A d a p t e r
XLR connector RCA phono socket Jack with locking BNC socket
latch
Circular Adapters
NA3FP NA4FX-F
Ø 26.0 [1.024“]
110.5 [4.350“]
NA3FJ NA2FBNC
4 setting standards
A d a p t e r
Circular Adapters
• Neutrik speakON NL4FC with 1/4'' mono jack (Wiring: +1 to TIP and -1 to SLEEVE)
• Versatile, pre-wired and ready to use adapters to reliably interlock various connector systems
• Based on the XX Series
NA4LJ NA3FM
Ø 6.35 [1/4“]
78.0 [3.07“]
44 [1.73“]
30.2 [1.19"]
78 [3.07"]
www.neutrik.com 5
A d a p t e r
D Shape Adapters
• Problem solvers for various intermating problems for professional and semi-professional applications
• Rugged aluminium extrusion housings for best reliability
• Colour coding on all RCA types
NA2BBNC-D9B NA4MP-J
6 setting standards
A d a p t e r
D Shape Adapters
NAC3MM-1 NL8MM
www.neutrik.com 7
O r d e r i n g I n f o r m a t i o n
Circular Adapters
D Shape Adapters
NA2M-D0B-TX 3 pole XLR male RCA / phono socket colour coded black 4)
NA2M-D2B-TX 3 pole XLR male RCA / phono socket colour coded red 4)
NA2M-J-TX 3 pole XLR male 1/4" jack ground lifted 4)
1): Wired according to IEC 268-12: pin 2 = signal, pin 1 and 3: connected to ground
2): TRS-Tip, Ring, Sleeve contact (stereo); TS-Tip, Sleeve contact (mono)
3): Detailed wiring info on www.neutrik.com
4): Unbalanced / balanced line conversion, 1:1 transformer 200 Ω : 200 Ω
5): speakON is NOT to be used as an AC mains or power supply connector!
8 setting standards
A d a p t e r
A E S / E B U D i g i t a l I m p e d a n c e Tr a n s f o r m e r A d a p t e r s
Te c h n i c a l D a t a
Ordering Information
www.neutrik.com 9
A d a p t e r
DMX Adapters
NA3F5M NA3F5M
NA3F5M
3-pole 5-pole
Ordering Information
10 setting standards
A d a p t e r
Feedthrough
NA3FDM NA3MDF
NA3FDM NA3MDF
Ordering Information
NA3FDM 3 pole XLR female 3 pole XLR male
NA3MDF 3 pole XLR male 3 pole XLR female
www.neutrik.com 11
A d a p t e r
Rugged aluminium Latch lock system Rugged diecast shell IP65 Protected in mated
extrusion housing condition
etherCON ®
F e e d t h ro u g h & C AT 6 A A d a p t e r
NE8FF NE8FFX6-W
• Accommodates NE8MC* or any standard RJ45 plug • Ruggedized coupler with CAT6 A component compliance
• NE8FF coupler (adapter) for cable to cable mating – use according to ISO/IEC 11801 and TIA/EIA 568-C.2
with NE8MC carriers or any standard RJ45 plugs • IP65 protected when mated with NE8MX6*
• The adapter offers the approved latch lock system • Accommodates standard RJ45 plug
• Revolutionary small form factor
• The adapter offers the million fold proven robust latch
lock system
• The adapters are problem solvers for various intermating
problems for professional and semi-professional applications
NE8FF NE8FFX6-W
Ordering Information
NE8FF etherCON feedthrough coupler for cable to cable mating, black plating
NE8FFX6-W etherCON CAT6A feedthrough coupler for cable extensions, rubber sealing protection, IP65
12 setting standards
M o d u l e s & A u d i o T r a n s f o r m e r
M o d u l e s & A u d i o Tr a n s f o r m e r s
Audio Transformer
• Professional audio transformers for multiple applications, as e.g.
