You are on page 1of 54
ASME B73.3-2015 [Revision of ASME B73.3-2003 (R2008)] Specification for Sealless Horizontal End Suction Centrifugal Pumps for Chemical Process AN AMERICAN NATIONAL STANDARD CY The American Society of Pan Specification for Sealless Horizontal End Suction Centrifugal Pumps for Chemical Process AN AMERICAN NATIONAL STANDARD Ce MU a oy ee nea ‘his Standord ll be revised when the Soclety approves the Isuance ofa new edition. There will be no writen interpretations ofthe requirements ofthis Standard issued to this edition Pesioically certain actions of the ASME 873 Committee may be published a Cases. Cases are published onthe ASME Web site under the 873 Committee Page t ga.asme.org/B73eommites 25 they ae issued, Errata to codes and standards maybe posted on the ASME Web ste under the Commitee Pages to provide coretons to incarecty published items, orto corect typographical or grammatical errs In codes ané standads. Such evata shall be used on the date posted ‘he 873 Commitee Page canbe found at go.asme.org/873commitee. There isan option aalable to automaticaly receive an e-mail ntfcaton when erata ar posted to apartcular ode or standard. ‘Thisopton canbe found onthe appropriate Commitee Page ate selecting “Erata"inthe=Publiation Information” section, ‘ASME i the sepsteedcemat fTe Ameen Sty of Mahan Engines. 1 as developed under pede adel as meting the ite or Amesan National ‘ems mntoned inte cums doe a ndete tse yoneuig sans seine Hiya ‘vse ht cetermination oe veya ny Suh pen i, andthe fk ogee Sh VANS, “nets own respon, roth elec et) peo) afte wh si wt Be we as "SME aces sponsor ony thee eprtaons of document eve in acutace mth theta ASME cers ad poles ih pete te sua a hereon y sels The Ameran Sac af Mechanar "oP ven, Hen Yo MY 100365990, CONTENTS Foreword Commitee Roster Correspondence With the B73 Comte 1 Scope. 2 References 3 Alternative Designs 31 Extended Length Pump Design 32 Close Coupled Design 33 Altemative Design 4 Nomenclature and Definitions 41 Definitions of Terms 42 Aditional Deinitions 5 Design and Construction Features. 51 Presse and Temperate Limits 52 Flanges 53 Casing S4 Impeller 55 Internal Drive Assembly 56 Containment Design 57 Bearings, Lubrication, and Bearing Frame (MDP) 58 Outer Magee Assembly (MDP) 59 Stator Assembly (CMI) 510 Materials of Construction S11 Auailary Piping 512 Corronon Allowance 513 Dimction of Rotation S18 Dimensions 515 Miscellaneous Design Features S16 Monitoring Devices 6 General Information. 61 Application 62 Performance Curves 63 Tests and Inspections 64 Nameplates 7 Documentation 21 General 72 Requirements 73 ‘Document Desctption 74 Specially Requested Documentation Figures SAS1-1 Cooling and Heating Pipe Plans 55551 Plan 114 Modified Sied-1 CMP Vibration Messurement Locations 731-41 Pump and Driver Outine Drawing for Separately Coupled Magnetic Drive Pumps 731-2 Pump and Driver Outline Drawing for Canned Motor Pumps uw 4 4 15 15 5 15 15 16 v 18 18 2» 20 21 a a1 a1 a Fs 25 2% 2% 2% 2 2 3 Y 3 3 3 co ” » 2 2 3 Tables nt Pump Dimension fr Separately Coupled Magnetic Dive Pumps 12 Baseplate Dimensions for Separately Coupled Magnetic Drive Pumps 21 ——_Aaceplate Dimensions for Close Coupled Magnetic Drive Pups 351 Pump Dimensions for Canned Motor Pumps 32 Bbceplte Dimensions for Canned Motor Pumps 510.1241 Magnetic Drive and Canned Motor Pump Material Classification Codes 5101.31 ASTM Materal Specifications SIILIT Minimum Requirements for Ausliary Piping Materials 6151 Approximate Hydraulic Coverage, 0 Hz 6152 Approximate Hydraulic Coverage, 60 H2 6161-1 Minimum Continuous Flow ‘Mandatory Appendix r [ASME Selless Centrifugal Pump Data Sheet Nonmandatory Appendix Av Electronic Data Exchange FOREWORD ln 1991 the ASME Standards Committee B73, Chemical Standard Pumps, formes a scales ‘pump working group to develop a standard for selless pumps that would correspond to [ASME B73.1M, Specfeation for Horizontal End Suction Centrifugal Pumps fr Chemical Proce "Though these pumps are sealless ie, they donot use a dynamic sel to prevent leakage around the deve shaft), leakage can cacur asa real of etain types oF Went or misoperation. The use ‘must take appropriate supplemental safety precautions when operating thse pumps “The first edition of this Standard was approved as an American National Standard on August 7, 1957, Inthe intervening years, work continued on a revision of ASME B73.IM. As that work deew near to completion, the sealless working group began to develop a revision ofthe 1957 edition (EASME H72.3M to reflect the changes being made in ASME B721M, The 2003 revision of the [ASME B73: Standard include *'Some paragraphs were simplified and clarified “The presentation of units was changed to refit thatthe US. Customary nits were the primary “units oF measurement, 1 The sections on flanges anal flange loading were revised + Sound and vibration requirements were revise, + information concerning “Operating Region” and “NPSH Margin” was added. + Auxiliary connection symbols were added {Additonal pump sies were ade “Table 3 was revised to reflect changes inthe Frame 1 pump dimensions. “Table 7, Minimum Continuovs low, as ade + Form 1'was revised to reflect additonal nequied values This revision ofthe Standant includes several changes to reduce redundancy inthe B73 set of standards and to better align with the Hydraulic Istute standards. Revisions have alo been ‘madeto further improve the wiabilty of he B73.3 pumps Reference snovt made othe Hydenie Institute standard for fluid circulation piping plans. A materia lasfcation covehasbeen added 108713. The table for ASTM material specications has been expanded snd table fr minimum, requirements fo ausiary piping materials has been added. Requirements forthe bearing frame have been revised to assure more robust pumps. Plstic nad magnetic dive pumps have been added tothe scope ofthe standard due to their prevalence throughout the chemical industry. ‘Close coupled pumps ate also an option and close coupled punsp bseplales have been shortened accordingly. The default performance test acceptance race has been revised to reflec the new FHI/ISO peefocmance test standard, More deal was added tothe requlred drawings: curve and locumentation that shoul! be inciadel with the pump. A new datasheet has been develope fd ade tothe standard, The standard endorses the Electronic Data Exchange standard which ‘was developed by the Hydraulic Istitate and FIATECH Automating Equipment Information Exchange (AEX) project. ‘Suggestions for improvement of this Standard wil be welcome and should be ent to The “American Society of Mechanical Engineers, Attn: Secretary, B73 Committe, Two Park Avenue, New York, NY 10006-5990 This Standard was approved as an American National tandlard on October 30, 2015. ASME B73 COMMITTEE Chemical Standard Pumps (efoto ter he amie tein fap his Standard) ‘STANDARDS COMMITTEE OFFICERS. Chrome, sce ‘STANDARDS COMMITTEE PERSONNEL 1.8 bunt, out MB Haber, Rowse Ca 5. Wows sot, fot USShamer, fest Pompe 16. day, ower Cor Row Salations Soup ‘ric, east USt ES srt one pw Sins ars re ops LF Denk, MPSCO CW. Par, tenate Met ro Gab! Pump Saison Ra tate, Te Daw Chemie Nesta cause Pang Cl coma, he nein Sty of Mahal Engines kag tera I ous amps CORRESPONDENCE WITH THE B73 COMMITTEE General. ASME Standards are developed and maintained with the intent to represent the consensus of concerned inert, Assuch, user ofthis Standard may inet with the Commitee by proponing revisions or a Cave and attending Committee meeting. Comespondence shoul be addressed Secretary, B73 Standards Commitee ‘The American Society of Mechanical Engineers ‘Two Park Avenue New York, NY 10016-5990 ups go. asmeeg/Inguley Proposing Revisions. Revisions are made perio tothe Standard to incorporate changes that appear necessary or desirable, as demonstrated by the experience gained fom the application ofthe Standard. Approved revisions will be published periodically. "The Committee welcomes proposals for revision to this Standard, Such proposals should be as specie as possible, citing the paragraph number(s), the proposed wording, and 8 detailed Seszrption of the reasons forthe proposal, including any pertinent documentation Proposing a Case. Cases may be issued for the purpose of providing alterative rules when Justified, to permit early implementation of an approved revision when the need is urgent, oF provide rules not covered by existing provisions. Cases are effective immediately upon [ASME approval and shall