You are on page 1of 21

Fit Symbol 50H8/d9 100H7/s6 60S6/h12

Basic Size (BS) mm 50 100 60


Fundamental Deviation (FD) 0.000 0.000 -0.042
Tolerance (T) (mm) 0.039 0.035 0.019
Lower Limit of Hole (mm) (LLH)
{BS+FD for upto H; BS+FD-T or ULH-T for after
For Hole H} 50.000 100.000 59.939
Upper Limit of Hole (mm) (ULH)
{BS+FD+T or LLH+T for upto H; BS+FD for
after H} 50.039 100.035 59.958
Lower Deviation 0.000 0.000 -0.061
Upper Deviation 0.039 0.035 -0.042
Basic Size (BS) 50 100 60
Fundamental Deviation (FD) -0.080 0.071 0.000
Tolerance (T) 0.062 0.022 0.300
Lower Limit of Shaft (LLS)
{BS+FD for after h; BS+FD-T or ULS -T for upto
For Shaft h} 49.858 100.071 59.700
Upper Limit of Shaft (ULS)
{BS+FD for upto h; BS+FD+T or LLS+T for after
h} 49.920 100.093 60.000
Lower Deviation -0.142 0.071 -0.300
Upper Deviation -0.080 0.093 0.000

Minimum Allowance
(Maximum Material Condition; LLH-ULS) 0.080 -0.093 -0.061
Maximum Allowance
(Minimum Material condition; ULH-LLS) 0.181 -0.036 0.258

Type of fit Clearance Interference Transitional


Hole/Shaft Basis system Hole Basis Hole Basis Shaft Basis
130H7/u6 150H7/n6 180S7/h6
130 150 180
0.000 0.000 -0.093
0.040 0.040 0.040

130.000 150.000 179.867

130.040 150.040 179.907


0.000 0.000 -0.133
0.040 0.040 -0.093
130 150 180
0.170 0.023 0.000
0.025 0.025 0.025

130.170 150.023 179.975

130.195 150.048 180.000


0.170 0.023 -0.025
0.195 0.048 0.000

-0.195 -0.048 -0.133

-0.130 0.017 -0.068

Interference Transitional Interference


Hole Basis Hole Basis Shaft Basis