You are on page 1of 12

ISO-CONNECT

The connector for additional connections on thermally insulated timber facades.

Innovative timber connection systems for highest requirements.


ISO-CONNECT
The ISO-CONNECT system offers, due to the combination of tension and compression screws perpendicular to the
facade and inclined screws to transfer shear loads, a connection point on thermally insulated facades of timber
constructions. Areas of application are for example purlins, rafters, french balconies etc. . The compatibility with the
HVP connector system extends the applications of the ISO-CONNECT. So also a direct connection of beams to the fa-
cade is possible. As a further option, the connection concept offers the possibility to mount purlin with threaded rods
directly to the ISO-CONNECT and the facade.

The ISO-CONNECT can be mounted on solid timber, glulam and cross laminated timber.

83100.0___ 83200.0___ 83300.0___

Item no. Description Dimension B x H x D [mm] Threaded hole

M8 M12 M20

83100.0___ Connection to HVP 88210.3000 90 x 100 x 15 - 4 -

83200.0___ Connection to french balcony Ø 80 x 15 4 1 -

83300.0___ Universal connection threaded rod M20 120 x 155 x 15 4 - 1

The ISO-CONNECT is only available as a set with the appropriate screws. The insulation thickness must be specified for this reason.
Example for insulation 160 mm: 83100.0160

Product information
The ISO-CONNECT connection plates may only be used in combination with the including
screws with countersunk head.

The deformation of the rubber mat (3 mm thick) included in the scope of delivery indicates
the contact pressure of the connection plate. In addition, this ensures a reliable effect of
the seal, as three-flank adhesion of the adhesive and sealant is avoided.

Scope of delivery: Connection plate, rubber mat and suitable screws for your insulation.
Universal connection is supplied with matching steel pressure plate.

Assembling
1. Positioning of the connector and optionally the rubber mat
2. Fix the connector plate first with the screws perpendicular (horizontal) to the
facade until contact to the facade surface is reached. If using the rubber mat
screw in until low deformations are reached.
3. Screw in inclined screws.
4. Installation of the balcony railing, the HVP connector or the counter plate of
the universal connector.
5. The gap between ISO-CONNECT and the facade should be filled with silicone
(acetic-free).

2 ISO-CONNECT
Calculation
The acting forces are devided into tension and compression stresses, are transfered with screws through the insula-
tion into the timber construction. The load distribution and the stress on the screws are shown below for each con-
nector version.

The load carrying capacity depends first on the withdrawal parameter and the tensile strength of the Fischer Pow-
er-Fast screws. And second on the compression strength (=withdrawal parameter of the effective point side penet-
ration length of the
Berechnungskonzept threaded part in timber) and theBerechnungskonzept
Berechnungskonzept buckling load capacity in the area of the free screw length in the
Berechnungskonzept
thermal
Berechnungskonzept
Berechnungskonzept
insulation.
Die einwirkende
einwirkende Kraft
Kraft
Diewird in Zug-
Zug- und
einwirkende und Kraft Die einwirkende Kraft wird in Zug- und Druckräfte aufgeteilt und von den Schrauben durch
Druckräfte
wird aufgeteilt
in Zug- und und von
von den
Druckräfte den Schrauben
aufgeteilt und durch
von dieSchrauben
Die Die
Die einwirkende
wird in
einwirkende Kraft wird
wird in
Druckräfte
Kraft in Zug- und
und Druckräfte
aufgeteilt
Zug- und
Druckräfte aufgeteilt
Schraubenund von den
durchdendie Schrauben
Schrauben durch
durch die
durch die
Dämmung geleitet und ins
Dämmung Holz weitergegeben.
geleitet und ins Holz Dämmung aufgeteilt
weitergegeben. geleitet und und insvon
Holzdenweitergegeben. die
Dämmung geleitet Dämmung
und ins Holz geleitet und
weitergegeben. ins Holz weitergegeben.
Provide evidence: Load carrying-capacity of the screws > stress of the screws
Dämmung geleitet und ins Holz weitergegeben.
Die Tragfähigkeit der Zugschrauben istHolz
abhängig vom Gewindewiderstand im Holz und der
Die Tragfähigkeit
Die Tragfähigkeit der
Berechnungskonzept Berechnungskonzept
derDie
Zugschrauben
Die Tragfähigkeit
Tragfähigkeit
Zugschrauben
Die Tragfähigkeit
istder
ist abhängig
der
abhängig
der
vom Gewindewiderstand
Zugschrauben
Zugschrauben
vom
Zugschrauben
Gewindewiderstand
ist
ist abhängig
ist abhängig
abhängig
vom
vom im Holz
Holz und der
Gewindewiderstand
vom Gewindewiderstand
Zugtragfähigkeit.
im und
Gewindewiderstand
Die
der
Tragfähigkeit
im
im
im
der
Holz
Holz
und
und der
und der
der
Druckschrauben istHolz
abhängig vom Gewindewidersta
Zugtragfähigkeit. Die
DieZugtragfähigkeit.
Tragfähigkeit der derDie
Druckschrauben
Tragfähigkeit ist abhängig
der abhängig vom Gewindewiderstand
Druckschrauben Gewindewiderstand
ist abhängig vom im HolzHolz
Gewindewiderstand
Zugtragfähigkeit. Zugtragfähigkeit.
Tragfähigkeit
Die einwirkende Kraft
Zugtragfähigkeit. Die
Die Tragfähigkeit
Druckschrauben
Tragfähigkeit der
wird in Zug- undist
der Druckschrauben
Druckräfte vom
Druckschrauben
und dem
ist
ist abhängig
aufgeteilt
Knickwiderstandund von
abhängig vom
den
vom
bzw. der
Gewindewiderstand
im
Schrauben
Gewindewiderstand
freien durch dieim
im
im Holz
Schraubenlänge Holz
im Bereich der Dämmung.
Die einwirkende
und dem Kraft
dem Knickwiderstand
Knickwiderstand
undwird in
bzw.
dem Zug- und
der freien Druckräfte aufgeteilt
freien Schraubenlänge
Knickwiderstand Schraubenlänge und von
im Bereich
Bereich den Schrauben
der Dämmung.
Dämmung. durch die
und und
und dem
Dämmung bzw.
dem der
geleitet und ins bzw.
Knickwiderstand
Knickwiderstand Holz der
bzw.
bzw. der freien
der freien
im Schraubenlänge
Schraubenlänge
weitergegeben.
freien der
Schraubenlänge
im
im Bereich der
im Bereich
Bereich der
Dämmung.
der Dämmung.
Dämmung.
Load carrying-capacity of the tension screws
Dämmung geleitet und ins Holz weitergegeben.
Tragfähigkeit der
der Zugschrauben
Zugschrauben
Tragfähigkeit der Zugschrauben Tragfähigkeit der Zugschrauben
Tragfähigkeit Tragfähigkeit
Die Tragfähigkeitder Zugschrauben
der Zugschrauben ist abhängig vom Gewindewiderstand im Holz und der
Die Tragfähigkeit derTragfähigkeit
Zugschrauben der istZugschrauben
abhängig vom Gewindewiderstand im Holz und der
Withdrawal capacity for screws in
Zugtragfähigkeit. solid timber
DiefürTragfähigkeit Gewindewiderstand für Schrauben
Values in
for𝑑𝑑d= =8Vollholz
mm : oder BSH im HolzWerte für 𝑑𝑑 = 8 𝑚𝑚𝑚𝑚 :
8𝑚𝑚𝑚𝑚
Gewindewiderstand
Zugtragfähigkeit. Diefür Schrauben
Gewindewiderstand
Tragfähigkeit Vollholz
inder
Gewindewiderstand für oder BSH
Schrauben
Schrauben
Druckschrauben inder
BSH in Druckschrauben
Vollholz
Vollholz oder
Werte BSH
für
oderfür
BSH𝑑𝑑 = 8ist abhängig
Werte
:: Werte
=Gewindewiderstand
𝑚𝑚𝑚𝑚 vom
für
für
Gewindewiderstand
𝑑𝑑 =im Holz:::
8 𝑚𝑚𝑚𝑚
Gewindewiderstand
accortingsich
ermittelt to ETA
nach
für
und
ETA
Schrauben
ETA-11/0027:
dem
11/0027:
ermittelt
in
Gewindewiderstand Vollholz
Knickwiderstand
sich nach ETA
oder
für11/0027:
Schrauben
bzw. in ist
der
abhängig
Vollholz
freien
Werte
oder
ermitteltvom
BSH𝑑𝑑
sich
Schraubenlänge
𝛼𝛼: screw axis -
8
nach𝑚𝑚𝑚𝑚
grainETA
im 11/0027:
Werte
Bereich
direction
𝛼𝛼: füraxis
screw 𝑑𝑑 =-Dämmung.
der 8 𝑚𝑚𝑚𝑚
grain direction 𝛼𝛼: screw axis - grain direction
ermittelt
und sich nach ETAermittelt
dem Knickwiderstand bzw.sich
11/0027:
ermittelt der𝜌𝜌nach
sich nach ETA
freien 11/0027:
ETASchraubenlänge
0,8 11/0027: 𝜌𝜌 0,8 im 𝛼𝛼:
0,8 screw axis
Bereich der -Dämmung. 𝛼𝛼: screw
𝛼𝛼: screw axis
grain direction -- grain
axis 𝜌𝜌 grain0,8 direction
direction
𝜌𝜌 𝑘𝑘𝑎𝑎𝑎𝑎 = 1,0
𝑛𝑛 ∙ 𝑘𝑘𝑎𝑎𝑎𝑎 ∙ 𝑓𝑓𝑎𝑎𝑎𝑎,𝑘𝑘𝑘𝑘𝑘𝑘∙𝑎𝑎𝑎𝑎 = 1,0
𝑘𝑘 𝑘𝑘𝑎𝑎𝑎𝑎,𝑘𝑘
𝜌𝜌𝑎𝑎𝑎𝑎
𝑘𝑘 0,8 𝜌𝜌𝑘𝑘𝑘𝑘𝑘𝑘 )0,8
0,8 𝐹𝐹
𝑘𝑘 𝑎𝑎𝑎𝑎 == 1,0 𝑑𝑑=
𝑎𝑎𝑎𝑎 ∙ 𝑙𝑙1,0
𝑒𝑒𝑒𝑒,𝑡𝑡 ∙ ( )
𝐹𝐹𝑎𝑎𝑎𝑎,𝑘𝑘 = = 𝑛𝑛𝑛𝑛𝑒𝑒𝑒𝑒 ∙∙ 𝑘𝑘
𝑘𝑘𝑎𝑎𝑎𝑎 ∙∙ 𝑓𝑓
𝑓𝑓𝑎𝑎𝑎𝑎,𝑘𝑘 ∙ 𝑑𝑑
𝑑𝑑 ∙∙ = 𝑎𝑎𝑎𝑎 = 1,0𝑒𝑒𝑒𝑒
𝑙𝑙𝑙𝑙𝑒𝑒𝑒𝑒,𝑡𝑡 ∙ ((∙∙ 𝑘𝑘
𝐹𝐹
𝐹𝐹 = 𝑛𝑛
𝑛𝑛 𝑘𝑘 𝑘𝑘 )∙∙ 𝑓𝑓 𝑎𝑎𝑎𝑎,𝑘𝑘 ∙∙ 𝑑𝑑
𝑓𝑓𝑓𝑓𝑎𝑎𝑎𝑎,𝑘𝑘 𝑑𝑑 ∙∙ 𝑙𝑙𝑙𝑙𝑒𝑒𝑒𝑒,𝑡𝑡
𝑒𝑒𝑒𝑒,𝑡𝑡 ∙∙ (((350𝜌𝜌𝑘𝑘𝑘𝑘 )0,8 𝑘𝑘𝑎𝑎𝑎𝑎
𝑎𝑎𝑎𝑎 = 1,0 350 222 𝑓𝑓𝑎𝑎𝑎𝑎,𝑘𝑘 = 10 𝑁𝑁𝑁𝑁𝑁𝑁𝑁2
𝐹𝐹 Tragfähigkeit
𝐹𝐹 𝑎𝑎𝑎𝑎,𝑘𝑘
∙𝑎𝑎𝑎𝑎,𝑘𝑘
𝑎𝑎𝑎𝑎,𝑘𝑘
𝑎𝑎𝑎𝑎,𝑘𝑘 = 𝑒𝑒𝑒𝑒,𝑡𝑡
𝑛𝑛 𝑒𝑒𝑒𝑒