be posted on the ASME Committee Web page. Raquens for Cases shall provide a Statement of Need and Background Information. The request, should identity the Standard and the paragraph, figure, or table number(s), and be writen as 2 ‘Question and Reply in the same format as existing Cases. Requests for Case shoul ls nicate the applicable edition(s) ofthe Standard to which the proposed Case applies ‘Attending Committee Meetings. The 873 Standards Committee regularly holds meetings and/or telephone conferences that are open tothe public. Persons wishing to attend any meeting and/or telephone conference should contact the Secretary ofthe B73 Standards Committe. Future Committee meting dates and locations can be found on the Committer Page at go.asmeory/B7Scommitte. INTENTIONALLY LEFT BLANK SPECIFICATION FOR SEALLESS HORIZONTAL END SUCTION CENTRIFUGAL PUMPS FOR CHEMICAL PROCESS a scope This Standard isa design and specification standard that covers metalic and platen sales centefugal pumps of horizontal end ston single stage centerine ‘lscharge design. This Standard includes dimensional interchangeably requirement and certain design fear tures to facilitate Installation and maintenance and tenance reliability and safety of B73.3 pumps the Intent ofthis Standard that pumps ofthe same standard a, A o — we yy Designation Diameter CP Woe (2H ot (2_Mote (228 F [Mote (a) ote 2} Diameter Keyoay Min. (Note (2) Note (a) de teay 32° Gare sk) tak an Gas ays Gaye Gam xaoe 2st MD ote] 6 xa x10 BS 10 98 75 as 17S Ges ass aus os Kai le Bs ‘Table 1-1 Pump Dimensions for Separately Coupled Magnetic Drive Pumps (Cont'd) ‘Sato x charg * Te Bi Delgaton Diameter GP Pte ete] Mote) 2h Fo) Mote Oiameter —_Naywny nN te Boo ae 6 A TS 975 738 2s 7s ous BS LS 025 ROMS 2 st 590 eS) 8 eT se Ms a6) 9 tay hrs ors Mas 19s Oeaseom ee sooo Nate} t0 8 188 Ms 681875 47S 087s MS 27S oMKOI A og Ries hate] "6 kts 8 sie 3 tay bars Oars sas onmwomn tee Riohaesl $5655 Res is ie Stays bars oars as das ommworn tie Aizoinnte ] 10 8 xis 338 sie 3 tars bars oars Saas ommwom 4 ie Avosinnte(o}§ 4 x17 338 Ms 168 1875 m7 087s MMS 27S oMHOD A Atolwte(S] 8 xe mir 3388 sie} tars bars oars ms das osmwom tis Mzoinnte Gl 10 xe xi does seas tas Te tars mars oays S278 ose die (3) Se pn 3.1. Tsatenced gh simension C3 manu vate, Ay ineaan betwee the andar pd minim extend Inthe aca (2) or dose couples pumps on imeson 0,2, 0%. ah Y pe 1) Uma be 605m amt oA hush Dae ecommodate igh re vals, (0 Dschae ange ma have apes bat tes (5) Setar Range may have ppd Bl holes ‘Table 1-1M__Pump Dimensions for Separately Coupled Magnetic Drive Pumps i [epotnaeEqcnlet inet. am Sein > scage Tine Sinession Namie npr ee fe ° xy Osiaton Diameter CP ete) Mote] Mote N26 Fete _H_Nae AH lamer Keyway woe te 5e ote (oy Bn So Tso as Seta) tahoe de oR 23 yeacaae St test a Wore) Ma 35200 aes Sey TS 0 take de doen) yoveaae St test 8 (ote) 80% 40x30 MASSA? Haha THK ITE SMe 1D 305 ate con "Sax 35350 Sor Fak NDB seas hse sas gre ao inne oy iso 100% 250 Sor kaskus AAS Se SoSH Gas aab roe oo ft "eax 40300 Sop Fas 28k Ra HBSS S20 RSE aI a? 2a? 102 320 ote Y50% 1003300 Sor 72h a8k aka as de Sor ase GF 390 (hte S] Yon 150330 860.1013 Hah HOG DaD are gt 775 OS SATIN HOP Mae ‘100 (at 250% 200x530 860 $013 eh 40G=«229 are wD. ASAT IO AST SD Divs hate} 150% 100x380 Sea 1013 uO 229 are wD 7S— OS AEX TIH 102 kOe AS? ‘io Mote] tox $50 380 Sco $012 aah dog «abn areas} bara So? ‘to tei] 250% 200360 Sco $0: ab Mog abs are cast} baa HOP Aa) ‘105 note] 150% s00%420 860 $012 6806S BD aD OTIS OD. ASAD TIN BOD Me 152 Aviolinte | 200-150-490 eo 1012 ask kena 7G gakuen rae doar S82 Aza ite]__250 200% 490 Beod_1019 S68 abso 76g )_est_ ana isane ron ion) 152 [3 Se pm 3. This eatended length mension Ce a maximum vue, Ay inersonbetnen the sad 12) Foro copied pump on imenon 0,2, 0% an pp 13) Uma be 128m ater n AS uth ABD Ses To commode gh rue aus. (6 Biche fang may have ape bal le 15) Seton range may have ppd Bl hes ‘Table 1-2 Baseplate Dimensions for Separately Coupled Magnetic Drive Pumps Mounting Teeaion i Maxam Reet m. 7 Na Mma” tes OL me im Frome fori orn. pote) WO eh tims D525 9-425 9-10 0=1050 ME _mr_foe(@]_Mom_mY MMO mo BB toe kb os som aS os (Nr hold nat eaten eed he end of te Bae (2) Cotact manufac fr atonal spae required fre tzning baseplate, 1) Reset number denaes pump fame 03 od sept oe ces. (6 Se p31 Te eatnced neh emerson Hla dle Whee the pp 9 8 Mout as Caster than CR he ase a Hk must be ed (5 ncuces 013 smi alomance where mtr Meh coal Table 1-2M_ Baseplate Dimensions for Separately Coupled Magnetic Drive Pumps ‘epost Egil melon, ik ainan —_Bacnen. is ema” ees, ie hoe a a te He. Frome fort fore ty. pote) _Rate(Q)_M_O= 953 D= 0 D254 D~3e8 HEM) oe HM oP met esr ta So er ii tie ir in Rohe [3 Motor shoud not extend od he endo the baseplate. (2 Cotact mantra spe rede fo 1) Beeps number denstes pump fame 20) ad sept Ho ie inches. (See pan 31 Tis eatence leh emerson Hea Te vale Whee! he pump 1 be Mout as CR wet han CF, the ase or Be ust be used (5 ncuces mm shining slowarce wher morn ona tang baseplate Table 2-1 Baseplate Dimensions for Close Coupled Magnetic Drive Pumps pose Nasi Besepae Ne a a wen” (SHES .00.601_, noe tate Frome For Fore nm, Mate Mote (Seles. (5]_O= 525 D=825 0-10 HE WotelS) (ots (U5) Mex HH MHP deareorense et st Bde ts ms dee te 2 aE ae Soasnererse ub 3S He is ts bs Sos te dS das (3) Nt hold nat eaten ood he end af thease (2) Contact manuactre for atonal pace requ fore staning septs 1) Roselle number denates pump fame 3 oan see 8 oF He niches, (6 Se pam Te Baepnte leh for esl be ured fr exended design Ths tended gh mention Sf 3d a, 15 Aterate baseplate ces able 2 asepateDimersions a Sep Coused Magne Dive Pugs my be used fr dose Coupled mage ive pumgs. (6 ncuces 013 imming onan whew moor Rel col Table 2-1M_ Baseplate Dimensions for Close Coupled Magnetic Drive Pumps eprint Dine, xia ct im, as te na” ees. 650 gaan aa ate, Frame __TrH® erie —_._ Wate WotCS]_Wotn((51_O= 133 0-250 0-264 HE _tNole GN Moen (LCS) MHP feoeremse tty ak tay stn move tm in wane @ Szeoense ee Seka) a tes Ts Boys thai tank ne Sosneerse oe 38a ae yee tis ts ho ue (3) Net stout not extn yo he endo te Baap. (2 Contac manta atonl spne require or Fe tenig baseplate 1) Baap mer denotes pump fame ior an Dept 0 Hen lime (a) Se pam 3 Te baseplate leh for sh be ured for esended desig Ths ended gh dimen 2 od wae, (5 Ate baspnte ce: abie 12M, Basen Dimension or Sepanfe Couples Magnetic Dive Pumps maybe se fo ve cused magne ve pumps (@ Incuzes 32m shinning sonar wher motor hei onal Table 3-1 Pump Dimensions for Canned Motor Pumps my RI] 4 :@ Dimension "Nomina neler ar fe eatin Dimer twee) Mate MeteC_ Maes D.OH HK be pea, = 3 ke Sass yas some Sas os [MoteO} set eR Sas 88 yas Masons HS 6s 38 eG] «3 ISK R525 6 72s as omas tS 6S 505 oe@y 3X3 Kao Sas ars Tas srs aas dors as 320 ute =k dD dose Tas ssa as as noo [tote] «3 dskt) tears Tas ass Oaas 208 tos be tea) =k teas Tas ess sas 500 feted} «8 8 sets sas Gas SOs te aico(uete gtx IDS aS Soa St Resins) gk kas deste tS ras 00S te Fr a Te Aupissted} aS IS tas te FSS BS BS auosiNote tg] gk KTS aS sows NOs Snowe) «8 xe aay es ets bas as Suisse] tos Rosie tas (3) terse pomp cae canned motor pangs do ot ee sme a nama supped by 3 pump cal under the forso arly mcmed pup coat neces (2 Sccpm Sc, tus cate Kap dhacnso fois a musi le, Ay cnenson stent smal an tinue ended 1) sehen may hav ppe bt holes (0 Suton Range may have ope Bot Nes Desinaton mote (sae (nae on EEQE EREE 205 tae 90 (ote 20 [hate 320 eco 790 ae 100 te ‘0s nate) Bato nate ‘0a 305 ae 2310 fe) ‘20 (terse panp cate Table 3M Sie icon « cage imp Dimensions for Canned Motor Pumps Aare Faint Dineen, mk nse) (2 See am. Te estnded nh Senin fe 3 minum al. ny dmerin betwen he stndad and maximum exended (0 Daehrge ange may ate poe Bl bles (6 Suton Rage may have ppd Do Nes. woe vate (mots) ne mor pnp do at ue sapien nd ae normaly supported by pump eae under the at Table 3-2 Baseplate Dimensions for Canned Motor Pumps. fe _| [oa Dimension Nominal impel Min. HA, Mas. HB, Mia. ‘WBe, Max. HD, Desinaton omer ate Naes 2) ets (ON ets GON an BC more ns B se & dats $3 estas rs a5 tas Ba ote ise xe B se @ Ga ts $83 Ges 7s rs a5 tas 28. ote) 2 wise a n 8 @ aa 7s 555 ss 475 O75 45125 205. ae) Pere ee B Ss @ Gers ss os Gs 1 aS tas 290 (woe) 6a ae ise 93 775 Oe 8s 220 [ae Sisk B By ise 93 775 Oe 83s 390 ate 9.0) 6 kk DB a ° Be 5s es as as 590 [Mats GLO] 8 ke RDB Es * MB 5s me es as a Table 3-2 _Baseplate Dimensions for Canned Motor Pumps (Cont'd) Dimension Nominal impel Min. HA, Mas, HB, Ma. ‘Woe, Mex. HO, Mase Max. NG, Designation Dome ae naes 2} ete (Hh O_otes CH, OH Man. Eee Nees O}_Man. Hm _H Rois 9,0) to x8 xB B 6 ” tas 8s wa 1S 428 ‘05 ae exe 6 = fe tos 98 sass TBs tas Rioiwses(s.