You are on page 1of 4
OKA PRECAST RC BOX CULVERT ® OKA CONCRETE INDUSTRIES SDN. BHD. (67634-m) =O OKA provides an extensive range of precast reinforced concrete box culverts from nominal width of 300mm to 3660mm, which are further categorized in accordance to the width of culverts as follow: 1. Sta indard Size Box Culvert (width from 300mm to 1800mm) 2. Supersize Box Culvert (width from 2135mm to 3660mm) ‘OkA box culverts are available with and without dry weather flow (DWF) channels. All box culverts are manufactured under controlled factory environment with stringent ISO 9001:2008 quality management system. DESIGN CRITERIA > Structural design of OKA box culverts are in accordance to: a) BS5400 : Part 4: 1990 b) BD 31/01 ~The design of buried concrete box and portal frame structures ¢)_Ms1293: Part1: 1992 > OKA box culverts are designed to withstand a standard 2m (max.) of superimposed backtill depth and 45 units of HB vehicle live load OKA standard size hx culverts alsa complied to 119 § KN proof load applied over an area of 320mm x 320mm at any position on the culverts lid. > Minimum backfill depth ot 6UUmm over OKA box culverts are recommended to avoid undesirable direct impact load. > Hydrostatic pressure is relieved by provision of weephole placed along the centerline of the invert wall > Please kindly refer to our marketing personnel tor assistance if special design are required for other loading conditions to suit your project requirements MATERIAL SPECIFICATION > Concrete characteristic strength at 28 days : Grade 30 to Grade 40 > Nominal cover for OKA Standard Size and Supersize Box Culverts are 25mm and 30mm respectively, > Bulk density of backfill soil to be 19 kN/m? > Coefficient of earth pressure at rest = 0.5 > Backfill material adjacent to invert wall should be granular type of soil. Backfilling sequence of even layer at alternate approach side of box culvert must be observed. HANDLING, STACKING, LAYING & JOINTING * Handling: A spreader beam is recommended to be used with steel pins and lifting cables to avoid cracking at junction of side wall and base slab. Box culverts’ invert and lid are to be stacked on level and stable ground or timber bearer to Box culverts are to be laid on layered of well compacted granular materials, a surface blinding of the fine materials will assist leveling. RC capping siab shall be provided if piling is required + Stacking: avoid cracking due to undesired localized load. + Laying: + Jointing with cement-sand mortar. OKA box culverts are supplied in butt joint. Gaps between box culverts are normally filled up {In view of continual impravement OKA reserves the right to aller the Specifications! dimensions without prior notice. MARCH, 2000 OKA STANDARD SIZE BOX CULVERT 110. 110 [_wrthourpayweatHerriow | WITHDRYWEATHERFLOW | 8 ed el [300 xT 300 | 300 | 300 | 65 |" 70 | 140 [ 110 [430 [012 [oie {012 _| 300 450 [<5 | 00 Hise et or Lae | [300 [300 | 600 | 65 [eo [aso | 125 [730 [022 |" 022 | o22 [030 | oie cael ne Peres Pere COPE ane 8 i 10 1200_| 1800 [115 Figs sso io 1800 x 225. 