Tabwelya 6 ‘CONVERTING INDUSTRIES COMPANY LONGITUDINAL REVERSION TEST REPORT Test & Product Characteristics Data Work Order No. Sample Test Date 10.08.2014 Pipe Diameter & Size DN 110 Drainage pipe Pipe Batch No. 10062018 ‘Type of Material , Lot No. TASNEE 100 BLACK Minimum Thickness 42mm ‘Mean OD 110.25 mm Length Of Test Piece 200 mm Reference standard ISO 2505 / EN 1519 Test Temperature io0°c#2°C Duration of Exposure in Oven Hour Conditioning Period 2Hour @ 23°C#2°C Specification Value 53% Number of Test Plece 3 Pcs. Distance Between the a 989 Marks after Heating 2 99.01 (mm) 3 99.1 Result ( Average Reversion ) % 1.00% culation : Ri - Longitudinal Reversion (%) . ne bet Lo Distance between the marks before heating, (mm) * LL- Distance between the marks after heating , (mm) (Observation and inference ; h.. passed lp Fest Conducted By : —_ 8) _taboratory Tech ‘Technician Ay TKE> TESTS) was COW EEAHEO, (ft At Jeddah: Te 966 (02) 6857666 Fax «996 (02) 6959424 wwwTahwelya.com ‘Yanbu: Tot «966 (04) 3212111 Fax +986 (04) 3213111 SAO OMTIPIY Gish MUTE OFYVTNNY Gla eae Info@Tahwelya.com POBox: 17740 Jeddah 21494 Kingdom Of Saudi Arabia Apap uy padt ASLAN YVEAL Ge WES a Ge. GR 4og0199061 C.c 141171 VENI. LP ATATY Sg AME D MENTE gst MeN TT