You are on page 1of 1
aR) Ingersoll Rand Instruction Sheet Installation, Operation & Maintenance Instructions For Model EDV-2000 Electric Condensate Drains The EDV-2000 removes condensed water and ol from the ait receiver tank. Additonal drains may be installed threughout your Comaressed air system, including aftercooler, fiters, dp legs and dryers. ‘The EDV-2000 operates on a timer which can be set to ‘automatically drain the air receiver tank at operator-determined intervals Key features include ‘ (© 100% continuous duty NEMA 4 enclosure ‘© Adjustable tie on (5 © Adjustable ime off (5-45 minutes) ‘© Stainless steel operator — © LED to indicate electrical power is on 10 seconds) '# LED to nsicate valve is open (@ Manual override 196 power cord (AC plug on 110/220 volt drains only) ‘© Agency approval RECEIPT & INSPECTION ‘Remove the EDV-2000 from packaging and inspect for Utansportation damage. Ensure ihe vohage rating onthe solenoid valve matches your power supply. TSN ‘On compressors that have been in service without an automatic Grain. all debris atthe bottom of the tank should be cleaned and blow out before instaling the elecivie drain, WARNING: DO NOT install the EDV-2000 on a pressurized tank. Depressurize the tank and disconnect the power Supply before installing be necessary to ing equipment 41. Install EDV-2000 using proper sealant. Loctte 567) on the threads. Ensure sealant doesnot eter the valve body. 2._Supply EDV:2000 withthe proper electrical supply vaiage. Paw ‘CAUTION: Do not operate the EDV.2000 outside the following pressure snd temperature ranges: Maximum Operating Pressure: 250 p83 Compressed Air Temperature, 3310 285°F ‘Ambient Temperature: Bio 25 4. Open the stiainer ball vive, Strainer Ball Valve. OPEN 1} C@ ‘CLOSED, 2. Set the “time off and "time on” knobs. See TIMER SETTINGS {below} foran explanation of the setings 3. During compressor operation, check for air leaks. aS The "ime offsetting determines the interval between cycles from 30 seconds to 45 minutes. The "ime on” setting determines the ‘actual time the compressor drains condensate from the 1/4" of 1/2 Condensate outiet port. The timer’ cycle rate and drain opening time should be adjusted to open just long enough to discharge the conensate. The timer is Properly set when itopens and discharges condensate and then Vents al for approximately one second before closing. Adjustments mmay'be made depending on many factors. including hurdity and duly eycle. En Trouble cause Action Valve wil ot close. __1. Debris solenoid __ 1. Remove slenoig awe povents ie Sansa Slapniogm tom ‘ean an seating feassemble 2 Shonim lacie! 2. check an pice ‘omer wil not activate, 1. No lectiealsuppy. 4. Apply power 2. Timer matuncion 2, Replace timer 3. Clogged port 3 Clean valve 4 Soleo wae 4. Replace soenad & Clogged strainer. 5. Clean strainer TAM NOTE: The following maintenance schedule has been sloped for typical applications. Maintenance intervals, ‘shouldbe shortened in harsher environments. DRAIN VALVE MAINTENANCE SCHEDULE DAILY est the vaive tor proper operon [ean the tts screen i no6de3 [clean the titer screen, MONTHLY (EVERY 30 DAYS) To clean the fier screen, perform the following steps: 1. Close the sain ba va completely tool tom te ai recewver tan 2._ Press the TEST button on the timer to vent the pressure remaining In tho valve. Repeat unt all pressure is removed CAUTION! High pressure air can cause injury from flying ebris,Engure the strainer bail vive le completely id from the valve prior to 3. Remove te pug om the sainer wih a sutabe wrench you ‘i escaping from the cleaning por, STOP IMMEDIATELY and ‘slope t and 2 4. Remove the stainless ste! fiter screen and clean it Remove any debris nat may be n the stvainer body before replacing the fier 5. Replace plug and tighten with wrench, '6. When putting the EDV.2000 back nto service, press the TEST button fo confirm proper funcion, 08512561 Form SCD-879C February 2008

You might also like