microphone or line inputs
• Very low distortion, excellent frequency response
• Cost effective cable version for free wiring
• Fully permalloy-shielded studio versions NTE10-3 NTL1
A u d i o Tr a n s f o r m e r s e l e c t i o n G u i d e
NTE1 1 : 1 200 : 200 200 / 2k, (600 / 10k) -3 General purpose, splitting, XLR inline
NTE4 1 : 4 200 : 3.2k 200 / 10 K -7 Mic input step-up
NTE10/3 1:3 200 : 1.8k 200 / 10 K -7 General purpose mic input step-up
1 : 10 200 : 20k 200 / 50 K -6
NTL1 1 : 1 10k : 10k 600 / 10k +19 Line input
NTM1 1 : 1 200 : 200 200 / 2k +7 Mic input, splitting
NTM4 1 : 4 200 : 3.2k 200 / 10k +9 Mic input step-up
* : measured with typical source / load impedances
Wiring: NTE*: free wires, NTL / NTM*... PCB mount, shielded; Find detailed specifications on www.neutrik.com
www.neutrik.com 13
O r d e r i n g I n f o r m a t i o n
NM3FXI KM NTE1
XLR female M 17x1 inside 1:1
M17x1 outside
NM2P VM NTE10/3
mono 1/4" plug M 17x1 outside 1:3:10
M17x1 inside
NM3J CM
stereo 1/4" jack cable outlet
M17x1 inside M 17x1 inside
NMPMM NA-Housing1)
RCA male black plated
M17x1 inside screws included
1) ... Combinations possible with all D Shape connectors like e.g. NC3FD-L-1, NF2D,
NMPMF
NBB75DSI, etc.
RCA female
M17x1 inside
Example:
NM3FD-B
black plated NM3MXI
NTE1 (inside)
D-Shape
KM KMX
NM3MD-B SM2/2
black plated NM3FXI
D-Shape
14 setting standards
G o o s e n e c k s
Goosenecks
www.neutrik.com 15
O r d e r i n g I n f o r m a t i o n
Part No. D e s c r i p t i o n
Gosseneck:
Gosseneck sets:
GNS18 Gooseneck set GN18, NC3FX-Spec., cable outlet, NAM5 adapter, M17 x 1 bolt thread
GNS36 Gooseneck set GN16, NC3FX-Spec., cable outlet, NAM5 adapter, M17 x 1 bolt thread
GNS50 Gooseneck set GN50, NC3FX-Spec., cable outlet, NAM5 adapter, M17 x 1 bolt thread
Accessories:
16 setting standards
Patch Panels
i n n o v a t i v e s o l u t i o n s
18 setting standards
s u p e r i o r q u a l i t y
Audio Normalling
RN
Other versions of normalling are Half Normalled Top Row,
Full Normalled, Parallel and Isolated.
www.neutrik.com 19
N P P A S e r i e s
Robust front design Easy assembly Jack-pair IDC terminals Push terminals ELCO connectors
NPPA-TT-PT
• Innovative and compact patching system (just 1U high) for 19“ rack mounting
• Robustly housed in a black coated steel shell
• Features 2 x 48 long life gold plated TT size (bantam) Neutrik NJ3TTA double contact point TRS jacks
• Available in all common normalling configurations (default Half Normalled Bottom)
• Qualified for analog and digital signals according to AES3, 48 kHz sampling frequency
• Remove the front panel for quick changes of the NJ3TTA-** modules for reconfiguration or repair even when "on air"
• Includes two built in cable bars and two wide channel ID strips
• PatchLink Software for printing onto labeling strips is on Neutrik website (available for PC only)
Dimensional Drawing
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 25 26 27 28 48
Half Normalled Bottom Half Normalled Top Full Normalled Parallel Isolated Grounding
S S S S S
R R R R R Common Signal Ground
T T T T T
Upper Row
Soldering Pads
Chassis Ground to connect
S S S S S
R R R R R Individual Grounds to Common Ground
T T T T T
Common Signal Ground
Bottom Row
S S S S
Module Arrangement
T
TN TN
T
Top View
R R
RN RN
TN TN
T T
R R
RN RN
Key
NPPA-TT-PT
20 setting standards
N P P A S e r i e s
Design Criteria
All NPPA patch panels are fitted with high quality, long life
NJ3TTA gold plated double contact jacks (2x48), featuring best
contact integrity. The unit, robustly housed in a black coated
steel shell, is finished off with a built in cable bar and two large
channel identification strips for perfect management of the
system. The NPPA patch panels are an innovative and compact
patching system (just 1U high) for 19" rack mounting.