𝑒𝑒𝑒𝑒
𝑒𝑒𝑒𝑒 ∙ der
𝑘𝑘
350
𝑎𝑎𝑎𝑎
𝑎𝑎𝑎𝑎 )∙Zugschrauben
𝑎𝑎𝑎𝑎,𝑘𝑘 ∙ 𝑑𝑑 ∙ 𝑙𝑙 𝑒𝑒𝑒𝑒,𝑡𝑡 ∙ 350 ) 𝑓𝑓 = 10 𝑁𝑁𝑁𝑁𝑁𝑁𝑁 2
𝑓𝑓
𝑓𝑓
𝑎𝑎𝑎𝑎 =
= 10
10 𝑁𝑁𝑁𝑁𝑁𝑁𝑁
𝑁𝑁𝑁𝑁𝑁𝑁𝑁
Tragfähigkeit der Zugschrauben
𝑎𝑎𝑎𝑎,𝑘𝑘 𝑒𝑒𝑒𝑒 𝑎𝑎𝑎𝑎 𝑎𝑎𝑎𝑎,𝑘𝑘 𝑎𝑎𝑎𝑎,𝑘𝑘 𝑒𝑒𝑒𝑒 350
𝑒𝑒𝑒𝑒 𝑎𝑎𝑎𝑎
𝑎𝑎𝑎𝑎 𝑎𝑎𝑎𝑎,𝑘𝑘
𝑎𝑎𝑎𝑎,𝑘𝑘 𝑒𝑒𝑒𝑒,𝑡𝑡
𝑒𝑒𝑒𝑒,𝑡𝑡
350 𝑓𝑓 𝑎𝑎𝑎𝑎,𝑘𝑘 = 10 𝑁𝑁𝑁𝑁𝑁𝑁𝑁
𝑎𝑎𝑎𝑎,𝑘𝑘
2
𝑓𝑓 𝑎𝑎𝑎𝑎,𝑘𝑘
𝑎𝑎𝑎𝑎,𝑘𝑘
𝑎𝑎𝑎𝑎,𝑘𝑘
𝑎𝑎𝑎𝑎,𝑘𝑘 = 10 𝑁𝑁𝑁𝑁𝑁𝑁𝑁 22
𝑙𝑙 : effective point side penetra
𝑙𝑙𝑙𝑙𝑒𝑒𝑒𝑒 effective point
𝑒𝑒𝑒𝑒:: effective point side
side 𝑙𝑙𝑒𝑒𝑒𝑒 penetration
:: effective
𝑎𝑎𝑎𝑎,𝑘𝑘
effectiveinpoint lengthside
point side penetration
penetration length
length 𝑒𝑒𝑒𝑒
Gewindewiderstand für Gewindewiderstand
Schrauben
Gewindewiderstand in für Schrauben
Brettsperrholz
für Schrauben ermittelt Vollholz
in Brettsperrholz
in Gewindewiderstand
oderthreaded
BSH
ermittelt für𝑙𝑙𝑙𝑙Werte
𝑒𝑒𝑒𝑒
𝑒𝑒𝑒𝑒
𝑒𝑒𝑒𝑒penetration
Schrauben
: effective
für 𝑑𝑑 =point length
8Brettsperrholz
𝑚𝑚𝑚𝑚side ermittelt
: penetration length of the threaded part
Gewindewiderstand für Gewindewiderstand
Schrauben in Vollholz
Gewindewiderstand für
für oder
Brettsperrholz Schrauben
Schrauben BSHermittelt in
in Brettsperrholzof
Brettsperrholz
Werte
of the the ermittelt
fürermittelt part
𝑑𝑑 = und
threaded 8 part
𝑚𝑚𝑚𝑚 of
: of 𝑒𝑒𝑒𝑒 the threaded
the threaded part part
sich nach Blaß Uibel 𝛼𝛼: (2009):
of the
screw threaded part 𝜌𝜌𝑘𝑘: characteristic density of the
sich nach
ermittelt
sich nach sichBlaßnach
Blaß und Uibel
und Uibel
ETAsich
ermittelt
sich11/0027:nach sich
(2009):
nach
(2009):
Blaßnach
Blaß und Uibel
und
ETA
Uibel11/0027: (2009):
(2009): 𝜌𝜌𝑘𝑘::screw characteristic density
axis - graindensity 𝜌𝜌
direction
𝜌𝜌 of
𝑘𝑘:: of theaxis
characteristic
characteristic
- grain
timber directionthe timber
density
density of
of the timber
sich nach Blaß und0,8 Uibel (2009): 𝜌𝜌𝑘𝑘 0,8 𝛼𝛼: 𝜌𝜌 𝑘𝑘 characteristic
0,9 𝜌𝜌
𝑘𝑘
𝑛𝑛
𝑘𝑘
𝑘𝑘 :
𝑘𝑘 =
=
the
1,0
𝑛𝑛 0,9 timber density of the timber
characteristic
0,9 𝑛𝑛𝑒𝑒𝑒𝑒 = 𝑛𝑛0,9
𝐹𝐹𝑎𝑎𝑎𝑎,𝑘𝑘 = 𝑛𝑛 ∙ 𝑘𝑘 𝑘𝑘 ∙ 𝑓𝑓0,8 𝜌𝜌 𝑎𝑎𝑎𝑎,𝑘𝑘 ∙0,9 𝑑𝑑 ∙ 𝑙𝑙 ∙( ) 𝑘𝑘 𝑛𝑛 =
𝑒𝑒𝑒𝑒 = 1,0𝑛𝑛 𝑘𝑘
𝑎𝑎𝑎𝑎 0,9
31 ∙ 𝑑𝑑 0,8 ∙𝑛𝑛
𝑛𝑛𝑎𝑎𝑎𝑎 0,9 𝑒𝑒𝑒𝑒 = 𝑛𝑛 0,9
𝑒𝑒𝑒𝑒 = 𝑛𝑛
𝑒𝑒𝑒𝑒
0,9 0,9
𝐹𝐹𝑎𝑎𝑎𝑎,𝑘𝑘 = 𝑛𝑛𝑒𝑒𝑒𝑒 ∙ 31 𝑘𝑘𝑎𝑎𝑎𝑎∙ ∙𝑑𝑑𝑓𝑓0,8
0,8 𝑑𝑑 ∙ 𝑙𝑙𝑒𝑒𝑒𝑒,𝑡𝑡𝑒𝑒𝑒𝑒∙ ( 31𝑎𝑎𝑎𝑎∙)𝑑𝑑 0,8
∙ 𝑙𝑙𝑙𝑙∙𝑒𝑒𝑒𝑒,𝑡𝑡
0,9 0,9 𝑒𝑒𝑒𝑒,𝑡𝑡 350 𝑓𝑓𝑙𝑙𝑎𝑎𝑎𝑎,𝑘𝑘
𝑛𝑛 𝑒𝑒𝑒𝑒
𝑒𝑒𝑒𝑒 = =𝑛𝑛10 𝑁𝑁𝑁𝑁𝑁𝑁𝑁2
0,8 ∙∙ 𝑙𝑙𝑙𝑙𝑒𝑒𝑒𝑒,𝑡𝑡
𝑎𝑎𝑎𝑎,𝑘𝑘 0,8 0,9 𝑒𝑒𝑒𝑒
𝑒𝑒𝑒𝑒,𝑡𝑡
31 ∙ 𝑑𝑑 ∙ 0,9 31
350
31 ∙∙ 𝑑𝑑
𝑑𝑑 0,8 ∙ 𝑙𝑙 0,9
𝑒𝑒𝑒𝑒,𝑡𝑡
0,9 𝐹𝐹 𝑎𝑎𝑎𝑎,𝑘𝑘 =
𝑓𝑓𝑎𝑎𝑎𝑎,𝑘𝑘 = 10 𝑁𝑁𝑁𝑁𝑁𝑁𝑁2 ∙ 𝑛𝑛𝑒𝑒𝑒𝑒point side penetration length
𝐹𝐹𝑎𝑎𝑎𝑎,𝑘𝑘 =
𝐹𝐹 = 𝐹𝐹 𝑎𝑎𝑎𝑎,𝑘𝑘2 =
𝑒𝑒𝑒𝑒,𝑡𝑡
𝐹𝐹𝑎𝑎𝑎𝑎,𝑘𝑘 = 1,5∙∙ 𝑛𝑛 𝑛𝑛𝑒𝑒𝑒𝑒 22 𝑒𝑒𝑒𝑒,𝑡𝑡
𝑒𝑒𝑒𝑒,𝑡𝑡2
𝑒𝑒𝑒𝑒,𝑡𝑡 ∙∙ 𝑛𝑛
𝑛𝑛𝑒𝑒𝑒𝑒
𝑒𝑒𝑒𝑒 1,5 ∙ cos 2 (𝛼𝛼) +sin 𝑙𝑙 : 2effective
(𝛼𝛼)
𝑎𝑎𝑎𝑎,𝑘𝑘
Characteristic 1,5 ∙∙ cos 2 (𝛼𝛼) +sin
costensile 𝐹𝐹 𝑎𝑎𝑎𝑎,𝑘𝑘
strength: (𝛼𝛼)
= 1,5
Gewindewiderstand
𝑎𝑎𝑎𝑎,𝑘𝑘 ∙∙ cos
𝑒𝑒𝑒𝑒 2
cos 2(𝛼𝛼)
(𝛼𝛼) für+sin
+sin
2
22(𝛼𝛼)
Schrauben(𝛼𝛼) 𝑒𝑒𝑒𝑒
∙ 𝑛𝑛in 𝑙𝑙𝑒𝑒𝑒𝑒: effective
𝑒𝑒𝑒𝑒 Brettsperrholz point
ermittelt side𝑒𝑒𝑒𝑒penetration length
1,5 2 (𝛼𝛼) +sin 𝑎𝑎𝑎𝑎,𝑘𝑘
Gewindewiderstand für Schrauben in Brettsperrholz ermittelt
2 (𝛼𝛼)
1,5 ∙ cos 2 (𝛼𝛼) +sin 2 (𝛼𝛼) 𝑒𝑒𝑒𝑒 𝑓
of the = 19,1
threaded kN part
sich nach Blaß und Uibel (2009): of the threaded part tens,k
sich Zugtragfähigkeit Schraube: 𝜌𝜌 : characteristic density of the timber
𝑓tens,knach Blaß und
Zugtragfähigkeit
Zugtragfähigkeit
Uibel
Schraube:
Schraube:
(2009):
Zugtragfähigkeit
Zugtragfähigkeit Schraube:
Schraube: 𝜌𝜌𝑘𝑘: characteristic density 𝑘𝑘
of the timber
for stainless steel screws:
Zugtragfähigkeit Schraube: 𝑓𝑓 0,9 𝑛𝑛𝑒𝑒𝑒𝑒 = 𝑛𝑛0,9 𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 = 19,1 𝑘𝑘𝑘𝑘
𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 𝑓𝑓
𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘
𝑛𝑛 𝑒𝑒𝑒𝑒 = 𝑛𝑛= 19,1 𝑘𝑘𝑘𝑘
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 𝑓𝑓
𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘
𝑓𝑓 𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 == 13,019,1
19,1 kN 𝑘𝑘𝑘𝑘
tens,k = 𝑘𝑘𝑘𝑘
0,9
𝑓𝑓 𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 31 ∙ 𝑑𝑑 0,8 ∙ 𝑙𝑙𝑒𝑒𝑒𝑒,𝑡𝑡 𝑓𝑓 𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 = 19,1 𝑘𝑘𝑘𝑘 𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘
31 ∙ 𝑑𝑑 0,8 ∙𝑓𝑓 𝑙𝑙 0,9
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘
𝐹𝐹𝑎𝑎𝑎𝑎,𝑘𝑘
𝑒𝑒𝑒𝑒,𝑡𝑡 = ∙ 𝑛𝑛𝑒𝑒𝑒𝑒
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 = 19,1 𝑘𝑘𝑘𝑘
𝐹𝐹 𝑎𝑎𝑎𝑎,𝑘𝑘 =
Criterium:
Zusammen: Zusammen: 1,5∙ 𝑛𝑛 ∙ cos 2
𝑒𝑒𝑒𝑒 (𝛼𝛼) +sin (𝛼𝛼)
2 Zusammen:
Zusammen: 1,5 ∙ cos 2 (𝛼𝛼) +sin Zusammen: 2 (𝛼𝛼)
𝐹𝐹𝑎𝑎𝑎𝑎,a,Rk ∙ 𝑘𝑘𝑚𝑚𝑚𝑚𝑚𝑚/𝛾𝛾𝑚𝑚
𝐹𝐹 Zusammen:
∙ 𝑘𝑘 /𝛾𝛾 𝐹𝐹 ∙ 𝑘𝑘 /𝛾𝛾
𝐹𝐹𝑎𝑎𝑎𝑎,𝑡𝑡,𝑅𝑅𝑅𝑅 = 𝑚𝑚𝑚𝑚𝑚𝑚 {{ 𝐹𝐹𝑎𝑎𝑎𝑎,a,Rk
= 𝑚𝑚𝑚𝑚𝑚𝑚
𝑎𝑎𝑎𝑎,a,Rk
𝐹𝐹 ∙ 𝑘𝑘𝑚𝑚𝑚𝑚𝑚𝑚=
𝑚𝑚𝑚𝑚𝑚𝑚 /𝛾𝛾𝑚𝑚 𝑚𝑚
𝑚𝑚𝑚𝑚𝑚𝑚 𝐹𝐹 𝑎𝑎𝑎𝑎,a,Rk
𝑎𝑎𝑎𝑎,a,Rk
{{ Schraube: ∙ 𝑘𝑘 𝑚𝑚𝑚𝑚𝑚𝑚
𝑚𝑚𝑚𝑚𝑚𝑚 /𝛾𝛾 𝑚𝑚
𝑚𝑚 𝐹𝐹𝑎𝑎𝑎𝑎,𝑡𝑡,𝑅𝑅𝑅𝑅 = 𝑚𝑚𝑚𝑚𝑚𝑚 {
𝐹𝐹 𝐹𝐹
Zugtragfähigkeit
𝑎𝑎𝑎𝑎,𝑡𝑡,𝑅𝑅𝑅𝑅
𝑎𝑎𝑎𝑎,𝑡𝑡,𝑅𝑅𝑅𝑅 = 𝑚𝑚𝑚𝑚𝑚𝑚 𝐹𝐹𝑎𝑎𝑎𝑎,a,Rk
𝑎𝑎𝑎𝑎,a,Rk ∙ 𝑘𝑘𝑚𝑚𝑚𝑚𝑚𝑚
𝑓𝑓
𝑎𝑎𝑎𝑎,a,Rk 𝑚𝑚𝑚𝑚𝑚𝑚/𝛾𝛾𝑚𝑚
/𝛾𝛾
𝑚𝑚𝑚𝑚𝑚𝑚 𝑚𝑚
𝑚𝑚 𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡/𝛾𝛾𝑚𝑚𝑚
Zugtragfähigkeit
𝑎𝑎𝑎𝑎,𝑡𝑡,𝑅𝑅𝑅𝑅 𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡
Schraube:
𝑓𝑓 /𝛾𝛾𝑚𝑚𝑚= 𝑚𝑚𝑚𝑚𝑚𝑚 {
𝑎𝑎𝑎𝑎,𝑡𝑡,𝑅𝑅𝑅𝑅
𝐹𝐹𝑎𝑎𝑎𝑎,𝑡𝑡,𝑅𝑅𝑅𝑅
/𝛾𝛾
𝑎𝑎𝑎𝑎,𝑡𝑡,𝑅𝑅𝑅𝑅 𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡/𝛾𝛾𝑚𝑚𝑚 𝑚𝑚𝑚
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡
𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 𝑚𝑚𝑚 𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡/𝛾𝛾𝑚𝑚𝑚
𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡 𝑚𝑚𝑚
𝑚𝑚𝑚 𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 = 19,1 𝑘𝑘𝑘𝑘
𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 = 19,1 𝑘𝑘𝑘𝑘
Zusammen:
Zusammen: 𝐹𝐹Druckschrauben Tragfähigkeit der Druckschrauben
Tragfähigkeit der
der𝐹𝐹Druckschrauben
Druckschrauben
Tragfähigkeit der 𝑎𝑎𝑎𝑎,a,Rk ∙ 𝑘𝑘𝑚𝑚𝑚𝑚𝑚𝑚/𝛾𝛾𝑚𝑚
Tragfähigkeit Tragfähigkeit
∙ 𝑘𝑘𝑚𝑚𝑚𝑚𝑚𝑚=
𝐹𝐹𝑎𝑎𝑎𝑎,𝑡𝑡,𝑅𝑅𝑅𝑅
Tragfähigkeit
𝑎𝑎𝑎𝑎,a,Rk /𝛾𝛾𝑚𝑚 der
𝑚𝑚𝑚𝑚𝑚𝑚
der{ Druckschrauben
Druckschrauben
𝐹𝐹𝑎𝑎𝑎𝑎,𝑡𝑡,𝑅𝑅𝑅𝑅 = 𝑚𝑚𝑚𝑚𝑚𝑚 { 𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡/𝛾𝛾𝑚𝑚𝑚
Knicktragfähigkeit:𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡 /𝛾𝛾𝑚𝑚𝑚
Knicktragfähigkeit: Knicktragfähigkeit:
𝑑𝑑𝑠𝑠 = = 5,95,9 𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚 𝑑𝑑
𝑑𝑑 = 5,9 𝑚𝑚𝑚𝑚 𝑑𝑑𝑠𝑠 = 5,9 𝑚𝑚𝑚𝑚
Knicktragfähigkeit: 2
Knicktragfähigkeit:
Knicktragfähigkeit: 2 2
𝑑𝑑
𝐼𝐼 𝑠𝑠= 𝜋𝜋𝜋𝜋4 ∙ 𝑑𝑑 2 2 𝑑𝑑𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠 == 5,9 5,9 𝑚𝑚𝑚𝑚
𝑚𝑚𝑚𝑚 22 𝑓𝑓𝑦𝑦𝑦𝑦 = 500 𝑁𝑁𝑁𝑁𝑁𝑁𝑁2
𝐼𝐼𝐼𝐼𝑠𝑠𝑠𝑠 == 𝜋𝜋𝜋𝜋4
𝜋𝜋𝜋𝜋4 ∙∙ 𝑑𝑑 𝑑𝑑𝑠𝑠2 𝐼𝐼𝐼𝐼𝑠𝑠𝑠𝑠𝑠𝑠 = = 𝜋𝜋𝜋𝜋4
𝜋𝜋𝜋𝜋4 ∙∙ 𝑑𝑑
𝑑𝑑 𝑠𝑠𝑠𝑠2
𝑠𝑠2 𝑓𝑓𝑠𝑠𝑦𝑦𝑦𝑦 =
𝑓𝑓 = 500500 𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁
𝑠𝑠 2 𝑓𝑓 𝑓𝑓 𝑦𝑦𝑦𝑦 =
𝑦𝑦𝑦𝑦 = 500
500 𝑁𝑁𝑁𝑁𝑁𝑁𝑁
𝑁𝑁𝑁𝑁𝑁𝑁𝑁 22
𝑠𝑠 𝐼𝐼 𝑠𝑠𝑠𝑠
= 𝜋𝜋𝜋𝜋4 ∙ 𝑑𝑑 2
22𝑠𝑠𝑠𝑠 𝑁𝑁 𝑦𝑦𝑦𝑦 = 𝜋𝜋 (Schraube 2 𝑓𝑓
∙ 𝑑𝑑𝑠𝑠 /4 ∙ 𝑓𝑓einseitig 𝑦𝑦𝑦𝑦
𝑦𝑦𝑦𝑦 = 500 𝑁𝑁𝑁𝑁𝑁𝑁𝑁 2
𝛽𝛽 = 0,7 (Schraube einseitig eing
𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘 = = 𝜋𝜋 𝜋𝜋 and 𝑑𝑑𝑠𝑠22/4 𝛽𝛽𝑝𝑝𝑝𝑝,𝑘𝑘= 0,70,7 𝑦𝑦𝑦𝑦𝛽𝛽 𝑦𝑦𝑦𝑦 = 0,7
∙∙ 𝑑𝑑 /4 ∙∙ 𝑓𝑓
𝑓𝑓𝑦𝑦𝑦𝑦𝑁𝑁
Stability load 𝑁𝑁 carrying 𝑝𝑝𝑝𝑝,𝑘𝑘 =
= 𝜋𝜋 𝜋𝜋 ∙∙ 𝑑𝑑 𝑠𝑠2/4
𝑑𝑑capacity
𝑠𝑠2 /4 ∙∙ 𝑓𝑓 𝑦𝑦𝑦𝑦 of the compression screws 𝛽𝛽 = eingespannt)
0,7 (Schraube einseitig eingespannt)
𝑁𝑁 𝑝𝑝𝑝𝑝,𝑘𝑘 𝑠𝑠 𝑦𝑦𝑦𝑦𝑁𝑁
Tragfähigkeit 𝑝𝑝𝑝𝑝,𝑘𝑘
𝑝𝑝𝑝𝑝,𝑘𝑘 = 𝜋𝜋 ∙ 𝑑𝑑𝑠𝑠𝑠𝑠𝑠𝑠der
𝑝𝑝𝑝𝑝,𝑘𝑘 2 ∙ 𝑓𝑓𝑓𝑓𝑦𝑦𝑦𝑦
/4 Druckschrauben
𝑦𝑦𝑦𝑦
𝑦𝑦𝑦𝑦
𝛽𝛽
𝑠𝑠
=
= 𝛽𝛽 ∙ 𝑙𝑙
(Schraube einseitig 𝛽𝛽
𝑙𝑙 : = 0,7
Knicklänge
(Schraube
(Schraube einseitig
eingespannt)
(Schraube einseitig eingespannt)
