Professional Documents
Culture Documents
※ Check contact
Glow plug
24V 200A Normal : 0.942
relay
(For terminal 1-GND)
CR-24
6
5
4
3
2
1
B ※ Check contact
B-BR : 24V 1A
1
I ,O
OFF : ∞Ω(For each terminal)
Start key B-ACC : 24V 10A ON : 0Ω(For terminal 1-3 and 1-2)
B-ST : 24V 40A START : 0Ω(For terminal 1-5)
I I OH
6
5
3
2
CS AC B H
CS-2
1
Pressure switch Pa 10kgf/cm2 ※ Check contact
(Travel, working) 2 (N.C TYPE) Normal : 0.1Ω
CD-6 CD-7
2
Pressure switch Pa 3~6kgf/cm2 ※ Check contact
1
(For overload) (N.O TYPE) Normal : ∞Ω
CD-31
4-20
Part name Symbol Specifications Check
※ Check resistance
Glow plug 24V 200A
0.25 ~ 0.12Ω
CN-80
C 1 ※ Check resistance
Temperature
sensor - 50。C : 804Ω
(Hydraulic) 2 80。C : 310Ω
100。C : 180Ω
CD-8
CD-1
※ Check contact
Air cleaner Pa - High level : ∞Ω
pressure switch
Low level : 0Ω
CD-10
※ Check resistance
Full : 50Ω 6/12 : 350Ω
2 11/12 : 100Ω 5/12 : 400Ω
10/12 : 150Ω 4/12 : 450Ω
Fuel sender 1 -
9/12 : 200Ω 3/12 : 500Ω
8/12 : 250Ω 2/12 : 550Ω
CD-2 7/12 : 300Ω 1/12 : 600Ω
Empty warning : 700Ω
※ Check resistance
Normal : About 200Ω
Relay 24V 20A (For terminal 1-3)
CR-13 CR-33 CR-45 0Ω
CR-46 CR-62 (For terminal 2-4)
30
※ Check resistance
87a 87 85
86
4-21
Part name Symbol Specifications Check
1
※ Check resistance
Solenoid valve 24V 1A Normal : 15~25Ω
2
(For terminal 1-2)
CN
C
60
7
86N
8-
CN-66 CN-68 CN-70
CN-88
CN
C
83
18N
9- CN-133 CN-137
2
※ Check resistance
EPPR valve 700mA Normal : 15~25Ω
1 (For terminal 1-2)
CN-75
CN-47
CN-23(LH)
CN-23(LH)
CN-24(RH)
CN-24(RH)
10 9 8 7 6 5 4 3 2 1
※ Check contact
10 6 5
Normal
Switch ON : 0 Ω(For terminal 1-5, 2-6)
24V 8A
(Locking type) ∞ Ω(For terminal 5-7, 6-8)
9 8 2 7 1 OFF : ∞ Ω(For terminal 1-5, 2-6)
CS-23 CS-27 CS-50 0 Ω(For terminal 5-7, 6-8)
CS-52 CS-54
※ Check resist
Normal : About 5kΩ
A + (For terminal A-C)
Accel dial B S - Normal : Abowt 5V
C - (For terminal A-C)
CN-142 : 2~4.5V
(For terminal C-B)
4-22
Part name Symbol Specifications Check
8
2
7
9
1
I
※ Check disconnection
Normal : 1.0Ω
ON : 0Ω(For terminal 1-5, 2-6)
Switch 24V 8A
6
∞Ω(For terminal 5-7, 6-8)
10
OFF : ∞Ω(For terminal 1-5, 6-8)
10
2
6
1
4
5
8
9
0Ω(For terminal 5-7, 6-8)
CS-67
2
Head lamp, 24V 70W
Work lamp, (H3 Type) ※ Check disconnection
Room lamp, 1 24V 10W Normal : A few Ω
Cab lamp (Room lamp)
CL-1 CL-3 CL-4 CL-5
CL-6 CL-8 CL-9
CL-7
CL
-
1 M
24V 10A ※Check resistance
Fuel filler pump 2 35ℓ /min Normal : 1.0Ω
CN-61
1 ※Check operation
Hour meter h 16~32V Supply power(24V) to terminal
2 No.2 and connect terminal No.1
and ground
CN-48
※Check operation
DC22~28V
Horm Supply power(24V) to each
2A
terminal and connect ground.
CN-20
CN
C
20
,N
- CN-25
4-23
Part name Symbol Specifications Check
2 3 1 ※Check contact
Normal : 0Ω(For terminal 1-2)
24V 15A
Safety switch 1 2 ∞Ω(For terminal 1-3)
(N.C TYPE)
Operating : ∞Ω(For terminal 1-2)
3
1 0Ω(For terminal 1-3)
CS-4
CS
-
1
P ※Check contact
Receiver dryer 24V 2.5A
2 Normal : ∞Ω
CN
2-
CN-29
N.C 1
S.R- 2
S.R- 3
S.L- 4
S.L- 5
N.C
ILL+
6
7 ※Check voltage
Cassette radio S.R+
S.R+
8
9 24V 2A 20~25V
ACC 10
B+ 11 (For terminal 10-14, 11-14)
S.L+ 12
S.L+ 13
GND 14
CN-27
M 2
※Check contact
Washer pump 24V 3.8A Normal : 10.7Ω(For terminal 1-2)
1
CN-22
3 1
2
5 3
Wiper motor 4
4
24V 2A ※Check disconnection
5
Normal : 7Ω(For terminal 2-6)
6 M 2 6
CN-21
4-24
Part name Symbol Specifications Check
A 24V
DC/DC 24V 24V(A-B)
B GND 12V 3A
Converter 12V (B-C)
C 12V 12V
CN-138
B G
3
※Check contact
Alternator 24V 55A Normal : 0Ω(For terminal B+-I)
I
U Normal : 24~27.5V
GN
CN
7-
CN-74
B
M Delco Remy ※Check contact
Starter
28MT 24V Normal : 0.1Ω
M
CN-45
CN
4-
※Check contact
Travel alarm 24V 0.5A
Normal : 5.2Ω
CN-81
1
Aircon ※Check contact
24V 79W
compressor Normal : 13.4Ω
CN-28
4-25
Part name Symbol Specifications Check
CR-23
※Check resistance
Blower motor 24V 9.5A
Normal : 2.5Ω(For terminal 1-2)
1 Lo 1 ※Check resistance
2 MH 3 Normal : 1.12Ω(For terminal 4-2)
Aircon resistor -
3 ML 2 2.07Ω(For terminal 2-3)
4 Hi 4
3.17Ω(For terminal 3-1)
※Check resistance
1 1。
C OFF Normal : 0Ω(For terminal 1-2),
Duct sensor
2 4。
C ON the atmosphere temp :
Over 4。C
※Check resistance
Door switch 24V 2W
Normal : About 5MΩ
CS-1
CS-1 CS-20
CS-53
Switch
(Power max, 1
one touch 24V 6A ※Check resistance
2 Normal : ∞Ω
decal, horn,
breaker) CS-5 CS-19
CS-26 CS-29
4-26
Part name Symbol Specifications Check
3 24V
2 SIG
0bar : 1V(For terminal 1-2)
Transducer 500bar
500bar : 5V(For terminal 1-2)
1 GND
CD-42 CD-43
3 24V
0bar : 1V(For terminal 1-2)
Transducer 2 SIG 50bar
50bar : 5V(For terminal 1-2)
1 GND
CD-44
2 ※Check disconnection
Fusible Normal : 0Ω
60A
link (Connect ring terminal and check
1
resist between terminal 1 and 2)
CN-60 CN95