You are on page 1of 1

C/S OF BEAM(B1) C/S OF TIE BEAM(TB1)

NOTES:
1. All Dimensions are in mm & Levels are in meters unless specified.
2. Grade of Concrete shall be M30
C/S OF COLUMN 3. Clear cover to main reinforcement shall be as follows:
a) Walls = 50 mm, b) Slab = 50 mm, C) Footing = 50 mm
d) Beams = 50 mm e) Column = 50mm.

STAIR CASE RC DETAILS 5. P.C.C leveling Course (1:4:8) bellow bottom slab
(SLAB 150THK.) 6. Required Pipe sleves shall be provided during construction
7. Reinforcement steel shall be Fe 500
8. 150kN/sq.m SBC is considered at foundation level
9. Location and size of inlet, outlet pipes and vent pipes shown are tentative.
the same shall be as per the piping layout drawing
REFER SEPARATE DRAWING FOR DETAILS OF PIPE LOCATIONS

LOCATION OF STAIR CASE,SUCTION PIT,VENT PIMP ,DOOR&


WINDOW SHALL BE BE ADJUSTED AS PER SITE CONDITION.

ROOF SLAB RC DETAILS

SUCTION PIT DETAILS