Checking Spindle Motor Windings How To Check for Bad Windings in a Spindle Motor Testing for short to ground Using Ohm meter: Disconnect all power from machine. Check all three wires singly T1,72,73 (all three phases) to the ground wire, Readings should be infinite. If its zero or reads any continuity at all, then a problem exists with either the ‘motor or cable . If itis go directly to the motor and disconnect from cable and check motor and the cable separately. Be sure to make sure leads on both ends are net touching anything including the other leads. Most servo motor shorts can be read with a regular quality meter. Make sure you use quality meter going up to at least 10megohms. Using Megohm meter: Disconnect all power from machine. Check all three wires separately T1,T2,T3 (all three phases) to the ground wire. Readings are usually in a range from 600-2000 Megohms. Most shorts will be below 20 megohms. Be careful not to touch the leads or the wires to anything when taking the reading. it can give false and unrepeatable readings causing you to chase your tale. The above is what | found to be the average for 230VAC 3 phase motors. A rule of thumb that I've come across in other reference materials is about 1000 ohms of resistance for each volt of incoming power. Though 230meg for a 230V/AC circuit seems on the low side from my experience. Only use this as a rule of thumb. Just beware that from 230meg to 600meg often shows some deterioration in the cables or motor insulation. Testing for Open or short in windings Using Ohm meter: Disconnect all power from machine. Put meter on ohms: T1 to T2T2 to T3 T1 to T3 The range usually expected is .3 to 2.0 ohms, though most are about .Schms. If you read zero, a short between phases exists. Usually ifit is an open, it's infinite or well above 2K ohms. Cable and Plug Notes Often times, the connector on the cable to the motor will get coolant init. Try drying it out and retesting. If itis still bad, the inserts themselves will sometimes get bum marks in them, causing a slight short. in this case, the inserts should be replaced, Also look for areas where the cable moves through tracking. Wires will wear through over time

You might also like