einseitig
(Dämmstärke +
eingespannt)
eingespannt)
Putzdicke) 𝑙𝑙f: Knicklänge (Dämmstärke + Put
Tragfähigkeit der Druckschrauben 𝑙𝑙𝑙𝑙ff:: Knicklänge
Knicklänge (Dämmstärke
(Dämmstärke ++ Putzdicke)
Putzdicke)
𝑠𝑠𝑠𝑠𝑘𝑘𝑘𝑘 = = 𝛽𝛽 𝛽𝛽 ∙∙ 𝑙𝑙𝑙𝑙f 𝑠𝑠𝑠𝑠𝑘𝑘𝑘𝑘𝑘𝑘 = 𝑝𝑝𝑝𝑝,𝑘𝑘 𝛽𝛽 ∙∙ 𝑙𝑙𝑙𝑙fff 𝑦𝑦𝑦𝑦 𝑘𝑘 f 𝑙𝑙𝑙𝑙fff:: Knicklänge (Dämmstärke + Putzdicke)
f2 2 𝑠𝑠𝑘𝑘𝑘𝑘 = = 𝛽𝛽 𝛽𝛽 ∙ 𝑙𝑙ff 22 222 𝑁𝑁
𝐸𝐸 = = 𝜋𝜋
170000 2
/(𝑠𝑠 2
) ∙
𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁 𝐸𝐸 𝐸𝐸 ff∙ 𝐼𝐼Knicklänge
= 170000 (Dämmstärke + Putzdicke)
𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁 𝐸𝐸 𝑠𝑠 = 170000 𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁
𝑁𝑁
Stability
𝑁𝑁 𝑘𝑘𝑘𝑘,𝑘𝑘 = 𝜋𝜋 of2 /(𝑠𝑠the𝑘𝑘2screw:) ∙ 𝐸𝐸𝑠𝑠𝑁𝑁 ∙𝑘𝑘𝑘𝑘,𝑘𝑘
𝐼𝐼𝑠𝑠 =
Knicktragfähigkeit:
𝑁𝑁 𝑘𝑘𝑘𝑘,𝑘𝑘 = 𝜋𝜋
𝜋𝜋 2/(𝑠𝑠
2
/(𝑠𝑠 2) )) ∙∙∙ 𝐸𝐸𝐸𝐸 𝑠𝑠𝑠𝑠𝑠𝑠 ∙∙∙ 𝐼𝐼
𝐼𝐼𝐼𝐼𝑠𝑠𝑠𝑠𝑠𝑠 𝐸𝐸 𝑘𝑘𝑘𝑘,𝑘𝑘
𝑠𝑠 = 170000 𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁 𝑘𝑘 𝑠𝑠𝐸𝐸
𝑑𝑑
ds𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠= = 170000
𝑠𝑠 5,9
5,9 𝑚𝑚𝑚𝑚 𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁
mm
𝑘𝑘𝑘𝑘,𝑘𝑘 = 𝜋𝜋 /(𝑠𝑠𝑘𝑘 ) ∙ 𝐸𝐸𝑠𝑠𝑁𝑁∙𝑘𝑘𝑘𝑘,𝑘𝑘 𝐼𝐼 𝑘𝑘
𝑘𝑘 𝐸𝐸 = 170000 𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁
Knicktragfähigkeit: 𝑠𝑠 = 𝜋𝜋 2 /(𝑠𝑠 2
𝑘𝑘 𝐸𝐸 𝑑𝑑 𝑠𝑠
𝜆𝜆′0𝑠𝑠 = = 5,9
= 0,13 𝑚𝑚𝑚𝑚 𝜆𝜆000 = 𝜆𝜆 0 = 0,13
=0,13
𝑘𝑘𝑘𝑘,𝑘𝑘 𝑘𝑘 𝑠𝑠𝑠𝑠 𝑠𝑠𝑠𝑠
𝐼𝐼𝑠𝑠′′′𝑘𝑘𝑘𝑘,𝑘𝑘 ==𝜋𝜋𝜋𝜋4 ∙ 𝑑𝑑/𝑁𝑁 2 𝑘𝑘
𝜆𝜆𝜆𝜆 0 =0,13 √ 𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘 /𝑁𝑁𝑘𝑘𝑘𝑘,𝑘𝑘2 𝜆𝜆𝑓𝑓 𝑓𝑦𝑦𝑦𝑦
𝜆𝜆 =
== 0,13
500N/mm²
0,13
1000 𝑁𝑁𝑁𝑁𝑁𝑁𝑁for 2
carbon steel
𝐼𝐼𝜆𝜆𝑠𝑠′′𝑘𝑘==
𝜆𝜆 =𝜋𝜋𝜋𝜋4
√ 𝑁𝑁 ∙ 𝑑𝑑 4
2
/𝑁𝑁 𝑘𝑘𝑘𝑘,𝑘𝑘 𝜆𝜆𝑘𝑘𝜆𝜆 √
′𝑘𝑘 = √𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘 𝑁𝑁 𝑠𝑠
𝑝𝑝𝑝𝑝,𝑘𝑘2/𝑁𝑁𝑘𝑘𝑘𝑘,𝑘𝑘 𝑓𝑓 𝑘𝑘
𝛼𝛼𝑦𝑦𝑦𝑦= = 0,875 500
0,875 𝑁𝑁𝑁𝑁𝑁𝑁𝑁 𝛼𝛼 00 𝛼𝛼 = 0,875
𝑓yk= 0,875
𝑘𝑘𝑘𝑘,𝑘𝑘 yk
𝑘𝑘 √𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘
𝑝𝑝𝑝𝑝,𝑘𝑘 /𝑁𝑁 𝑠𝑠 𝑘𝑘𝑘𝑘,𝑘𝑘
𝑁𝑁𝑘𝑘′𝑘𝑘 = =
𝜆𝜆 √𝑁𝑁 𝜋𝜋𝑝𝑝𝑝𝑝,𝑘𝑘
∙ 𝑑𝑑𝑠𝑠/𝑁𝑁
𝑝𝑝𝑝𝑝,𝑘𝑘 /4𝑘𝑘𝑘𝑘,𝑘𝑘∙ 𝑓𝑓𝑦𝑦𝑦𝑦
𝑘𝑘𝑘𝑘,𝑘𝑘 𝛼𝛼 𝛼𝛼
𝛽𝛽
𝛼𝛼 ===0,8750,7
0,875 (Schraube
500 N/mm² einseitig
for eingespannt)
stainless steel
𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘 = 𝜋𝜋 ∙ 𝑑𝑑𝑠𝑠2/4 ∙ 𝑓𝑓𝑦𝑦𝑦𝑦′ 𝑘𝑘𝑝𝑝𝑝𝑝,𝑘𝑘 𝑝𝑝𝑝𝑝,𝑘𝑘 𝑘𝑘𝑘𝑘,𝑘𝑘 𝛽𝛽 = 0,7 (Schraube einseitig
′ eingespannt)
′ 2
𝑘𝑘 = 0,5 0,5 ∙ (1 + 𝛼𝛼 ∙ (𝜆𝜆
= 𝛽𝛽 ∙ 𝑙𝑙∙f(1 + 𝛼𝛼 ∙ (𝜆𝜆𝑘𝑘
Berechnungskonzept
𝑠𝑠′ −
𝑘𝑘 =
==𝜆𝜆0,5𝛽𝛽0 ))∙ 𝑙𝑙+
+∙∙f(1 𝜆𝜆′′𝑘𝑘+
2
+2 𝛼𝛼 𝛼𝛼 ∙∙ (𝜆𝜆 (𝜆𝜆′′𝑘𝑘′′′𝑘𝑘 − − 𝜆𝜆 𝜆𝜆00))) + + 𝜆𝜆
′′ 2 22
𝜆𝜆′𝑘𝑘′′𝑘𝑘22
𝑘𝑘 = 0,5 ∙ (1 + 𝛼𝛼 ∙ (𝜆𝜆𝑘𝑘𝑙𝑙β :−
f=
𝜆𝜆0 )(Screw
Knicklänge
0,7 + 𝜆𝜆𝑘𝑘(Dämmstärke + Putzdicke)
with fixed support at one end)
𝑠𝑠𝑘𝑘𝑘𝑘= 𝑘𝑘𝑘𝑘𝑘𝑘𝑘𝑘− = 𝜆𝜆0,5
0,5
0 ∙ (1
(1𝜆𝜆
2 𝑘𝑘+ 2𝛼𝛼 ∙ (𝜆𝜆𝑘𝑘 𝑘𝑘 − 𝜆𝜆0
𝑘𝑘 0 + 𝜆𝜆𝑘𝑘
0 𝑘𝑘
𝑘𝑘
𝑙𝑙f: Knicklänge (Dämmstärke Ɩf 𝑠𝑠==free
𝐸𝐸
+ Putzdicke)
screw length
170000 𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁 (from the wood to the screw head)
2 2 Die𝑁𝑁𝑘𝑘𝑘𝑘,𝑘𝑘 = 𝜋𝜋 /(𝑠𝑠𝑘𝑘 Kraft
einwirkende ) ∙ 𝐸𝐸𝑠𝑠wird ∙ 𝐼𝐼𝑠𝑠 in Zug- und Druckräfte 𝐸𝐸𝑠𝑠 = 170000 𝑁𝑁𝑁𝑁𝑁𝑁𝑁𝑁 aufgeteilt und von ′ den Schrauben durch die
𝑁𝑁𝑘𝑘𝑘𝑘,𝑘𝑘 = 𝜋𝜋 /(𝑠𝑠𝑘𝑘 )1∙ 𝐸𝐸𝑠𝑠𝑓𝑓ü𝑟𝑟 ∙ 𝐼𝐼𝑠𝑠 𝜆𝜆′′ < 0,2 1 𝑓𝑓ü𝑟𝑟 𝜆𝜆′′′ < 0,2 1 𝑓𝑓ü𝑟𝑟 𝜆𝜆E0s = =𝜆𝜆210000
𝑘𝑘 < 0,2
0,13 N/mm² for screws made of carbon steel
1 Dämmung
𝑓𝑓ü𝑟𝑟
𝜆𝜆 ′ 𝜆𝜆𝑘𝑘
= √ 𝑁𝑁 0,2/𝑁𝑁 1
𝑘𝑘 < geleitet
1 und 𝑓𝑓ü𝑟𝑟
𝑓𝑓ü𝑟𝑟 ins𝜆𝜆𝜆𝜆Holz ′′𝑘𝑘 < 0,2
𝑘𝑘
𝑘𝑘 < weitergegeben.
0,2 𝜆𝜆0 = 0,13 E = 160000 N/mm² for screws made of stainless steel
𝜆𝜆′𝑘𝑘𝑐𝑐 =
𝜅𝜅 ={ { 𝑘𝑘 𝑝𝑝𝑝𝑝,𝑘𝑘 𝑘𝑘𝑘𝑘,𝑘𝑘 𝑘𝑘
𝑘𝑘 𝜅𝜅𝑐𝑐 = { 𝛼𝛼 = 0,875
√𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘 /𝑁𝑁𝑘𝑘𝑘𝑘,𝑘𝑘2 𝜅𝜅 𝑐𝑐𝑐𝑐𝑐𝑐 = 2{
s
𝜅𝜅 √ 𝜅𝜅
𝜅𝜅 =
=′2 {
{ ′ 2 2 0,2 ′′′ 2 2 ′′′ 𝛼𝛼 = 0,875 1/(𝑘𝑘 + √𝑘𝑘 2 − λ0 𝜆𝜆=′ 20,2 𝑓𝑓ü𝑟𝑟 𝜆𝜆′𝑘𝑘 ≥ 0,2
𝑐𝑐 1/(𝑘𝑘 + 𝑘𝑘 − 𝑐𝑐 𝜆𝜆 1/(𝑘𝑘 𝑓𝑓ü𝑟𝑟 + 𝜆𝜆√
√ 𝑘𝑘 ≥ − 𝜆𝜆 2 𝑓𝑓ü𝑟𝑟 𝜆𝜆 ≥ 0,2 𝑘𝑘
1/(𝑘𝑘 + √𝑘𝑘 2Die −𝑘𝑘
′ =𝑘𝑘 0,5
𝑐𝑐𝜆𝜆Tragfähigkeit
𝑘𝑘 1/(𝑘𝑘

