N/mm2 % N/mm2
safe 4.83 0.03 0.30 0.36 safe
safe 39.38 0.14 0.30 0.36 safe
safe 78.33 0.17 0.25 0.36 safe
safe 102.6 0.21 0.25 0.36 safe
0.966666667
Design of Isolated Footing
Fck 20 Cover 50
Fe 500
Input
KN KN KN/m2 m m mm
Front 1 29.00 43.50 65 0.30 0.30 12 0.80
Corner 2 50.00 75.00 65 0.30 0.30 12 1.00
Side 3 152.00 228.00 65 0.30 0.30 12 1.70
Middle 4 160.00 240.00 65 0.30 0.30 12 1.70
m m KN/m2 KNm mm mm mm
0.90 0.90 53.70 2.18 29.59 200 250
1.00 1.00 75.00 4.59 40.80 200 250
1.70 1.70 78.89 32.86 83.68 250 300
1.70 1.70 83.04 34.59 85.86 250 300
KN N/mm2 % N/mm2
safe 4.83 0.03 0.30 0.36 safe
safe 11.25 0.06 0.30 0.36 safe
safe 60.35 0.14 0.25 0.36 safe
safe 63.53 0.15 0.25 0.36 safe
0.966666667
Design of Isolated Footing
Fck 20 Cover 50
Fe 500
Input
KN KN KN/m2 m m mm
Front 1 33.00 49.50 65 0.40 0.40 12 0.80
Corner 2 133.00 199.50 65 0.40 0.40 12 1.60
Side 3 207.00 310.50 65 0.40 0.40 12 1.90
Middle 4 342.00 513.00 65 0.40 0.40 12 2.50
m m KN/m2 KNm mm mm mm
0.90 0.90 61.11 1.72 26.30 200 250
1.60 1.60 77.93 22.44 71.29 200 250
1.90 1.90 86.01 45.96 93.62 250 300
2.50 2.50 82.08 113.12 128.04 250 300
KN N/mm2 % N/mm2
safe 2.75 0.02 0.30 0.36 safe
safe 49.88 0.16 0.30 0.36 safe
safe 81.71 0.17 0.25 0.36 safe
safe 164.16 0.26 0.25 0.36 safe
0.966666667
Footing Size and Reinforcement
Reinforcement
Depth of Footing
X-X direction Y-Y direction
D