Configuration
The standard version of the NPPA Panel is delivered bottom row For individual normalling single pre-configured jack-pairs
half normalled for each jack pair by default. Further patch ver- are offered.
sions are available with fully loaded jack-pairs as: NPPA-TT-IDC is equipped with jumper blocks for individual
switching configurations of each jack channel.
• Full Normalled
• Half Normalled Note: Take care when handling digital signals. Do not use
• Isolated parallel configuration and avoid other parallel paths when
• Parallel using half normalled configurations. Parallel paths may lead
to mismatching.
Half Normalled Bottom Half Normalled Top Full Normalled Parallel Isolated
S S S S S
R R R R R
T T T T T
S S S S S
R R R R R
T T T T T
S S S S
TN TN
T T
R R
Grounding
RN RN
TN TN
T T
R R
RN RN
• Individual: Each channel is individually grounded by its corresponding cable shield (default configuration).
• Group: Selected channel grounds are connected via the ground bus on the PCB using solder bridges and track cuts to form a
group that is connected to one common cable shield.
• Central: All channel grounds (individual top and bottom row) are connected via the ground bus on the PCB using solder
bridges and wired with only one cable shield.
• Chassis-Common: The same as central grounding but with the addition of the common ground bus (top and / or bottom
rows) connected to the patch panel chassis by means of jumpers
W i r i n g Te r m i n a t i o n s
• Spring loaded push terminals The spring loaded terminal blocks enable fast and easy wir-
• 56 pin Elco/Edac male connectors ing. No soldering and screwing necessary. Simply insert the
• 90 pin Elco/Edac connectors stripped wire after pressing down the white key. Terminals
• 50 pin D-SUB connectors accommodate stranded wires up to AWG 20 (0.5 mm2) and
• 25 pin D-SUB connectors solid wires up to AWG 18 (0.75 mm2). Push terminals are
• IDC-Krone terminals gas tight connections.
• Solder lugs
For Pin assignment of ELCO / EDAC and D-SUB connectors please see drawings on www.neutrik.com
www.neutrik.com 21
N P P - T B S e r i e s
• Features 2 x 24 Neutrik® NJ6TB-V long frame 1/4” TRS jacks according to BPO316/MIL-P-642/2
• Very robust and compact galvanized metal housing
• Compact, cost effective system qualified for both analog and digital signals acc. AES3, 48 kHz sampling frequency
• High quality long life gold plated Neutrik jacks
• Easily programmable for any of 6 configurations with 4 grounding choices
• Rear terminations include solderless terminal blocks or solder lugs
(solder for non-programmable half-normalled versions only).
• Center marking strip is removable; See Neutrik website to download PatchLink labeling software for PCs
• Color coded tabs, dust cover and rear extension strain relief bars are optional accessories
Dimensional Drawing
NPP- S (Accessories)
NPP- S
22 setting standards
N P P - T B S e r i e s
Design Criteria
The NPP-TB patch panels are equipped with gold plated, attractive additional lettering area for each channel pair
high quality long life NJ6TB-V Jacks for BPO/MIL style with a marking strip and individual snap-on colour coding
plugs. The panels are easily programmable for six switching plates.
configurations and offer a flexible grounding system.
The NPP-TB patch panels are very robust and compactly
designed for 19" rack mount (19" x 1U) with galvanized
metal housing and a built-in cable bar on the rear for
securing wires. There is a rear extension bar (NPP-S)
available as an option. On the front side there is an
Configuration
Due to the jumper blocks capability provided, the switching The TB Panel is delivered in a full normalled configuration
configurations available per jack channel are: for each jack channel. A non-configurable half normalled
("-HN") bottom row version with solder lugs is also avail-
• Half Normalled Bottom Row able.
• Full Normalled NOTE: Take care when handling digital signals. Do not use
• Parallel Parallel configuration and avoid other parallel paths with
• Isolated Half / Double Normalled configurations. Parallel paths may
lead to mismatching.