∙ 𝑓𝑓ü𝑟𝑟
(1 + +2𝜆𝜆𝛼𝛼 √𝑘𝑘der
′ 2
𝑘𝑘∙≥(𝜆𝜆 −
2 0,2
2 Zugschrauben
′ 𝜆𝜆𝑘𝑘
𝑘𝑘 − 𝜆𝜆𝑘𝑘′𝑘𝑘𝑘𝑘𝜆𝜆0 ) +𝑓𝑓ü𝑟𝑟
′𝑘𝑘2 2
𝜆𝜆′𝑘𝑘 𝜆𝜆𝜆𝜆ist
2 𝑘𝑘 abhängig
′′𝑘𝑘 ≥ 0,2 vom Gewindewiderstand α = 0,49 im Holz und der
)1/(𝑘𝑘 𝑘𝑘 𝑘𝑘 − 𝑓𝑓ü𝑟𝑟 𝑘𝑘 ≥ 0,2
𝑘𝑘
𝑘𝑘
𝐹𝐹 = 0,5 = ∙𝜅𝜅(1∙+ 𝑁𝑁 𝛼𝛼 ∙ (𝜆𝜆 𝐹𝐹 𝑘𝑘 − 𝜆𝜆0=
Zugtragfähigkeit. +𝜅𝜅 𝜆𝜆∙′𝑘𝑘𝑁𝑁 Die Tragfähigkeit der
𝑘𝑘 𝐹𝐹𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 = 𝜅𝜅𝑐𝑐 ∙ 𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘
Druckschrauben ist abhängig vom Gewindewiderstand im Holz
𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 = 𝜅𝜅𝑐𝑐 ∙ 𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘 𝐹𝐹
𝐹𝐹𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 = 𝜅𝜅𝑐𝑐𝑐𝑐 ∙ 𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘
𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 𝑝𝑝𝑝𝑝,𝑘𝑘
𝑐𝑐 𝑝𝑝𝑝𝑝,𝑘𝑘 𝐹𝐹𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 = 𝜅𝜅𝑐𝑐𝑐𝑐𝑐𝑐 ∙ 𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘 𝑝𝑝𝑝𝑝,𝑘𝑘
und dem
𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 Knickwiderstand 𝑝𝑝𝑝𝑝,𝑘𝑘
1 𝑓𝑓ü𝑟𝑟 bzw.
𝜆𝜆 ′
< der
0,2 freien Schraubenlänge im Bereich der Dämmung.
1 𝑓𝑓ü𝑟𝑟 𝜆𝜆′𝑘𝑘 < 0,2 𝑘𝑘
Gewindewiderstand :
Gewindewiderstand Gewindewiderstand
Gewindewiderstand 𝜅𝜅 : 𝑐𝑐 = {
Gewindewiderstand
: :: 2
𝜅𝜅 = { Gewindewiderstand
Tragfähigkeit 1/(𝑘𝑘 der
+ √ Zugschrauben
𝑘𝑘 2 − 𝜆𝜆 : ′
𝑓𝑓ü𝑟𝑟 𝜆𝜆 ′
≥ Analog
0,2 zur Zugtragfähigkeit
Analog 1/(𝑘𝑘
𝑐𝑐 zur Zugtragfähigkeit
Zugtragfähigkeit
+ √𝑘𝑘 2 − Analog
Analog 𝜆𝜆′𝑘𝑘 zur
2
zur Zugtragfähigkeit
𝜆𝜆′𝑘𝑘 ≥ 0,2 𝑘𝑘
Zugtragfähigkeit 𝑘𝑘
Analog zur Analog zur𝑓𝑓ü𝑟𝑟 Zugtragfähigkeit
Zusammen: 𝐹𝐹 𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 = 𝜅𝜅𝑐𝑐 ∙ 𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘 für Schrauben in Vollholz
Gewindewiderstand Zusammen:
𝑛𝑛 ∶∶oder BSH Druckschrauben
Anzahl Werte für 𝑑𝑑 =Druckschrauben
8 𝑚𝑚𝑚𝑚 : 𝑛𝑛 ∶ Anzahl Druckschrauben
𝐹𝐹𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 = 𝜅𝜅𝑐𝑐 ∙ 𝑁𝑁𝑝𝑝𝑝𝑝,𝑘𝑘 Zusammen:
Zusammen: Zusammen: 𝑛𝑛 Anzahl Druckschrauben 𝑛𝑛
𝑛𝑛
𝐹𝐹𝑎𝑎𝑎𝑎,𝑘𝑘
∶ Anzahl
∙∶∶screwAnzahl
𝑘𝑘𝑚𝑚𝑚𝑚𝑑𝑑 /𝛾𝛾𝑚𝑚Druckschrauben
𝐹𝐹 Zusammen:
ermittelt ∙ 𝑘𝑘 sich
/𝛾𝛾 nach 𝐹𝐹
𝐹𝐹ETA 11/0027:

