Professional Documents
Culture Documents
2 OMICRON
Contents
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.1 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 Compliance statements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4 Information for disposal and recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5 Connecting ARC 256x to CMC test set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6 Mounting ARC 256x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
7 ARC 256x front panel indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
8 Configuring ARC 256x in Test Universe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
9 Configuring ARC 256x in CMControl P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
10 Field performance examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
10.1 High-speed output tripping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
11 Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
12 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
12.1 Mechanical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
12.2 Emission intensity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
12.3 Maximum pulse rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
12.4 Continuous duty limitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
12.5 Pulse response time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
12.6 Internal supply voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
12.7 Current drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
12.8 Start-up time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
OMICRON 3
ARC 256x User Manual
4 OMICRON
Preface
The purpose of this user manual is to familiarize you with ARC 256x and to show you how to use
ARC 256x safely, properly, and efficiently. Following the instructions in this user manual will help you
prevent danger, repair costs, and possible down time due to incorrect operation, and it will help you
maintain the reliability and life of ARC 256x.
This manual is to be supplemented by existing national safety standards for accident prevention and
environmental protection.
The user manual shall always be available at the site where ARC 256x is used. It shall be read and
observed by all personnel operating ARC 256x. Reading the user manual of ARC 256x alone does not
release you from the duty of complying with all safety regulations relevant and applicable to working on
systems in any power distribution network.
In addition to the user manual and the applicable safety regulations in the country and at the site of
operation, the usual technical procedures for safe and competent work shall be heeded. Keep this
manual during the entire service life of the product and always have it available for reference.
OMICRON 5
ARC 256x User Manual
6 OMICRON
Safety instructions
1 Safety instructions
Before operating ARC 256x, carefully read the following safety instructions. Only operate ARC 256x
after you have read this user manual and fully understood the instructions herein.
• Use ARC 256x exclusively in conjunction with the OMICRON test sets listed and the application field
specified under “Designated Use” below. The manufacturer is not liable for damage resulting from
unintended usage.
• Do not stare at the lens during operation as the high intensity light source may cause damage to
your eyes.
• Use ARC 256x only in a technically sound condition.
• Do not open ARC 256x or remove any of its components.
• Keep this manual available on site where ARC 256x is used.
2 Designated use
The ARC 256x Arc Flash Initiator is an accessory for OMICRON CMC test sets. To test an arc flash
protection system, ARC 256x simulates an arc by emitting a high-intensity light pulse from its Xenon gas
discharge tube. The protection system’s arc flash sensor (fiber or point-shaped) detects this light pulse
and signals the event to the arc flash protection relay.
The CMC test set provides both the supply voltage (max. 15 V) as well as the trigger signal for
ARC 256x. The actual test is carried out using either the State Sequencer test module of the
Test Universe software or CMControl P.
Any other use of ARC 256x is considered improper and may result in damage to property or persons.
OMICRON 7
ARC 256x User Manual
3 Compliance statements
ARC 256x is designated in the following statements as ‘product’, ‘equipment’, or ‘apparatus’.
Declaration of conformity (EU)
The equipment adheres to the guidelines of the council of the European Community for meeting the
requirements of the member states regarding the electromagnetic compatibility (EMC) directive, the low
voltage directive (LVD) and the RoHS directive.
FCC compliance (USA)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
Declaration of compliance (Canada)
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
8 OMICRON
Connecting ARC 256x to CMC test set
Connection cable,
6 m (19.7 ft) ARC 256x
WARNING
Check device before operating. Avoid serious injury or death caused by damaged
ARC 256x housing.
►Inside ARC 256x voltages up to 300 V appear. Always make sure that the device is not
damaged before operating ARC 256x.
ARC 256x is connected directly to a CMC test set ext. Interface connector by means of the attached
cable.
After connection of the ARC 256x device, the green LED will light solidly once the device is ready for
use. The Xenon flash simulated arc is produced each time the CMC test set commands it to do so (see
below).
ARC 256x should be positioned in a suitable location using the supplied plastic tack. Ensure that the tack
does not obscure the lens.
Align ARC 256x to make sure that the lens on the back of the device is centered over the length of the
arc flash detector fiber or lens. This will vary slightly depending whether the detector is a point or linear
sensor. Ensure that the lens is at least 2 cm away from the sensor or fiber. When positioning ARC 256x
over a fiber, align ARC 256x at an approximately 30 degree angle. This will ensure best coupling of the
light into the fiber. Ensure that ARC 256x is correctly aligned, and reposition if required.
OMICRON 9
ARC 256x User Manual
Power LED
LED is on when the
CMC test set
provides power to
ARC 256x.
The Power/Ready LED (green) will light when the CMC test set power is turned on. The LED indicates
that the ARC 256x internal power supply is operating correctly.
A flashing LED indicates that the internal circuitry is preparing for the next Xenon flash. Simply wait until
the LED is on solidly before beginning first use. A short duration or brief blink during use indicates that
the circuitry is refreshing the internal circuitry continuously. This will not affect the use. After a flash
event, the LED will again blink until the unit is ready for use.
10 OMICRON
Configuring ARC 256x in CMControl P
OMICRON 11
ARC 256x User Manual
The SEL751 relay used was equipped with high-speed outputs. By pointing ARC 256x directly at the arc
flash sensor, an overall trip time of 4.7 ms was achieved.
Zone 1 is the output of the SEL751 relay.
With ARC 256x not pointing directly towards the arc flash sensor, but still within a reflective chamber, an
overall trip time of 5.8 ms was achieved.
The usage of the electromechanical/conventional relay outputs of the SEL751 relay achieved an overall
trip time of 9.6 ms.
11 Ordering information
ARC 256x Article number VEHZ0092
12 Technical data
12.1 Mechanical data
Dimensions (w x h x d): 40 x 80 x 20 mm (1.57 x 3.15 x 0.79 inches)
Weight: 215 g (0.473 lbs)
Cable length: 6 m (19.7 ft)
6000 A/cm²
Black body
Wavelength
12 OMICRON
Technical data
OMICRON 13
ARC 256x User Manual
14 OMICRON
Support
Support
When you are working with our products we want to provide you with the greatest
possible benefits. If you need any support, we are here to assist you!
OMICRON electronics GmbH, Oberes Ried 1, 6833 Klaus, Austria, +43 59495
OMICRON 15
Support
16 OMICRON
ENU 1159 05 02