Half Normalled Bottom Half Normalled Top Full Normalled Parallel Isolated Double Normalled
Grounding
The flexible grounding system allows four possibilities to fit your needs:
• Individual: Each channel ground is separately connected with the corresponding cable shield (default configuration).
• Group: Some channel grounds are PCB connected by making soldering joints on the PCB and by cutting tracks
respectively to form a group that is connected to one common cable shield.
• Central: All channel grounds are PCB connected by making soldering joints and wired with only one cable shield.
• Chassis-Common: Same as central grounding with additional connection of the common ground to the Patch
Panel chassis by means of a jumper.
W i r i n g Te r m i n a t i o n s
The spring loaded terminal blocks are fast and easy to connect and disconnect the wires.
No soldering and screwing necessary. Simply insert the stripped wire after pressing down the white key.
Accommodates stranded wires up to AWG 20 (0.5 mm2) and solid wires up to AWG 18 (0.75 mm2).
www.neutrik.com 23
N Y S S e r i e s
NYS-SPP-L1
Dimensional Drawing
24 setting standards
N Y S S e r i e s
Design Criteria
The NYS-SPP-L1 is a economical and remarkable sleek The PCBs are held securely in place by being clamped
designed 1/4“ modular patch panel for 19“ rack mount (19“ between the front and the rear panel, this grants an easy
x 1U) with a reinforced metal housing. Each of it‘s 48 PCB reconfiguration of the patch panel without the danger of
wired balanced channels (24 front pairs and correspond- loosing any small parts (e.g. nuts). The grey jack serves as an
ing 24 rear pairs) can either be grounded separately or in easy and distinguishable normalling identification.
groups of inividually chooseable channel numbers (detailed
information see below).
Configuration
Standard configuration, when delivered, is Half Normalled grey jack will always isolate the top against the bottom row.
bottom row. The configuration can easily be changed by Alternative solution for send / return applications by use of
just flipping the individual PCB. Inserting a plug into the NYS-SPCR1 module (see accessories below).
front rear front rear front rear front rear With Switching Contacts
A front T T R
A A A A A A A Plug A Mono - Send
Rear
Send - Return
B front (Stereo Jack)
B B B Plug B B B B B Mono - Return
(Red Jack) T
Front jack A for "listen in" Grey B jack for signal insertion Allows: 1 output to feed 2 inputs Upper (A) and lower (B) channel
Solution for insert jack of mixing consoles
separated NYS-SPCR1 Split print by-passes the use of a specially
wired Y-cable.
Grounding
The flexible grounding system, applicable for each channel separately by simply attaching the loose supplied grounding clips
to the grounding pad of the corresponding channel, offers the following alternatives:
• Individual (without grounding clip): Each channel ground (sleeve contact) is connected to the dedicated ground
contact of the incoming 1/4” plug only. This is the standard configuration for delivery.
• Chassis common : The relevant channel grounds (sleeve contacts; top and bottom row) is connected to the
ground flat tab via grounding clip and chassis.
• Chassis top : The dedicated top channel ground (sleeve contact) is connected to the ground flat tab via grounding
clip and chassis.
• Chassis bottom : The dedicated bottom channel ground (sleeve contact) is connected to the ground flat tab via
grounding clip and chassis.
the wire.