@) 8 xe ets a = fe toms 98 sas aS TBs tas Apisete Gio] 10 BIS ae 2 te tos 93 RS TBS 38 105 ae) exer on 2 » was 9s sms aS 6s 125 atone Sxem of ae 2 bs os ss TBs as Rioisate lg] take a a 2 Bes 53 sss ts 1s (2) Pump assembly sat at extend Beyond the ed of he base (2) Contac mance fr atonal spe require for estoy Bseptes 1) Basalt dimension 4, HB, Handi ae maim dimensions Any dimension vf th minum aes ted fac U0 Se pm 3 This eatenced length mension He 2 masimam ae, Wheneve he pump tobe mauled has Fe eaten F the asepae ot HBemus be sed (5) Dhar ange may have apo bal ales (6) SetinFange my have ppd Bot hls o Table 3-2M_ Baseplate Dimensions for Canned Motor Pumps Se ‘aprons Equal imenon mie Socio x Dacage x a Dimension Naminl impel ln. HA Mae. MB AaB, Noe he Mae, a, Delton ameter ate} _Naes GNC) etes (Cotes GH] Eat Oar CO} Maa. HAL HO BC Wot (31 Ge sox a 1 fis da) Gate tty dat at aie BA Nat for am Ba 1) fis ar asthe ts dat ta aie tne 8 Nate sox xm 457 10s iS marae two sts at tod ate ane 305. Sox axa Gr Sn in iio 33 sk to tsi dat asa Ste at Bao te] SOD 80 SPD don bsp ep ah 9s) dope) asa tak eo hae 3 fox oxi 590 don Bis tena dep dope Ba a 3a0 ate 0} 80 100390558 do 3s fea tee ope Ba ta ae 390 Mes 0} Boo SOD SD aon fia iG ihe ian dea des he 2o00 hates a} 250 x 200390559 wo ao pie 4a aang aaa asa nes an ‘ios(sete(} soe 100 300 SPD don dit tat tae Taka Tes 3 ‘ito(seter (6 00% 90 300 SPD jon die tat toes Ti) dak tes ‘izo [aster 10] 0% 300 ao SFO jen dis MM toni dba 368 aos [date] SO 190499559 aon 2ieh aap ta 6S HB So hate] Row sooo Sao don din tym ia aes hn Rizo nate] o Joo oD So dena dish Mtoe ini 368 (6) Pump stems at exind Beyond the ed of he seat (2 Conc mance fr aston! pee require fore toning Bases 1) Basel dimensions 8, HB, Handi ae maim dimension Any dimension vt th minum aes ted aca (6 Se pon 3, Ts etende eth nersion Ht maximum ae Whenever the pump Tobe ue as Fe eter; the bate fo Ae must be ed (5) Drchrge fange may have apn bal le (6, Sutin rane may have ppd Bot hes ASTM A276, Standard Specification for Stainless Stel ‘ars and Shapes ASTM_A312/A312M, Standaed Specification for ‘Seamless and Welded Austenite Staines Stel Pipes ASTM A395/ A395M, Standard Specification for Ferric ‘Ductile lon Pressure Retaining Castings for Use at Elevated Temperatres ASTM AMS, Standard Specification fo Ste! Bars, Hot ‘Wrought or Cold Finished, Quenched and Tempered ASTM A479/A479M, Standaed Specification for ‘Stainless Ste! Bars and Shapes for Use in Boers and (Other Presure Ves ASTM AWD4/ AN94M, Standaed Specification for Castings, Nickel and Nick! Alloy ASTM ASI9, Standard Specification for Seamless Carbon ar Alloy Stee! Mechanical Tabing, ASTM AS36, Standard Specification for Ductile Irn Castings ASTM A7#3/A743M, Standaed Specification for Castings, Ion-Cheomium, Iron-Chromian-Nickel, CContosion Resistant, for General Application ASTM A7H4/ATAIM, Standaed Specification for Castings, fron-Chromium-Nickel, Corrosion Resistant for Severe Service ASTM. AS80/ AS90M, Standard Specification for Castings, 1ron-Chromium-Nickel-Molybdenum Corrosion Resistant, Duplex (Austenitc/ Feri) for General Application ASTM A995/A995M, Standard Specification for Castings, Austenitic eric (Duplex) Stainless Stel, for Pressure-Contaning Patt ASTM B16, Specification for Nickel Ro and Bar [ASTM Bl64, Speciation for Nickel-Copper Red, Bar ‘nd Wire ASTM 335, Specification for Nickel-Molybdenum ‘Alloy Rod ASTM 8348, Specification for Tanium and Titanium ‘Alloy Bars and Billets ASTM 8367, Specification for Titanium and Titans ‘Alloy Castings ASTM BAS, Standard Specification for UNS NO8O20, ‘UNS NO8024, and UNS NOSO26 Nickel Alloy Bar and Wire ASTM D574, Specification for Low-Carbon Nickel — ‘Alloy Rod ASTM B75, Specification for Low ‘Alloy Pate, Sheet, and Stip Publisher: ASTM Intemational, 100 Bare Harbor Drive, 'PO. Box C700, West Conshohocken, PA T9428-2959, (orwweasem or) AWS B1.11, Guide forthe Visual Examination of Welds Publisher: American Welding Soiety (AWS), 8669 NW '36SteeSuite# 130, Mian, FL 33166 (wwwaws.o) IEEE 117, Standard Test Procedure for Evaluation of Systeme of Insulating Materials for Random-Wound ‘AC Electric Machinery ‘Carbon Nickel — Publisher: Institute of Electrical and Electronics Engineer, lnc. (IEEE) 145 Hoes Lane, Piscataway, NJ (8854 (wewieee.o) 150 281, Rolling Bearings — Dynamic oad ratings and rating He ISO 1940-1, Mechanica vibration ~ Balance quality Teatencnt or oor in» constant (ig) Sate Part 1 Specification and verification of balance tolerances Publisher: International Organization for ‘standordaton (SO) Cental Secretariat Chemin de Baronet Case posal 4, 1214 Vern, Gene 2p, Switerand Suse (ero [MSS SP-55, Quality Standard for Stee! Castings for Valves, Fanges and Filings and Other Piping ‘Components — Visual Method for Evaluation of Surface Irregularities Pblisher: Manufacturers Standardization Society of the Valve and Fittings Industry, Ine. (MSS), 127 Park ‘Steet, NE, Vienna, VA 2180 (wwwmss-hqarg) 3 ALTERNATIVE DESIGNS. 3.4 Extended Length Pump Design Aan extended length pump design is an option for enhanced mechanical performance. Dimensions for an fextended length pump design are included in this Standard. Theextended length altemativesallconform to the design features of this specification including those providing interchangeabilty with respect to mounting dimensions at dhe casing, size, and lation ofthe suction and discharge nozzles (ee column heads twithee slic in Tables 1-1 and T-IM through 3-2 and 32M for dimensional limits). 3.2 Close Coupled Design Close coupled magnetic drive pumps have been allowed as an alternative design. The close coupled ‘rrangement shall conform to the design features ofthis Standard including those providing interchangeabilty with respect to mounting dimensoneat the casing size, ‘nd location ofthe suction and discharge novres except there is no requirement for a separate pump bearing frame, Dimensions for close coupled pump baseplates fre nel inthis Stands 3.3 Altemative Design Otheralternative designs willbe considered provided they meet the intent ofthis Standard and cover construc tion characteristics which ae equivalent to and other- Wise in accordance with these specifications. All Geviatons from these specications shall be described fn detail “4 NOMENCLATURE AND DEFINITIONS. ‘AA Definitions of Terms. All nomenclature and definitions of pump compo ‘ents shall be in aeordance with ANSI/HI 3. trough ANSI/HI 5. ‘med motor pup (CMP):a type of sealess pump where the impeller Ss mounted on the end ofthe sha that ‘vering from its motor bearing support, The impeller is mounted directly on the rotor assembly, making one rotor assembly. The bearings are supported by housings steachend of therotorassembly- The motor components fare protected fom the proces quid by corosion ess- tant, nonmagnetic liners (shell). During operation the ‘motor section and bearings av either cooled and lubr ‘ited by the process liguid or # ash intrdaced From fan extemal source, close coupled magnetic drive pune a sealless magnetic ‘rive pump as defined below excep the outer magaet Fing is mounted on the driver shat Inagnetic dive pungp (MDP: a type of seals pump ‘where the impeller is mounted ona ator assembly that Contains the sinner magnet ring of & magnetic drive ‘The proces fluid is retained By a corrosion resistant containment shell that separates the inner mage ring and the outer magnet ring. The outer magnet ring is mounted on the shaft ofa frame that is coupled to a ‘motor or power device plastic ined seals pump: a type of sealless magnetic ‘rive pump which consists ofa metal outer casing cov ‘red internally by aplastic ining for chemical existance ‘Themetal outer casing gives structural rigity for pres- sure containment and externally applied nozzle loads ‘The containment shell ay consist ofa veinforced outer shel eth aplastic insert for chemical resistance, an engineered ceramic or other nonmaliccastruction, All onpressure-containing wetted pats ae ether cov- ‘red bya plastic lining or may be made of an engineered partly coupled magnetic drive pump a sells magnetic dive pump as defined above where the oster mage ring ismounted on the shat ofa frame thats separately ‘coupled! toa motor or power device andl mounted on 3 ‘common baseplate ‘42 Additonal Definitions uailiry piping: includes all piping connected tothe pump excading themain piping connected the pump Suction and discharge lange. Aunlary piping includes piping, tubing, an allalached components such as ‘alvs,istrumentation, and coolers sonpressueconlaning noaeted prt: pump parts tat loot contain or retain pressure and are not wetted by the pumped uid, onpressurecontinng weed parts: pump parts that do fot contain or retan pressure, bul are weed By the pumped fi (eg, wea rng), pressure comtaing nonsetted parts: pump parts that con- fain pressure but are not wetted by the Pumped fad (ega ined casing, cover. pressure containing meted prt: pump parts that contain pressure and are wetted by the pumped fluid (e.g, sing). pressure retin not parts pump parts that retain pressure but ave not welled by the pumped fuld (es, apes, fastener) supplier: manufacturer or manufacturer's representative that supplies the equipment. '5 DESIGN AND CONSTRUCTION FEATURES. 