𝑎𝑎𝑎𝑎,𝑘𝑘 ∙ 𝑘𝑘𝑚𝑚𝑚𝑚𝑑𝑑 𝑘𝑘 𝑚𝑚𝑚𝑚𝑑𝑑/𝛾𝛾𝑚𝑚/𝛾𝛾 𝑚𝑚 𝑛𝑛
𝛼𝛼: Anzahl
axis Druckschrauben
- grain direction
𝐹𝐹𝑎𝑎𝑎𝑎,𝑘𝑘
𝑎𝑎𝑎𝑎,𝑘𝑘 ∙ 𝑘𝑘𝑚𝑚𝑚𝑚𝑑𝑑 /𝛾𝛾𝑚𝑚
𝐹𝐹∙𝑎𝑎𝑎𝑎,𝑐𝑐,𝑅𝑅𝑅𝑅 𝑚𝑚𝑚𝑚𝑑𝑑= 𝑚𝑚 𝑚𝑚𝑚𝑚𝑚𝑚 {{ 𝑛𝑛
𝑎𝑎𝑎𝑎,𝑘𝑘
𝐹𝐹𝑎𝑎𝑎𝑎,𝑘𝑘
𝑎𝑎𝑎𝑎,𝑘𝑘 ∙ 𝑘𝑘𝑚𝑚𝑚𝑚𝑑𝑑 𝑚𝑚𝑚𝑚𝑑𝑑 /𝛾𝛾𝑚𝑚 𝑚𝑚𝜌𝜌𝑘𝑘 0,8 𝐹𝐹𝑎𝑎𝑎𝑎,𝑐𝑐,𝑅𝑅𝑅𝑅 = 𝑚𝑚𝑚𝑚𝑚𝑚 { 𝑛𝑛𝑒𝑒𝑒𝑒 𝑘𝑘
𝐹𝐹
𝐹𝐹 𝑎𝑎𝑎𝑎,𝑐𝑐,𝑅𝑅𝑅𝑅 = 𝑚𝑚𝑚𝑚𝑚𝑚 {{ 𝑛𝑛 Gewindewiderstand
𝑛𝑛𝑒𝑒𝑒𝑒𝐹𝐹 𝐹𝐹𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅
𝑎𝑎𝑎𝑎,𝑐𝑐,𝑅𝑅𝑅𝑅 =
/𝛾𝛾 𝑚𝑚𝑚𝑚𝑚𝑚 𝑒𝑒𝑒𝑒 :∙∙ ∙𝐹𝐹
𝑎𝑎𝑎𝑎,𝑘𝑘 𝑚𝑚𝑚𝑚𝑑𝑑
/𝛾𝛾 𝑚𝑚 ∙ 𝑎𝑎𝑎𝑎
𝐹𝐹𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅
= 1,0 /𝛾𝛾𝑚𝑚𝑚
𝑎𝑎𝑎𝑎,𝑐𝑐,𝑅𝑅𝑅𝑅 = 𝑚𝑚𝑚𝑚𝑚𝑚
Withdrawal
Gewindewiderstand parameter: 𝐹𝐹
𝐹𝐹 : ∙ 𝑎𝑎𝑎𝑎,𝑐𝑐,𝑅𝑅𝑅𝑅
𝐹𝐹
𝑎𝑎𝑎𝑎,𝑐𝑐,𝑅𝑅𝑅𝑅
𝑎𝑎𝑎𝑎,𝑘𝑘 = 𝑛𝑛=
/𝛾𝛾 𝑚𝑚𝑚
𝑒𝑒𝑒𝑒 ∙ 𝑘𝑘
𝑚𝑚𝑚𝑚𝑚𝑚 𝑎𝑎𝑎𝑎 { ∙ 𝑛𝑛
𝑓𝑓 𝑒𝑒𝑒𝑒
𝑎𝑎𝑎𝑎,𝑘𝑘 𝐹𝐹𝑑𝑑 ∙
𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅
𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 𝑙𝑙 /𝛾𝛾
𝑒𝑒𝑒𝑒,𝑡𝑡 ∙ (
𝑚𝑚𝑚
𝑚𝑚𝑚 )
𝑒𝑒𝑒𝑒 𝑎𝑎𝑎𝑎,𝑐𝑐,𝑅𝑅𝑅𝑅 𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 𝑚𝑚𝑚 𝑒𝑒𝑒𝑒 ∙ 𝐹𝐹𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅
𝑒𝑒𝑒𝑒
𝑛𝑛screw 𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 /𝛾𝛾𝑚𝑚𝑚 𝑚𝑚𝑚350 𝑓𝑓𝑎𝑎𝑎𝑎,𝑘𝑘 = 10 𝑁𝑁𝑁𝑁𝑁𝑁𝑁2
See withdrawal capacity Analog of the zurtension Zugtragfähigkeit 𝑒𝑒𝑒𝑒 𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 𝑚𝑚𝑚
Analog zur Zugtragfähigkeit 𝑙𝑙𝑒𝑒𝑒𝑒: effective point side penetration length
Criterium: Gewindewiderstand für Schrauben in Brettsperrholz ermittelt
Zusammen: 𝑛𝑛: ∶the
of Anzahl
number ofDruckschrauben
threaded part
compression screws
Zusammen: sich nach Blaß und 𝐹𝐹 𝑛𝑛 ∶ Anzahl Druckschrauben
𝑎𝑎𝑎𝑎,𝑘𝑘 ∙(2009):
Uibel 𝑘𝑘𝑚𝑚𝑚𝑚𝑑𝑑 /𝛾𝛾𝑚𝑚 𝜌𝜌 : characteristic density of the timber
𝐹𝐹𝑎𝑎𝑎𝑎,𝑘𝑘
𝐹𝐹 ∙ 𝑘𝑘𝑚𝑚𝑚𝑚𝑑𝑑= /𝛾𝛾𝑚𝑚𝑚𝑚𝑚𝑚
𝑚𝑚 { 𝑛𝑛 ∙ 𝐹𝐹
𝑘𝑘
𝐹𝐹𝑎𝑎𝑎𝑎,𝑐𝑐,𝑅𝑅𝑅𝑅 = 𝑚𝑚𝑚𝑚𝑚𝑚 { 𝑛𝑛 ∙ 𝑎𝑎𝑎𝑎,𝑐𝑐,𝑅𝑅𝑅𝑅 𝑒𝑒𝑒𝑒 𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 /𝛾𝛾𝑚𝑚𝑚 𝑛𝑛𝑒𝑒𝑒𝑒 = 𝑛𝑛0,9
𝑒𝑒𝑒𝑒 𝐹𝐹𝑘𝑘𝑘𝑘,𝑅𝑅𝑅𝑅 /𝛾𝛾𝑚𝑚𝑚
31 ∙ 𝑑𝑑 ∙ 𝑙𝑙𝑒𝑒𝑒𝑒,𝑡𝑡 0,8 0,9
𝐹𝐹𝑎𝑎𝑎𝑎,𝑘𝑘 = ∙ 𝑛𝑛𝑒𝑒𝑒𝑒
1,5 ∙ cos 2 (𝛼𝛼) +sin2 (𝛼𝛼)