www.neutrik.com 25
B a n t a m P a t c h P a n e l s
• Robust designed patchbay to accept standard 4.4 mm Bantam jack connectors (acc. MIL-D-642/13)
• Fitted with 96 Rean die-cast jack sockets
• Constructed from rigid aluminium extrusion which includes 2 integral slots for designation strips
• 96 channels grouped in two row 12 x 8 stereo jacks
• XPM96 features traditional 2 row, 4 x 24 stereo jacks
• Available in 4 colours: black, silver, red or blue
• Suitable for audio, broadcast, data and industrial applications XPM96
Dimensional Drawing
26 setting standards
B a n t a m P a t c h P a n e l s
• 5-point Bantam jack socket (Tip, Ring, Sleeve, Tip Normal, Ring Normal)
• Rigid nickel plated die-cast frame, featuring considerable frame strength eliminating physical distortion when plug is inserted
• Nickel-silver spring contacts, palladium plated switch contacts
• Tinned tags for easy soldering
www.neutrik.com 27
L o n g f r a m e B - G a u g e P a t c h P a n e l s
LF 48 B-Gauge Patchbays
Dimensional Drawing
28 setting standards
L o n g f r a m e B - G a u g e P a t c h P a n e l s
Solder lugs
Circuit Detail
www.neutrik.com 29
T e c h n i c a l D a t a
Electrical
Mechanical
Material
Operating Accessories
Labeling software
30 setting standards
O r d e r i n g I n f o r m a t i o n
P a r t N u m b e r Description
Pre-configured Jack-Pairs
NJ3TTA-4-HNB blocks of 2 channels half normalled bottom row cover ident color: clear
NJ3TTA-4-HNT blocks of 2 channels half normalled top row cover ident color: yellow
NJ3TTA-4-FN blocks of 2 channels full normalled cover ident color: green
NJ3TTA-4-P blocks of 2 channels parallel cover ident color: red
NJ3TTA-4-I blocks of 2 channels isolated cover ident color: orange
Accessories
NPPA-S Strain Relief bar
NKTT* Patch cords with NP3TT-1 plugs. Available in black, blue, green, red and yellow. Lenght: 30, 40, 60, 90, 120 cm
NPP-TB 2 x 24 TB (BP0316/MIL-P-642/2) jacks programmable for all commonly used configurations push terminals
NPP-TB-HN 2 x 24 TB (BP0316/MIL-P-642/2) jacks half Normalled Bottom Row solder tags
Accessories
NPP-LB-** Channel identification and status plates, pack of 100 per color, 9 different colors
NPP-C Metal dust cover
NPP-S A second rear extention bar for fix the very large cables.
NKTB* Patch cord with NP3TB plugs. Available in black and red. Length: 30, 40, 60, 90 cm
**: 0 - Black, 1- Brown, 2 - Red, 3 - Orange, 4 - Yellow, 5 - Green, 6 - Blue, 7 - Violet, 8 - Grey, 9 - White; Must be ordered in multiples of 100.
NYS SPPL
NYS-SPP-L1 1/4" Patch Panel, 2 x 24 channels, configuration half normalled, isolated, split
NYS-SPCR1 Send / Return module (Split Print)
www.neutrik.com 31
O r d e r i n g I n f o r m a t i o n
P a r t N u m b e r Description
32 setting standards
Definitions, Abbreviations & Useful Information
Ag Silver N Newton
Al Aluminium Ω Ohm
Au Gold µ Micro
Co Cobalt OD Outside Diameter
Cr Chromium m Meter(s)
Cu Copper k Kilo
Ni Nickel
P Phosphorus ENGLISH TO METRIC CONVERSIONS
Pb Lead
Pd Palladium 1/8 inch 3.175 millimeters (mm)
Sn Tin 1/4 inch 6.35 millimeters (mm)
Zn Zinc 1 inch 25.4 millimeters (mm)
SS Stainless Steel 2.54 cm 1 inch
1 foot 30.48 centimeters (cm)
ALLOYS, PLASTICS, POLYMERS 0.305 meter (m)
6 foot 1.828 meters (m)
Brass (Alloy) CuZn39Pb3 50 foot 15.24 meters (m)
Bronze (Alloy) CuSn6 100 foot 30.48 meters (m)
Ck 67 Carbon Steel 1000 foot 304.8 meters (m)
EPDM Ethylene Propylene
GR Glass Reinforced METRIC TO ENGLISH CONVERSIONS
PA Polyamide
PBTP Polybutylene Terephthalate 1 centimeter 0.3937 inches
POM Polyacetal 1 meter 39.37 inches
PTFE PolyTetraFluoroEthylene (TEFLON) 3.281 meter 10 feet
PUR Polyurethane 10 meters 32.808 feet
50 meters 164.041 feet
100 meters 328.084 feet
OTHER ABBREVIATIONS
NEUTRIK, crystalCON®, etherCON®, maxCON®, miniCON®, nanoCON®, neutriCON®, opticalCON®, powerCON®, Profi®,
rearTWIST®, silentPLUG®, speakON®, TOP®, DiWA®, XIRIUM®, are registered trademarks of Neutrik AG.
