Lampiran 4 WELD INSPECTION REPORT/ SENTENCE SHEET PRINT FULL NAME ‘SPECIMEN NUMBER Face Defects EXTERNAL DEFECTS: Defecis Noted | EXTERNAL DEFECTS Defects Noted Defect Type ‘Accumulative | Maximum ‘Section! | Accept Total Allowance Table N’ | Reject 1 2 3 4 5 Reinforcement(Helght) ‘3mm 15 Reinforcement (Appearance) ‘Smooth toe blend | 18 Theompee Filing! Incomplete Na porated A Slag Inclusions: mm a Undercut 1mm i Surface Porosity, immo 2 Cracks Not permitted 1 Lack of fusion Not permitted 5 Arc strikes ‘Test with MPI 12 ‘Mechanical damage - Misalignment O2t=2mm 2 Root defects. Misalignment (0.21 =2 mm 3 Penetration (Height) 2mm 16 Incomplete Root Penetration Not permitted Lack of Root Fusion: Not permitted 5 Root Concavity mm max 19 Root Undercut = Cracks : 5 Mechanical damage Not permitted 4 Porosity - : Burn-through Not permitted 16 Misalignment (0.2t= 2mm 8 ‘This“pipe/ plate has been examined to the requirements of code/ specification TWH 09-09-06 And is *accepted/ rejected accordingly. SIgMALUFE. sone Date. *Delete which is not applicable. Use the other side for any comments, ‘Comments + Request Penetrant NDT testing to confirm crack and true length, ++ Large amount of spatter on weld face. Recommend cleaning, then re-inspection. +++ recommend arc strikes are ground flush prior to MPI testing for crack detection. ‘Seek advice on repair upon test results. ‘This completes the practical Butt Plate Joint Inspection Assessment 164 1 a i a 1 i 1 x ¥ a x a (GOVE CTEM) TVANTN NY nad v ‘uyue | veid yeqay uep Guelveg feduuibuayy ueynpnpay ™ tebunqueg siuop jeduury sasaig Lueyeundip Buek poy ‘uebueyepue | Zep | Jeans exnW Zuenduey (vesag jruny)) eweN TWNSIA NV¥SMINaWad NVI NYYORYT 165 1¥OdTY FLV Id NOILIIASNI TYNSIA dIMSO l Looe TEA Zuep z yeuns exnWW 166 Lampiran 3 DYE PENETRANT TEST REPORT COMPANY TOENG: ‘COMPANY LOGO TEST COUPON PLATE NO: 5 DATE PENETRANTTESTINGREPORT Boze os m3 eae Traitor No Tseatan Waters rexreat See face eat Teainert Tecess Tapraste hea apecton Sided ASUE V Sesion Maced RecepianceSinodad AGVEVAncoo, ABS Taroorent Manufacturing Process: MILD STEEL WELDED PLATE. wm | Penetration 5 | wateraasn PostEmulfy Sovent Remove 3 | FerevantTy5= & | Veoe Fourscent | oece pesca Eels peace Tevebper toe Dy: Wet aqueous: Non-aqueous: 7 [Sutacacaarea Tesi Tae T 4 (So 2 [ReroverApoeaton raster ae Tan GQ [Batace Drying Method: Max Teroerature: c e032" Appieaton Sudace Dy bev Roa en Renova of Yealaiera Freitag AYR ConearentorWied] C | E Idenifeaton [C4 | DelectDeserpton, LocatonandRemans E & P c T 1 [Teanean Wanager sae alr Ta Date 167 Bret Gescrpion of technique used with any appicable Penetrant Tesnng Equpment 1 2 3 = : WELDFACE mas 168 Lampiran 4 NA Wagnetic Particle Inspection Report CUENT LOCATION INSPECTION DATE Talisman Energy (UK) Montrose 19/03/2008 Limited ‘CAN JOB NO. REPORT NO. 6B4433 MON 4428 CLIENT ORDER NO. SHEET OF 1 COMPONENT/DESCRIPTIONDRAWINGNO. 11090 — Second Stage Separator Train2 MATERIAL Carbon Steel FROCEDURENVORK INSTRUCTION TECHNIQUE Wpo01g ‘SURFACE CONDITION Bare & Clean “ACCEPTANCE STANDARD B313 before remedial welding. No surface breaking defects were identified. EQUIPMENT FOWERICURRENT WATERIAL THICKNESS, CAN SB E52 Y6 Yok 110v NA WETHOD MEDIUM BACKGROUND Continuous Flow Neoastra Water Based NA Fluorescent RESULTS Wet Fluorescent MPI was carried out between the § and 7 o'clock position on the internal vessel shell This report reales excusnely to the work ordered andlor the Rema) mspected. Ishak not De reproduced except in full without the approval ofthe inspection body and the cient CAN INSPECTOR TSSUING AUTHORITY SIGN SIGN NAME. Bruce McKenzie NAME QUALS PCNLevel 2 DATE CLIENT SIGN NAME DATE 169 ULTRASONIC INSPECTION REPORT Lampiran 5 4 ‘SPECIMEN DESCRIPTION: ‘SPECIMEN NUMBER: PURPOSE OF INSPECTION: ‘AREA OF INSPECTION: EQUIPMENT USED FLAWDETECTOR PROBES Wake Serial No. Model: Frequency Seria No Angie REPORT: NAME: SIGNATURE: 170

You might also like