3070 | 180_| 1970 | 180 1500 | 1800 | 115 225 1070 | 180 ae] on 2030) 2030 Fas Cie be oie testi teeta Tie Pee ta] | 1800 _| "1800 | 1800 [115 [225 | 1070" [-120-[-2030-|-0.90 | 1.60 | 050 | 231] (090. In Vigwwot continual improvement OKA reserves the right to ater the Spectications/ dimensions without prior notice, | (MARCH, 2020, OKA SUPER SIZE BOX CULVERT WITHOUT DRY WEATHER FLOW (WITH DRY WEATHER FLOW, B contests t a elie Un sh CU ays a DIMENSIONS (mm) WEIGHT (ton) Nominatsize | h b t [at [w]e] es W/o DWE CNW DWE uo _[ivverr| uo [invert 300 [900 [2135 [aso [25 | tom | aas [2435 [128 [aso [128 [253 soso | i050 | 2135 | iso | 25 | 10m | 21s | 23s | 128 | 170 | 128 | 264 sz00_| 1200 | 2135 [150 | 25 | 10m | 21s | 2435 | 128 | 1a | 128 | 275 x350_| 1350 | 2135 | iso | 25 | om | 215 | 2435 | 128 | 192 | 128 | 286 aoox | 1500 | 1500 | 2135 | 150 | 25 | som | 215 | 2435 | 128 | 203 | 1.28 | 297 1650 | i650 | 2135 [150 | 25 | 10m | 215 | 235 | 128 | 210 | 128 | 3.08 1go0_| 1800 | 2135 [iso [2s | 10m | aas | 235 | 128 | 225 | 128 | 3.19 1950 | 1950 | 2135 | 150 | 25 | 107 | 215 | 2435 | 128 | 236 | 1.28 | 3.30 2100 | 2100 | 2135 | 150 | 225 | tom | 2s | mass [128 | 207 | 1.28 | 3.1 1os0 [1050 [2400 [150 [25 | om [215 | za0 | as | ae | 1a | 292 200 | 1200 | 2440 | 150 | 25 | 107 | 215 | zo | sas | 192 | 1a | 3.03 1350_| 1350 | 2400 [iso [25 | 10m [215 | zo | 14s | 203 | 144 | 3.14 1500 | 1500 | 2440 [150 | 25 | 107 | 215 | zo | 4s | 200 | 1a | 3.25 2aoox [1650 | 1650 | 2440 | 150 | 25 | som | 215 | 240 | 14 | 225 | as | 236 100 | 1200 | 2400 [150 [25 | om [215 | zra0 | nas [236 | aaa [3.07 asso_ [asso [za [aso [22s | wo [as | zo | aas | zar | 1a | 358 2100 [2100 | 2440 | 150 [25 [tom | 25 | 2740 [a4 [259 | aa [369 2400 [2400 | 2440 [aso [225 [tom | 25 | 240 | a | 281 [aa [391 az00_ | 4200 | 2745 | ie0 [225 | tm [a5 | sos | aes | 246 | ne [3.7 13s0_| 1350 [2745 [180 | 25 | 107 [215 | 310s | 6s | 259 | 164 | 3.90 3500 | 1500 | 2745 | seo | 25 | 107 | 215 | 30s | aes | 273 | 164 | 4.03 1650 | 1650 | 2705 | a0 | 25 | 10m | 215 | 3105 | 168 | 295 | 16 | 416 a7o0x | 1800 | 1800 | 2m | 180 | 25 | som | 215 | s40s | 161 | 299 | 64 | 430 1950, | 950 [/ 2745 [eo | 225, [tomo [215 | 3105 | aes [32 |e [403 2100 [2100 | 2745 | 180 | 225 | tom | 25 | 3105 | tes [326 | nen | 456 2400 [2400 | 2745 | 180 | 225 | tom | 215 | si0s | 16s | 352 | 6s | ass 270 | 2700 | 2745 | 180 | 25 | tom | 215 | ats | res | 379 | 264 | 5.09 In view of continual improvement OKA reserves the right to alter the Specifications! dimensions without prior notice. (MARCH, 2020, OKA SUPER SIZE BOX CULVERT DETAILS OF OKA SUPER SIZE BOX CULVERT DIMENSIONS (mm) 1070 1070 1070 Notes : OKA box culverts with opening at Lid or Invert can be manufactured upon request. Box culverts with others specified strength and dimensions can also be manufactured upon request. (Non standard products). = OKA CONCRETE INDUSTRIES SDN. BHD. SUDSIDIARY OF OKA CORPORATION BERHAD gs: Head Office : No.G, Lebuhraya Chateau, Off Persian Kemper, 30250 Ipoh, Perak Tel : 05-254 2741, 05 -2542745, 05 - 2542746, = 254 2748, 05 -254 2218, 05 - 253 1734, 05-242 5211, 05 - 242 5212 Fax : 05-253 2403, 05-241 1851 Uka@ vka.wun.1y Homepage : http.//wea.oka.Lum.! aca Johor BN, Of Jan Gopeng / atu Gah, 31300 Kampong Keparan. po, Peak Lat548, Mum Sana alan Seeing, 81400 Sen ihor. ‘Negeri Sembilan aang 12500, 82, nln Fajar-Batane Bena, 71800 Wi, Neger Sembilan 0¢2917, satu 3 ebutvaya Tun Abul azak, 26300 Gambang, Pahang. Kedah ‘aaa Lumpur Pot 3, Kawasan Perindustrian Buk Selembau, 010 Buk Slam, Sp.Petan Haéah _NWY-C230, Cova Square SOHO, lla TebnoogPIU5, Kota Damansara, Tel :016533 #333 Fax: 064197523, {780 Petaling Jaya, SeiangorOaul han.” “el O16S50 0088 / 03.7622 1731. Fax: 03-7622 1750

You might also like