You are on page 1of 106

US Army Corps

of Engineers
Hydrologic Engineering Center

Assessment of Structural
Flood-Control Measures on
Alluvial Fans

October 1993

Approved for Public Release. Distribution Unlimited. PR-24


REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188

The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching
existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this
burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to the Department of Defense, Executive
Services and Communications Directorate (0704-0188). Respondents should be aware that notwithstanding any other provision of law, no person shall be
subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.
PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ORGANIZATION.
1. REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 3. DATES COVERED (From - To)
October 1993 Project Report
4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER
Assessment of Structural Flood-Control Measures on Alluvial Fans
5b. GRANT NUMBER

5c. PROGRAM ELEMENT NUMBER

6. AUTHOR(S) 5d. PROJECT NUMBER


CEIWR-HEC
5e. TASK NUMBER

5F. WORK UNIT NUMBER

7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER


Federal Emergency Management Agency PR-24
500 C Street, S.W.
Washington, D.C. 20472
9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/ MONITOR'S ACRONYM(S)
US Army Corps of Engineers 11. SPONSOR/ MONITOR'S REPORT NUMBER(S)
Institute for Water Resources
Hydrologic Engineering Center (HEC)
609 Second Street
Davis, CA 95616-4687
12. DISTRIBUTION / AVAILABILITY STATEMENT
Approved for public release; distribution is unlimited.
13. SUPPLEMENTARY NOTES
.
14. ABSTRACT
This report documents flood experiences with flood-control structures on alluvial streams. While the emphasis is on
alluvial fans, many of the potential flood hazards and performance problems for fans are the same as those on alluvial
stream projects throughout the Southwest. It is intended that documented flood problems will lead to an awareness of
potential causes for failure, and the required analyses to quantify important design parameters.

15. SUBJECT TERMS


structural, flood control measures, alluvial fans, geomorphology, floods, case study, debris flow, debris barriers, flood
detention basins, channels, diversion, bypasses, multi-purpose, levee, floodwalls
16. SECURITY CLASSIFICATION OF: 17. LIMITATION 18. NUMBER 19a. NAME OF RESPONSIBLE PERSON
a. REPORT b. ABSTRACT c. THIS PAGE OF OF
ABSTRACT PAGES
U U U 19b. TELEPHONE NUMBER
UU 106
Standard Form 298 (Rev. 8/98)
Prescribed by ANSI Std. Z39-18
Assessment of Structural
Flood-Control Measures on
Alluvial Fans

October 1993

Prepared for:
Federal Emergency Management Agency
500 C Street, S.W.
Washington, D.C. 20472

Prepared by:
US Army Corps of Engineers
Institute for Water Resources
Hydrologic Engineering Center
609 Second Street
Davis, CA 95616

(530) 756-1104
(530) 756-8250 FAX
www.hec.usace.army.mil PR-24

You might also like