5.4 Pressure and Temperature Limits 5.4.4 Pressure Limits. Pressure limitations shall be stated by the pump manufacturer. See para. 511 for fusilary piping SAL ‘Thedesign pressure ofthe casing casing cover, containment shel, and secondary containment It pplicable, shall be at least as great a6 the pressure Temperature rating of ASME B165 Cass 150 flanges or ASME Bib? Class 150 fanges for the materal used 5.1.1.4 For plastic lined seals pumps, the pressure limitation forte material of constraction of the asng, casing cover, containment shel, and secondary containment, f applicable shall have 3 desig pres atleast equal to the pressure-temperature rating of ‘ASME Blbs12 Class 150 fans. Pumps may be offered ‘with higher design pressures than the minimum stated pressure, Pumps having lower design pressures than {he minimum stated require approval by the purchaser. 5.1.4.2 The design pressure of ackets shall beat feast 100 psig (68% kPa page) at MO" (171°C). Heating [aekets may Be required fo jacket temperatures 300 (Qs0"C) with a reduction in pressure comesponding the reduction in yield strength ofthe jacket materi 5.143 Thecasing casingcover andeontainment shel and secondary presurecontaining boundary and [neket if applicable) shall be designed to withstand a Fnydrotatic test at 15 times the maim design pres ste for the particular component and material of con- struction used (se par. 63.11) 5.1.1.4 All primary pressure-containing parts shall be capable of resisting a vacuum of 14.7 pst (260 men HG) a 68° (21°C) 5.1.2 Temperature Liits. Temperature imitations shall be as stated bythe pump manufacturer including temperature limitations of the liguid a the suction flange: Pumps should be available for temperatures up 19 500 28°C Jacketing and other mandiatons may be required to meet the operating temperature. See pra 8.11 for auilary piping The application ofthe pump shall ake into consider- ation the fluid characterises as supplied by the ust This will require consideration of such characteristics as pectic heat and vapor pressure ofthe liquid which ‘establishes these limits 5.121 Pasi lined sealsss pumps should be dlesignated fora minimum temperature range of -20°F Wo 250F (29°C w 1210). 5.2 Flanges 5.21 General. Section and discharge nozzles shall ‘be Hanged. Flange ili, facing, and mise ick ness shall conform to ASME B16.5 Class 150 oF [ASME Bi62 Clas 150 standards, except that marking requirements are not applicable and the maximum ‘cceplable tolerance on parallelism ofthe back of the flange shall be 3 deg, Flanges shall be flat-faced atthe ful alsed-fae thickness (nimum) called for in the [ASME standards for the material of construction Ralsedface flanges may be offered as an option. Bolt holes shall stradle the horizontal and vertical center: line. Bot holes maybe tapped when adequate space for nuts is not available Behind flanges, a4 noted in “ables 1-1, 1M 31, 1M, 32, and 32M. Through bolt holes are preferred. When tapped holes are supplied, they shal be acted on the ouline deawing 5.2.1.1 For plastic lined sealless pumps, the requirements under para, 52.1 apply excep hat aise face flanges shall be standard. The rslsed-ace portion ‘ofthe flange is formed by the plastic lining 5.2.2 Class 300 Option. As an option, Class 300 anges in secordance wth ASME B16 307 ASME B162 may be offered with pressure ratings subject othe man- Ufacturer’s casing presure-temperature limitations, ‘Class 300 flanges shall be flatoced at fll aised-face thickness (minimum), or raised-face flanges may be ‘offer as an option 5.22.1 Class300flangesare nota required option for plastic ined salless pumps. 5.2.3 X and ¥ Dimensions. All pumps, regardless ‘offing rating shalleonform othe Nand Y dimensions Shown in Tables ol and 3-1 5.24 HeavyHexMuts. Where heneyhexnutscannot bbe used, the location shall be noted on the outline raving NOTE ASME MS and ASME BI682 nde he we of Rey Nets for eran flange conto, Gn many 8 pumps, any hex mls cet ta de to sabe space. Sand ent av fen aust. The we sand he ts my ot low the ae al at sey hich may pt ‘ete gts ity pope a Howe had ics whore afar pad may besegute osc nl Erte 53 Casing 5.3.1 Drain Connection Bosses). The pump casing shall have boss) to provide for drain camection(s) it the lowest part ofthe easing. Boss size shall accommo- late sn, NPT minis. Bos(es) shall be drilled and tapped wen spectiod by the purchaser. 53.1 For plastic lined sealless pumps, a deain shall be provided unless otherwise specied. The drain Shall be atthe lowest part of the pump easing, When ‘provided, the drain shall be sealed. by 9 lind flange fd gasket Screwed connections in plastic ined pumps sre prohibited. 5.32 Auilary Connection Bosses). ‘The suction and discharge novzle shall have bosses) for gage com> ‘eetions. Bos size shall accommodate in. NPT mini- ‘mum, in. NPT preferred. Boss) shal edie and tapped wien specified by the purchaser. 53.21 For plastic lined sealless pumps, suction and discharge gage connections ae nat required, 5.33 Support. The casing shall be supported by {eet beneath the casing ora sultable support between the casing and baseplate. For CMP, an alternative pump cradle between the sator and baseplate Is acceptable 5.3.4 Disassembly. ‘The design shall permit back removal ofthe rotating element) from the easing with ‘ut disturbing the suction and dischange connections. ‘The design shall also avid disturbing the motor on separately coupled MDP pumps. Tapped holes for ack ‘Scewsorequialent mean shallbe provided to facilitate the safe dnassembly and ransembly of he rotating ele ments) from the easing and to avoid the necesty of live wedges or prying implements. Jacksres shall rot cause damage to parts that will interfere with Tesssembly and sealing when the parts are eeused 5.3.5 Heating or Cooling 535.1 There are several methods of cooling of eating ares of most ASME B73-3 magnetic drive and canned motor pumps. The pump casing, bearing hous Jing, and motor are areas that may have design features available for heating of cooling. Commonly used ‘cooling heating piping plans applied to ASME B7333 pump applications are identified n Fig, 31-1. Other onfigrations may be use specifed and agreed upon between the supplier and purchaser 5352 smotoe and/or tions shall be Jackets fr eating o cooing the casing, orp component ate optional Coe iin. NPT minimum, with Is in. NPT avers nest oxchanoee } & Om Bloevatve H a a @eee inet nd hea xchonger Pion preferred. When a jacket is to be used with steam, the Inlet connection shall be locted al the top quadrant of the jacket, anc the drain connection shal be located at the bottom portion ofthe acket to preven the formation ‘of water pockets. Jackets for liquid cooling oF heating Shall have the outiet at the top and inlet atthe bottom te prevent the formation of vapor pockets and drain atthe bottom for freeze protection. 5.3.5.3 Heating or cooling jackets are not a required option for plastic lined seaess pumps. 