The most appropriate method for performing lockout/tagout on a chemical storage tank
is to empty the tank and:

A. Lock the dead-man switch in the open position.


B. Isolate and lockout power to the pump.
C. Perform “double-blind and bleed” on all input lines.
D. Activate and lock the fire prevention valve.

(Solution on next page)

1.866.264.5852 | support@bowenehs.com
www.BowenEHS.com
Copyright © 2021 Bowen EHS – A Division of Bowen Learning Network, Inc.
Professional Development for Health & Safety Experts

Solution:

The proper method is to install two blank or “blind” flanges in the input lines to a
chemical storage tank, install a valve between the blind flanges, and lock the valve in
the open position. This method is called “double-blind and bleed.”

The correct solution is C.