Zugtragfähigkeit Schraube:
𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡,𝑘𝑘 = 19,1 𝑘𝑘𝑘𝑘

Zusammen:
𝐹𝐹𝑎𝑎𝑎𝑎,a,Rk ∙ 𝑘𝑘𝑚𝑚𝑚𝑚𝑚𝑚/𝛾𝛾𝑚𝑚
Calculation 𝐹𝐹𝑎𝑎𝑎𝑎,𝑡𝑡,𝑅𝑅𝑅𝑅 = 𝑚𝑚𝑚𝑚𝑚𝑚 { 3
𝑓𝑓𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡𝑡/𝛾𝛾𝑚𝑚𝑚
The tables below gives an overview about the load carrying capacity for single screws according to the given equations.
Values for timber elements with an characteristic density of ρk = 350 kg/m³ an carbon steel screws.

Characteristic withdrawal parameter Fax,k Characteristic buckling capacity Fki,k


lef α = 45° / 90° lf Fki,k lf Fki,k
mm kN mm kN mm kN
40 3,20 60 21,1 160 7,3
45 3,60 65 20,2 165 6,9
50 4,00 70 19,3 170 6,6
55 4,40 75 18,4 175 6,3
60 4,80 80 17,5 180 6,0
65 5,20 85 16,6 185 5,7
70 5,60 90 15,8 190 5,5
75 6,00 95 14,9 195 5,2
80 6,40 100 14,1 200 5,0
85 6,80 105 13,3 205 4,8
90 7,20 110 12,6 210 4,6
95 7,60 115 11,9 215 4,4
100 8,00 120 11,2 220 4,2
Fax,d = kmod · Fax,k / γm 125 10,6 225 4,1
130 10,0 230 3,9
135 9,5 235 3,8
140 9,0 240 3,6
145 8,5 245 3,5
150 8,1 250 3,4
155 7,6
lf: free screw length
Fki,d = Fax,k / γm1 γm1 = 1,1

Minimum edge and end distances for screws


Values for screws with d= 8mm

Solid timber and glulam:


Distance to the stressed end of the center of gravity of the threaded
part of the screw in the timber: a3,c = 9 · d = 72 mm

Edge distance of the center of gravity of the threaded


part of the screw in the timber: a4,c = 4 · d = 32 mm

Cross lamintated timber, screws used in the plane surface:


Distance to the unstressed end grain of the center of gravity of the threaded
part of the screw in the timber: a3,c = 6 · d = 48 mm

Distance to the stressed end grain of the center of gravity of the threaded
part of the screw in the timber: a3,t = 6 · d = 48 mm

Distance to the unstressed edge of the center of gravity of the threaded


part of the screw in the timber: a4,c = 2,5 · d = 20 mm

Distance to the stressed edge of the center of gravity of the threaded


part of the screw in the timber: a4,t = 6 · d = 48 mm

4 ISO-CONNECT
ISO-CONNECT - fixing french balcony
The french-balcony is fixed to the façade with a total of four ISO-CONNECT connections. Thereby the ISO-Connectors
are situated left and right of the doorway and the french-balcony is fixed with M12 bolts.
Due to the support at four points, no eccentricity of the force F1 must be taken into account.

Dimension of the coupling plate: Ø 80 x 15 mm


Inclined screws: 2 x Ø 8 mm
Horizontal screws: 2 x Ø 8 mm

Note: The compression plate is already mounted at the french-balcony

Stress on the screws depending on the acting loads


Fs,Ed: Stress on the inclined screws FH,Ed: Stress on the horizontal screws

Direction
Direction FF
1
1
Direction
Direction F3F
3
Direction F4in
Beanspruchung
Richtung F4

F1,Ed
√ � �
� � �
F S,
Ed

ef ef ef

l
l

,S ,S ,S

lef,H lef,H lef,H


F4,Ed
F1,Ed F3,Ed F3,Ed F4,Ed
FH,Ed FH,Ed FH,Ed
15 15 15

F1,Ed √2 · F1,Ed
ISO-CONNECT ISO-CONNECT ISO-CONNECT
83200.0606 83200.0606 83200.0606

tD tD tD

Stress
Stresson on the screw
the screw: Stress
Stressonon the screw
the screw: Stress on the
Beanspruchung screw
der Schrauben:
Fs,Ed =Fs,Ed
√2= √· 2F· F1Ed
1,Ed
(Tension)
(tension) FH,Ed =FH,Ed
F3,Ed (Tension)
= F3,Ed (Tension) FH,Ed =FFH,Ed =(Compression)
F4,Ed (Druck)
4,Ed
= F=1,Ed
FH,EdFH,Ed F1,Ed(Compression)
(compression)

Design values of the load carrying-capacity


The tables are calculated with the given calculation model.
Version Thickness Horizontal screw Ø 8 Inclined and sideward screws Ø 8 Design load carrying-capacity
of the
Length threaded part in timber Length threaded part in timber kmod = 0,9
insulation
tD lh lef,h ls lef,s F1,Rd F3,Rd F4,Rd
mm mm mm mm mm kN kN kN
Insulation 60 60 160 75 220 100 7,3 7,8 7,8
Insulation 80 80 180 75 260 100 7,3 7,8 7,8
Insulation 100 100 220 95 280 100 5,7 5,7 5,7
Insulation 120 120 240 95 320 100 7,3 9,8 9,8
Insulation 140 140 260 95 340 100 7,3 9,8 9,8
Insulation 160 160 280 95 380 100 7,3 9,8 9,8
Insulation 180 180 300 95 400 100 7,3 9,8 8,7
Insulation 200 200 320 95 400 82 6,0 9,8 7,4
Insulation 220 220 340 95 400 54 3,9 9,8 6,3

The values are


​​ valid when using carbon screws and the following compostion: 15 mm Iso-Connect plate, 3 mm rubber panel, 5 mm plaster and thermal insulation
The penetration length of the threaded part of the horizontal partial threaded screw must be at least the effective threaded length but maximum 5 mm longer.
For combined stresses in direction F1 and F4 - direction, the forces resulting from the acting forces must be assigned to the screws and summed up.
The distribution of forces can be seen in the previous figures.

ISO-CONNECT - fixing french balcony 5


ISO CONNECT – fixing HVP 88210.3000
The HVP 88210.3000 is connected to the ISO-CONNECT with four M12. Due to the thickness of the HVP-connector
the rafter has a distance of 18 mm to the ISO-CONNECT. This eccentricity must be taken into account.

Dimension coupling plate: 90 x 100 x 15 mm


Inclined screws: 6 x Ø 8 mm
Horizontal screws: 6 x Ø 8 mm

Note: The HVP connector 88210.3000 is used as pressure plate.

Stress on the screws depending on the acting loads


Fs,o,Ed: Stress on the upper inclined screws Fs,u,Ed: Stress on the bottom inclined screw
FH,o,Ed: Stress on the upper horizontal screws FH,u,Ed: Stress on the bottom horizontal screw
Beanspruchung in Beanspruchung in
Direction F1 Direction F
Richtung F1 Richtung F3 3

S S
F S,

F1,Ed
O,
Ed

S S

e
F S,

�SO-�O��E�� ��1�����12 �SO��O��E�� �3�������2


U,
Ed

HVP ��21������ HVP ��2���3���

rafter rafter

H
F1,Ed · ea F1,Ed/2 H F3,Ed/2

FH,O,Ed F1,Ed/2 FH,O,Ed F3,Ed

a =50
a =50

H
F1,Ed /√2 H

F1,Ed · ea F1,Ed/2 F3,Ed/2


FH,U,Ed FH,U,Ed
F1,Ed /√2
F1,Ed/2
15 18 15 18

ST/GL
VH / BSH ST/GL
VH / BSH
BSPH
CLT BSPH
CLT
tD tD

Stress on the
Beanspruchung derscrew
Schrauben: Stress on theder
Beanspruchung screw
Schrauben:
FS,O,EdF=S,O,Ed
FS,U,Ed = F1,Ed
= FS,U,Ed = F/√2 (Tension)
1,Ed /√2 (Zug)
FH,O,EdF = FH,U,Ed
= F = F= F/2 /2
3,Ed
(Tension)
(Zug)
H,O,Ed H,U,Ed 3,Ed
e
FH,O,Ed =F F1,Ed/2
= F - F1,Ed- ·F a (Compression)
· ea (Druck)
H,O,Ed 1,Ed/2 1,Ed
e
FH,U,Ed = F1,Ed/2 + F1,Ed · a · (Compression)
e
FH,U,Ed= F1,Ed/2 + F1,Ed a (Druck)

Direction F4in
Beanspruchung Direction F5 | F��6
�������������
Richtung F4 �������� �� ���. ��

S
� ���
�E

ISO-CONNECT 83100.0912
S HVP 88210.3000

�SO��O��E�� ���������2
HVP ��2�������
���E�
rafter

H
H F4,Ed/2 rafter
S

FH,O,Ed F4,Ed H
�H�O�E���H���E� ���E�
a =50

S
H
H
���E� �2 ���E��
FH,U,Ed F4,Ed/2
15 18

ST/GL
VH � �SH
CLT
�SPH � ���E� �
15 18

ST/GL
VH / BSH
BSPH
CLT
tD ��

Stress on the
Beanspruchung derscrew
Schrauben: Stress on the���
������������� screw
S���������
FH,O,Ed F=H,O,Ed
FH,U,Ed
= F= F4,Ed
= /2 (Compression)
F4,Ed/2 (Druck) Fse,Ed = √2 · F5,Ed (Tension)
H,U,Ed ����E� � �2 � ���E� �����
FH,O,Ed = FH,U,Ed = F5,Ed/2 (Compression)
�H�O�E� � �H���E� � ���E��2 �������
6 ISO-CONNECT
Design values of the load carrying-capacity
The tables are calculated with the given calculation model.
The ccentricity is assumed with e = 18 mm.

Version Thickness Horizontal screw Ø 8 Inclined and sideward screws Ø8 Design load carrying-capacity
insulation
length threaded part in timber length threaded part in timber kmod = 0,9; e = 18 mm

tD lh lef,h ls lef,s F1,Rd F3,Rd F4,Rd F5/6,Rd

mm mm mm mm mm kN kN kN kN

Insulation 60 60 160 75 220 100 13,0 22,4 22,4 3,9

Insulation 80 80 180 75 260 100 13,0 22,4 22,4 3,9

Insulation 100 100 220 95 280 100 14,6 28,4 28,4 3,9

Insulation 120 120 240 95 320 100 14,6 28,4 28,4 3,9

Insulation 140 140 260 95 340 100 14,6 28,4 28,4 3,9

Insulation 160 160 280 95 380 100 14,6 28,4 28,4 3,9

Insulation 180 180 300 95 400 100 14,6 28,4 26,1 3,9

Insulation 200 200 320 95 400 82 12,0 28,4 22,1 3,2

Insulation 220 220 340 95 400 54 7,8 28,4 19,0 2,1

The values are only valid for carbon screws and the following compostion: 15 mm Iso-Connect plate, 3 mm rubber panel, 5 mm plaster and thermal insulation
If lef is greater than in the table, it is allowed to increase F5/6,Rd with the factor (lef,neu/lef).
The penetration length of the threaded part of the horizontal partial threaded screw must be at least the effective threaded length but maximum 20 mm longer.
For combined stresses in direction F1 and F4 - direction, the forces resulting from the acting forces must be assigned to the screws and summed up.
The distribution of forces can be seen in the previous figures.