5.3.6 Gaskets. All assembly gaskets shall be con- fined on the atmospheric side to prevent blowout Design shall cansider thermal cling which may occur as 3 condition of service, Gaskets shall be selected $0 the mule seating stress fs compatible with the aval able bolt load (strength and area). The gasket material Shall be suitable fr the service conditions and flange facing nish 5.3.7 Boling. ‘The pressure-contaning fasteners {incudingcasing, containment shell and secondary con- lainment or contel components if applicable) shall be lesiged to acount for maxinsum alloveable working presure (MAWYP) and be capable of maintaining a sal ‘nthe asket daring operation. The fastener shall have «8 suticint bolt area to assure thatthe resulting tensile Slresses during design loading does not exceed the sllowabe bolt stresses given in ASME Seton I, Part D (able 3). In addition, the tapped holes for presure- retaining bolting shall be of suticlent dept hat dread engagements times the nominal bot diameter When there are sufficient strength differences between the ‘material ofthe tapped hole andthe fastener, he design ‘hall consider posible shearing of Ue threads oF the tapped connection 5.4 Impeller 5.4.1 Types. Impellers of open, semi-open, and closed designs are optional 5.4.2 Balance. Impellers shall meet ISO 1940-1, Grade G63 after final machining. 5.43 Altachment. For MDP rotting shat designs, the impeller shal be keyed threaded, or otherwise por ‘mancaly fixed to the shaft. Thaeads shall be designed to tighten by correct rotation. For CMP rotting shaft tain all iguid released rough the primary pressure containment. No leakage i permite through the sc> ‘ondary structure. This method i called Secondary Containment The material of constrction of the secondary pressire boundary must be ofa ductile matenaland evaluated for corrosion resistance when specifying either Secondary Control or Secondary Containment. The manufacturer shall specify materials of construction forthe secondary ‘containment or secondary control pressure boundary. In the event ofeakage through the primary presse containment, for ether ofthe metheds above, operation ‘ofthe pump shall be immediately discontinue. “The purchaser salle responsible for providing shut down devices and procedures required fr safety. When specified, one ofthe following designs to con ‘eo any leakage from the containment sell the liner ofthe primary pressure containment shall be proved by the manufacturer, 5.63.1. Secondary Contol (a) Any leakage through the primary containment sll be minimized and safely diced by a Boundary rmade up of devices, including a secondary pressure ‘sing capable of maximum design pressure (b)Thesecondary control halle drainable to ares val ofa maximum of2 in? (0 mi) or toa value agreed ‘upon By the user and the manufacturer, 16) Thesacondary contol shal proved with fash and drain connections. 5.63.2 Secondary Containment (a) Any leakage through the primary containment shall becontained by secondary ctainment atthe may mum allowable working pressure for 8 mismun of she (&) The secondary containment shall be desinable to ‘rsidual of maximum of 2 in? (20 on) ot toa vale ‘agreed upon by the user and the manufacturee (e) Thesccondary containment shall be provided with fush and drain connections when specified, 5.63.21 Secondary Contalament Verification. When specified, a means for periodically checking the secondary containment, fr sealing capability shall be provide by the manufacturer 5.646 Draining. All pumped fuic-containing ares, including vendor-supplied piping shall be drainable to a vesdual of maximum of 2 in” (30m, oF toa value ‘agreed upon by the manuactirer and porchaser, and ‘hal be suitable for fusing before disasembiy rng Frame (MDP) 5.7 Bearings, Lubrication, and 5:74 Esteral Bearings 5.7.1.1 Beating Design. Two rollingclement boa ing assemblies shall be provided: ane assembly fee to Fat within the bearing frame bo cary radial loading, ‘only, and the other assembly fixed or located axial. 5.74.2 Beating ie. Bearings shall be selected in accordance with ANSI/ABMA9, ANSI/ ABMA-I1, and 150251. The minimum Lobearing life shall be 17,500 he forall standard and optional bearing ame arrange- ments of beatings, lubrication, shalt, covers, and sling. 5.74.24 For close coupled MDP, the suppli shal be responsible for assuring the motor bearing life ‘when ealeulated in accordance with ANSI/ABMAS, |ANSI/ABMA-TI, and IS0 281 wil provide a mininnam {ip bearing life of 17.500 he. 5.7413 Lubrication 5.73.1 Oil bath lobrictin is standard on separately coupled MDP. 34.1 For ose coupled MDP, greased lubrication shal be standare. When rereaseable Iubr- cation is specified, means for grease velit shall be provide. 5.74.32 Oil mst lubrication shall be optional When ol mist Iabrication i specified, the lation of the inlets, drains, and the vents should be mutually ‘greed upon between the purchtser and the supple: 5743.3 Greased for ie or repreaseable bri ‘ation shal be optional on separately coupled’ MDP. When mreaseable lubrication spect, a means fr grease rele shal be provide. 5.72 Beating Frame. Beating frame shall be con- structed to protect the bearings fom water, dist, and ‘other contaminants and provide tbrlation or the beat= ings The standard design is fo ol bath sbrication and Js to Include Ibyrinth-type bearing isolators, a1 in (25 ma) bullseye ol sight glass, magnetic drain plug, and plugged top vent. 5.7.21 Sealing. Thestandard designs wo include Inbyrinttype bearing isolators. In adlition, optional dlsigns may be offered thatallow forthe use oa variety ‘of other bearing fame seals, sacha lip seals or magnetic ‘i seals as may be specified by the purchaser, In those ‘ise where the bearing frame seal doesnot allow The bearing frame pressure to equalize with atmospheric pressure during operation, an expansion chamber or breather is necessary 5.7.22 Bearing Frame Drain. fearing fame shall be provided with a tapped and plugged dain Roe at its lowest point. A magnetic drain plug shall be used 5.7.23 Lubricant Level Indication. Bearing fame for il bath lubrication shal be provided with a Tin {25 mum) bullseye level indicator that i capable of ‘optionally being installed on ether sie or oth sides fof the bearing frame. The proper oil level for the ‘hon-operating pump shall be indicted on the outside ofthe bearing frame, 5.7.2.4 Constant Level Oller. constatlevel lee ‘snot part ofthe standard design but may be included ‘saan option when specified. Ifa constant level ler is ‘Supplied it shall be set initally by the supplir for the proper level during operation, 5.8 Outer Magnet Assembly (MOP) 58. Mounting, Te outer magnet assembly shall be positively driven and runout shall Be limite to pre= vent contact with stationary components during nom ‘operation, Connections shall no losen ding reverse 5.82 Containment Shell Protection. The pump shall be designed to delay the outer magnet ring from con- {acting the containment shall in the event of shaft or bearing failure. When specified, the design shall uilize ‘device of non-sparking material to minimize any Source of ignition ‘58.3 Comosion Resistance, The surfaces of ferrous materials ofthe otter carte, frame, and magnet shall have a heat resistant paint or coating Yo protect these secs from corrosion. 5.8.4 Balance. The outer magnet assembly shall be bolanced 10 a minimum ISO 1941, Gade G63, 5.85 Citeal Speed. Theft lateral rtcal speed ofthe rotating assembly shal be atleast 120% of the ‘axenum operating spot 5.8.6 Fillets and Radl,Allshaft shoulder fillets and tai shall be as lange os practical and finshed to educe ditional stress ser 59 Stator Assembly (CMP) 5.9.4 Stator Windings. The stator windings shall bbe protected By a corroion-esstant liner suitable for the specified conditions. 5.9.2 Filed Stators. For illedstators the secondary containment components of the stator assembly shall meet the requirements of para, 5632, Supplier shall provide the user withthe Material Saety Data Sheet {MSDS} of the filling medium in the stator assembly. “The user must confi thal the stator ling med fs compatibie withthe proces fluid in the event of a ric mary containment fale 5.93 Temperature Rating. Motor stator windings shallbe designed to operate at or below the temperature ‘values established forthe grade of isulation in actor= dance with IEEE 117. Maximum flv temperatore, motor winding temperature ie due to motor inet ‘eney est np ofthe proces fu lingo the stator ‘avty with aheatconductive medium, pump fuld er Inton pln, andauiiary cooling shal al be consid cred in determining the maximum motor winding temperature forthe application 5.9.4 Motor Design Life. Motorsizing stato ins tion rating, cooling uid temperature and fw, theemal isolation, and use of jackets or heat exchangers shall be designed and selected to provide a minimum of 175000 ar design life at specified operating conditions, 59.5 Thermal Protection, Thermal protection shall ‘be provided: The manufacturer shall ads he temper turesetting and supply the applicable wiring diagrams When specified, lower temperate setting thermal pro tection shal be provided. 