You are on page 1of 2

Product Specification

03225C

LCS Series
Integrated
Engine Speed
Control

• Fully integrated
actuator and
speed control
DESCRIPTION integrated into a rotary diesel fuel pump
and one integrated with a throttle body • Small package–
The Woodward LCS Integrated Engine (product spec 03223) or a throttle body greater design
Control System is the first engine speed and mixer (product spec 03222). The
externally mounted systems can be
flexibility
control to deliver so much in a package
this compact. configured for clockwise or counter- • Suitable for
clockwise (standard) shaft rotation for
It can also deliver a big savings in increasing fuel.
gasoline,
production and field support. Since the gaseous, and
LCS Control System is microprocessor- To learn more about the new LCS Series diesel fueled
based, it can easily be programmed to integrated engine control, contact
Woodward today. engines
match the operating parameters of every
engine you produce. All it takes is a PC LCS control features: • Microprocessor-
and a simple, plug-in download on your • operates fuel or air control with 0.34 based
production line. Nxm (0.25 lb-ft) torque (60° travel
range) • Tamperproof
With many built-in functions, this
microprocessor-based speed control • end-of-line programmability simplifies
allows a high-volume OEM or packager to inventory
stock one part number, but implement a • optional transient smoke limiter for
wide variety of engine control strategies turbocharged diesel engines
by configuring the four auxiliary inputs at • customer configurable auxiliary inputs
their factory. available on board to match your
specific application
Besides the traditional bracket mount • optional mounting kits for Stanadyne
using external linkage, the LCS Control DB-series or Delphi DP200 & DP210
System is available in a variety of fuel injection pumps provides
mechanical configurations, including one integrated control solution

Standard Additional
Configuration Part Numbers Comments
Bracket Mounted 0116-02-000
Stanadyne DB2/4 Pump 02-0042-004 (OEM) See Woodward manual 26098.
8404-563 (Packager) See Woodward manual 26187
Delphi DP200/210 Pump 8404-513 See Woodward manual 26155
Flexible design.
Woodward
More intelligent engine control.
Industrial Controls Streamlines production process.
PO Box 1519 Specifications
Fort Collins CO, USA Power Supply 12 volt system, 8 to 16 Vdc
80522-1519
1000 East Drake Road Power Consumption Reverse polarity protection, 64 W max
Fort Collins CO 80525 Torque 0.34 Nxm (0.25 lb-ft)
Ph: +1 (970) 482-5811 Dimensions (WxHxL) 75.7 x 88.4 x 111.3 mm (2.98 x 3.48 x 4.38 in.)
Fax: +1 (970) 498-3058
Weight 425 g (15 oz)
Connector 12-pin Deutsch connector (DT06-12SA-P012)
Distributors & Service
Woodward has an Control Characteristics
international network of Speed Input and Range Magnetic pickup, ignition coil, or DIS input
distributors and service MPU input: 100 to 12 000 Hz with <5 kΩ impedance @ max
facilities. For your nearest
representative, call the
frequency
Fort Collins plant or see IGN input: 1, 2, 3, 4, 5, 6, & 8 cylinder engines with rated speeds
the Worldwide Directory of 1200–4000 rpm
on our website. Target speed: programmable
Actuator Torque High-efficiency torque motor; delivers 0.34 Nxm (0.25 lb-ft)
Corporate Headquarters (60° travel range) to operate fuel or air control
Rockford IL, USA Steady State Speed
Ph: +1 (815) 877-7441 Regulation Fuel Type Gasoline Diesel Gaseous
MPU input ±0.35% ±0.25% ±0.35%
www.woodward.com
Ignition input ±0.50% n/a ±0.50%
Functions/Auxiliary Inputs
Function Options Isochronous Speed (50 or 60 Hz); Two or Three Speed; Droop;
Positioner; Start Fuel Limiter; Load Sharing; Dual Dynamics;
Adjustable Max Fuel Stop; Manifold Air Pressure Biased Fuel
Limiter; Cold Start Timer; Self-tuning Gain
Programming Port Programmable with Windows GUI software and harness
02-0004-174
AUX1 Options Auxiliary Load Sharing, Remote Speed Setting, MAP Fuel
Limiting, 50/60 HZ Select, Isoch. Load Sharing/Droop Select;
Positioner (0–5 V input)
AUX2 Options Lower Speed, Isoch. Speed Control/Droop Select, Isoch. Load
Sharing/Droop Select, Idle/Rated Select, Three Speed Select
AUX3 Options Raise Speed, Dual Dynamics Select, Three Speed Select
AUX4 Options 50/60 Hz Select, Isoch. Speed Control/Droop Select, Isoch. Load
Sharing/Droop Select, Dual Dynamics Select, Three Speed
Select
AUX5 Options Permanently configured as an output to drive a relay
Environment
Ambient Operating
Temperature –40 to +85 °C (–40 to +185 °F)
Storage
Temperature –40 to +125 °C (–40 to +257 °F)
EMI/RFI EN 50081-2(Emissions) EN 055082-2(Immunity)
Shock/Vibration US MIL-STD 810E
Compliance
UL/cUL Listed (UL requires a Class 2 power source or isolated source)
This document is distributed CE Compliant
for informational purposes
only. It is not to be construed
as creating or becoming part
of any Woodward Governor For more information contact:
Company contractual or
warranty obligation unless
expressly stated in a written
sales contract.

© Woodward Governor
Company, 2000
All Rights Reserved

03/3/F