ISO CONNECT – fixing HVP 88210.3000 7


ISO-CONNECT - universal connection
The universal connection system with a greater height and additional compression screws is optimized for higher
forces and eccentricity, to connect for example purlins. The connection is realized with a M20 bolt.

Dimension coupling plate: 120 x 155 x 15 mm


Inclined screws: 6 x Ø 8 mm
Horizontal screws: 8 x Ø 8 mm

Note: The compression plate is included in shipment.

Calculation
The load distribution is similar to the HVP connection. The additional eccentricity has to be taken into account.

�����������
Universal connection

e F����

rafter
purlin

15 6
10

��

Design values of the load carrying-capacity


The tables are calculated with the presented calculation model.
The maximum capacity is defined with the bolt-timber connection.
The load carrying-capacity are calculated for different purlin dimensions.

Bearing capacity M20 bolts - thick steel plate in single shear

Thickness of the purlin mm 60 80 100 120 140 160

Characteristic value kN 9,05 12,06 15,08 18,09 21,11 22,41

Design value for kmod = 0,9 kN 7,40 9,87 12,33 14,80 17,27 18,33

8 ISO-CONNECT
Version Thickness Horizontal Inclined and side- Design load carrying-capacity
insulation screw Ø 8 ward screws Ø8 kmod = 0,9

Length threaded Length threaded e= e= e= e= no influence of eccentricity


part in part in 40 mm 60 mm 80 mm 100 mm
timber timber

tD lh lef,h ls lef,s F1,Rd F1,Rd F1,Rd F1,Rd F3,Rd F4,Rd F5/6,Rd

mm mm mm mm mm kN kN kN kN kN kN kN

Insulation 60 60 160 75 220 100 14,59 14,59 12,82 11,22 29,91 29,91 3,91

Insulation 80 80 180 75 260 100 15,62 14,62 12,82 11,22 29,91 29,91 3,92

Insulation 100 100 220 95 280 100 14,62 14,62 14,62 14,21 37,88 37,88 3,92

Insulation 120 120 240 95 320 100 14,62 14,62 14,62 14,21 37,88 37,88 3,92

Insulation 140 140 260 95 340 100 14,62 14,62 14,62 14,21 37,88 37,88 3,92

Insulation 160 160 280 95 380 100 14,62 14,62 14,62 14,21 37,88 37,88 3,92

Insulation 180 180 300 95 400 100 14,62 14,62 14,62 13,04 37,88 34,78 3,92

Insulation 200 200 320 95 400 82 11,96 11,96 11,96 11,07 37,88 29,52 3,20

Insulation 220 220 340 95 400 54 7,82 7,82 7,82 7,82 37,88 25,35 2,10

The values are only valid for carbon screws and the following compostion: 15 mm Iso-Connect plate, 3 mm rubber panel, 5 mm plaster and thermal insulation
If lef is greater than in the table, it is allowed to increase F5/6,Rd with the factor (lef,neu/lef).
The penetration length of the threaded part of the horizontal partial threaded screw must be at least the effective threaded length but maximum 5 mm longer.
For combined stresses in direction F1 and F4 - direction, the forces resulting from the acting forces must be assigned to the screws and summed up.
The distribution of forces can be seen in the previous figures.

ISO-CONNECT - universal connection 9


Calculation
Proof of a french-balcony
Situation:
The french balcony is installed with two ISO CONNECTors on the left and right side of the doorway. Decisive for the
evidence are the upper connectors, due to the horizontal railing forces. The screws are screwed in in a CLT-element
with a thickness of 100 mm through the thermal insulation with 200 mm.

For the system solution the version "Insulation 200" is chosen. Horizontal screws: 8 x 300 partial threaded, threaded
part 100 mm; Inclined screws: 8 x 380 partial threaded, threaded part 80 mm

Load assumption:
Death weight balcony : gk = 0,4 kN/m
Horizontal load: hk = 1,0 kN/m
Vertical load: vk = 1,0 kN/m

Length of balcony railing: 1,00 m

Stresses on the connector:


F1,Ed = (1,35 * 0,4 + 1,5 * 1,0) * 1,0/2 = 1,02 kN
F3,Ed = F4,Ed = 1,5 * 1,0 *1,0/2 = 0,75 kN

Proof direction F1 with table values:


Insulation 200: F1,Rd = 6,0 kN
Proof: 1,02/6,0 = 0,17 < 1,0

Proof direction F3 and F4 with table values:


Due to the low values the combined proof is not shown.
Insulation 200: F4,Rd = 7,4 kN
Proof: 0,75/7,4 = 0,10 < 1,0

Proof rafter connection with HVP


Situation:
Installation of a 5 m wide canopy (projecting roof) on an existing building with a CLT-wall structure with a thickness of
100 mm and a thermal insulation of 140 mm. The rafters have a center distance of 800 mm.

For the system solution the version "insulation 140" is selected. Horizontal screws: 8 x 240 partial threaded, threaded
part 100 mm; Inclined and sideward screws: 8 x 320 partial threaded, threaded part 120 mm

Load assumption:
Death weight roof: gk = 0,5 kN/m²
Snow load: sk = 1,3 kN/m²
Wind load : wk = (0,8 + 0,5) * 0,65 = 0,85 kN/m²

Stresses on the connector:


F1,Ed = (1,35 * 0,5 + 1,5 * 1,3) * 5/2 * 0,8 = 5,25 kN
F5/6,Ed = 0,85 * 0,4 * 5/2 = 0,85 kN

Proof direction F1 with table values:


Insulation 140: F1,Rd = 14,6 kN
Proof: 5,25/14,6 = 0,36 < 1,0

Proof direction F5/6 with table values:


Insulation 140: F5/6,Rd = 3,9 kN
Proof: 0,85/3,9 = 0,22 < 1,0

10 ISO-CONNECT
Proof purlin connection with universal connector
Situation:
Installation of a 5 m wide canopy (projecting roof) on an existing building with a CLT-wall structure with a thickness of
100 mm and a thermal insulation of 140 mm. The rafters are supported on a purlin with 120/160 mm, which is fixed
with the universal connector to the facade.

Load assumption:
Dead weight roof: gk = 0,5 kN/m²
Snow load: sk = 1,3 kN/m²

Stress on the connector:


F1,Ed = (1,35 * 0,5 + 1,5 * 1,3) * 5/2 = 6,56 kN/m

Bearing capacity of the connector with e = 80 mm:


Insulation 140: F1,Rd = 14,6 kN (maßgebend)
maximum load capacity due to bolts (s.table): F1,Rd,max = 14,8 kN

Maximum spacing of the ISO-CONNECT: e = 14,6/6,56 = 2,23 m

The distance is chosen with 2,0 m.

ISO-CONNECT-Anschluss Französischer Balkon Ø 80x15 mm

Drawings of the coupling plate


2 Bohrungen Ø 9 mm versenkt
2 Bohrungen Ø 9 mm 45° versenkt
1 Gewindebohrung Ø 12 mm
4 Gewindebohrungen Ø 8mm

Ø 80
27,5
Coupling plate: 83200
20
Connection french balcony Ø 80 x 15 mm
- 2 bore holes 9 mm, counter-sunk
- 2 bore holes 9 mm, 45°, counter-sunk
- 1 threaded hole Ø 12 mm
- 4 threaded holes Ø 8 mm
20 20
ISO-CONNECT-Anschluss 88210.3000
6 Bohrungen Ø 9 mm versenkt
4 Gewindebohrungen Ø 12 mm
6 Bohrungen Ø 9 mm 45° versenkt

90
33
16,5
Coupling plate: 83100
Connection FL 90 x 100 x 15 mm, aluminium
34,34
33

- 6 bore holes 9 mm, counter-sunk


3
16
100

- 6 bore holes 9 mm, 45°, counter-sunk


- 4 threaded holes Ø 12 mm
29 29 ISO-CONNECT-Anschluss Universalanschluss
8 Bohrungen Ø 9 mm versenkt
4 Gewindebohrungen Ø 12 mm
1 Gewindebohrung Ø 20 mm
6 Bohrungen Ø 9 mm 45° versenkt
120
28 45
11

Coupling plate: 83300


Universal connection 120 x 155 x 15 mm
61,01
62,5

- 8 bore holes 9 mm, counter-sunk


25

- 6 bore holes 9 mm, 45°, counter-sunk


120
155
25

- 1 threaded hole Ø 20 mm
47,09
57,5

- 4 threaded holes Ø 8 mm

29

Drawings of the coupling plate 11


Fast, easy and
precisely to the best
solution
• Wood connectors
• Post bases
• Balcony/fence posts
• Tools / accessories
• Sound insulation for timber constructions
• always up to date with www.pitzl-connectors.com

We recommend our distribution partner:

Pitzl Metallbau GmbH & Co. KG Tel.: +49 (0) 8703 9346-0 Downloads, technical Need help? Contact to our
Siemensstraße 26 Fax: +49 (0) 8703 9346-55 Information, installation videos: competent employees:
DE-84051 Altheim, Germany info@pitzl-connectors.com www.pitzl-connectors.com +49 (0) 8703 9346-0

All rights reserved. Reproduction and publication - even in part - only with the permission of Pitzl Metallbau GmbH & Co. KG. Changes and errors excepted. Similar pictures. Date 03/2020.

You might also like