5.96 Hazardous Locations. Motors electrical com- ‘ponents, and electrical installations sal be suitable for the area electrical cassfiation (Cas, Group, Division, and T Code), aswell as national and local codes a Spected by the purchaser 5.10 Materials of Construction 540 Generat 540.14 Theidentifving materia of ‘be that of which the easing fs constructed vp stall 5.10.2 The pump material classification code in Table 5.10.21 shall be used to specify the pump raters of constraction for metalic MDP and CMP. 5.40.2 For plastic lined MDP, the pump material classification cade in Table 5.10.1.2-1 with Tse Code MDP-X shall be used to specty the pump metalic nonmetallic, and plastic materials of construc- tio forthe casing impellt cover pump shat contain rent shell, and secondary containment/ contol (i foxished), Liste below arecommon polymer materials ‘sed in plastic lined MDP (a) plsttrefluooeylene (PTFE): neatly wniversl chemical resistance witha temperature lit of 330° wre (by perfluroatory (PFA): nearly universal chemical resiatance with temperature int of 390% (177°C), (0 ethylene tetrafuoroethylene (ETFE) very good chemical resistance witha temperature lit of 28°F (are) (a) polycinyidin fluoride (PVDF): good chemical resistance with a temperate imi of 250° (21°C) 5.0.3 The pump part materials shall be in accordance with the Specific ASTM material specifica tions in Table 10.134 for each of the sted materat designations 510.14 Other matevats shall be agreed upon by the purchaser and the supple. 5.10.1.5 No repair by plugging, peening, of Simpregnaton is allowed on any parts wetted by the pumped fd. 5.11 Auslary Piping 5.11.1 Auxllary piping shall, as a minimum, be wailale with the materials of constriction in accor ‘ance with Table 111+ 5.11.2 Auxiliary piping in contact with the ‘pumped id shal have a pressure /temperature rating ‘qual to, or greater than dhe maximum allowable wos ing pressure (MAW) of the pump. Auxiliary piping ‘which may become exposed to pumped Muid in the tvent ofa file shall meet this reirement 5.11.3 _Auxilay piping and components normally in contact withthe pumped fuid shall havea corrosion resistance to the pumped! Muid that is equal to, or better than that ofthe easing 5.12 Corrosion Allowance All wetted components ofthe pump shall be made of materials that are corosion resistant fo the ids being [pumped at the maxinunt rated proces temperate For cortosve fluid, the wetted components shall be ‘greed upon between the purchaser and supplier by ‘onsieration of corosion rates for fds, process tm peratures, and material, 5.13 Direction of Rotation Direction of rotation shall be clockwise when viewed from the motor end ofthe pump. An arrow showing the direction of tation shall be provided ether cast om {he casing or stamped ona plate of durable construction afsed #0 the pomp ina prominent location Table Magnetic Drive ‘MOP. = Magra Be Fam; CP Canned Motor Pum ma no Te Mater Classification Codes ave Coe Sessa ss oe or Cre OM or ening Housngs CM) 3S dtess—iloy30—=—cOn en_—Alny Care Aspe ny Sa jonss he ss_———loys0_—Gupenzn0s—lopeare Arps Crone sel MOP ony se Sar_—teSSor_—Aloyeavgor Alcove AlayCare spec tetra tne and cesher ates” at ehve Alay C7 Alay C76 Arpad cod cos CP ony hes iy 20 SSoniyconsimenfonl A spected _Asspeied__Asapeed At speed As spedied Aa speed Fis Sufi — Produc abit eng Sten stng/oc. Ths en) Poa wate aon wap seis ‘aon gape oone ‘se speaed “asters NOP oy ropa coating . “nal esenes ‘acropsymercaing irrumes Cosine ott Nam ber_Wolieg PTE Pesbewaphte Vion Ong PRE encapsulated As speed Fou Sui = ier Weed ase wa rotnene a 1 ° v w x_n et ‘rer ne i Sie — bie Nagrte x 3 (a) Asn example, the pump meter csieatn cede MOP S16S58SSAF'S nates he toning or 4 magne de pm (casing = S058 O) inpeer = 6 85 com = 3655 {6 pump aun = 33655, {5 ortnman shel Ay C276 {6 Secondary conanenanl = 2 speci 1) product vated being seem = SC (0 cas steers = 30035 1655 {5 contoman shel fasteners = 04 55 0365 {oy seconds crane oF ot ates aise) = 306 5 0036 55 {1} sangeet = om fer {1} oter eed gas = Yann {13 ve magnets = sonar abt th Avan xaml the pump ml sian code CMP S16SSCS-AFW nates the flowing fo {casing = 058 O) inp = 1685 () Searing housings = 38655 {6 pump nn = S36 55 {5 ttre, sr ine, mtr ed ovr = 316 55 {0 Secondary conaiomenonol = 2 spectied (roduc uated beg Stem = cron phere {casing asters = 304350 31655 (9 sacanday conaomet or con sees amined) = 206 55 oF 396 5, {ty casa gstet = som fet” {1) ter meted gases = a0 (For MOR, asin and consnmen shel pte he ame sec WI B ® Table 5.10.1.5-1 ASTM Material Specifications resus Conining Rressereetinng a Caigs Were ——‘opressr etaing snderhoneeted by CntngsNometed reste ting Bats ati esgstin ope a Pumped Fuld a Sock nd Ste sts ‘tog 2 elles et ‘oy 62 toy co tog C76 1995 rade 18 COANCAN) rae Gade CPM oe ‘hep eade cP veo) 276 pe 3t6 Trpotme ose urate ating Table 5.11.4-1 Minimum Requirements for Auxillary Piping Materials 7 peas seist ‘Savings Yan, 00.107 om © _Woeftngs __pe_— gue suet breraion __Mmum val hanes 035 Compression ype ‘Senile Win, Cas 2000 in Caron et 3519 rome 708 ‘ios cnce® Atos \eeamien) 5.16 Dimensions Pump dimensions shall conform to Table I-Land 11M (or and 31M, Beseplate dimensions shall conform to Tables 12, 12M, 2:1,2-1M, or 32 and 32M, 5.15 Miscellaneous Design Features 5.A5A Safety Guards. Each coupling shall be fur- ished with coupling gua The coupling gust shall prevent percnnl frm contacting rotating components. Regional regulations and purchaser requtements may require additional guards All guards shall meet the petformance citeria of ANSI BIL 18, 5.51.4 Safety guards are not applicable toclose ‘coupled MDP oe CMI 5.15.2 Threads. All threaded parts, such as bolts, ‘nuts, and plugs, shall conform t0 ASME standards Unlese otherwise speciied, 5.15.3 Ling Rings (MDP). A iting ving or other ‘equivalent device shalbe provided to facitatehandling the frame and associated assembly If ts mass exceeds 60 1b Q7 kg). For magpie drive pumps on beiplates, feyebolts on motors and/or pumps are not suitable for iting the entire pump and motor assembly. The pump manufacturers manual shall provide iting Instructions. 5.15.4 Tapped Openings. All tapped openings ‘which maybe expose to the pumped lid under pre Sure (including the secondary containment where fur ished) shall be plage with threaded metal plays Plage normally in contact with the pumped tui shal be of the same material a the cae, excopt thal eavbon steel pigemay be secon ductile ron pumps. Threaded plugs shall not be used inthe heating or cooling jackat Piping connections; nstead nape plugsor waterproof Tape shal bused to reieve posible pressure accumu ion nti piping instal 5.5.5 Venting. The entire unit including casing live section, and piping supplied by the manutacturet ‘shallbe selventing or fumished with vent connections 5.15.6 Mentficatio, The manufacturers part iden- ‘ication numbers material designation shal bcast, clearly die stamped, oF etched on the casing, cover, {mpeller a containment shel The manufacturers shall provide Wentfcation on the product lbriatedbeat~ {ngs (aging is seceptable) to asst in parts identifica tion prior to assembly. 