You are on page 1of 2

PRODUCT DATA

30A Wireless Load Control Module


lumina™ RF

30A Wireless Load Control Module


APPLICATION Additional Leviton Lumina™ RF products include
Wireless controls for water heaters, pool pumps, thermostats, heavy-duty load control modules,
outdoor fountains, etc. Ultra low stand-by power. and a general purpose plug-in module to enable
Universal 96-250 VAC and 50/60 Hz. Can be a complete wireless energy management
used outdoors. system.

Functionality
FEATURES AND BENEFITS
Using wireless mesh technology, the load control
• UL Listed for outdoor use
module acts as an interrupter to turn devices on
• Wireless remote control of water heaters,
or off based upon schedules or manual control
pool pumps, outdoor fountains, etc.
via apps and Touchscreens.
• Includes current measurement capabilities
for instantaneous demand
THE LUMINA™ RF FAMILY • Load energized: 0.25 watt (considered
Leviton’s powerful wireless Lumina™ RF family “standby” as this is a load-shedding device)
ensures energy savings in new construction • Load de-energized: 1.4 watt
and retrofit in small applications. Scalable
from single location to franchise to enterprise, Dimensions
with company-wide holidays and schedules 5.25” H X 4.25” W X 2.25” D
easily managed for all locations. Control lights,
lamps, fans, shades, pumps, and Somfy window
WARRANTY INFORMATION
coverings.
Two-Year Limited Warranty

Leviton Manufacturing Co., Inc. Global Headquarters


201 N. Service Rd. Melville, NY 11747-3138 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538

Leviton Manufacturing Co., Inc. Energy Management, Controls and Automation.


4330 Michoud Blvd., New Orleans, LA, 70129 Tel: 1-504-736-9810 Fax: 1-504-253-2954

Visit our Website at: www.leviton.com/gateway


©2016 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
PRODUCT DATA

WIRING DIAGRAMS NOTE:


This control is not suitable for use as a
disconnecting means. The installation
may require a separate disconnect in
accordance with appropriate electrical
codes and regulations.

DISCONNECT
DISCONNECT

POWER CONSUMPTION
(NOT INCLUDING ATTACHED LOAD
0.25W STANDBY (LOAD ENABLED)
1.40W ACTIVE (LOAD DE-ENERGIZE
30A Wireless Load Control Module

POWER CONSUMPTION
(NOT INCLUDING ATTACHED LOAD):
0.25W STANDBY (LOAD ENABLED)
1.40W ACTIVE (LOAD DE-ENERGIZED)

ORDERING INFORMATION
DESCRIPTION CAT. NO.

30A Wireless Load Control Module 73A00-3ZB

Leviton Manufacturing Co., Inc. Global Headquarters


201 N. Service Rd. Melville, NY 11747-3138 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538

Leviton Manufacturing Co., Inc. Energy Management, Controls and Automation.


4330 Michoud Blvd., New Orleans, LA, 70129 Tel: 1-504-736-9810 Fax: 1-504-253-2954

Visit our Website at: www.leviton.com/gateway


©2016 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice. SAT-10061

You might also like