MasterProtect® 300 (formerly known as MasterSeal 300H)

High build, Crack-bridging, Elastomeric, protective and waterproof coating for Concrete & Masonry

DESCRIPTION PROPERTIES
MasterProtect 300 is a single component, high
Aspect : Viscous Dispersion
performance, acrylic resin based coating for long
term protection of concrete & masonry from Consistency: : Thick paste
aggressive atmospheric gases such as, carbon Density: : 1.35 ± 0.05 kg/litre
dioxide, sulphur dioxide and chloride ions. It is Volume Solids : 46%
available in standard pastel colours. It can be Application temperature : 5°C to 40°C
made available in custom colours subject to prior : 300 μ
DFT at 0.9 Kg/m²
agreement.
Touch dry : 1 Hour at 25°C
RECOMMENDED USES Recoatable: : 4 Hours at 25°C
Full Care : 7 Days
MasterProtect 300 is recommended for external
protection of concrete to prevent ingress of
atmospheric corrosive gases, wind driven rain, Elongation, (ASTM D 638) : >300%
and water borne chlorides. Tensile strength, (ASTM D : > 2.5 MPa
• Applications include protection of: 638)
Adhesion, (AS 1580 : 4/5 (excellent)
• Bridges, Flyovers, Aqueducts, viaducts
408.2)
• Residential & Commercial Buildings Dirt pickup (AS 1580 : 1 (0 = ‘no dirt
• Multi storey car parks & podiums 481.1.4, 12 months), on a retained’)
• Chimneys, cooling towers and silos. scale of 0-5
Water vapour permeability : 26.0 g/m2/24
• Jetties and berths.
(DIN 52615) Hours
• Overhead water tanks.
• Industrial buildings and power plants. Chloride ion diffusivity : 4.98 x 10-10 cm²/s
MasterProtect 300 is not recommended for Reduction in chloride ion : 97% at 28 Days
application in areas likely to be submerged in ingress
water and on floors subjected to traffic
CO2 diffusion resistance : > 50m
FEATURES AND BENEFITS Equivalent air layer
thickness, R
• Anti-carbonation and sulphate coating - Appearance after 2000 hr : No colour change
High resistance to CO2 & SO2 diffusion. accelerated weathering or chalking
• Resistant to diffusion of chloride ions –
suitable for marine applications. APPLICATION
• UV resistant – suitable for exposure. New masonry and concrete should be at least 14
• Resists water ingress and permeable to days old before treatment and with moisture level in
water vapour – suitable for exposure to substrate below 7% by volume.
splashes or wind driven rain Surface preparation
• Resists dirt pick up, and growth of fungus Correct substrate preparation is critical for optimum
– suitable for use in the tropics performance. The surface to be treated must be
• MasterProtect 300 – copes with thermal thoroughly cleaned. Remove all traces of formwork,
movements of buildings. release agent, grease, efflorescence, laitance,
• Washable - coating with excellent durability algae or other contaminant that may prevent proper
adhesion. Remove organic materials by scraping,
brushing or high pressure water cleaning. Spores
MasterProtect® 300 (formerly known as MasterSeal 300H)

must be treated with a suitable fungicide sterilizing least 5ºC, and will not fall below 5ºC with-in 24
agent and carefully rinsed. hours. To avoid condensation which influences
On non-decorated concrete surface containing the adhesion negatively, surface temperature
blow holes and/or minor irregularities, and on during application should be at least 3ºC higher
some rough rendered or dashed surface, it is then the dew point.
advantageous to use MasterEmaco N5100 to Curing
close the surface, thus preventing the possibility MasterProtect 300 is self-curing.
of pinholes occurring. Cracks wider then hairline
should be patched using MasterBrace 1438 or Equipment
sealed using acrylic caulk before treatment. Airless sprayer, medium nap roller or brush.
Priming ESTIMATING DATA
Prime the surface using Masterseal 399 or The coverage rate is strongly influenced by the
MasterKure 181 as primer. roughness and porosity of the substrate. Minimum
Allow the primer to dry for 2-3 hr (at temp. >25ºC) recommended rate of application for
before applying MasterProtect 300. At lower MasterProtect 300 is 0.45 Kg/m2/coat. Each pack
temperatures, allow a longer time to dry. of 25kg is sufficient for an area of 28 m2 to achieve
the recommended final dry film thickness of 300μ.
Note: If MasterKure 181 is used as the curing
membrane, priming may not be required. Contact PACKAGING
BASF for advice. MasterProtect 300 is available in 20 litres
Mixing containers.
MasterProtect 300 is ready for use. Stir (do not SHELF LIFE
dilute) to obtain a uniform mixture before use. Store under cover, out of direct sunlight and protect
Application from extremes of temperature. In tropical climates
Apply MasterProtect 300 in one coat using the product must be stored in an air conditioned
airless spray to achieve a wet film thickness of environment.
650μ or in two coats each of 325μ WFT using Shelf life is 12 months when stored as above.
roller or brush, with the second coat applied 2 – 4
PRECAUTIONS
hrs after the first and at right angle to it. The
prepared substate must be air-dry when the first For the full health and safety hazard information
coat is applied. Where a textured finish is and how to safely handle and use this product,
required use a medium nap roller to apply the please make sure that you obtain a copy of the
product and over roll with a textured roller to give BASF Material Safety Data Sheet (MSDS) from our
the desired finish in one direction only. office or our website.
Only apply MasterProtect 300 when the ambient
temperature and substrate temperature are at

® = registered trademark of BASF group in many countries MasterProtect_300 asean v3-0415

The technical information and application advice given in this BASF Construction Chemicals publication are based
on the present state of our best scientific and practical knowledge. As the information herein is of a general nature,
STATEMENT OF no assumption can be made as to a product's suitability for a particular use or application and no warranty as to
RESPONSIBILITY its accuracy, reliability or completeness either expressed or implied is given other than those required by law. The
user is responsible for checking the suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF
NOTE Construction Chemicals either orally or in writing may be followed, modified or rejected by the owner, engineer or
contractor since they, and not BASF Construction Chemicals, are responsible for carrying out procedures
appropriate to a specific application.

BASF Construction Chemicals offices in ASEAN


Singapore Malaysia Indonesia Thailand Vietnam Philippines
Tel :+65-6861-6766 Tel :+60-3-5628-3888 Tel: +62-21-2988-6000 Tel :+66-2769-8564 Tel :+84-650-3743-100 Tel : +63-2-811-8000
Fax :+65-6861-3186 Fax :+60-3-5628-3776 Fax: +62-21-2988-5935 Fax :+66-2769-8584 Fax :+84-650-3743-200 Fax : +63-2-838-1025

Website : www.master-builders-solutions.asia-pacific.basf.com