5.15.7 Installation. All equipment proves sh be designed for unsheltred gutter installation and ‘operation al speed ambent temperatures, 5.5. Frame (MDP). ‘The frame shall be designed Aomsista torque a eats high asthe decoupling torque ‘Strength ofthe langest drive magnets availabe for that frame “The frome, when itclamps the rae cover plate to the pump casing, would be classified asa pressute-retaining part and shall be made of a sultable ductile material Sich a cast ductile ron or east earbon ste. When the bearing fame is specified for secondary control or see- ‘ondary containment i shall be constrcted of 3 dtc ‘material 5.15.9 Baseplates. Basplats shal be designed in accordance with ANSI/HI3, which includes grouted, ‘ungrouted,pregrouted, and resting baseplstes 5.59.1 Baseplate Options. If specie, the fo lossng baseplate options shall be available (a) fabricated steel construction with continuous welding (no ship es) {b) pumpand motor mounting surfaces machined at snd parallel within 0.02 in. /# (0.17 mm/m) (0) fll dain rim with surface sloped to minimum 1 in. NPT drain connection to lle complete drainage (a) motor alignment adjusters (0) devices to allow lifting of complete unt (pump, motor baseplate, and atached aula) 5:15.9:2 Baseplate Rigidity MDP). Dosepats, for separately coupled pumps wich are to be freestanding (Goot oe spring supported rather than held by anchor bolts an grotted) shall be so stuctraly rigid as to Tint movement ofthe diver shaft lative to Ue purmp driveshaft o 0002 in, (005 mm) paral offset when the driver forge of nameplate horepovser is appli 5.15.9.24 Freestanding foot-mounted ‘aseplates shall meet the load and deflection rts of ANSI/HI 9.62, pata, 962.1.7.11 5.15,9.2.2 Freestanding spring-mounted ‘baeplates shall meet the tess and rigidly requlte- ments of ANSI/H 13, para. 1384 allowable nozzle loads shall be mutually agreed upon between the sup per and prchaser 5.16 Monitoring Devices 5.16.1 Description. Devices or instruments that indicate or control the canton of the saless pump to preclude misoperation or damage tothe unit shoul be availabe when specified 5.16.2 Temperature Probe. Sensing of temperature ‘ofthe recirculation Maid and/or the containment shell ‘Should be available when specified. Location of temp fsture sensors shall be agreed upon between the pute ‘haver and manutactore 5.1621 Sensing of temperate ofthe recrcul tion Mui and or the containment shll for plastic ined MDP is not a muir option 5.63 Bearing Wear Detector (CMP). A device to ‘detect axial and adil wear fr a minimum of one beat= ing should be avalable when specified 5.164 Vibration. When vibration transducers ae specified they mst be mounted in such a wa’ 38 not adversely affect the accuracy f the measurements. ‘Acceptable mounting methods for permanent iid mount or temporary mount transducers shall be in Accordance with ANSI/HI 9.54. MDP bearing housing measurement locations and directions for separately ‘coupled type OFT (ASME B73.) pumps and close cour pled type OH7 pumps shall be in accordance with [ANSI/HI 9.64, Fig. 9.64.2.3.1. For CMP type OH pumps, the location shall be on the motor endl cavern the horizontal, vertical and aval positions as shown in Fig S164 5.65 Motor. A device that monitors the motor should be avallable when specified, This device may ‘detect one oF more ofthe following (@) power (0) pase imbatance (6) under curent (4) overcurrent ) single phasing, (P short circuit o intemal malfunction 5.166 Clrulation Flu. A device t9 monitor the flow rate ofthe circulation fluid should be avallable when specified. This requirement will only apply #0 pumps with exteral circulation and does not apply to Internal created pumps 5.16.7 Direction of Rotation Indicator (CMP). A ircton of rotation indicator shouldbe available when specified. 5.168 Leak Detection. 4 device to detect enkage from the prinary containment line fe CMP or cont ‘ment shell for MDP shall be available when specifi 6. GENERAL INFORMATION 6.1 Application Application of selless pumps requires more consider- ation than that for conventional ential pumps is ‘ecommended that anyone applying this type of equlp- sent read pars. 5.3, Design and Application, of AANSI/HIS.L through 56. {6.141 Terminology. Terminology shall be in accor dance with ANSI/HI 5. through i and ANSI/HILTS fexcept a8 NPSHR is clarified in para. 617 6.1.2 Nozzle Loading. Allowable nozzle loading Imposed by the piping shall be in accordance with ANSI/HI982, 64.3 Sound. ‘The maximum sound pressure level praaced by the pomp and driver shall comply with the limit specified by the purchaser. Tests, I specified, shall be condicted in accordance with the standards of AANSI/HI9.1/95,Drivernoise data must be determined separately, 6.414 Vibration, The vibration level measured on ‘the pump besrng frame, sehen specified, a the suppi> ers est facility atthe ated condition point (speed 5%, Flow 5%) shall not exceed allowable “factory” pump beating housing vibration limits shown. in AANSI/HI9.64, Fig. 9.642 5a, foe type OH and OHI MDP or type OH CMP unless otherwise agreed upon between ihe supplier and purchaser 6.15 Hydraule Coverage. Tables 615-1 and 6.152 show the appronimate hydraulic coverage for 0 Hz and att, 6.1.6 Operating Region 6.1.6.1 Allowable Operating Region. Pumps shall be designed to operate continuous between 110% of {he flow atthe Best Efency Point and the inion flows shown in Table 61.611 nless specifically noted otherwise by the manufacture, and meet the requ ‘ents of pars. 555 (intemal drive assembly bearings), 5712 (eternal bearing if), and 6.14 (bation) when pomping water at ambient conlitions ‘num thermal low for aspen thereto hep ‘minim operating low my bs higher han show Pp ‘ide heated rt ge though he diesen sass [mp andthe minint theral wstat whee th epee izes enough trough the pump that ers of some Fig. 5.16.1 CMP Vibration Measurement Locations ‘ie flow reduces the vial ne pst sion ea below ‘atesetedby he pomp, rating cavaen vpn ‘tine pumped Maid Reterto ANSI and ANSI 33 for ‘ited sppiation ntormaton 6.1.7 NPSHR. NPSHR is defined as per ANSI/ HI146 except this value fs equal to or greater than INDSHB. Under special citcumstances NSPHR may be Tess than NPSHS if agreed upon between the supplier ‘nd the purchaser 6.1.8 NPSH Margin. An operating NPSH margin is necesary lo ensure satiafactory operation. A minimum margin of3 (09m) ora margin ato ot 12 (whichever ‘Yields 9 higher NPSHI regulrement) should be made {silable. This margin should be increased if variables vist that wil increase the NSH ofthe pump. Refer to ANSI/HI9461foradditional apliation information. 462 Performance Curves Published performance curves in printed or electronic format shall be based on tests conducted in accordance swith ANSI/HI 16, Accuracy ofthe curves shal be that 0% of pumps purchased “untested,” When operated between minimum allowable flow and BEP, will perform to the published curve within the following toecances (a) ead #3%/—5% (0) ettcieney -59% NOTE Hes andticny a fos ter than BEP ny have ‘pater saiton than he lnc wt oe. Published performance curves shall be used for pre liminary sizing only and ae based on water perform: ance. Published performance curves may not include ‘ey current and parasitic loses associated with both (MDP and CMP products, If such information & pub- lished, shall beindieated whether efciency nd power curve values contain these ksses. For CMP and close ‘Coupled MDP i shal be stated whether published ef tency is based on pump efficiency or overalefcency (ire to water) and if curve power is based on pump shalt power or motor input electrical power 63 Tests and inspections 63.1 Tests. Uniess otherwise agree, the supplier shullgivestleast ive working days of advance nti tion ofan observed or witnessed test o inspection. 6.3.1.1 Hydrostatic 631.1.1 Standard Hydrostatic. After machin- ing, all metalic pressure-containing parts or metal tucked plastic ined ports shall be hydronatcally tested for 10 min minimum with water at times the masi> _mum design pressure corresponding to 100°F (35°C) for the mater of eonstraction used. Dailed andl tapped connections added post hydro equiea visual inspection only to asure no voids exist tnd threads ave well formed. ‘Rue fo pestrecontaing farts wetedby the pump a When secondary control or secondary containment specified, the following hydrostatic esting must aso be performed, The secondary containment components, ot In the ese of secondary contol, the secondary presse ‘sing, shall be tested in accordance with para. 365 of 'ANSI/HI5.1 through 36 or pneumatic ested in accor dance with ND.SI12 of the ASME Boiler and Pressure ‘esse Code, Section Il, Division 1 Subsection ND. For MDP, secondary containment control compainents shall Table 6.1.5-1 Approximate Hydraulic Coverage, 50 Hz Se 3450 om 3500 om os See Deg ‘cont aie Goaaiy Deiraton ner a ee ee Domotec) 3 a ao ose Seo nate tn 6 xa aD soto ak one oy 3 xass weet ote Gh 3 Ps Bo ae eat Monee Gh 4 x3 Sook aoe mks ‘EMER OTE: The Stand doesnot cnr ect yee promance of pumps. formation on appa had and apy tthe best fine pl or stand’ pump efor gee itaratn a. Conat massacres aang hale promos fr Spec sppators (3 Lund maybe mote ois onion oF minum npr ameter may Be ined ue 1 ntalns of the pug tr Table 6.1.5-2 Approximate Hydraulic Coverage, 60 Hz ie 50 om 30 om Face Dae 1 ‘Gra Twa une om mh mm Bao nee) so srs] a0 Mowe roo 2 Shae pone gd 3 ese wos 180 wo wm Bonet] 3 Pe So Sots SH] asa Boneh es foo ets auto Boxe x5 200 454200 05 6 xe xi 1900 wo 2506 ‘GOWEAL NOTTS does ot over ent yale promanc of ump. information on appa bend an cacy athe best fee pl or sland pun eo gent iaratin ny. Conak manufac esate Msc ptomsans ht (Liu end may Be mote hi odin or maximum npr ameter may De ied du 1 ntaens the pump tr sient omit 3,500 pe Imvier 39000 Dameter conse 6a aso ne SENERALNOTE: Sepa. 6:16 forcauton eaaingsing aes (Lins tert etal yt peormare, a he ‘eang al performance ao specie be hydosttclly teste for 10 min, minimums with ‘water at 15 times the maximum design pressure comes ponding 10 10°F (°C) for the material of construc- Fon se 6.3.1.1.1.1 For nonmetallic containment shel ineversibie damage may occur to the reinforce- rent of enforced plastic arts that are put under exces ‘ve pressure. Containment shells of reinforced plastic ‘material shall be hydrostatic ested for a mini ‘of 10 min, ith ater at a minimum of 1.1 times the ‘maximum design pressure corresponding to 100°E (68°C) forthe material of construction used [Novisible leakage through the part shallbe permitted. ‘The manufacturer should beable to verify though test record that adequate sampling was done to prove that the parts can sustain 1.3 times the maximum design pressure. When a 1.5 hydrostatic test pressure is eguested, all partis should agree to the consequences of possible reversible damage. 