You are on page 1of 1

40-pin IDE Flash Module 2.

3.
Built-in ECC function assures high reliability of data transfer
Auto Sleep and Power-Down modes supported
Unlocked mode. When Jumper 1 is set to Unlock " ", the
40-Pin IDE Flash Module is Unlocked and you can read/write

Installation Guide
The 40-Pin IDE Flash Module offers 2 ways to get input power, either data from/to it. When Jumper 1 is set to Lock " ", the 40-
4. Write-Protect function supported
via the small power cord or through pin 20 of the IDE connector. If pin Pin IDE Flash Module is Locked. You can’t write data to the
5. LED indicates status of usage
20 of the IDE connector is defined as NC (No Connect), then the 40-
40-Pin IDE Flash Module, but you can read data from it.
Pin IDE Flash Module must be directly connected to your system’s
Before Use
Introduction power supply. If pin 20 of the IDE connector is defined as VCC, then
the 40-Pin IDE Flash Module can get necessary power without use of Lock
Electrostatic Discharge (ESD) can damage electronic Jumper 1
Transcend Information, Inc. manufactures 16MB, 32MB, 64MB, components. Before touching 40-Pin IDE Flash Modules or the power cord. Unlock

128MB, 256MB, 512MB and 1GB 40-Pin IDE Flash Modules. internal electronic components, ensure that you are free of
With an IDE interface and strong data retention ability, 40-Pin static electricity by first touching an unpainted, grounded metal 4. Plug the 40-Pin IDE Flash Module
IDE Flash Modules are ideal for use in the harsh environments object. Use of a grounded wrist strap is suggested. Keep 40-Pin 7. After you have inserted the 40-Pin IDE Flash Module,
into a 40-pin IDE connector on the
where Industrial PCs, Set-Top Boxes, etc. are used. The IDE Flash Modules away from heat, direct sunlight, and plugged in the power cord if necessary, and set the jumpers,
motherboard. Make sure pin 1 of the
following instructions provide general installation and handling moisture. Do not bend, flex, or drop 40-Pin IDE Flash Modules. close the protective case of your system or device, reattach
40-Pin IDE Flash Module is aligned
information, which should be used in conjunction with the any disconnected cables, and reconnect the AC power
with pin 1 of the IDE connector, and
Owner’s Manual for your device or system. Installation and Jumper Settings cord/replace the rechargeable battery.
that the 40-Pin IDE Flash Module is
well seated in the connector. 8. Power on your system or device and continue with the
Basic Specifications 1. Make sure your system (Industrial PC, Set-Top Box, etc.) is
following to configure your system or device to use the 40-Pin
powered off, and any AC power cord has been disconnected.
5. 40-Pin IDE Flash Modules, as with other IDE devices, can be IDE Flash Module.
Form Factor: 59.0mm x 27.3mm x 7.3mm If your system has a rechargeable battery, it should also be
Op. Voltage: 3.3V/5V removed. configured to function as either "Master" or "Slave" devices.
BIOS Setup
Op. Temperature: 0°C (32°F) to 85°C (185°F) 2. Follow the instructions in the Owner’s Manual for your device When Jumper 2 is set to the Master position, the 40-Pin IDE
Data Retention: Up to 10 years or system to open the protective case, gain access to the Flash Module will act as a Master device. When Jumper 2 is 1. Power on your system and follow the on-screen instructions
Shock Resistance: 1000 G Max. motherboard, find a power cord to the power supply if set to the Slave position, the 40-Pin IDE Flash Module will act to enter BIOS or the CMOS Setup Utility.
Weight: 11g Max. necessary, and locate IDE connectors. Also refer to your as a Slave device. 2. Refer to the Owner’s Manual for your system for details about
Owner’s Manual for your device or system for IDE pin the configuration program for your system.
Features definition details. 3. Enter STANDARD CMOS SETUP and find the correct menu
Master
3. If necessary, carefully connect the tiny plug on the 40-Pin IDE Slave
Jumper2 item (device name) for your 40-Pin IDE Flash Module (i.e.,
1. Fully compatible with devices and operating systems (OS) Flash Module to the provided short power cord, and then IDE Primary Master, IDE Primary Slave, IDE Secondary
that support the IDE standard (pitch = 2.54mm) connect it into an available power cord from the power supply. Master, or IDE Secondary Slave). Select Auto for Auto-
6. 40-Pin IDE Flash Modules can be set to either Locked or Detection of device parameters and press ESC.

40-pin IDE Flash Module 40-pin IDE Flash Module 40-pin IDE Flash Module 40-pin IDE Flash Module

the Unlocked mode, the 40-Pin IDE Flash Module can be


used like any HDD to store data or run programs. You may
The device name selected for 40-Pin IDE Flash Module depends on
whether the 40-Pin IDE Flash Module was inserted into either the
even install your OS to the 40-Pin IDE Flash Module.
Primary or Secondary IDE connector, and whether Jumper 2 was set
to Master or Slave.
Removal Procedures 40-pin IDE Flash Module
Phoneix - AwardBIOS CMOS Setup Utility
IDE Primary Master
1. Make sure your system (Industrial PC, Set-Top Box, etc.) is
powered off, and any AC power cord has been disconnected. If Installation Guide
your system has a rechargeable battery, it should also be removed.
IDE HOD Auto-Detection [Press Enter] Item Help
2. Follow the instructions in the Owner’s Manual for your device TS16MDOM40V
IDE Primary Master [Auto] Menu Level
Access Mode [Auto]
To auto-detect the
or system to open the protective case, gain access to the TS32MDOM40V
HDD's size, head... on motherboard, and locate the 40-Pin IDE Flash Module in the
Capacity 0 MB
this channel TS64MDOM40V
IDE connector.
Cylinder 0
Head 0 3. Disconnect the power cord of the 40-Pin IDE Flash Module TS128MDOM40V
Precomy 0
Landing Zone
Sector
0
0
from the power supply. Grasp the upper edges of the 40-Pin TS256MDOM40V
IDE Flash Module and carefully unplug it from the 40-pin IDE TS512MDOM40V
connector of the motherboard.
:Move Enter:Select +/-/PU/PD:Value F10:Save ESC:Exit F1:General Help
TS1GDOM40V
F5: Previous Values F6: Fail-Safe Defaults F7: Optimized Defaults Setup & Ordering Information
Transcend P/N Capacity Cylinders (C) Heads (H) Sectors (S)

If your system doesn’t support Auto-Detection, please select User, TS16MDOM40V 16MB 248 4 32
Manual, or similar option, and manually enter the number of TS32MDOM40V 32MB 496 4 32
cylinders, heads, and sectors for the 40-Pin IDE Flash Module. (See
Setup & Ordering Information for these values.) TS64MDOM40V 64MB 978 4 32
( Version 1.0 )
TS128MDOM40V 128MB 978 8 32
4. Choose Save & Exit Setup to save the new configuration to
TS256MDOM40V 256MB 978 16 32
w w w. t r a n s c e n d u s a . c o m CMOS and exit the CMOS Setup program. At SAVE to
CMOS and EXIT (Y/N)? Type Y and press Enter. TS512MDOM40V 512MB 993 16 63
5. Reboot your system. TS1GDOM40V 1GB 1985 16 63
6. Your 40-Pin IDE Flash Module is now ready for use. If set in
P/N:88-2690 2003.11.20000

40-pin IDE Flash Module 40-pin IDE Flash Module 40-pin IDE Flash Module