You are on page 1of 4
edcon UPS TB Series Online Transformer-based UPS 10 - 300 KVA (3/3 Phase) edcon UPS TB Series 10-300 KVA ‘The EDCON TB Series is double conversion on-line technology (VFI) with an in-built isolation transformer on the inverter output. The load is powered continuously by the inverter with filtered, stabilized and regulated sine wave supply. The input and output EM filters considerably increase the protection of the load to mains power disturbances and surges, TB Series provides maximum protection for vital network equipments, security applications, electromedical equipments (CT Scanner, XRay, MRI, etc.), and industrial applications with the advanced mechanical and electrical design. ™ Advanced design 3 a a ag tenses tear ‘Common battery bank sharing in parallel system Flexible battery configuration improves service ability High power density design with compact size ‘Smart generator compatible Easy on-site parallel modification Intelligent Management ™ Main Features ‘Online double conversion IGBT inverter Galvanic Output isolation transformer Wide input voltage range 3 phase UPS allow 100% unbalance load Fully DSP control, high reliability and perfomance Intelligent fan speed control HMl-touch screen display 10.000 event logs Intelligent RS232/RS485/DB9 Dry Contact ‘communication port ‘vette | ovpttecar Frequency converter function (60Hz to S0Hz or 50Hz to 60H2) Self-aging test function without load enables on-site commission Multiple communication interfaces support UPS and load monitoring Intelligent SNMP achieves local monitoring and remote monitoring Battery temperature compensation function extends battery service life Battery self-test function and battery temperature compen- sation function improve the battery performance and extend battery use life Intelligent fan control, according to load capacity reduces the noise and prolongs fan service life Battery setftest function Inteligent RS232/RS485/DB8 communication port MODBUS & SNMP adapter (optional) 12 pulse rectifier (optional) Bypass isolation transfomer (optional) Lightning protection ECO mode and EPO function ECO-mode with 98% efficiency Parallel redundant recommended to 4 units, maximum 8 units (optional) ee cccccce edcon UPS TB Series 10-300 KVA © Reliable Design ‘© The output isolation transformer provides high reliability to adapt different harsh industrial environments and protects the critical loads © Unbalance load design can adapt to different kinds of complex applications © Dual air duct design offers better cooling to protect the key components and extend the service life © Dual power supply redundancy © Wide input voltage range provides high adaptability to the grid and extend the battery service life © Main PCB Board with professional electromagnetic shielding improves reliable performance of EMC © Anti-corrosion PCB i, Innovative Upgrade © Dual DSP (Digital Signaling Processor) technology makes the data processing faster, more precise, and more reliable © High output PF = 0.9 meet high requirements of applications '* ECO-Mode (98% efficiency) gives the possibility of significant cost reduction and heat emission © Bus synchronization control function provides reliable high power for dual bus application © Advanced no-master-slave parallel technology achieves online power expansion and prevent single fault ™® More Options © Flexible network management SNMP © Intelligent battery monitoring system © Bypass voitage regulator © Dual system control card © Auto switch STS and ATS © N#X in parallel © Input Isolation transformer © Output synchronization common bus © Battery charge temperature compensation © Advanced no-master slave parallel technology © DC cold start function TB Series 10-300 KVA Voltage (Vac) 380/400/415325% Rectifier Frequency (Hal 40-10 Tee ey 50/60::10% (45% settable) Phase 3 oaWiPE Power Factor 09 Crest Factor 3a Copacty(kvA)] 10] 20, 30, 40 | 60, 80 | 100 120) 160 200 | 250 | 300 Power Factor 09 Phase 3 4WiPE Voltage (Vac) (EN: 220/230/24081%, (-: 360/200/415% Frequency (a) 30/6040.2 (battery mode) Waveform Pure sine wave, THO 2% (linear load) 3 Phase 100% Load Unbalance Voltage 2%, allow 100% unbalance stability Efficiency AC to AC 092 overload 125%, load for 10 mins, 150% load for 1 min BATTERY Voltage (Vd) 348 (360 settable) 384 (348/360/372 settable) Battery Type External, maintenancecree sealed lead-acid Charging Current (A) 10-40A settable 10-1004 setable ons ‘Maintenane Bypass Yes Gommurietion ideo BS 485/ MODBUS/ Dry Contacts RS232/RS485/Dry Contacts (SNIMP is Optional) (SNMP is Optional) ENS0091-1-1/1£652040-1-1/4S 62040-1-1 for General safety requirement in pplsbe Standards ‘operator access area, ENS0091-2/1EC62040-2/AS 62040-2 (C3) for Electromagnetic compatibilitylEMC) requirements fr UPS. ENSOO91-3/1EC52040:3/8S 62040-3 (VFI SS 111) for Method of specifying the performance & test requirement of UPS Display Touch sereen LOD + LED, EPO, Alarm ‘Alarm Overload, abnormal AC input, low battery, UPS failure, ete, Protection Low battery, overload, over temperature, short circu, output over voltage, output low voltage, ete. ‘Mechanical protection 1P20 Noise (48) <65 <70 Working Temperature oat Relative Humidity 10.95%, No condensation Dimension i pistes 500%600x1180 500480011600 ooxsooxssc0 | oox1000x1850 | 1000" ‘Weight (kg) 230 | 260 | 300 | 400 | 450 | 520 | 600 | 650 | 825 1280 | 1568 [1830 + Specification is subject to change without prior notice ‘if higher charging current is adjusted, the UPS capacity shall be derated. _ c€

You might also like