www.neutrik.com 33
P a r t N u m b e r G u i d e
N e u t r i k P a r t N u m b e r G u i d e
®
N C 3 FA H 1 - B - 0 - D
Packaging: D Cable connector: bulk packed
Assembly: D Chassis connector: disassembled push latch
Retention: w/o Latch lock
-0 Retention spring
-DA Asymmetric PUSH
Shell: B Black shell, gold contacts
BAG Black shell, silver contacts
Grounding: 0 Separate ground contact connected to shell, male only
1 Pin 1 & panel & shell connected, no separate ground contact
2 Separate ground contact connected to shell & panel, separate Pin 1
E Additional ground contacts
w/o number No ground / shell contact (except 4 / 5 pole), female only
Termination: H Horizontal PCB mount
HL Laterial left PCB mount
HR Laterial right PCB mount
L Solder cups
V Verticale PCB mount
Y IDC for wires (no ground)
M3 Mounting holes with M 3 thread
M25 Mounting holes with M 2.5 thread
- Not applicable
Series: A, AA, B, D, DL, DLX, MPR, P, PX, RX, X, XX
Gender: F Female
M Male
Number of Contacts: 2, 3, 4, 5, 6, 7, 8, 12
Connector Type: A Adapter
AC powerCON
B BNC
C XLR
D dummyPLUG
E etherCON - RJ45
F RCA / CINCH
J (MJ, RJ, SJ) Jack
K Cable Assembly
L speakON - Loudspeaker
M Module
O opticalCON - Fiber Optic Connector
P Plug
PP Patch Panel
R Circular Connector
T Transformer
TOP True Outdoor Protection
34 setting standards
®
LIECHTENSTEIN (HEADQUARTERS)
Neutrik AG, Im alten Riet 143, 9494 Schaan
T +423 237 24 24, F +423 232 53 93, neutrik@neutrik.com
GREAT BRITAIN
Neutrik (UK) Ltd., Westridge Business Park, Cothey Way
Accessories & Patch Panel Product Guide 2019/07 V20 – NPGE-APP – Data subject to change without prior notice. © 2019 NEUTRIK®. ALL RIGHTS RESERVED.
Ryde, Isle of Wight PO33 1 QT
T +44 1983 811 441, sales@neutrik.co.uk
FRANCE
Neutrik France SARL, 52 rue d’aguesseau, 1er etage, 92100 Boulogne-Billancourt
T +33 1 41 31 67 50, info@neutrik.fr
USA
Neutrik USA Inc., 4115 Taggart Creek Road, Charlotte, North Carolina, 28208
T +1 704 972 30 50, info@neutrikusa.com
JAPAN
Neutrik Limited, Yusen-Higashinihonbashi-Ekimae Bldg., 3-7-19
Higashinihonbashi, Chuo-ku, Tokyo 103
T +81 3 3663 47 33, mail@neutrik.co.jp
HONG KONG
Neutrik Hong Kong LTD., Suite 18, 7th Floor Shatin Galleria
Fotan, Shatin
T +852 2687 6055, sales@neutrik.com.hk
CHINA
Ningbo Neutrik Trading Co., Ltd., Shiqi Street, Yinxian Road West
Fengjia Villiage, Hai Shu District, Ningbo, Zhejiang, 315153
T +86 574 88250833, sales@neutrik.com.cn
INDIA
Neutrik India Pvt. Ltd., Level 3, Neo Vikram, New Link Road,
Above Audi Show Room, Andheri West, Mumbai, 400053
T +91 982 05 43 424, anklesaria@neutrik.com
ASSOCIATED COMPANIES
Contrik AG
Steinackerstrasse 35, 8902 Urdorf, Switzerland
T +41 44 736 50 10, contrik@contrik.ch
H. Adam GmbH
Felix-Wankel-Straße 1, 85221 Dachau, Germany
T +49 08131 28 08-0, anfrage@adam-gmbh.de
www.neutrik.com
2019/07-V20