6.3.1.1.2 Assembled Pump Hydrostatic Test, ‘When specie, the assembled pump shal be in econ dance with Appendix B of ANSI/HI 146 63.3.2 Hermetic Integrity Test. When specifi 3 hermetic inte test hal be performed on the pump ‘unitafter final assembly. Prior to testing al liga shall be remove! from ll interal eats, {Tamed seodancewilhpars S430 ANSUMI SH tough 6.3.1.3 Performance 6.3.13.1 Procedure. When performance tests ne equited, they shall be conducted in accordance with ‘ANSI/HI 14.6. When testing arated speed isnot possi- ble, test sport should not be less than Nor more than 120% of tated sped. I testing at other speeds, edly current and parasitic losses can vary significant The purchaser and supplier shall agree on coretions to ‘pump power input prior to testing. If applying MDP or CP to very ow 5G. huis testing at sped les than 80% of rated may be required to avoid decoupling a MDP or overloading the motor on CMP. In sch cases ‘greement must be reached between the purchaser and Supplier pri to testing 6.3.1.3.2 Acceptance Criteria, Performance scceptance grade 1B shall be used for all pump input powers 6.3.1.3. Optional Guarantee Requirement. ANSI/HI T16 performance acceptance grade 1B includes power or efficiency as an optional guarantee requirement. When specie, the acceptance criteria ‘hull include either power o ffcency at rated conde tion pont {63.1.3.4 Vibeation Measurements. When speci- fied, the performance test shall Include vibra Ine siements in accordance with para 6.14 6.3.1.3.5 Retest. If the tested impeller is reuied toe timed less han 5% of eine diame ter due to flue to meet acceptance criteria, a retest ier trimmings not necessary. Trims of greater than 5% requirea retest. Ifa new impellers required, a retest, is required. 6.3.1.3.6 wilten Record. A complete written record ofthe relevant test information including per- formance curves, the date ofthe test, andthe sigaature ofthe person(s) responsible for eanducting the tests shall be delivered as part ofthe pump documentation 6.3.1.3.7 Additional Data. Additional da when specified, may be taken during the performance test These data may inclade such things 86 vibration, bearing housing temperature sump temperature et Unless otherwise specied, the additional data will be taken atthe ated duty point When these data ae spec fied, they shall be conducted in accordance With ANSI/HI IS {63:1.4 Net Positive Suction Head Required (NPSHR) ‘est. When specified, NPSHR tests shal be conducted in accordance with ANSI/HL 146. Unless otherwise ‘greed toby the purchaser and supple, the NPSH test Weill be a Type It test which i for determination oF INDSHS atthe rated low ony 6.3.1.5 Winding Integrity Test for Canned Motor Pumps. The motor tes shallbeconducted inaccordance with para 564 of ANSI/HIS.1 through 5 6.3.2 Inspections 6.3.21 Final Inspection. A final inspection may ‘bespecitied by the purchaser I specified, the purchaser ‘or purchaser's representative wll be given acess ko the completed pump assembly for visual inspection of the sembly prio o shipment. {63.2.2 Dismantle and Inspect After Test. spec fed, the pump shall be disoantled and inspected after test Inspection procedure and itera must be agreed ‘pon by the purchaser and supplier 63.23 Inspection of Connection Welds. When a visual inspection of weld connection specified sal ‘be cndlted in accordance with AWS B11 for evalu on of sizeof wel understand splatter. A complete ‘written record of welder, date of welding, method, and Filler material must be retained 63.24 Inspection of Castings. When inspection ‘of cast parts weted bythe process Mud Is specified, a ‘sual inspection shall be conducted in accordance with IMSS 5P.55 for evaluation af east surfaces Inspection oF the castings by other nondestructive methods such 35 dye penetra weay may be agreed pan between the manufacturer and purchaser, 6.4 Nameplates The mameplates) i to be of 24 US Standard Gauge (einimim) AISI 300 serie stainless stel and shall be securely attached to the pump. The nameplate data is to be Based on rated applicstion conditions 64.1 MDP, The MDP nameplateshal be stamped or embossed to include pump model, standard dimension ‘esignaion, serial number, pump size, magnetic cou- pling torque rating for 100°F (35°C), impeller diameter Installed, maximumallowable impeller damete (oe the intalled magnetic coupling), material of construction, ‘maximum design presure for 100F (38°C), and rated speed 6.42 CMP. The CMP nameplateshall bestamped or embossed to include pump model, standard dimension ‘esignation, sera number impeler diameter nae, ‘maximum impeller diameter based on installed motor ‘Sze material oconstrcton,masimum design pressure for 10°F 68°C), volts, ful lad amps, sped, insulation las, shaft rake horsepower ulead KW, locked oor ‘code, hertz, phase, phase sequence and operating tem perature code 7. DOCUMENTATION 74 General ‘The documentation specified covers the minimum required to provide clear communication between the ‘ump user and pump manufacturer and Wo faiiate the fale design, installation, and operation of the pump. ‘Adeitional dats, a= required for specie porposes, shall tbeavalable, requested, Its the intent thal information be furnished in'a similar form from all sources to Improve catty and foster efficent utilzation of the ocumentation. 72 Requirements ‘The following, dacuments shall be supplied foreach ‘pump item furnish: (a) pump and driver outline drawing (by) centitugal pump data sheet (0) manufacturers oolng/ heating piping drawing it applicable) {a pump fluid creation plan (0) performance cuve with rating point (ferosssectional drawing with parts lst (instruction manual {hy motor wiring diagram (CMP) (0 couplingeutline drawing, partslistand alignment Aolerace lite (documentation foe specified performance est 173 Document Description 7.3. Pump and Driver Outine Drawing (a) The pump and driver ouline drawing may con- tsinall information showin on and may be arrange 3, {the sample outline drawing included herein and ident fied a Figs, 73101 and 7.3.12, ‘sdung s0)0W pauue) 0} Buyeig aumpno Jong pue dung Z-FE'L BU (©) Tapped openings, when supplied, shall be ident fed with the flowing markings TV Containment shell dain (MDP rear bearing Tsing insect (MP) te cavity drain oection (EMP Pre comcton (MP) YI Frame sanecor top (MDP: wing temper "ure connection (CI vat Frameconrtine dn MDP vent esos — id str (CMP 1X Containment all a ne (MDP vation fre (CM) 17.3.2 Sealless Centrifugal Pump Data Sheet (a) Data Sit. Te ASME Sealess Centifugal Pump Data Sheet in Mandatory Appendix I shal be use fo all pumps covered by this Standard when the datasheet is iiite by the purchaser. The data shet electronic ‘orprinted copy, shall be use for inquiry, proposal, and ‘sbull (0) Electric Data See Nonmandatory Appendix A 7.33 Fuld Circulation Piping Orawing (@) The fluid circulation piping drawing shall be included ifthe pump is fitted with a creultion piping, ‘system supplied by the pump manwfacturee, (&) The ud circulation piping drawing shall contain Information ad uniform nomenclature consistent with the sample schematics and references given in pan 3555. 7.34 Cooling/Meatng Piping Drawing (a) & cooling heating piping drawing shall be included if the pump assembly is fitted with 2 heating

You might also like