You are on page 1of 1

INNOVA 4.

Specification
Infrared temperature transmitter Metallurgy, petrochemical industry, power industry,light industry,
textile industry, food industry, national defense industry sector
and scientific research etc.

Model No: D T 8 3 0 0 B / D T 8 6 0 0 B / D T 8 0 1 2 B / D T8018B


Temperature Range: DT8300B/-50℃-300℃ (-58℉~572℉ )
DT8600B/ -50℃ -600 ℃(-58℉~1112℉)
DT8012B/ -50℃-1200℃(-58℉~2192℉)
DT8018B/ -50℃-1800℃ (-58℉~3272℉)
1.Description: Spectral Response:8-14um
Distance Spot Ratio: 50:1 ( -50℃-300℃ is 16: 1 )
As a Integrated transmitter infrared thermometer, DT8000B
has the integration of the sensor, the optical system and the Response Time: 500ms
electronic circuit inside its stainless steel or aluminium alloy
shell. It can be installed very conveniently by making the Accuracy: ±2% or 2℃
standard screw thread on the product be joined with the
installation position. Repeatability: ±1% or ±1℃
Emissivity: 0.95
2.The principle of temperature measurement
Power: 24V DC
by infrared:
The maximum current: 50mA
Any object transmits the infrared radiation, and the
radiation intensity varies with temperature.Infrared
Analog output:RT-A:4~20mA
temperature measurement uses thermal radiation within Isolation: Power, digital output and analog output are
the range of wavelength 8- 14um.
The infrared thermometer is a kind of hot- electron sensor isolated and do not interfere with each other.
which can receive the infrared radiation andtransform it to
a measurable electric signal, and itsmain assemblies are as Protection level: IP65 (NEMA-4)
following:
Environmental temperature: 0-50℃
---Lens Storage temperature: -20-50℃
---Spectrum filter
---Detector Relative Humidity: 10-95%
---Electronic circuit Shell material: Aluminium alloy or stainless steel (Optional)
(Amplifier/ linearization/ signal processing)
Standard wire length:
Light path of the infrared thermometer is determinedby the
specification of lens. The spectrum filter can choose the best 2M (or can be 5M or 10M or other length you need)
spectral range for temperature measurement.The power of
With CE approval and protection against electromagnetic
infrared radiation can betransformed to electric signal by
detector and electronic circuit. disturbance for EU standard.

3. Main features: 10
AC 85V - 264V
1

5.Instructions: 11

12
2

4 DC24V+
---High precision signal wire + red 、laser wire +blue
13

14
5
DC24V -
---High optical resolution ratio 15
6
+
4 - 20mA
7
16

---Firm metal shell signal wire –black、laser wire – yellow 17 8

18 9 -
---Large temperature range: -50℃~1800℃
1.Alternating voltage 85-264V contact to theconnection
---Output:4- 20MA
10-11.
---Target size: no less than 16mm 2.Signal wire red wire contact to the connection 4
(DC24V+).
D:S=16:1
3.Signal wire black wire contact to the connection 6.
OUTPOUT≤1mW WAVELENGTH 630~670nm
Red signal wire + pole 4.Connection 5(DC24V-) contact to connection 9.
50mm
22.5mm
black signal wire – pole Connected with the short circuit,please see the picture.
5.Use 9V battery power to contact laser toopen laser
360mm
and use laser to target before fix and install.
700mm !
1
LASER RADIATION DO NOT STARE IN TO BEAM AC 85V-264 12 DC24-
CAUTION CLASS II LASER PRODUCT 1.Alternating voltage 85-264V contact 2
to the connection1-2. 13
3
2.Signal wire red wire contact to the 14 DC24V+
D:S=50:1 connection 14 (DC24V+). 4
OUTPOUT≤1mW WAVELENGTH 630~670nm 3.Signal wire black wire contact to the 15
36mm connection 6. 5
16mm 16
4.Connection 8 contact to connection 6
+
12 to make short circuit, please see 17
800mm the picture. 7
4-20mA
5.Use 9V battery power to contact laser 18
1.5m ! to open laser and use laser to target - 8
before fix and install. 19
LASER RADIATION DO NOT STARE IN TO BEAM
CAUTION CLASS II LASER PRODUCT
9
20