C/S of Beam (B1) C/S of Tie Beam (Tb1) : Stair Case RC Details (SLAB 150THK.)
C/S of Beam (B1) C/S of Tie Beam (Tb1) : Stair Case RC Details (SLAB 150THK.)
NOTES:
1. All Dimensions are in mm & Levels are in meters unless specified.
2. Grade of Concrete shall be M30
C/S OF COLUMN 3. Clear cover to main reinforcement shall be as follows:
a) Walls = 50 mm, b) Slab = 50 mm, C) Footing = 50 mm
d) Beams = 50 mm e) Column = 50mm.
STAIR CASE RC DETAILS 5. P.C.C leveling Course (1:4:8) bellow bottom slab
(SLAB 150THK.) 6. Required Pipe sleves shall be provided during construction
7. Reinforcement steel shall be Fe 500
8. 150kN/sq.m SBC is considered at foundation level
9. Location and size of inlet, outlet pipes and vent pipes shown are tentative.
the same shall be as per the piping layout drawing
REFER SEPARATE DRAWING FOR DETAILS OF PIPE LOCATIONS